Emerson GXT3-144BATKIT
Contents
1. AC Power For Business Critical Continuity Liebert GXT3 5kVA 10kVA UPS Compact UPS Systems For High Power Network Rack Applications 4 nd EMERSON Network Power Today s converged networks require increased availability and reliability This has created a need for higher density power protection systems that adapt to mixed load voltages and plug types while remaining easy to install and maintain New IT technologies such as VoIP and PoE have greatly increased power demands Unfortunately as these requirements have risen the amount of space available for your protected equipment and related power support systems has not Liebert GXT3 UPS meets the need for higher power capacities in small spaces This true on line double conversion UPS system is available in 5kVA 10kVA models and features integrated maintenance bypass as well as optional extended battery runtime Add support Emerson Network Power Service and it all equals greater power assurance and reliability Designed for use in either rack or tower configurations all units offer the smallest available solutions for these power capacities the 5 amp 6kVA model at 120 208V output in 4U size or the 8 amp 10kVA unit 120 208V output in a 6U package A 6kVA 208V output 5U size model is also available To help meet the need for choosing a single supplier for global applications 220V 230V and 240V 50 60 Hz
2. models are offered with CE and C tick markings Simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 VAC provide the flexibility to adapt to multiple load requirements without the need to add additional transformers that take up extra space and add weight Input power factor correction to 0 99 reduces current harmonics and their heating effects Liebert GXT3 UPS offers a variety of communications options to provide the monitoring and control capabilities demanded by today s network computing systems Operation can be monitored using Liebert IntelliSlot Web Card provides SNMP and web based monitoring and control of your UPS Liebert MultiLink Automated System Shutdown Software Liebert Nform Monitoring System Liebert Universal Monitor And Remote Power Monitor Panels Third Party Monitoring Systems Surge Utility suppression Correction Rectifier tteall mir SEL me Liebert IntelliSlot Webcard provides SNMP and web based management Dynamic ypass Power Factor Inverter Output Charger Battery Flexibility Rack tower configuration The versatile unit installs in either configuration and includes a rotating LED display panel that conforms to the desired orientation Automatic frequency detection Detects and matches line input frequencies of either 60 or 50 Hz User replaceable hot swappable internal batteries Provide
3. 20VAC nominal 100 110 115 120 127VAC 2 1 Minute 10 seconds 1 second At least 5 cycles 32 to 104 0 to 40 5 to 122 15 to 50 Less than 55dBA at 3 2ft 1m rear less than 50dBA at 3 2ft 1m front and sides Up to 10 000 ft 3000m at 104 F 40 C without derating 0 to 95 non condensing UL 1778 cUL Listed FCC Part 15 Subpart B Class A FCC Class A IEEE ANSI C62 41 Category A amp B ISTA Procedure 1A YES GXT3 288RTBKIT GXT3 8000RT208 GXT3 10000RT208 8 1x19 7x5 3 207 x 500x 135 GXT3 144BATKIT GXT3 5000RT208 GXT3 6000RT208 8 1x 19 3 x 2 8 206 x 490 x 70 75 8 34 4 Ti EOS Valve regulated non spillable lead acid 2x6x12V x9 0 AH 2x12x 12V x 9 0 AH 6 hours to 90 capacity after full discharge into 100 load Operating Temp Storage Temp Operating Elevation and Relative Humidity Same as UPS External battery cabinet specifications Model Number GXT3 144VBATT GXT3 240VBATTUL GXT3 288RTVBATT Used w UPS Model GXT3 5000 amp GXT3 6000RT208 GXT3 6000RTL630 GXT3 8000 amp GXT3 10000RT208 Dimensions W x D x H 16 9 x 26 1 x 3 3 16 9 x 22 6 x5 1 16 9 x 26 5 x 6 8 Unit with bezel in mm 430 x 662 x 85 430 x 574x 130 430 x 672 x 173 Weight Unit Ib kg 99 9 45 3 94 8 43 29 8 13 5 Battery Parameters Type Valve regulated non spillable lead acid Kit Quantity x Battery Quantity x Rating 2x6x12Vx9 0 AH 2x10x 12V x9 0 AH 2x12x 12V x 9 0 AH Environmental Operating Temp Storage Te
4. NE on E S 4 L6 20R Connection 8 5 20R 4 5 20R 4 L6 30R 2 L6 20R 2 L5 20R 4 L5 20R Battery run time minutes Run Time Minutes Load GXT3 5000RT208 GXT3 6000RT208 GXT3 6000RTL630 GXT3 8000RT208 GXT3 10000RT208 10 105 100 gt 90 150 90 20 50 41 60 57 42 30 30 23 40 34 26 40 22 17 27 25 18 Internal 50 16 12 21 18 13 5 Battery 60 12 10 16 14 11 70 10 7 13 12 8 80 8 5 5 11 9 7 90 6 4 5 9 8 6 10076 5 4 8 7 4 5 Emerson Network Power a business of Emerson NYSE EMR delivers software hardware and Emerson Network Power 9 eene i Liebert Corporation World Headquarters services that maximize availability capacity and efficiency for data centers healthcare and 1050 Dearborn Drive EM P O Box 291 industrial facilities A trusted industry leader in smart infrastructure technologies Emerson Em E uu olumbus Ohio 43229 Network Power provides innovative data center infrastructure management solutions that United States Of America B e 800 877 9222 Phone U S amp Canada Only bridge the gap between IT and facility management and deliver efficiency and uncompromised 614 888 0246 Phone Outside U S 614 841 6022 FAX Contact EmersonNetworkPower com availability regardless of capacity demands Our solutions are supported globally by local Emerson Network Power service technicians Learn more about Emerson Network Power Emerson Network Power Caribbean and Latin America products and services at www Eme
5. acks are hot swappable and user repleaceable The unit also supports up to four external battery cabinets for extended run time This Liebert GXT3 8 amp 10kVA units offer a flexible solution for protecting rack mount equipment including VoIP and PoE Especially designed for use with the new generation of high power switches these compact UPS systems pack 8kVA 7 2kW or 10kVA 9kW of power into a 6U rack tower package with flexible output voltage and optional output distribution The UPS includes built in user replaceable batteries for up to four minutes of runtime at full load Adaptable Design The UPS has a dual inverter design capable of providing simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 and an output power factor of 0 9 The new 6U cabinet is the smallest for 208 120 selectable voltage in the 8 10kVA size The unit features integrated internal manual and automatic maintenance bypass power module battery modules auto detection of extended battery cabinets and optional plug and play distribution plates The standard 8 amp 10kVA models include terminal blocks for hardwired connections of both input and output Optional power distribution modules are available to add output receptacles to the rear panel of the unit Hot Swappable Operation Liebert GXT3 8 amp 10kVA units feature three bays for one power module and two battery modules The chassis contains a by
6. four minutes of runtime at full load Additional runtime with additional battery cabinets UPS cabinet includes rear panel plug and play connections for optional battery cabinets Cabinet sizes 5 6kVA 2U 8 10kVA 4U 6kVA 208V 3U Liebert IntelliSlot communications port Utilizes Liebert IntelliSlot Web Card to provide SNMP and web based monitoring and control of your UPS Includes Windows based configuration program Allows various operating parameters to be adjusted and tests to be scheduled Built in USB communications for use with Liebert MultiLink Automated Shutdown Software Allows you to monitor communication between the UPS and a server and ensures a graceful unattended shutdown Built in closure signals Provides notification to monitoring systems of operating conditions including on battery low battery battery mode shutdown and any mode shutdown Emergency Power Off EPO Terminal connections for a normally open or normally closed emergency power off switch Higher Availability Wider input voltage window minimizes battery use Features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery extending system availability for when battery back up is truly needed Internal automatic and manual bypass Assures continuity of power to critical loads during system maintenance or in case of internal fault Self diagnostics Automatical
7. ly tests unit electronics and batteries Designed to simplify maintenance and troubleshooting Lowest Total Cost Of Ownership Standard two year replacement warranty No hassle warranty provides paid shipping both ways Optional one year and three year extensions available Uses less rack space Leaves more room for network equipment For longer service life Shields batteries from heat generating electronic components enhancing battery life Battery cutoff voltage Automatically adjusts based on load extending battery life by preventing over discharge of batteries ENERGY STAR qualified UPS models UPS products meeting the EPA s requirements use an average of 35 less energy than their standard counterparts UPS operation and display panel can rotate 90 degrees which provides upright viewing for users 5 Or 6kVA Of True On Line Power In A Compact 4U Package Liebert GXT3 5 amp 6kVA models are true on line UPS systems that provide internal batteries and dual output voltage They are an ideal fit for applications where the power requirements are demanding but rack space is limited delivering 5kVA 4kW or 6kVA 4 8kW of power in a single 4U size cabinet This cabinet size is well suited for installations such as network closets or small data centers Adaptable Design For installation flexibility the Liebert GXT3 5 amp 6kVA models allow you to choose from several different wiring co
8. mp Operating Elevation and Relative Humidity Same as UPS Power distribution box specifications GXT3 5000RT208 GXT3 6000RT208 and GXT3 6000RTL630 Power Distribution Box Model iba PD2 HDWR PD2 HDWR MBS PD2 001 PD2 002 PD2 003 PD2 004 PD2 005 PD2 006 PD2 L630 Dimensions WxDxH 5 2x15 5x3 5 5 2Xx15 5x3 5 5 2x15 5x3 5 5 2x15 5x3 5 4 7x13 2x4 1 Unit in mm 132x393x88 132x393x88 132x393x88 132x393x88 119x335x105 Weight Ib kg 5103 6Q27 88 4 8 6 39 8 6 3 9 99 45 10 6 48 9 5 43 8 8 4 Electrical Specifications Amp Rating 30A 2 pole input breaker for UPS input power Input Power Hardwire Terminal Block Connections 3W G I L N G 1 L14 30P on a 3 2m cord 1 L6 30P l 4 5 20R Output Power Hardwire Terminal Block 1 L14 30 2 5 20R 4 5 20R 4 L5 20R 4 L5 20R 4 L6 20R 2 L6 20R Connection 3W G L L N G 1 L6 30R 2 L6 20R 2 L6 30 2 L5 30R 2 L6 30R 2 L6 30R Power distribution box specifications for GXT3 8000RT208 and GXT3 10000RT208 Power Distribution Box Model Number PD2 101 PD2 102 PD2 103 PD2 104 PD2 105 PD2 106 Ed eH 7 4x5 7 188x145 7 4x5 7 188x145 7 4x5 7 188x 145 7 4x5 7 188x 145 7 4x5 7 188x145 7 4x5 7 188x 145 Weight Unit Ib kg 4 4 2 6 6 3 6 6 3 6 6 3 4 4 2 6 6 3 Electrical Specifications Amp Rating 2 pole 60A Input Breaker EUM Hardwire Terminal Block 3W G L L N G to Chassis Output Power 2 L6 30 4 L6 20R 4 5 20R
9. nfigurations made possible by the use of removable power distribution boxes that simply plug into the rear of the UPS The standard box provides terminal blocks for hardwired input and output connections An optional hardwire version that includes a maintenance bypass is also available When the ease of plug and play power connections is desired optional versions of the power distribution box convert Liebert GXT3 5 amp 6kVA units to a cord type input with receptacles for output distribution and also offers maintenance bypass capability that allows hot swapping of the entire UPS The UPS has as adaptable dual inverter design capable of providing simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 and an output power factor of 0 8 PD2 HDWR ships standard with the unit and is hardwire input output PD2 HDWR MBS is an optional hardwire input output POD with maintenance bypass Pluggable input output PODs available with maintenance bypass 5 amp 6 kVA Model shown in rack mount position 6 kVA Model shown in tower position with optional battery cabinet 8kVA And 10kVA Of Power In Just 6U Of Space 28 amp 10 kVA Model shown in rack mount position 10 k VA Model shown in tower position with optional battery cabinet UPS is hardwire input output with maintenance bypass and includes no POD standard Optional PODs available The internal battery p
10. pass switch that allows all modules to be removed without powering down the connected load Product specifications UPS specifications 5 6 8 and 10 kVA models Model Number Model Rating Dimensions Rack Mount W x D x H Unit in mm Weight Unit Ib kg Input AC Parameters Nominal Operating Frequency Factory Default VAC Factory Default L1 N L2 N VAC Input Frequency w o Battery Operation Input Power Connection L1 N L2 N Maximum Allowable VAC Output AC Parameters Factory Default VAC Factory Default L1 N L2 N VAC User Configurable L1 N L2 N VAC Overload Rating 105 to 130 131 to 150 151 to 200 gt 200 impact load Environmental Operating Temp F C Storage Temp F C Audible Noise Operating Elevation Relative Humidity Agency Safety RFI EMI Surge Immunity Transportation ENERGY STAR qualified Internal battery specifications Model Number Used with UPS Model Dimensions W x D x H Unit in mm Weight Unit Ib kg Battery Parameters Type Kit Quantity x Battery Quantity x V x Rating Recharge Time Environmental GXT3 5000RT208 4000W 5000VA GXT3 8000RT208 GXT3 10000RT208 7200W 8000VA 9000W 10000VA 16 9 x 26 5 x 10 3 430 x 672 x 261 GXT3 6000RT208 4800W 6000VA 16 9 x 26 1 x 6 8 430x662 x 173 56 2 25 5 78 3 35 5 50 or 60Hz Factory Default is 60Hz 120 208VAC 120 VAC nominal 40 70Hz Hardwire Terminal Block 3W G L L N G 150VAC 120 208V AC 1
11. rsonNetworkPower com ie ide cise as aie 1 954 984 3452 Phone Ask Cala Emerson com liebert com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 outside U S Emerson Network Power The global leader in enabling Business Critical Continuity While every precaution has been taken to ensure accuracy and completeness in this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2013 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice All names referred to are trademarks or registered trademarks of their respective owners Liebert is a registered trademark of the Liebert Corporation SL 23184 RO7 13 Printed in USA Emerson Network Power EmersonNetworkPower com The global leader in enabling Business Critical Continuity AC Power Embedded Computing Outside Plant Racks amp Integrated Cabinets Connectivity Embedded Power Power Switching amp Controls Services DC Power EI Monitoring Precision Cooling E Surge Protection Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2013 Emerson Electric Co
Download Pdf Manuals
Related Search
Related Contents
Pass Laboratories Aleph 3 Service Manual rev 0 2/1/96 Samsung SM-S975LZKATFN Quick Start Guide LC200 LED Lighting Controller User Manual 1 Perf Protech: Shift Cable Installation King Canada 8498 User's Manual Section “Installing packages” in R Installation and Administration 2. - Eizo HUMAN IgG SUBCLASS LIQUID REAGENT KITS (for use on the Kuschall Advance Service Manual 0515 Copyright © All rights reserved.