Home

Monster Power 109457-00 surge protector

image

Contents

1. Digital Outlets i HOOK UP GUIDE Video Outlet Hook Up These outlets have a special filter circuit that is optimized to reduce interference to your video components A Attach a Monster Power identification label to each component s power cord before you plug it into the appropriate color coded PowerCenter outlet B Plug each component s power cord TV Monitor VCR into the PowerCenter s corresponding outlet For components not listed determine if they are audio video digital or ultra high current audio components and use a corresponding outlet for best performance IMPORTANT NOTE It does not harm analog audio digital or high current audio components to be connected to the video outlets However for best performance we recommend plugging in only video components to the video outlets NETWORK SURGE PROTECTION PHONE LINE SURGE PROTECTION Cet a CL Video Outlets HOOK UP GUIDE Analog Audio Outlet Hook Up These outlets have a special filter circuit that is optimized to reduce interference to your audio components A Attach a Monster Power identification label to each component s power cord before you plug it into the appropriate color coded PowerCenter outlet B Plug each component s pow
2. die p Hoe io 8 LU ES Brill e e d uu MONSTER SIGNATURE PRO5100 POWERCENTER FEATURES SIGNATURE PRO 5100 REAR VIEW I 4 1 t 1 I 20 ri lt mm ja merae qual cu lemma Monster Power PRO 5100 ID Labels DVD TW PROJECTOR TV PROJECTOR Covo DVD TW PROJECTOR TV PROJECTOR CABLE SAT CABLE SAT VCR VCR CABLE SAT CABLE SAT VCR VCR RECEIVER RECEIVER MAIN AMP MAIN RECEIVER RECEIVER MAIN MAIN AMP PROCESSOR PROCESSOR SPARE SPARE PROCESSOR PROCESSOR SPARE SPARE CD DVR DVR DVR M PWN 10 11 12 13 14 15 16 17 SIGNATURE 5100 POWERCENTER FEATURES Clean Power On Indicator Indicates Monster Clean Power circuitry is functioning properly Unswitched On Indicator Indicates power is being supplied to the unswitched outlets Switched On Indicator Indicates power is being supplied to the switched outlets Timed On Indicator Indicates power is being supplied to outlets with the sequential
3. Branchez l appareil dans une prise de 120 V nominal correctement mise la terre L image vid o est mauvaise et comporte du bruit ou des images fant mes Le signal vid o entrant n est pas correctement mis la terre e Contactez votre fournisseur de c ble ou de satellite pour v rifier votre installation Le PowerCenter met un son strident Le circuit de protection du PowerCenter a br l pour prot ger votre quipement d une importante surtension Le PowerCenter doit tre remplac Consultez la section Informations sur la garantie de ce manuel pour les d tails importants SP CIFICATIONS SIGNATURE PRO 5100 POWERCENTER T che continue Classification lectrique IE Courant maximum 20A 2400W Phase Neutre P N Modes de protection Phase Terre P T Neutre Terre N T Dissipation d nergie totale 6814 Joules Niveau de blocage tension de suppression des 330 Volts surtensions transitoires Temps de r ponse de blocage Moins de 1 nanoseconde lt 1ns Contr le de l alimentation d entr e c c DC In distance Contr le de l alimentation de sortie c c DC Out distance Dimensions 3 30V 12V c c 100mA Largeur 434 98mm Hauteur avec les pieds 133 35mm Hauteur sans les pieds 146 05mm Profondeur avec les poign es 368 3mm Profondeur sans les poign es 419 1mm LIMITED WARRANTY FOR CONSUMERS
4. PHONE LINE SURGE PROTECTION di d rom Telephone Wall Jack IN DUT 2 OUT 3 To Satellite Receiver Digital Video Recorder DVR or Telephone NOTE The Signature PRO 5100 is not intended for hook up of any phone which carries two separate phone lines on a single 4 RJ11 jack ap HOOK UP GUIDE Ethernet Connections Hook Up Ethernet connections provide surge protection against damaging voltage surges and spikes coming from Ethernet line Protect Ethernet Connections as Follows ETHERNET LINE SURGE PROTECTION From incoming To the Ethernet connection Ethernet Line on your component HOOK UP GUIDE Remote DC In Control Hook Up This feature connects your PowerCenter to an automated Home Theater control system or allows another component with a Remote DC Out connection to automatically turn on and off your PowerCenter A Plug the AC power cable of the component you are using to control the PowerCenter into an unswitched outlet on the PowerCenter Note This component must deliver a control voltage between 3 30 volts DC B Plug one end of the 1 8 miniplug supplied into the corresponding Remote DC In connection on the PowerCenter C Plug the other end of the 1 8 miniplug into the Remote DC Out connection on the component th
5. CAUTION Exposure To Heat Do not expose your Monster PowerCenter to direct sunlight or place it near wall heaters space heaters or any enclosed Space prone to temperature increase CAUTION Proper Cleaning In general the only cleaning necessary for your Monster PowerCenter is a light dusting Unplug your component from the wall before cleaning it Do not use any type of liquid or aerosol cleaners PROPER GROUNDING AND INSTALLATION WARNING Proper Grounding Monster PowerCenters require a properly grounded outlet for safety and to protect connected equipment If you re not sure if your home s electrical wiring is properly grounded have it checked by a qualified electrician Important Note Proper Power and Protection To completely protect your equipment against electrical surges every AC power cable coaxial cable phone line and Ethernet line in the system must be connected to an appropriate PowerCenter Important Note Proper Protection and the Limited Connected Equipment Warranty The Limited Connected Equipment Warranty becomes invalid if any wire AC coax phone or Ethernet or audio or video interconnect leading into the equipment comes from a component that is not properly protected by the PowerCenter The Limited Connected Equipment Warranty becomes invalid when the PowerCenter is operated in a non fixed install environment See the Warranty Information section of this owner s manual for important details A
6. Connect your PowerCenter to a dedicated outlet Try unplugging different components from the PowerCenter one at a time to see if the noise stops If a component is discovered to be improperly grounded attach a copper wire f rom the component s chassis to the PowerCenter s grounding post Symptom TROUBLESHOOTING Possible Cause Remedy The Unswitched LED on front panel is Off The PowerCenter is not plugged in The PowerCenter is plugged in but the outlet is not receiving power Plug the PowerCenter into a properly grounded 120 volts nominal outlet and make sure it is on The Switched LED is Off You are using the Switched Outlet Remote Turn On feature and haven t plugged the plug into the component you wish to use to activate the Remote Turn On The component remote control you are using to power the Remote turn on has a dead battery Plug the plug into the component you wish to use to activate the Remote Turn On Replace the battery powering the component remote control Plug the component into a properly grounded 120 volt nominal outlet The component you wish to use to activate the Remote Turn On isn t plugged into a properly grounded 120 volt nominal outlet Plug the PowerCenter into a properly grounded 120 volts nominal outlet Symptom Timed On indicator on front panel is Off TROUBLESHOOTING Possible Cause Yo
7. High Current Filter Indicator Indicates power is being supplied to the ultra high current outlets Unswitched Convenience Outlets These outlets are located on the front of the PowerCenter for easy access These outlets have a specially designed filter circuit for high current audio components LED Lamp Provides light to illuminate the front panel of the PowerCenter For convenience this lamp retracts into the PowerCenter Dimmer Knob Adjusts the brightness of the LED lamps Ethernet Line Surge Suppression Provides surge protection against damaging voltage surges and spikes from the Ethernet line Phone Line Surge Suppression Provides surge protection against damaging voltage surges and spikes from the phone line Digital Input Voltage and Current Usage Meter Indicates input voltage and amperage draw Outlet On Indicator Indicates power is being supplied to the designated outlet bank Digital Filter 1 These outlets have a specifically designed filter circuit that reduces interference to your digital components Digital Filter 2 These outlets have a specifically designed filter circuit that reduces interference to your digital components Video Filter These outlets have a specifically designed filter circuit that reduces interference to your video components Analog Audio Filter These outlets have a specifically designed filter circuit that reduces interference to your audio components Ultra High Current Audio Filter These
8. GUIDE DE RACCORDEMENT C R gler la paire de prises en mode de commutation avec retard d allumage SWITCHED ON AFTER DELAY Appuyez sur MENU jusqu ce que l afficheur indique le statut de la paire de prises analogiques ANALOG Appuyez sur le bouton de s lection SELECT jusqu ce que l afficheur indique le d lai en secondes que vous ANA 2 20 we d sirez appliquer sur la paire de prises apr s avoir appuy sur le bouton ON OFF Une fois que le PowerSource est allum en appuyant sur le bouton ON OFF du panneau avant ou une fois que l allumage du PowerSource est d clench automatiquement par un signal ext rieur la paire de prises sera aliment e apr s le d lai choisi ci dessus 20 secondes dans ce cas Les prises r gl es avec le d lai d allumage maximal ANA s teindront cependant d s l instant o le bouton ON OFF est activ ou lorsque l extinction du PowerSource est d clench e par un signal ext rieur D R gler la paire de prises en mode non commut UNSWITCHED prises toujours aliment es Appuyez sur le bouton MENU jusqu ce que l afficheur indique le statut de la paire de prises analogiques ANALOG Appuyez sur le bouton de s lection SELECT jusqu ce que vous obteniez l affichage Uen fois que le mode non commut UNSWITCHED est s lectionn tout appareil branch dans ces prises sera aliment en continu tant que le PowerCenter est branch dans une prise murale de 120V qui est elle m me alim
9. Permet d allumer automatiquement le PowerCenter par la commande d alimentation de sortie c c DC Out distance d un autre appareil tel qu un r cepteur audio vid o Contr le de l alimentation d entr e c a AC In distance Permet au PowerCenter se s allumer automatiquement gr ce un d clencheur c a distance branch dans une prise d un autre appareil tel qu un r cepteur audio vid o Contr le de l alimentation de sortie c c DC Out distance Vous permet de mettre un appareil contr l distance automatiquement en marche lorsque le PowerCenter est allum Bouton de mise en marche arr t teint ou allume les prises programm es par commutation SWITCHED ON ou par commutation avec retard d allumage SWITCHED ON AFTER DELAY Bouton Menu Appuyez pour d marrer le mode de programmation Bouton Menu Appuyez pour valider les param tres ou les options s lectionn es par le bouton Menu Bouton Menu Ajuste la luminosit de l affichage alphanum rique C ble d alimentation c a haute capacit PowerLine 400 Cordon d alimentation haute densit et double blindage sp cialement concu pour optimiser l alimentation en courant Vis de mise la terre Fournit une masse de r f rence pour tout appareil sans mise la terre Disjoncteur de 20 Prot ge le PowerCenter d une surcharge continue tiquettes Monster Power identifi es par un code de couleurs pour l audio vid o Pour une identifi
10. CCABLE SAT CABLE SAT VCR VCR CABLE SAT CABLE SAT VCR VCR RECEIVER RECEIVER MAIN AMP MAIN RECEIVER RECEIVER MAIN MAIN PROCESSOR PROCESSOR SPARE SPARE PROCESSOR PROCESSOR SPARE SPARE DVR DVR CARACT RISTIQUES DU SIGNATURE PRO 5100 POWERCENTER T moin de fonctionnement de la technologie Clean Power Indique si le circuit Clean Power de Monster fonctionne correctement T moin de fonctionnement des prises non commut es Indique si les prises d alimentation non commut es de l appareil sont mises Sous tension T moin de fonctionnement des prises commut es Indique si les prises d alimentation commut es de l appareil sont mises sous tension 4 T moin de fonctionnement de l alimentation s quentielle Indique si les prises de sortie utilisant la fonction d alimentation s quentielle sont mises sous tension T moin de fonctionnement du mode de protection Indique si le circuit de protection des surtensions de Monster fonctionne correctement T moin de v rification de la mise la terre Indique si le PowerCenter est branch dans une prise d alimentation de 120 V c a avec une mise la terre ad quate T moin de v rification du c blage Indique si les c bles de phase et du neutre sont bien c bl s dans la prise murale Si l indicateur n est pas allum consultez votre compagnie
11. Monster LLC 7251 West Lake Mead Blvd Las Vegas NV USA Monster extends You this Limited Warranty Statutory or common law may provide You with additional rights or remedies which shall not be affected by this Limited Warranty DEFINITIONS Adequate Use means use of the Product and Connected Equipment i within a home or dwelling ii for private as opposed to commercial purposes iii in conformance with all applicable local state or federal law code or regulations including without limitation building and or electrical codes iv in accordance with manufacturer recommendations and or instructions in the materials and documentation that accompany the Product and any Connected Equipment v with proper electrical grounding vi with proper and direct connection between the Product and an AC power source that has protective grounding excluding gas or diesel powered generators vii with cable or telephone lines to any Connected Equipment properly connected to the Product and viii without a connection in a daisy chain fashion to or with any extension cord surge suppressor power strip uninterruptible power supply UPS or other equipment Authorized Dealer means any distributor reseller or retailer that i was duly authorized to do business in the jurisdiction where it sold the Product to You ii was permitted to sell You the Product under the laws of the jurisdiction where You bought the Product and iii sold
12. e de vie du PowerCenter tout en prot geant votre installation TAGES BREVET S CLEAN POWER DE MONSTER La technologie Clean Power de Monster effectue deux t ches vitales au maintien de la qualit optimis e pour le cin ma maison 1 le filtrage du bruit et 2 l isolation du bruit Plus le nombre d tages Clean Power est lev 1 5 et plus les filtres d limination du bruit g n r sur l alimentation c a sont complexes et avanc s En parall le plus le nombre d tages Clean Power est lev et plus l isolation entre les quipements est lev e optimisant ainsi l limination du bruit g n r par les composants Les appareils de la cat gorie PowerCenter de Monster qui offrent la technologie Clean Power sont tous concus avec un nombre d tages Clean Power sp cifique Le Signature PRO 5100 int gre un circuit Clean Power quatre tages qui filtre la fois le bruit sur l alimentation c a ainsi que le bruit g n r par votre propre quipement de niveau 4 de Clean Power implique cinq filtres isol s tr s avanc s constitu s par des filtres analogiques audio vid o et num riques ainsi qu un filtre audio de puissance qui permettent la meilleure limination du bruit sur l alimentation c a et la meilleure isolation entre appareils Toutes ces caract ristiques font du Signature PRO 5100 l appareil id al pour votre syst me de cin ma maison Pour en apprendre plus sur la technologie brevet e Clean Powe
13. equipment Authorized Dealer means any distributor reseller or retailer that i was duly authorized to do business in the jurisdiction where it sold the Product to You ii was permitted to sell You the Product under the laws of the jurisdiction where You bought the Product and iii sold You the Product new and in its original packaging Connected Equipment means any device that is i generally suited to be used with the Product or products of the same kind ii meets the requirements of all applicable laws and safety standards iii contains only parts manufactured sold or recommended by the original manufacturer of the Connected Equipment and iv has not been altered tampered with or modified by any person other than its manufacturer or service personnel authorized or recommended by the manufacturer of the Connected Equipment Connected Equipment Damage means physical damage caused to Connected Equipment due to a Product Defect i by a transient AC power cable telephone or lightning surge while connected to a properly installed Product ii not by a defect or unrelated damaging of the Connected Equipment or a surge spike or lightning strike through a source medium or connection other than through the Product and iii does not extend to loss of data or consequential indirect or special damages resulting from the Connected Equipment Damage Fair Market Value FMV means the fair market value of the Connected Equipment at
14. for repairs may be negotiated by Monster TIMING If You bring a Formal Warranty Claim and fully comply with all terms and conditions of this Limited Warranty Monster will use its best efforts to provide You with a remedy within thirty 30 days after receipt of Your Formal Warranty Claim if You reside in the United States forty five 45 days if You reside elsewhere unless obstacles outside Monster s control delay the process Ver 121703 US EU 2004 Monster LLC REMARQUES Nous vous invitons visiter les monstres l adresse MonsterPower com Concu aux tats Unis et fabriqu pour Monster selon ses sp cifications de qualit Fabriqu en Chine Am rique du Nord 2005 Monster LLC 7251 West Lake Mead Blvd Las Vegas NV 89128 tats Unis 1 877 800 8989 UnionEurop enne Monster Technology International Ltd Ballymaley Business Park Gort Road Ennis Co Clare Irlande 001 866 348 4171 Le Monster Power professionnel de r f rence PowerCenter Signature PRO5100 est prot g par le brevet am ricain no 5 589 718 D autres brevets sont en cours Monster Monster Cable Monster Power Clean Power PowerCenter PowerLine T2 et Tri Mode PowerLine T2 et Tri Mode sont des marques d pos es et non d pos es de Monster Cable Products inc et des subsidiaires de la marque aux tats Unis et ailleurs
15. in the Specifications Table below The Warranty Period commences on the date when You purchased or received whichever occurs later the Product from an Authorized Dealer as evidenced by the Authorized Dealer s invoice sales receipt or packing slip If You do not have written proof of the date of purchase or receipt then the Warranty Period commences three 3 months after the date when the Product left Monster s or its factory as evidenced by Monster s records The Warranty Period ends after the time defined in the Specifications Table has expired or after You have transferred ownership of the Product whichever occurs earlier Also You must call Monster and obtain a Return Authorization Number as described under How to Make a Claim within two 2 months after You discover a Product Defect or should have discovered it if such Product Defect was obvious You means the first individual person that purchased the Product in its original packaging from an Authorized Dealer This Limited Warranty does not apply to persons or entities that bought the Product i in used or unpackaged form ii for resale lease or other commercial use or iii from someone other than an Authorized Dealer SCOPE OF THIS LIMITED WARRANTY PRODUCTS Product contained a Product Defect when You bought it from an Authorized Dealer and Monster receives a Formal Warranty Claim from You within two 2 months after You discover such Product Defect or should have d
16. locale d lectricit ou un lectricien qualifi Indicateur d une condition de tension anormale Indique que la tension d entr e se situe hors de la gamme tol r e situ e entre 90 V c a et 125 V c a environ 9 Affichage num rique de la tension d entr e et de l amp rage utilis Indique la tension d entr e et le d bit en amp res 11 12 13 14 15 16 17 Bouton de d clenchement ou d extinction de l alimentation teint ou allume les prises programm es par commutation SWITCHED ON ou par commutation avec retard d allumage SWITCHED ON AFTER DELAY Bouton Menu Appuyez pour d marrer le mode de programmation Bouton de s lection Select Appuyez pour valider les param tres ou les options s lectionn es par le bouton Menu Bouton gradateur Dimmer Ajuste la luminosit de l affichage alphanum rique Ampoule DEL Illumine le panneau avant du PowerCenter Pour l aspect pratique cette lampe se r tracte dans le PowerCenter Gradateur Dimmer Ajuste la luminosit des lampes DEL Indicateur du filtre vid o Indique si les prises d alimentation vid o de l appareil sont mises sous tension Indicateur du filtre num rique 1 Indique si les prises d alimentation num riques de l appareil sont mises sous tension 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Indicateur du filtre num rique 2 Indique si les prises d alimentatio
17. outlets have specifically designed filter circuits that reduce interference to your high current audio components such as amplifiers and pre amplifiers TV Cable Protection Provides surge protection for a TV cable connection The input connects the coaxial cable from your antenna The output connects the coaxial cable to your TV or cable box input Satellite Protection Provides surge protection for a satellite connection The input connects the coaxial cable from your satellite dish The output connects the coaxial cable to your satellite receiver input Antenna Protection Provides surge protection for a antenna connection The input connects the coaxial cable from your radio antenna The output connects the coaxial cable to your antenna input Remote DC In Control Allows the PowerCenter to be turned on automatically via the Remote DC Out on another component such as an A V receiver Remote AC In Control Allows the PowerCenter to be automatically turned on by a remote AC trigger plugged into an outlet on another component such as an A V receiver Remote DC Out Control Allows you to turn a remote device on automatically when the PowerCenter is turned on On Off Button Turns ON OFF the outlets programmed as SWITCHED or SWITCHED ON AFTER DELAY Menu Button Press to begin programming mode Select Button Press to set parameters or options selected by the Menu button Dimmer Button Adjusts the br
18. the time Connected Equipment Damage occurs Formal Warranty Claim means a claim made in accordance with the section Formal Warranty Claims herein Maximum Coverage Amount means the maximum amount that Monster will pay to You under this Limited Warranty for Connected Equipment Damages and is defined in relation to each Product in the Specifications Table below Product means a Product i that is listed in the Specifications Table below ii that You bought from an Authorized Dealer new and in its original packaging and iii whose serial number if any has not been removed altered or defaced Product Defect means an inadequacy of the Product that existed at the time when You received the Product from an Authorized Dealer and that causes a failure of the Product to perform in accordance with Monster s documentation accompanying the Product unless such failure has been caused completely or partly by a any use other than Adequate Use b transportation neglect misuse or abuse by anyone other than Monster s employees c alteration tampering or modification of the product by anyone other than a Monster employee d accident other than a malfunction that would otherwise qualify as a Product Defect e maintenance or service of the Product by anyone other than a Monster employee f exposure of the Product to heat bright light sun liquids sand or other contaminants or 9 acts outside the control of Monster including withou
19. turn on feature Protection On Indicator Indicates Monster surge protection circuitry is functioning properly Ground OK Indicator Indicates the PowerCenter is plugged into a properly grounded 120V AC outlet Wiring OK Indicator Indicates the line and neutral wires at the wall outlet are wired properly If the indicator is not lit consult your local power company or a qualified electrician Abnormal Voltage Indicator Indicates that the incoming voltage is below approximately 80V AC or above approximately 125V AC Digital Input Voltage and Current Usage Meter Indicates input voltage and amperage draw On Off Button Turns ON OFF the outlets programmed as SWITCHED or SWITCHED ON AFTER DELAY Menu Button Press to begin programming mode Select Button Press to set parameters or options selected by the Menu button Dimmer Button Adjusts the brightness of the alphanumeric display LED Lamp Provides light to illuminate the front panel of the PowerCenter For convenience this lamp retracts into the PowerCenter Dimmer Knob Adjusts the brightness of the LED lamps Video Filter Indicator Indicates power is being supplied to the video outlets Digital Filter 1 Indicator Indicates power is being supplied to the digital outlets Digital Filter 2 Indicator Indicates power is being supplied to the digital outlets Audio Filter Indicator Indicates power is being supplied to the analog audio outlets
20. AFTER DELAY et non commut UNSWITCHED prise toujours aliment e ind pendamment pour chaque paire de prise Vous pouvez changer les r glages votre convenance En utilisant une paire de prise tiquet e ANALOG FILTER par exemple les sch mas suivants illustrent comment cela est fait A Allumer le PowerCenter Appuyez sur l interrupteur ON OFF une fois pour d marrer l appareil et commencer le processus Une fois que le PowerCenter est allum l afficheur indique la tension c a Figure 1 Remarque Le processus d allumage peut prendre jusqu 60 secondes puisque n importe quelle paire de prise peut tre configur e dans le mode de commutation avec retard d allumage SWITCHED ON AFTER DELAY Vous pouvez voir le statut de toute paire de prises en vous r f rant l indicateur correspondant sur le panneau avant B R gler la paire de prises en mode commut SWITCHED ON Appuyez sur MENU jusqu ce que la seconde ligne de l afficheur indique le statut de la paire de prises analogiques ANALOG Appuyez sur le bouton de s lection SELECT jusqu ce que le d lai passe 0 z ro ANR Le d lai de 0 z ro signifie que la paire de prises analogiques ANALOG fonctionne en mode commut SWITCHED ON Cette paire sera activ e une fois que le PowerCenter est allum en appuyant sur le bouton ON OFF du panneau avant ou une fois que l allumage du PowerCenter est d clench automatiquement par un signal ext rieur lt p gt
21. MONSTER POWER Professional PowerCenter Signature PRO 5100 Owner s Manual The M ook gita deo gt lt 0 Outlet mportant Safety Information Proper Grounding and Installation Note from The Head Monster onster Exclusive T2 Technology onster Patented Clean Power Stages nds Behind The Monster PowerCenter Design onster Signature PRO 5100 PowerCenter Features WO GUIS Quilets QU CES oie poemes bos eds nalog Audio Outlets tra High Current Audio Outlets Programming Audib Automatic Shutdown Setting Coaxial Connections Phone Ethern Specifi Appendi Connections et Connections Remote DC In Control Remote AC In Remote DC Out Rack Mouritifig e Rack Handles Troubleshooting EOE EEEE TEETE EEEE X Warranty Information TABLE OF CONTENTS Page OO BW amp IMP
22. NOTE FROM THE HEAD MONSTER THANK YOU for purchasing the Monster Power Professional Reference PowerCenter Signature PRO5100 designed to offer you the best performance and most comprehensive home theater and AN system protection available The Signature PRO 5100 is designed for the professional A V installer working on high end home systems recording and touring environments and many other listening amp viewing environments where top performance is a must The Signature PRO 5100 s many enhanced features were incorporated into the design with these users and environments in mind The Signature PRO 5100 features patented Monster Clean Power stage 4 v 2 0 filter circuitry that virtually stops the electromagnetic and radio frequency which can degrade sound and picture quality In addition your PowerCenter also features patented noise isolation circuits that separate analog audio video digital and ultra high current audio outlets The result is high quality sound and picture that s free from performance damaging interference Noel Lee Other Monster Power breakthroughs include exclusive T2 automatic disconnect reconnect protection circuitry and patented Tri Mode protection featuring an audible alarm These features automatically disconnect power from your electronics if you re hit by a big surge We ve included surge protected coax phone and Ethernet connections to ensure protection for all of your components The Signature PRO5100 also
23. ORTANT SAFETY INFORMATION Please read and observe the following safety points at all times A WARNING Power Sources Do not plug this Monster PowerCenter into a power outlet that differs from the source indicated for safe use on the PowerCenter If you don t know the type of electrical power that is supplied to your home consult your local power company or a qualified electrician WARNING Grounding and Polarization A Do not force your Monster PowerCenter plug into an outlet that is not designed to accept a three wire grounded type AC plug a three prong plug This plug is designed to be inserted into a grounded type outlet only If this plug doesn t fit directly inside your outlet do not attempt to force it into the outlet Never attempt to dismantle the plug in any way or to alter the power cord Do not attempt to defeat the grounding feature by using a 3 to 2 prong adaptor If you have questions about grounding consult your local power company or a qualified electrician B If you use rooftop devices such as satellite dishes antennas or any other component with wire that connects to your Monster PowerCenter be sure the wire s is properly grounded Use grounding techniques specified in Section 810 of the National Electrical Code NEC ANSI NFPA 70 in Canada Part 1 of the Canadian Electrical Code This protects against voltage surges and static charges C Do not place any antenna near overhead power lines or any othe
24. TION OF DATA LOSS IS NOT COVERED AND MONSTER DOES NOT ASSUME ANY LIABILITY FOR ANY INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES UNDER THIS LIMITED WARRANTY GENERAL PROVISIONS CHOICE OF LAW JURISDICTION This Limited Warranty and any disputes arising out of or in connection with this Limited Warranty Disputes shall be governed by the laws of the State of California USA excluding conflicts of law principles and excluding the Convention for the International Sale of Goods The courts located in the State of California USA shall have exclusive jurisdiction over any Disputes OTHER RIGHTS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE AND JURISDICTION TO JURISDICTION AND WHICH SHALL NOT BE AFFECTED BY THIS LIMITED WARRANTY THIS WARRANTY EXTENDS ONLY TO YOU AND CANNOT BE TRANSFERRED OR ASSIGNED If any provision of this Limited Warranty is unlawful void or unenforceable that provision shall be deemed severable and shall not affect any remaining provisions In case of any inconsistency between the English and other versions of this Limited Warranty the English version shall prevail REGISTRATION Please register Your Product at MonsterPower com Failure to register will not diminish Your warranty rights SPECIFICATIONS TABLE Lifetime means the lifetime of the original individual purchaser of the Product or for as long as the original individual purchaser
25. You the Product new and in its original packaging Connected Equipment means any device that is i generally suited to be used with the Product or products of the same kind ii meets the requirements of all applicable laws and safety standards iii contains only parts manufactured sold or recommended by the original manufacturer of the Connected Equipment and iv has not been altered tampered with or modified by any person other than its manufacturer or service personnel authorized or recommended by the manufacturer of the Connected Equipment Connected Equipment Damage means physical damage caused to Connected Equipment due to a Product Defect i by a transient AC power cable telephone or lightning surge while connected to a properly installed Product ii not by a defect or unrelated damaging of the Connected Equipment or a surge spike or lightning strike through a source medium or connection other than through the Product and iii does not extend to loss of data or consequential indirect or special damages resulting from the Connected Equipment Damage Fair Market Value FMV means the fair market value of the Connected Equipment at the time Connected Equipment Damage occurs Formal Warranty Claim means a claim made in accordance with the section Formal Warranty Claims herein Maximum Coverage Amount means the maximum amount that Monster will pay to You under this Limited Warranty for Connected Equipment Damages an
26. ar un lectricien qualifi Remarque importante Protection et alimentation ad quates Pour prot ger compl tement votre quipement contre les surtensions lectriques chaque cable d alimentation c a chaque c ble coaxial et chaque ligne t l phonique et thernet du syst me doit tre reli au PowerCenter appropri Remarque importante Protection ad quate et garantie limit e sur l quipement branch La garantie limit e sur l quipement branch sera invalide si un c ble c a coaxial t l phonique ou Ethernet ou un fil de raccordement vid o ou audio de l quipement provient d un appareil qui n est pas reli au PowerCenter La garantie limit e sur l quipement branch sera invalide si le PowerCenter est utilis dans un environnement d installation mobile Consultez la section Informations sur la garantie de ce manuel de l utilisateur pour les d tails importants NOTE DE LA DIRECTION DE MONSTER MERCI vous tre procur le PowerCenter de r f rence professionnel de Monster Power Signature PRO 5100 concu pour vous offrir la meilleure performance et le plus complet systeme de protection de cin ma maison et audio vid o disponible Le Signature PRO 5100 est concu pour l installateur professionnel de syst mes audio vid o haut de gamme les milieux de l enregistrement et des tourn es ainsi que pour beaucoup d autres milieux o la qualit du son et de l image s impose Les caract ristiques am lior e
27. at you want to turn on and off the PowerCenter s Switched Outlets when it is turned on Remote AC In Control Hook Up This feature connects your PowerCenter to an automated Home Theater control system or allows another component with an AC outlet connection for example an AV receiver or preamplifier for example to automatically turn on and off your PowerCenter A Insert the Remote AC IN Control cord s female plug into the AC IN 120V connection B Insert the Remote AC IN Control cord s 2 prong male plug into a switched AC power outlet on the component AV receiver or preamplifier When this device is turned on the outlets programmed as Switched On on the PowerCenter will turn on immediately The outlets programmed as Switched On After Delay will turn on after the set time delay Remote DC Out Control Hook Up This feature connects your PowerCenter to an automated Home Theater control system or allows the PowerCenter to automatically turn on and off another component with a Remote DC In connection A Plug one end of the 1 8 mini plug into the corresponding Remote DC Out connection on the PowerCenter B Plug the other end of the 1 8 mini plug into the Remote DC In connection on the component that you want the PowerCenter to control Note This component may not label the connection DC In Make sure it accepts control voltages between 3 30 volts DC Note 1 One 1 1 8 mini plug cable is supplied with the Powe
28. cation facilit e de vos appareils GUIDE DE RACCORDEMENT Raccordement aux prises num riques Ces prises incluent un circuit de filtrage sp cifiquement concu pour r duire les interf rences entre vos quipements num riques A Attachez une tiquette d identification Monster Power au cordon d alimentation de chaque appareil avant de le brancher dans la prise appropri e du PowerCenter identifi e par un code de couleurs B Branchez le cordon d alimentation de chaque appareil c ble satellite DVD etc dans la prise correspondante du PowerCenter Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique ou audio de puissance et branchez les dans la prise correspondante pour obtenir le meilleur r sultat NOTE IMPORTANTE Il n y a aucun danger brancher un appareil audio analogique vid o ou de puissance dans une prise num rique Cependant pour obtenir le meilleur rendement nous recommandons de ne brancher que des composants num riques dans les prises num riques oc We oc lt O 35 9000 ee UT 2 0000 E Prises num riques GUIDE DE RACCORDEMENT Raccordement aux prises vid o Ces prises incluent un circuit de filtrage sp cifiquement concu
29. cheur DC Out 2 REMOTE TURN ON OFF De l appareil Vers les appareils de contr le de contr le Vers les appareils de contr le De l appareil Vers les appareils de contr le de contr le GUIDE DE RACCORDEMENT Montage de votre PowerCenter dans une armoire Ce PowerCenter de Monster comprend les plaques d intallation fix es au chassis pour installation dans une armoire d quipement de dimension courante Placez le PowerCenter dans l armoire et alignez les trous correspondants Ins rez des vis de montage non incluses et serrez dans le sens des aiguilles d une montre ma CO 9 Fr M ue 1 Trous ME 1 2 gt o Trous d installation d installation d armoire me d armoire 9 2 8 58 f 0 1 6 C Signature PRO 5100 E Ps GUIDE DE RACCORDEMENT Ce PowerCenter de Monster comprend des poign es d armoire amovibles Pour ajouter des poign es d armoire ce PowerCenter A Retirez les plaques d coratives sur le cot avant droit et gauche du PowerCenter l aide d un tournevis en le placant sur le dessus des vis et en les tournant dans le sens antihoraire Il y a un total de deux vis qui sont galement utilis es pour fixer les poign es d armoire au PowerCenter B pr sent placez une poign e pa
30. cted components This will extend the PowerCenter s life while providing the system protection you need MONSTER PATENTED CLEAN POWER STAGES Monster Clean Power performs two tasks that are vital to maintaining optimum home theater performance 1 noise filtration and 2 noise isolation The higher the Clean Power stage number 1 5 the more sophisticated and advanced the filters are that reject noise generated on the AC powerline In addition the higher the Clean Power stage number the more isolation that exists between connected equipment for maximum rejection of component generated noise Monster PowerCenters featuring Clean Power circuitry are each designated with a Clean Power Stage The Signature PRO5100 incorporates Monster Clean Power Stage 4 v 2 0 circuitry which filters both AC powerline noise and reduces noise generated by your connected equipment Clean Power Stage 4 features five ultra advanced isolated filters that include analog audio video and digital plus an ultra high current audio filter to provide for the best possible AC powerline noise rejection and inter component isolation for improved component generated noise rejection of these features make the Signature PRO 5100 ideal for your home theater system To learn more about patented Monster Clean Power and the complete product family of PowerCenters voltage stabilizers and amplifiers please visit MonsterPower com Actual spectrum analyzer AC power line filtere
31. d by photo of AC power pollution Monster Clean Power THE MINDS BEHIND THE MONSTER POWERCENTER DESIGN Richard Marsh There are few experts able to solve the complex problems associated with AC power and complex home theater systems Richard Marsh is one of these illustrious few He has designed best selling power conditioning components costing more than 3 000 and now brings his expertise to Monster Power Richard developed Monster s patented Clean Power circuitry which is incorporated into many of Monster s PowerCenters He is also responsible for several other groundbreaking designs Richard s background and research into amplifier and capacitor design led to his development of the Servo DC feedback concept in power amplifiers a concept that is used by virtually every amplifier manufacturer today His status as both the inventor of the MultiCap internal bypass capacitor and as the driving force behind the high end audio balanced circuit design concept has influenced the audiophile community for years Richard is responsible for some of the high end audio world s most respected product designs essays and articles and has contributed to The Absolute Sound and Audio magazines He is included in Who s Who in the West Demian Martin Demian Martin has been solving complex AC power problems for several years As a technical consultant for successful paper and steel mills Demian helped create several innovative AC power solutio
32. d is defined in relation to each Product in the Specifications Table below Product means a Product i that is listed in the Specifications Table below ii that You bought from an Authorized Dealer new and in its original packaging and iii whose serial number if any has not been removed altered or defaced Product Defect means an inadequacy of the Product that existed at the time when You received the Product from an Authorized Dealer and that causes a failure of the Product to perform in accordance with Monster s documentation accompanying the Product unless such failure has been caused completely or partly by a any use other than Adequate Use b transportation neglect misuse or abuse by anyone other than Monster s employees c alteration tampering or modification of the product by anyone other than a Monster employee d accident other than a malfunction that would otherwise qualify as a Product Defect e maintenance or service of the Product by anyone other than a Monster employee f exposure of the Product to heat bright light sun liquids sand or other contaminants or 9 acts outside the control of Monster including without limitation acts of God fire storms excluding lightning surges earthquake or flood Warranty Period means the time period during which Monster must have received Your Formal Warranty Claim The different Warranty Periods related to Product Defects and Connected Equipment Damage are defined
33. e antenne pr s d une ligne lectrique a rienne ni pr s d aucun autre circuit lectrique Ne touchez aucune ligne lectrique ni circuit lectrique Ce faisant vous pourriez vous causer de graves blessures physiques et ventuellement la mort MISE EN GARDE Liquides Eviter les chocs lectriques A N utilisez pas votre PowerCenter de Monster si un liquide a t renvers sur ou l int rieur de l appareil B N utilisez pas votre PowerCenter de Monster pr s d un endroit o l on retrouve de l eau ou de la pluie par exemple un bain une amp cuisine ou un vier MISE EN GARDE S curit du cordon d alimentation A Lorsque vous acheminez le cordon d alimentation c a de votre PowerCenter ne le placez pas dans des zones de passage par exemple un couloir une entr e de porte ou un plancher Ne cr ez pas un risque de tr bucher sur le cordon d alimentation B Si l enveloppe protectrice du cordon d alimentation commence se d chirer ou s effilocher exposant ainsi le filage interne le blindage etc d branchez le de la source d alimentation et cessez imm diatement d utiliser le PowerCenter de Monster Consultez la section Informations sur la garantie de ce manuel de l utilisateur pour les d tails importants MISE EN GARDE Pr cautions en cas d orage En cas d orage lectrique nous vous conseillons de d brancher votre PowerCenter de Monster il n y a toutefois aucune n cessit de d brancher les appa
34. e comme suit TV CABLE D une connexion d antenne Vers la t l vision le d codeur du cable correctement mise la terre D une connexion d antenne Vers le r cepteur de satellite correctement mise la terre D une connexion d antenne Vers la t l vision correctement mise la terre Note Vous aurez besoin de c bles coaxiaux suppl mentaires pour connecter le Signature PRO 5100 vos quipements GUIDE DE RACCORDEMENT Raccordement aux connexions t l phoniques Les connexions t l phoniques prot gent la ligne t l phonique contre les surtensions et contre les pics de tension Ce PowerCenter int gre galement un doubleur de prise t l phonique trois voies Prot gez les connexions t l phoniques comme suit PHONE LINE SURGE PROTECTION De la pri Elus IOL IN OUT 1 OUT 2 OUT 3 Vers le r cepteur de satellite Vid o num rique Enregistreuse DVR ou le t l phone Note Le Signature PRO 5100 n est pas pr vu pour connecter un t l phone deux lignes sur un connecteur 4 pins RJ1 ap GUIDE DE RACCORDEMENT Raccordement aux connexions Ethernet Ces connexions prot gent la ligne Ethernet contre les surtensions et contre les pics de tension Prot gez les connexions Ethernet comme suit ETHERNET LINE SURGE PROTECTION D une connexion De la connexion Ethernet votre quipemen
35. e other than an Authorized Dealer SCOPE OF THIS LIMITED WARRANTY PRODUCTS Product contained a Product Defect when You bought it from an Authorized Dealer and Monster receives a Formal Warranty Claim from You within two 2 months after You discover such Product Defect or should have discovered it if such Product Defect was obvious and before the end of the Warranty Period for Product Defects applicable to the affected Product then Monster will provide You with one of the following remedies Monster will 1 repair or at Monster s sole discretion replace the Product or 2 refund to You the purchase price You paid to the Authorized Dealer for the affected Product if repair or replacement is not commercially practicable or cannot be timely made CONNECTED EQUIPMENT DAMAGE Monster will also provide You with a remedy regarding Connected Equipment Damage if i You have a claim under the Limited Warranty for Products because of a Product Defect that causes Connected Equipment Damage despite Adequate Use and ii Monster receives a Formal Warranty Claim from You before the end of the Warranty Period for Connected Equipment Damage applicable to the affected Product If the conditions listed in the preceding sentence are met Monster will provide You with one of the following remedies provided that Monster may decide at its sole discretion which of the three remedies it provides Monster will 1 replace the damaged Connected Equipment 2 pay t
36. e the PowerCenter s AC power plug is plugged into a properly grounded 120 volts nominal wall outlet In some households a wall switch may need to be thrown to make the wall plug active Try turning on the light switches located near the wall unit Too many devices are connected causing an overload tripping the Thermal Circuit Breaker Press the PowerCenter Thermal Circuit Breaker button in to reset Please allow 10 minutes before attempting to reset If you reset too soon the breaker will prematurely sense power overload and not allow unit to operate f the Circuit Breaker continues to trip try moving one or more components to another PowerCenter You may be drawing too much current through one PowerCenter Symptom TROUBLESHOOTING Possible Cause Remedy Component is not receiving power The component is plugged into a switched outlet and the PowerCenter has not been turned On e Turn the PowerCenter On Or plug the component into an Unswitched outlet The PowerCenter is plugged into a Switched outlet but power on the component is not On In some instances a component plugged into a switched outlet won t receive power when the PowerCenter is turned On unless the component power is also switched On Turn the component power On Speakers emit a humming or buzzing noise The PowerCenter is sharing AC power with equipment that is not properly grounded
37. ent e Remarque l appareil est r gl en usine avec toutes les paires de prises r gl es en mode commut SWITCHED ON GUIDE DE RACCORDEMENT R glage de l alarme sonore de surtension et de sous tension Cette fonction active ou d sactive l alarme sonore indicant une condition d alimentation anormale sur la ligne Lorsque l alarme est en mode activ ENABLE l alarme sonnera lorsque la tension d alimentation d passe 130V ou tombe sous 100V A Appuyez sur le bouton MENU jusqu ce que l afficheur indique le r glage de l alarme B Appuyez sur SELECT pour alterner entre ENABLE activ et DISABLE d sactiv Figure 5 Figure 6 GUIDE DE RACCORDEMENT R glage de l extinction automatique lors de surtension et de sous tension Cette fonction active ou d sactive l extinction automatique lors d une condition d alimentation anormale sur la ligne Lorsque la fonction est en mode activ ENABLE l appareil s teindra automatiquement lorsque la tension d alimentation d passe 134V ou tombe sous 96V A Appuyez sur le bouton MENU jusqu ce que l afficheur indique Figure 7 Figure 8 B Appuyez sur SELECT pour alterner entre ENABLE activ et DISABLE d sactiv GUIDE DE RACCORDEMENT Raccordement aux connexions coaxiales Les connexions coaxiales prot gent les entr es coaxiales contre les surtensions et les pics de tension Prot gez les connexions du c ble du satellite et de l antenn
38. er cord Receiver Processor etc into the PowerCenter s corresponding outlet For components not listed determine if they are audio video digital or ultra high current audio and use a corresponding outlet for best performance IMPORTANT NOTE It does not harm video digital or high current audio components to be connected to the analog audio outlets However for best performance we recommend plugging in only analog audio components to the analog audio outlets lt oc Analog Audio Outlets m High Current Audio Outlets HOOK UP GUIDE Ultra High Current Audio Outlet Hook Up These outlets are designed to deliver maximum current to power hungry components like amplifiers and pre amplifiers A Attach a Monster Power identification label to each component s power cord before you plug it into the appropriate color coded PowerCenter outlet B Plug each component s power cord Amplifier etc into the PowerCenter s corresponding outlet For components not listed determine if they are audio video digital or ultra high current audio and use a corresponding outlet for best performance IMPORTANT NOTE It does not harm analog audio video or digital components to be connected to the ultra high current audio outlets However for best performance we recommend p
39. es incluent un circuit de filtrage sp cifiquement concu pour r duire les interf rences entre vos quipements num riques Filtre vid o Ces prises incluent un circuit de filtrage sp cifiquement concu pour r duire les interf rences entre vos quipements vid o Filtre audio analogique Ces prises incluent un circuit de filtrage sp cifiquement concu pour r duire les interf rences entre vos quipements audio Filtre audio de puissance Ces prises incluent un circuit de filtrage sp cifiquement concu pour r duire les interf rences entre vos quipements audio haute puissance tels que des amplificateurs et des pr amplificateurs Protection pour le cable de t l vision Protege le cable de t l vision contre les surtensions Le cable coaxial se branche sur l entr e La prise de sortie coaxiale se branche sur la t l vision ou sur le d codeur du c ble Protection de syst me satellite Prot ge la connexion satellite contre les surtensions Le cable coaxial de l antenne satellite se branche sur l entr e La prise de sortie coaxiale se branche sur l entr e du d codeur satellite 35 36 37 38 39 40 41 42 43 44 45 46 Protection d antenne Prot ge la connexion d antenne contre les surtensions Le c ble coaxial de l antenne de radio se branche sur l entr e La prise de sortie coaxiale se branche sur l entr e d antenne Contr le de l alimentation d entr e c c DC In distance
40. features a patent pending color coding system which identifies where each component should be connected As fellow audiophiles and videophiles Monster designed the Signature PRO 5100 to help you get the best possible sound and picture and we hope you enjoy it as an integral part of your A V and home theater systems Noel Lee The Head Monster MONSTER EXCLUSIVE T2 TECHNOLOGY The Monster Power Signature PRO 5100 PowerCenter features exclusive Monster T2 technology T2 is an active electronic microprocessor controlled circuit that sits in front of the surge protection circuitry in select Monster Power products T2 monitors the line neutral and ground lines and automatically disconnects the PowerCenter from the AC power line when a long duration low voltage sag or high voltage swell occurs continuous voltage below 80Vrms or above 132Vrms When the voltage sags or swells to these potentially damaging levels ultra fast T2 auto disconnect protection circuitry shuts down the Monster PowerCenter for 15 seconds When the under voltage or over voltage condition returns to normal T2 reconnects the PowerCenter to full operation after 15 seconds If the fault condition does not clear the T2 comparator circuit keeps the unit shut down Unlike ordinary power management devices T2 will shut down your PowerCenter before the MOVs Metal Oxide Varistors and thermal fuses sense an overload condition and sacrifice themselves to protect your conne
41. handle over the screw holes place one screw in each of the two holes of the rack handles align the screw holes with the screws and using a screwdriver turn it clockwise until the rack handle rests firmly against the PowerCenter and a tight connection is made If a tight connection is not made remove the screw from the PowerCenter and repeat Step B C Repeat this step with the second rack handle To remove the rack handles from this PowerCenter A Remove the rack handles on the front right and front left sides of the PowerCenter by using a screwdriver placing it in each of the two holes in the rack handles aligning the screw holes with the screws and turning it counterclockwise There are two screws attaching each rack handle four screws total which will also be used to fastening the decorative plates to the PowerCenter B Now place a decorative plate over the screw holes place one screw in each of the two holes in the decorative plates align the screw holes with the screws and using a screwdriver turn it clockwise until the decorative plate rests firmly against the PowerCenter and a tight connection is made If a tight connection is not made remove the screw from the PowerCenter and repeat Step B C Repeat this step with the second rack handle Symptom The PowerCenter is not receiving power TROUBLESHOOTING Possible Cause The PowerCenter is not turned On Remedy e Turn the PowerCenter switch on Make sur
42. ightness of the alphanumeric display Ultra High Current PowerLine 400 AC Power Cable High density double shielded AC power cord specially designed to maximize power transfer Ground Screw Provides a ground reference point for any ungrounded components Resettable 20 Amp Circuit Breaker Protects the PowerCenter from continuous power overload Monster Power Color Coded Audio Video ID labels For easy identification of your components HOOK UP GUIDE Digital Outlet Hook Up These outlets have a special filter circuit that is optimized to reduce interference to your digital components A Attach a Monster Power identification label to each component s power cord before you plug it into the appropriate color coded PowerCenter outlet B Plug each component s power cord Cable SAT DVD etc into the PowerCenter s corresponding outlet For components not listed determine if they are audio video digital or ultra high current audio components and use a corresponding outlet for best performance IMPORTANT NOTE It does not harm analog audio video or high current audio components to be connected to the digital outlets However for best performance we recommend plugging in only digital components to the digital outlets BE on Ow PHONE LINE SURGE PROTECTION
43. ir This pair will be live once the PowerCenter is powered up by pressing the front panel ON OFF button or triggered by an external signal HOOK UP GUIDE C Set the Outlet Pair to SWITCHED ON AFTER DELAY Press MENU until the display shows the status of the Analog outlet pair Press the SELECT button until the time delay changes to the required delay in seconds before the outlet pair will turn on after the ON OFF button is pressed HN When the PowerSource is SWITCHED ON by pressing the front panel ON OFF button or by an external trigger signal the outlet pair will go live after the time delay set as described above 20 seconds in this case The outlet pair with the maximum time delay setting will still turn off immediately when the ON OFF button is pressed or when triggered by an external signal D Set the Outlet Pair to UNSWITCHED Always On Press the MENU button until the display shows the status of the Analog outlet pair Press the SELECT button until you see the display ANA UN Once UNSWITCHED is selected any component plugged into those outlets will receive power continuously as long as your PowerCenter is plugged into a 120 volt outlet that is on Note The unit is shipped with all outlet pairs set to SWITCHED ON HOOK UP GUIDE Over Voltage and Under Voltage Audible Alarm Setting This feature enables or disables the audible alarm indicating an abnormal line voltage condition When set to ENABLE the unit will
44. iscovered it if such Product Defect was obvious and before the end of the Warranty Period for Product Defects applicable to the affected Product then Monster will provide You with one of the following remedies Monster will 1 repair or at Monster s sole discretion replace the Product or 2 refund to You the purchase price You paid to the Authorized Dealer for the affected Product if repair or replacement is not commercially practicable or cannot be timely made CONNECTED EQUIPMENT DAMAGE Monster will also provide You with a remedy regarding Connected Equipment Damage if i You have a claim under the Limited Warranty for Products because of a Product Defect that causes Connected Equipment Damage despite Adequate Use and ii Monster receives a Formal Warranty Claim from You before the end of the Warranty Period for Connected Equipment Damage applicable to the affected Product If the conditions listed in the preceding sentence are met Monster will provide You with one of the following remedies provided that Monster may decide at its sole discretion which of the three remedies it provides Monster will 1 replace the damaged Connected Equipment 2 pay to repair the damaged Connected Equipment or 3 pay You the FMV of the Connected Equipment provided that such payments shall not exceed i the Maximum Coverage Amount for the Product or ii the actual damage having arisen from power surges due to a Product Defect NOTE COMPENSATION FOR RESTORA
45. la conception de fusion laser au Lawrence Livermore National Laboratory puis quelques ann es plus tard musicien professionnel Noel a invent ou co invent plus de 250 brevets am ricains et internationaux et a men la croissance spectaculaire des compagnies du groupe Monster dans plus de 80 pays Monster Power est pour Noel la r alisation d une vision longuement entretenue d offrir des solutions d alimentation abordables qui d livrent le meilleur son et la meilleure image possibles CARACT RISTIQUES DE MONSTER SIGNATURE PRO5100 POWERCENTER SIGNATURE PRO 5100 VUE AVANT 219999 L amp 2 2 o 606 O Si igrature PRO 5100 12 Professional Reference Powercenter with Clean Power Stage 4 v 2 0 Filtering p Ho io 8 LU ES He e _ CARACT RISTIQUES DE MONSTER SIGNATURE PRO5100 POWERCENTER SIGNATURE PRO 5100 VUE ARRI RE 60 Monster Power PRO 5100 ID Labels 95 arrete nd tne coron pawar eart 4 DVD TV PROJECTOR TV PROJECTOR DVD DVD TV PROJECTOR TV PROJECTOR
46. ler le PowerCenter distance La pile de la t l commande de l appareil que vous utilisez pour contr ler la fonction d alimentation distance est trop faible Remplacez la pile alimentant la t l commande de votre appareil Branchez l appareil dans une prise de 120 V nominal correctement mise la terre l appareil que vous souhaitez utiliser pour activer la fonction de commande distance du PowerCenter n est pas branch dans une prise de 120 V nominal correctement mise la terre Branchez l appareil dans une prise de 120 V nominal correctement mise la terre Sympt me Le t moin Timed de fonctionnement de l alimentation s quentielle est teint D PANNAGE Cause possible Vous utilisez la fonction de contr le des prises distance sans avoir branch le cordon dans l appareil que vous souhaitez utiliser pour contr ler le PowerCenter Solution Branchez la prise du PowerCenter dans l appareil que vous souhaitez utiliser pour contr ler le PowerCenter distance La pile de la t l commande de l appareil que vous utilisez pour contr ler la fonction d alimentation distance est trop faible Remplacez la pile alimentant la t l commande de votre appareil L appareil que vous souhaitez utiliser pour activer la fonction de commande distance du PowerCenter n est pas branch dans une prise de 120 V nominal correctement mise la terre
47. lit labor par lui ont influenc la communaut audiophile pendant des ann es Richard est la t te de plusieurs inventions et concepts travaux de recherche et articles r put s dans le monde de l audio de haute fid lit Il a contribu aux magazines The Absolute Sound et Audio 11 fait partie du Who s Who in the West Demian Martin Demian Martin a travaill sur la r solution de probl mes d alimentation complexes pendant des ann es En tant que consultant technique dans les industries du papier et de l aci rie Demian a particip la cr ation de plusieurs solutions d alimentation innovatrices I a d velopp des techniques pour am liorer de facon drastique l efficacit des syst mes de contr le des moteurs de puissance jusqu 50 000 Watts permettant ces usines d effectuer des conomies cons quentes li es au rendement des syst mes Demian fut galement l un des fondateurs de Spectral Audio et le chef concepteur de plusieurs de leurs concepts pilotes pour des amplificateurs des convertisseurs num riques analogiques et d autres inventions dans le domaine de l audio de haute fid lit apporte maintenant son expertise l quipe de recherche et de d veloppement d lite de Monster Power Noel Lee Noel Lee la direction de Monster est mieux connu pour avoir popularis le concept de c ble audio de haute qualit il y a 25 ans avec la cr ation de Monster Cable Au d part ing nieur dans
48. ll prevail REGISTRATION Please register Your Product at MonsterPower com Failure to register will not diminish Your warranty rights SPECIFICATIONS TABLE Lifetime means the lifetime of the original individual purchaser of the Product or for as long as the original individual purchaser owns the Product whichever is less in time Product Warranty Period Maximum Warranty Period for Connected Model No for Products Coverage Amount Equipment Damage Signature FORMAL WARRANTY CLAIM HOW TO MAKE A CLAIM In the event damage has occurred to Products You must follow these instructions 1 Call Monster within two 2 months after You discover a Product Defect or should have discovered it if such Product Defect was obvious 2 Give a detailed explanation of how the damage occurred 3 Obtain a Return Authorization Number 4 Upon receipt of a claim form which may be sent to You after You filed Your Formal Warranty Claim fill out the claim form entirely 5 Return the Products shipping prepaid by You to be refunded if You are entitled to a remedy under the Scope of this Limited Warranty to Monster for verification of damage along with a copy of Your original sales receipts and proof of purchase UPC label or packing slip for such Products the completed claim form and printed Return Authorization Number on the outside of the return package the claim form will include instructions for return FURTHER PROCEEDINGS Mon
49. lugging in only high current audio components to the ultra high current audio outlets NETWORK SURGE PROTECTION PHONE LINE SURGE PROTECTION HOOK UP GUIDE Outlet Programming All PowerCenter outlets on the rear panel are programmable via the menu and select buttons on the front panel To set up each outlet pair use the front panel MENU and SELECT buttons to choose between SWITCHED ON SWITCHED ON AFTER DELAY and UNSWITCHED Always On independently for each outlet pair You can change the settings whenever you like Using the outlet pair labeled ANALOG FILTER as an example the following diagrams illustrate how it s done A Power up the PowerCenter Press the ON OFF switch one time to power the unit and start the process Once the PowerCenter is on the display will show the AC line voltage Note The power on process may take up to 60 seconds since any outlet pair can be configured as SWITCHED ON AFTER DELAY You can see any outlet pair s power status by referring to its indicator on the front panel B Set Outlet Pair to SWITCHED ON Press MENU until the second line display shows the status of the ANALOG outlet pair Press the SELECT button until the time delay changes to 0 zero ANA The 0 zero time delay setting indicates SWITCHED ON mode for the ANALOG outlet pa
50. moire Sympt me D PANNAGE Cause possible Solution Le PowerCenter n est n est pas aliment Le PowerCenter n est pas allum e Allumez le PowerCenter Assurez vous que le cordon lectrique du PowerCenter est bien branch dans une prise murale de 120 volts nominal correctement mise la terre Certaines prises murales sont activ es par un interrupteur Allumez les interrupteurs muraux situ s proximit de la prise Trop d appareils sont connect s sur le PowerCenter causant ainsi une surcharge qui d clenche le disjoncteur thermique Appuyez sur le disjoncteur thermique du PowerCenter pour l enclencher Attendez 10 minutes avant de r initialiser le disjoncteur Si vous le r initialisez trop 161 le disjoncteur d tectera pr matur ment une surcharge et se d clenchera nouveau ne permettant pas au syst me de fonctionner Si le disjoncteur continue se d clencher d chargez un ou plusieurs des quipements vers un second PowerCenter II se peut en effet que les appareils branch s consomment trop de courant pour un seul PowerCenter Sympt me D PANNAGE Cause possible Solution Un appareil n est pas aliment L appareil est branch dans une prise commut e par le PowerCenter qui n est pas allum Allumez le PowerCenter Ou branchez l appareil dans une prise non commut e Le PowerCenter est branch la prise commut e d un a
51. n num riques de l appareil sont mises sous tension Indicateur du filtre audio Indique si les prises d alimentation audio de l appareil sont mises sous tension Indicateur du filtre de puissance Indique si les prises d alimentation de puissance de l appareil sont mises sous tension Prises d alimentation non commut es Ces prises sont situ es l avant du PowerCenter pour un acc s facilit Elles incluent un circuit de filtrage sp cifiquement concu pour les appareils audio puissance lev e Ampoule DEL le panneau avant du PowerCenter Pour l aspect pratique cette lampe se r tracte dans le PowerCenter Bouton gradateur Dimmer Ajuste la luminosit des lampes DEL Suppression des surtensions sur la connexion thernet Prot ge la ligne t l phonique r seau contre les surtensions et contre les pics de tension Suppression des surtensions sur la ligne t l phonique Prot ge la ligne t l phonique r seau contre les surtensions et contre les pics de tension Affichage num rique de la tension d entr e et de l amp rage utilis Indique la tension d entr e et le d bit en amp res T moin de fonctionnement des prises Indique si les prises d alimentation situ es du c t de l indicateur sont mises sous tension Filtre num rique 1 Ces prises incluent un circuit de filtrage sp cifiquement concu pour r duire les interf rences entre vos quipements num riques Filtre num rique 2 Ces pris
52. ns He developed techniques to dramatically improve the efficiency of these factories high power motor control systems up to 50 000 watts helping them avoid the costly premiums many factories must pay for AC power inefficiency Demian was also the co founder of Spectral Audio and was the chief designer of their many pioneering designs for amplifiers D A converters and other high end audio designs He now brings his expertise to Monster Power s elite research and development team Noel Lee Noel Lee The Head Monster is best known for popularizing the concept of high performance audio cable 25 years ago with his creation of Monster Cable Originally a laser fusion design engineer at Lawrence Livermore National Laboratory and later a touring musician Noel has invented or co invented over 250 U S and international patents and drives the explosive growth of The Monster Group companies in more than 80 countries worldwide Monster Power is Noel s realization of a long nurtured vision of making affordable power solutions that deliver the best possible sound and picture MONSTER SIGNATURE PRO 5100 POWERCENTER FEATURES SIGNATURE PRO 5100 FRONT VIEW Ol w x 1 1 1 1 1 1 1 1 1 1 1 1 1 2 49 9 0 40 EA Rem RE EE x Si igrature PRO 5100 7 lte Professional Reference Powercenter with Clean Power Stage 4 v 2 0 Filtering
53. o repair the damaged Connected Equipment or 3 pay You the FMV of the Connected Equipment provided that such payments shall not exceed i the Maximum Coverage Amount for the Product or ii the actual damage having arisen from power surges due to a Product Defect NOTE COMPENSATION FOR RESTORATION OF DATA LOSS IS NOT COVERED AND MONSTER DOES NOT ASSUME ANY LIABILITY FOR ANY INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES UNDER THIS LIMITED WARRANTY GENERAL PROVISIONS CHOICE OF LAW JURISDICTION This Limited Warranty and any disputes arising out of or in connection with this Limited Warranty Disputes shall be governed by the laws of the State of California USA excluding conflicts of law principles and excluding the Convention for the International Sale of Goods The courts located in the State of California USA shall have exclusive jurisdiction over any Disputes OTHER RIGHTS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE AND JURISDICTION TO JURISDICTION AND WHICH SHALL NOT BE AFFECTED BY THIS LIMITED WARRANTY THIS WARRANTY EXTENDS ONLY TO YOU AND CANNOT BE TRANSFERRED OR ASSIGNED If any provision of this Limited Warranty is unlawful void or unenforceable that provision shall be deemed severable and shall not affect any remaining provisions In case of any inconsistency between the English and other versions of this Limited Warranty the English version sha
54. ol 3 30V DC Remote DC Out Control 12V DC 100mA Dimensions Width 17 125 434mm Height with Feet 5 25 133 35mm Height without Feet 5 75 146 05mm Depth with Handle 145 368 3mm Depth without Handle 16 5 419 1mm LIMITED WARRANTY FOR CONSUMERS Monster LLC 7251 West Lake Mead Blvd Las Vegas NV USA Monster extends You this Limited Warranty Statutory or common law may provide You with additional rights or remedies which shall not be affected by this Limited Warranty DEFINITIONS Adequate Use means use of the Product and Connected Equipment i within a home or dwelling ii for private as opposed to commercial purposes iii in conformance with all applicable local state or federal law code or regulations including without limitation building and or electrical codes iv in accordance with manufacturer recommendations and or instructions in the materials and documentation that accompany the Product and any Connected Equipment v with proper electrical grounding vi with proper and direct connection between the Product and an AC power source that has protective grounding excluding gas or diesel powered generators vii with cable or telephone lines to any Connected Equipment properly connected to the Product and viii without a connection in a daisy chain fashion to or with any extension cord surge suppressor power strip uninterruptible power supply UPS or other
55. owns the Product whichever is less in time Product Warranty Period Maximum Warranty Period for Connected Model No for Products Coverage Amount Equipment Damage Signature FORMAL WARRANTY CLAIM HOW TO MAKE A CLAIM In the event damage has occurred to Products You must follow these instructions 1 Call Monster within two 2 months after You discover a Product Defect or should have discovered it if such Product Defect was obvious 2 Give a detailed explanation of how the damage occurred 3 Obtain a Return Authorization Number 4 Upon receipt of a claim form which may be sent to You after You filed Your Formal Warranty Claim fill out the claim form entirely 5 Return the Products shipping prepaid by You to be refunded if You are entitled to a remedy under the Scope of this Limited Warranty to Monster for verification of damage along with a copy of Your original sales receipts and proof of purchase UPC label or packing slip for such Products the completed claim form and printed Return Authorization Number on the outside of the return package the claim form will include instructions for return FURTHER PROCEEDINGS Monster will determine whether a Product Defect existed Monster may at its discretion direct You to obtain a repair estimate at a service center If a repair estimate is required You will be instructed on how to properly submit the estimate and the resulting invoice to Monster for payment Any fees
56. pour r duire les interf rences entre vos quipements vid o A Attachez une tiquette d identification Monster Power au cordon d alimentation de chaque appareil avant de le brancher dans la prise appropri e du PowerCenter identifi e par un code de couleurs B Branchez le cordon d alimentation de chaque appareil TV moniteur magn toscope dans la prise correspondante du PowerCenter Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique ou audio de puissance et branchez les dans la prise correspondante pour obtenir le meilleur r sultat NOTE IMPORTANTE I n y a aucun danger brancher un appareil audio analogique num rique ou de puissance dans une prise vid o Cependant pour obtenir le meilleur rendement nous recommandons de ne brancher que des composants vid o dans les prises vid o N NETWORK SURGE PROTECTION SE um On in Fn IE EE En 2 t E E E Si MONSTER 1 BOWER PROFESSIONAL FOWERCENTERY une 200 US Ph TUT Ste St Prises vid o GUIDE DE RACCORDEMENT Raccordement aux prises audio analogique Ces prises incluent un circuit de filtrage sp cifiquement concu pou
57. ppareil qui est teint Dans certains cas un appareil branch sur une prise commut e par le PowerCenter ne sera pas aliment lorsque lePowerCenter est allum moins que l appareil soit aussi allum Allumez l appareil Les haut parleurs mettent un bourdonnement Le PowerCenter partage son alimentation c a avec un appareil qui n est pas correctement mis la terre Connectez votre PowerCenter une pri murale d di e Essayez de d brancher vos appareils du PowerCenter l un apr s l autre pour voir si le bruit s arr te Si un appareil n est pas correctement mis la terre vous pouvez tenter d attacher un fil de cuivre entre le chassis de l appareil et la borne de mise la terre du PowerCenter Sympt me D PANNAGE Cause possible Solution La DEL de la prise non commut e sur le panneau avant est teinte Le PowerCenter n est pas branch Le PowerCenter est branch mais la prise n est pas aliment e Branchez le PowerCenter dans une prise de 120 V nominale correctement mise la terre et allumez le PowerCenter La DEL des prises commut es par le PowerCenter est teinte Vous utilisez la fonction de contr le des prises distance sans avoir branch le cordon dans l appareil que vous souhaitez utiliser pour contr ler le PowerCenter distance Branchez la prise lectrique du PowerCenter dans l appareil que vous souhaitez utiliser pour contr
58. r de Monster et pour conna tre l ensemble des produits des cat gories PowerCenter de stabilisateurs de tensions et d amplificateurs n h sitez pas visiter le site MonsterPower com Analyseur de spectre actuel Conduit d alimentation photo de la pollution sur filtr par Monster l alimentation c a Clean Power LES CERVEAUX DERRI RE LA CONCEPTION DU POWERCENTER DE MONSTER Richard Marsh Il n y a que peu d experts capables de r soudre les probl mes complexes associ s l alimentation et aux syst mes de cin ma maison Richard Marsh est l un d entre eux Tout au long de sa carri re il a con u les meilleurs syst mes de gestion d alimentation d une valeur de plus de 3000 et apporte maintenant son expertise Monster Power Richard a d velopp le circuit brevet Clean Power de Monster qui est int gr dans la gamme PowerCenter de Monster est galement l origine de plusieurs autres concepts r volutionnaires L exp rience de Richard dans le domaine de la recherche au niveau de la conception d amplificateurs et de condensateurs l a conduit au d veloppement du concept d asservissement courant continu et r troaction dans les amplificateurs de puissance un concept qui est aujourd hui utilis virtuellement par tous les fabricants d amplificateurs Son statut d inventeur du condensateur de d rivation interne MultiCap et la reconnaissance publique du concept de circuit audio sym trique de haute fid
59. r dessus les trous des vis placez une vis dans chacun des deux trous des poign es alignez les trous des vis avec les vis et l aide d un tournevis tournez dans le sens des aiguilles d une montre jusqu ce que la poign e s appuie fermement contre le PowerCenter et qu une solide connexion ait t faite Si la connexion n est pas solide retirez la vis du PowerCenter et r p tez l tape B C R p tez cette tape avec la seconde poign e d armoire Pour retirer des poign es d armoire de PowerCenter A Retirez les poign es d armoire des cot s avant droit et gauche du PowerCenter l aide d un tournevis en l ins rant dans les deux trous des poign es d armoire en alignant les trous avec les vis et en tournant dans le sens inverse des aiguilles d une montre Il y a deux vis retenant chaque poign e d armoire pour un total de quatre vis qui sont galement utilis es pour fixer les plaques d coratives au PowerCenter B pr sent placez une plaque d corative par dessus les trous des vis placez une vis dans chacun des deux trous dans les plaques d coratives alignez les trous des vis avec les vis et a l aide d un tournevis tournez dans le sens des aiguilles d une montre jusqu ce que la plaque s appuie fermement contre le PowerCenter et qu une solide connexion ait t faite Si la connexion n est pas solide retirez la vis du PowerCenter et r p tez l tape B C R p tez cette tape avec la seconde poign e d ar
60. r power circuit Do not touch any power line or power circuit Doing so may cause severe physical injury or possibly death WARNING Liquid Avoiding Electrical Shocks A Do not operate your Monster PowerCenter if liquid of any kind is spilled onto or inside the unit B Do not operate your Monster PowerCenter near rain or water that s spilled or contained e g bathtub kitchen or sink WARNING Power Cord Safety A When routing your Monster PowerCenter s AC power cord do not place it near heavy foot traffic areas e g hallways doorways and floors Do not create a trip hazard with the power cord B If your power cord s protective jacket begins to rip or fray exposing the internal wiring shielding etc disconnect it from the power source and discontinue use of the Monster PowerCenter immediately See the Warranty Information section of this owner s manual for important details WARNING Storm Precautions In the event of a lightning storm it s always a good idea to disconnect your Monster PowerCenter there is no need to disconnect your separate components Make sure that ALL of your components and PC products are protected with Monster Power WARNING No User Serviceable Parts Inside If for any reason your PowerCenter is not operating properly do not remove any part of the unit cover etc for repair Unplug the unit and consult the Warranty Information section of this owner s manual for important details
61. r r duire les interf rences entre vos quipements audio A Attachez une tiquette d identification Monster Power au cordon d alimentation de chaque appareil avant de le brancher dans la prise appropri e du PowerCenter identifi e par un code de couleurs B Branchez le cordon d alimentation de chaque appareil r cepteur processeur etc dans la prise correspondante du PowerCenter Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique ou audio de puissance et branchez les dans la prise correspondante pour obtenir le meilleur r sultat NOTE IMPORTANTE Il n y a aucun danger brancher un appareil vid o num rique ou audio de puissance dans une prise audio analogique Cependant pour obtenir le meilleur rendement nous recommandons de ne brancher que des composants audio analogiques dans les prises audio analogiques PHONE LINE SURGE PROTECTION Fn IDE H i ye LN 6 Om 0 See Prises audio analogiques J GUIDE DE RACCORDEMENT Raccordement aux prises audio de puissance Ces prises sont concues pour fournir le maximum de courant aux composants de puissance comme des amplificateurs ou des pr amplificateurs A Attachez une tiquette d identifica
62. rCenter Note 2 The DC Out 1 trigger activates when the PoweCenter is turned on The DC Out 2 trigger activates 5 seconds after the DC Out trigger 1 The DC Out 3 trigger activates 5 seconds after the DC Out trigger 2 REMOTE TURN ON OFF From Control To Control Component Component To Control Component From Control To Control Component Component HOOK UP GUIDE Rack Mounting Your PowerCenter This Monster PowerCenter incorporates mounting plates built into the chassis for installation into a standard size equipment rack Place the PowerCenter into the rack and align the holes with the holes of your rack Insert rack screws not provided and turn clockwise until tight Q O 1 LI LI 2 ifii Mounting s Mounting Holes pane Holes 2 2 9 l 0 el EON C s MC me HOOK UP GUIDE This Monster PowerCenter features attachable removeable rack handles To add the rack handles to this PowerCenter A Remove the decorative plates on the front right and front left sides of the PowerCenter by using a screwdriver placing it on top of the screws and turning it counterclockwise There are two screws total which will also be used to fasten the rack handles to the PowerCenter B Now place a rack
63. rCenter Si vous ne connaissez pas la tension lectrique d livr e dans votre maison veuillez consulter votre compagnie d lectricit locale ou un lectricien qualifi N MISE EN GARDE Mise la terre et polarisation A forcez pas la fiche du PowerCenter dans une prise d alimentation qui n est pas pour accepter le type de prise c a trois fils une prise trois lames Cette fiche est concue pour tre ins r e dans une prise lectrique avec mise la terre uniquement Si cette fiche ne s adapte pas directement votre prise murale n essayez pas de la forcer N essayez jamais de d monter la fiche d aucune facon que ce soit ou de d alt rer le cordon d alimentation N essayez pas de contourner la mise la terre en utilisant un adaptateur de lame 3 2 Si vous avez des questions propos de la mise la terre consultez votre compagnie locale d lectricit ou un lectricien qualifi B Si vous utilisez des dispositifs qui doivent tre install s sur le toit comme un satellite une antenne ou tout autre composant avec un cable branch votre PowerCenter V assurez vous que les c bles sont correctement mis la terre Utilisez les m thodes de mise la terre d crites dans la section 810 du Code national de l lectricit ANSI NFPA 70 au Canada 1 re partie du Code canadien de l lectricit Cela vous prot gera contre les surtensions et les charges lectrostatiques C Ne placez jamais un
64. reils connect s au PowerCenter Assurez vous que TOUS vos produits informatiques et autres appareils sont prot g s par Monster Power MISE EN GARDE Aucune pi ce ne devant tre entretenue par l utilisateur ne se trouve l int rieur du PowerCenter Si pour quelque raison que ce soit votre PowerCenter ne fonctionne pas correctement ne retirez aucune pi ce de l appareil couverde etc pour tenter une r paration D branchez l appareil et consultez la section Informations sur la garantie de ce manuel de l utilisateur pour les d tails importants ATTENTION Exposition la chaleur N exposez pas votre PowerCenter la lumi re directe du soleil et ne le placez pas pr s des calorif res des sources de chaleur ou dans un endroit propice une l vation de la temp rature ATTENTION Nettoyage appropri En g n ral le seul nettoyage n cessaire votre PowerCenter de Monster est un l ger poussetage D branchez cet appareil de la prise murale avant de le nettoyer N utilisez aucun type de nettoyant liquide ou en a rosol MISE LA TERRE ET INSTALLATION AD QUATES N MISE EN GARDE Mise la terre ad quate Le PowerCenter de Monster requiert une sortie ad quatement mise la terre pour la s curit de l utilisateur de que pour la protection de l quipement branch Si vous n tes pas certain que le c blage lectrique de votre foyer est ad quatement mis la terre faites le v rifier p
65. rks of Monster Cable Products Inc and its subsidiaries in the US and other locations MONSTER POWER Professional PowerCenter 5100 TABLE DES MATIERES Page Importantes informations de s curit i Mise la terre et installation ad quates iii Note de la direction de Monster 1 Technologie T2 exclusive de tages brevet s Clean Power de Monster Les cerveaux derri re la conception du PowerCenter de Monster Sp cifications du Monster PowerCenter Signature PRO 5100 Guide de raccordement Prises num riques Prises vid o Prises audio analogiques Prises audio de puissance Programmation des prises R glage de l alarme sonore R glage de l extinction automatique Connexions Connexions t l phoniques Connexions Ethernet Contr le de l alimentation de sortie c c DC Out distance Montage dans une armoire D pannage Sp cifications Annexe Informations sur la garantie 31 IMPORTANTES INFORMATIONS DE S CURIT Veuillez lire et observer les points de s curit suivants en tout temps MISE EN GARDE Sources d alimentation Pour vous assurer d une utilisation s curitaire ne branchez pas ce PowerCenter dans une sortie d alimentation qui diff re de la source indiqu e sur le Powe
66. s du Signature PRO 5100ont t incorpor es la conception avec en t te ces utilisateur et ces environnements Noel Lee Le Signature PRO 5100 comprend le circuit de filtre brevet Monster Clean Power qui bloque pratiquement les fr quences lectromagnetiques et radio qui peuvent d grader la qualit du son et de l image En plus votre PowerCenter comprend aussi des circuits d isolation de bruit qui s pare l audio analogique le vid o le num rique et les sorties audio avec courant tr s haut Le r sultat est une haute qualit de son et d image libre d interf rence qui pourrait endommager la performance Les autres perc es de Monster Power inclut le circuit de protection de d connection reconnection automatique T2 et le syst me de protection Tri Mode comprenant une alarme sonore Ces options d branchent automatiquement l alimentation de vos quipements lectroniques si une surtension importante se produit Nous avons galement inclus des connexions coaxiales t l phoniques et thernet prot g es contre les surtensions pour assurer la protection de tous vos appareils Le Signature PRO 5100 comprend aussi un syst me de code de couleur en attente de brevet qui identifie chacune des composantes doit tre connect e Comme ses coll gues audiophiles et vid ophiles Monster a con u le Signature PRO 5100 pour vous aider obtenir le meilleur son et la meilleure image possible Nous esp rons que vous consid rez ce
67. sound an alarm when the line voltage tops 130V or drops below 100V A Press MENU until the displays shows the alarm setting B Press SELECT to toggle between ENABLE and DISABLE HOOK UP GUIDE Over Voltage and Under Voltage Automatic Shutdown Setting This feature enables or disables the automatic shutdown feature for abnormal line voltage When set to ENABLE the unit will shut itself down whenever the line voltage tops 134V or drops below 96V A Press MENU until the display shows B Press SELECT to toggle between ENABLE and DISABLE HOOK UP GUIDE Coaxial Connections Hook Up Coaxial Connections provide surge protection against damaging voltage surges and spikes on the incoming coax cable Protect TV Cable Satellite and Antenna Connections as Follows TV CABLE N N From properly grounded gt To IV Cable Box TV Cable Line AA 224 SATELLITE From properly grounded 3 gt 10 Satellite Receiver Satellite Dish From properly grounded gt 7 Television Note You will need additional coaxial cables to connect the Signature PRO 5100 to your components HOOK UP GUIDE Phone Connections Hook Up Phone connections provide surge protection against damaging voltage surges and spikes coming from the phone line This PowerCenter also incorporates a 3 way phone splitter for convenience Protect Phone Line Connections as Follows
68. ster will determine whether a Product Defect existed Monster may at its discretion direct You to obtain a repair estimate at a service center If a repair estimate is required You will be instructed on how to properly submit the estimate and the resulting invoice to Monster for payment Any fees for repairs may be negotiated by Monster TIMING If You bring a Formal Warranty Claim and fully comply with all terms and conditions of this Limited Warranty Monster will use its best efforts to provide You with a remedy within thirty 30 days after receipt of Your Formal Warranty Claim if You reside in the United States forty five 45 days if You reside elsewhere unless obstacles outside Monster s control delay the process Ver 121703 US EU 2004 Monster LLC NOTES MONSTER We invite you to visit the Monsters at MonsterPower com Designed in the USA and manufactured for Monster to its quality specifications Made in China 2005 Monster LLC 7251 West Lake Mead Blvd Las Vegas NV 89128 USA 1 877 800 8989 Monster Technology International Ltd Ballymaley Business Park Gort Road Ennis Co Clare Ireland 001 866 348 4171 The Monster Power Professional Reference PowerCenter Signature PRO5100 is protected under U S Pat No 5 589 718 Other Patents Pending Monster Monster Cable Monster Power Clean Power PowerCenter PowerLine T2 and Tri Mode are registered and unregistered tradema
69. t GUIDE DE RACCORDEMENT Raccordement du contr le de l alimentation d entr e c c DC In distance Cette fonction connecte votre PowerCenter un syst me de contr le de cin ma maison automatis ou permet un autre appareil poss dant une connexion de commande de sortie c c DC Out d allumer ou d teindre automatiquement votre PowerCenter A Branchez le cordon d alimentation de l appareil que vous utilisez pour contr ler le PowerCenter dans une prise non commut e d sign e unswitched du PowerCenter Remarque Cet appareil doit d livrer une tension de contr le entre 3 et 30 V c c B Branchez une des prises jack de 1 8 po du cordon fourni dans la connexion DC In correspondante sur le PowerCenter C Branchez l autre prise de 1 8 po dans la connexion de sortie c c DC Out de l appareil que vous d sirez mettre en marche et teindre les prises commut es du PowerCenter une fois allum Raccordement du contr le de l alimentation d entr e c a AC In distance Cette fonction connecte votre PowerCenter un syst me de contr le de cin ma maison automatis ou permet un autre appareil avec une connexion de prise c a par exemple un r cepteur AV ou pr amplificateur pour automatiquement mettre en marche et teindre votre PowerCenter A Ins rez la prise femelle du cordon de contr le d entr e c a AC IN dans la connexion de 120 V AC IN du PowerSource B Ins rez la prise m le deux broches d
70. t appareil comme partie int grante de votre syst me audio vid o et de votre cin ma maison Noel Lee Direction de Monster TECHNOLOGIE T2 EXCLUSIVE A MONSTER Le Monster Power Signature PRO 5100 PowerCenter comprend la technologie T2 exclusive Monster Le T2 est un circuit lectronique actif contr l par microprocesseur log l avant du circuit de protection contre les surtensions dans tous les produits Monster Power Le T2 surveille le conducteur le neutre et le conducteurs de mise la masse et d connecte automatiquement le PowerCenter du conducteur d alimentation c a lorsque se produit une variation prolong e de voltage vers le haut ou vers le bas tension continue en dessous de 80Vrms ou au dessus de 132 Vrms Lorsque l alimentation atteint l un de ces niveaux potentiellement dangereux le circuit de protection ultra rapide T2 teint le PowerCenter de Monster pendant 15 secondes Lorsque les conditions d alimentation reviennent la normale la technologie T2 r active le PowerCenter apr s 15 secondes Dans le cas contraire le probl me persiste le circuit comparateur de la technologie T2 laisse l appareil teint Contrairement aux appareils de protection d alimentation classiques la technologie T2 teint votre PowerCenter avant que les varistors oxyde m tallique et fusibles thermiques ne d tectent les conditions de surtension et prot gent vos quipements en br lant Cette caract ristique tendra la dur
71. t limitation acts of God fire storms excluding lightning surges earthquake or flood Warranty Period means the time period during which Monster must have received Your Formal Warranty Claim The different Warranty Periods related to Product Defects and Connected Equipment Damage are defined in the Specifications Table below The Warranty Period commences on the date when You purchased or received whichever occurs later the Product from an Authorized Dealer as evidenced by the Authorized Dealer s invoice sales receipt or packing slip If You do not have written proof of the date of purchase or receipt then the Warranty Period commences three 3 months after the date when the Product left Monster s or its factory as evidenced by Monster s records The Warranty Period ends after the time defined in the Specifications Table has expired or after You have transferred ownership of the Product whichever occurs earlier Also You must call Monster and obtain a Return Authorization Number as described under How to Make a Claim within two 2 months after You discover a Product Defect or should have discovered it if such Product Defect was obvious You means the first individual person that purchased the Product in its original packaging from an Authorized Dealer This Limited Warranty does not apply to persons or entities that bought the Product i in used or unpackaged form ii for resale lease or other commercial use or iii from someon
72. tion Monster Power au cordon d alimentation de chaque appareil avant de le brancher dans la prise appropri e du PowerCenter identifi e par un code de couleurs B Branchez le cordon d alimentation de chaque appareil amplificateur etc dans la prise correspondante du PowerCenter Pour les appareils non indiqu s sur la liste voyez s ils correspondent au type audio vid o num rique ou audio de puissance et branchez les dans la prise correspondante pour obtenir le meilleur r sultat NOTE IMPORTANTE Il n y a aucun danger brancher un appareil audio analogique vid o ou num rique dans une prise audio de puissance Cependant pour obtenir le meilleur rendement nous recommandons de ne brancher que des composants audio analogiques de puissance dans les prises audio analogiques de puissance 80909 Oo ii Ow Ow Ow a Ow 7 0 0 000 emis Prises audio de puissance GUIDE DE RACCORDEMENT Programmation de sortie Toutes les prises du panneau arri re du PowerCenter sont programmables par les boutons de menu et de s lection du panneau avant Pour r gler chaque paire de prise utilisez les boutons MENU et SELECT du panneau avant pour choisir entre les modes de commutation SWITCHED ON commutation avec retard d allumage SWITCHED ON
73. u are using the Remote Turn On feature Same as Switched and haven t plugged the plug into the component you wish to use to activate the Remote Turn On Remedy Plug the plug into component you wish to use to activate the Remote Turn On The component remote control you are using to power the Remote turn on has a dead battery Replace the battery powering the component remote control The component you wish to use to activate the Remote Turn On isn t plugged into a properly grounded 120 volt nominal outlet Plug the component into a properly grounded 120 volt nominal outlet Video picture has rolling bars or ghosting The incoming video signal is not properly grounded Contact your cable or satellite provider to correct your installation The PowerCenter is emitting a loud buzzing alarm The PowerCenter protection circuitry has sacrificed itself to protect connected equipment from a catastrophic surge The PowerCenter must be replaced See the Warranty Information section for important details SPECIFICATIONS SIGNATURE PRO 5100 POWERCENTER Continuous Duty Electrical Rating 120V 60Hz Maximum Current Rating 20A 2400W Line Neutral L N Protection Modes Line Ground L G Neutral Ground N G Total Energy Dissipation 6814 Joules Clamping Level TVSS Voltage 330 Volts Clamping Response Time Less than 1 Nanosecond lt 1Ns Remote DC In Contr
74. u cordon de contr le d entr e c a AC IN dans une prise de sortie c a commut e de l appareil qui doit contr ler le PowerCenter par exemple un r cepteur audio vid o ou un pr amplificateur Lorsque votre appareil est allum les prises commut es Switched On programm es du PowerCenter s allument imm diatement Les prises Switched On After Delay programm es s allument apr s le d lai imparti Raccordement du contr le de l alimentation de sortie c c DC Out distance Cette fonction connecte votre PowerCenter un syst me de contr le de cin ma maison automatis ou permet au PowerCenter d allumer ou d teindre automatiquement un autre appareil poss dant une connexion de commande d entr e c c DC In Branchez une des prises Jack de 1 8 po du cordon dans la connexion de sortie c c DC Out correspondante du PowerCenter B Branchez l autre prise de 1 8 po dans la connexion d entr e c c DC In de l appareil qui doit tre contr l par le PowerCenter Remarque Il se peut que cet appareil ne comporte pas d tiquette DC In Cet appareil doit accepter une tension de contr le entre 3 et 30 V c c Remarque 1 Un cordon avec prise Jack de 1 8 po est fourni avec le PowerCenter Remarque 2 Le d clencheur DC Out 1 s active lorsque le PowerCenter est mis en marche Le d clencheur DC Out 2 s active 5 secondes apr s le d clencheur DC Out 1 Le d clencheur DC Out 3 s active 5 secondes apr s le d clen

Download Pdf Manuals