Home

Funkwerk Bintec W1002n

image

Contents

1. message Displayed IPSec tunnels and IPSec statistics output via web based configuration interface http https Statistic information of all physical and logical interfaces ETHO ETH1 SSIDx Detailed displays for radio VSS WDS link bridge links client links Displayed are per link MAC address IP address TX packets RX packets signal strength for every receiving aerial signal to noise ratio data rate Following events can be scheduled Reboot device activate deactivate interface activate deactivate WLAN initiate 5 GHz band scan trigger SW update trigger configuration backup WiLMA DIME manager XAdmin Protocols Madge Discovery Protocol MDP Funkwerk discovery protocol ADP works also across subnets Documentation German and English documentation on CD and in the Internet for download Guarantee 2 year manufacturer s guarantee Online RMA handling Funkwerk Enterprise Communications GmbH Suedwestpark 94 90449 Nuremberg Germany bintec W1002n Phone 49 0 911 9673 0 Fax 49 0 911 688 0725 07 09 2010 Subject to technical E Mail info funkwerk ec com www funkwerk ec com alterations Software Features Feature Roaming access point mode Fast roaming 802 1x access point Roaming behaviour client mode WDS Bridge point to point point to multipoint Bridge Bridge link test Bridge link encryption Client mode Buffer pool WMM 802 11e QoS WMM Power Save U APSD Internet dialup L
2. 0725 Subject to technical E Mail info funkwerk ec com www funkwerk ec com alterations Operating Modes Feature WLAN disabled WLAN access point WLAN bridge WLAN client Security Feature Encryption WEP WPA IEEE802 11i authentication and encryption Access control list ACL VLAN Inter cell repeating NAT PAT VPN IPSec VPN IPSec VPN IPSec DPD VPN PPTP VPN PPTP DynDNS DynVPN IKE for IPSec X 509 QoS for IPSec PKI Support for IPSec NAT Traversal for IPSec IPCOMP IPSec RADIUS IPSec redesign L2TP GRE Hardware encryption Funkwerk Enterprise Communications GmbH Suedwestpark 94 90449 Nuremberg Germany Phone 49 0 911 9673 0 Fax 49 0 911 688 0725 E Mail info funkwerk ec com www funkwerk ec com funkwerk enterprise communications Description In this operation mode the device is a powerful 2 port VPN router WLAN access point with VPN router functionalities Point to point and point to multipoint mode up to 8 links Transparent client for direct connection of Ethernet devices Description WEP 64 40 Bit key WEP128 104 Bit key WPA personal WPA enterprise WPA2 personal WPA2 enterprise 802 1x EAP MD5 802 1x EAP TLS 802 1x EAP TTLS 802 1x EAP PEAP key management PSK TKIP encryption AES encryption 802 1x EAP MAC address filter for WLAN clients Network segments on layer2 possible Per SSID one VLAN ID available Static VLAN configuration according
3. IEEE 802 1q up to 32 VLANs supported Inter traffic blocking for public hot spot PHS applications for preventing of communication radio client to radio client in a single radio cell Network amp Port Address Translation Stateful Packet Inspection Isolation of complete network from public access 10 tunnels inclusive 100 more via separate license Powerful encryption up to 256 bits AES 3DES DES CAST Blowfish Twofish Dead Peer Detection for IPSec tunnels Integrated Strong encryption up to 128 bits MPPE up to 168 bits DES 3DES Blowfish Router can still be reached over the Internet in spite of dyn IP address Pre Shared Keys and X 509 certificate support X 509 v1 v3 certificates PKCS 7 8 10 12 CLRs SCEP Available Available Available IP compression Available Policy manager and interface concept Layer 2 tunnelling protocol for ATM Ethernet PPP user authentication V 0 according RFC 2784 for common encapsulation 3DES AES and RC4 bintec W1002n 07 09 2010 Subject to technical alterations Wireless LAN Features Feature WLAN standards Frequency bands 2 4 GHz indoor outdoor EU Frequency bands 5 GHz indoor EU Frequency bands 5 GHz outdoor EU Frequency bands 5 8 GHz BFWA Germany WLAN modes Automatic Rate Selection ARS Transmission rate Data rates for 802 11b g 2 4 GHz Data rates for 802 11a h 5 GHz Data rates for 802 11n 2 4 5 GHz Receiver Sensitivity 2 4 G
4. 0 g Less than 10 Watt Temperature operating 0 C to 40 C storage 10 C to 70 C rel humidity 10 to 95 non condensing bintec W1002n 07 09 2010 Subject to technical alterations
5. Bm 48 Mbps 74 dBm 54 Mbps 73 dBm MSCO 88 dBm MSC1 85 dBm MCS2 83 dBm MCS3 81 dBm MCS4 78 dBm MSC5 74 dBm MCS6 72 dBm MCS7 70 dBm MCS8 88 dBm MCS9 85 dBm MCS10 83 dBm MCS11 80 dBm MCS12 77 dBm MCS13 72 dBm MCS14 70 dBm MCS15 68 dBm MSCO 84 dBm MSC1 82 dBm MCS2 79 dBm MCS3 77 dBm MCS4 74 dBm MSC5 69 dBm MCS6 67 dBm MCS7 66 dBm MCS8 83 dBm MCS9 82 dBm MCS10 79 dBm MCS11 76 dBm MCS12 72 dBm MCS13 68 dBm MCS14 66 dBm MCS15 64 dBm Adjustable in following steps 5 8 11 14 16 und 17 5 dBm Maximal power varies depending on data rate and frequency band 1 Mbps 16 dBm 2 Mbps 16 dBm 5 5 Mbps 16 dBm 11 Mbps 16 dBm 6 Mbps 17 5 dBm 9 Mbps 17 5 dBm 12 Mbps 17 dBm 18 Mbps 17 dBm 24 Mbps 15 dBm 36 Mbps 15 dBm 48 Mbps 13 dBm 54 Mbps 13 dBm MSCO 17 5 dBm MSC1 17 5 dBm MCS2 17 dBm MCS3 17 dBm MCS4 15 dBm MSC5 15 dBm MCS6 13 dBm MCS7 13 dBm MCS8 17 5 dBm MCS9 17 5 dBm MCS10 17 dBm MCS11 17 dBm MCS12 15 dBm MCS13 15 dBm MCS14 13 dBm MCS15 13 dBm 1 Mbps 16 dBm 2 Mbps 16 dBm 5 5 Mbps 16 dBm 11 Mbps 16 dBm 6 Mbps 17 5 dBm 9 Mbps 17 5 dBm 12 Mbps 17 dBm 18 Mbps 17 dBm 24 Mbps 15 dBm 36 Mbps 15 dBm 48 Mbps 13 dBm 54 Mbps 13 dBm MSCO 17 5 dBm MSC1 17 5 dBm MCS2 17 dBm MCS3 17 dBm MCS4 15 dBm MSC5 15 dBm MCS6 13 dBm MCS7 13 dBm MCS8 17 5 dBm MCS9 17 5 dBm MCS10 17 dBm MCS11 17 dBm MCS12 15 dBm MCS13 15 dBm MCS14 13 dBm MCS15 13 dBm 1or2 20 40 MHz bundling
6. Hz 802 1 1b g Receiver Sensitivity 2 4 GHz 802 11n 20 MHz Receiver Sensitivity 2 4 GHz 802 11n 40 MHz Receiver Sensitivity 5 GHz 802 11a h Receiver Sensitivity 5 GHz 802 11n 20 MHz Receiver Sensitivity 2 4 GHz 802 11n 40 MHz Output power without antenna gain Tx Power 2 4 GHz 802 1 1b g Tx Power 2 4 GHz 802 11n 20 MHz 40 MHz Tx Power 5 GHz 802 11b g Tx Power 5 GHz 802 11n 20 MHz 40 MHz Number of spatial streams 802 1 1n Bandwidth 802 1 1n Short guard interval 802 11n DTIM Period Multi SSID Broadcast SSID Clients Pwr Managmt max number funkwerk enterprise communications Description 802 11n Mimo 2x3 802 11b 802 119 802 11a 802 11h 2 4 GHz Indoor Outdoor 2412 2472 MHz max 100 mW EIRP This information is related to the permitted transmission power in Germany The permitted transmission power may vary in other countries 5 GHz indoor 5150 5350 MHz max 200 mW EIRP allowed This information is related to the permitted transmission power in Germany The permitted transmission power may vary in other countries 5 GHz outdoor 5470 5725 MHz max 1000 mW EIRP allowed This information is related to the permitted transmission power in Germany The permitted transmission power may vary in other countries 5 8 GHz BFWA 5755 5875 MHz max 4000 mW EIRP allowed This information is related to the permitted transmission power in Germany For the usage in other coun
7. On the Configuration a maintenance Software update External reporting Syslog External reporting eMail alert External reporting SNMP traps External reporting Activity monitor Monitoring Internal Log Monitoring IPSec Monitoring Interfaces Monitoring WLAN Monitoring Configurable scheduler Management Supported Management Discovery function funkwerk enterprise communications Description Telnet SSH HTTP HTTPS SNMP SNMP v1 v2 v3 USM model VACM views SNMP traps v1 v2 v3 configurable SNMP IP access list configurable Complete management with MIB II MIB 802 11 enterprise MIB Supports SSH V1 5 and SSH V2 0 for secure connections of terminal applications Web based configuration FCI The user interface is identical with almost all Funkwerk products SSH available HTTPS Telnet protected against bruce force attacks Load and save of configurations save configuration optionally encrypted optional automatic controlled via scheduler No restart is required after the configuration has been changed Software updates free of charge loadable via file HTTP or via direct access to the FEC server optional automatic controlled via scheduler Syslog client with different levels of messaging Automatic eMail alert by definable events Supported Sending of information to a PC on which Brickware is installed Output via web based configuration interface http https filter subsystem level
8. funkwerk enterprise communications WLAN ACCESS POINT e WLAN according IEEE 802 11n compatible wit Dual band radio with 2 4 GHz 5 GHz and 5 8 GE Brutto transmission rates up to 300 Mbps Operation as access point bridge WDS client PoE Power over Ethernet Certificated for operation in medical environm CERTIFIED dual stream n funkwerk bintec W1 002n enterprise communications o WLAN according to IEEE 802 11n o Dual band radio module with 2 4 GHz and 5 GHz o Physical data rates of up to 300 Mbps o Compatible with IEEE 802 11agbh devices o Operation as access point bridge WDS client o Integrated VPN router providing up to 110 tunnels simultaneously o Distinct increase of data rates for LAN to LAN coupling compared with conventional WLAN bridges o PoE Power over Ethernet according to IEEE 802 3af With the IEEE 802 11n compatibility mode the W1002n offers compatibility with all previous IEEE 802 119 or IEEE 802 11abgh clients and supports the mixed operation of clients according to IEEE 802 11n and clients according to IEEE 802 11b g or IEEE 802 11a h This permits the trouble free replacement of existing access points by the new W1002n without the necessity of exchanging the previous clients Clients already supporting 802 11n will automatically benefit from the higher throughput and the better coverage of areas The operation of two W1002n devices in the bridge mode permits the setup of line of sight rad
9. h high security TKIP and AES possible Routing or bridge mode possible In bridge mode multiple IP based end devices can be operated simultaneously and additionally one non IP based end device For cushioning of peaks Data prioritization for TOS data 802 11e WMM Support of active WLAN clients which support 802 11e power save PPPoE PPTP Session round robin load dependent bandwidth Broken Link Detection BLD per SSID possible NTP client NTP server manually DNS client DNS server DNS relay DHCP client DHCP server DHPC relay Description Wi Fi Certified according 802 1 1abgn Rel 7 9 4 R amp TTE Directive 1999 5 EG EN 60950 1 IEC60950 EN 300 328 EN 301 489 17 EN 301 489 1 EN 301 893 EN 60601 1 2 medical electrical devices Part 1 2 2 x 10 100 Mbps Ethernet twisted pair autosensing auto MDI MDI X V 24 interface with D Sub9 jack for configuration IEEE 802 11a b g n 1 radio module 2 4 und 5 GHz band 3 external antennas Three antenna connectors with RTNC jacks delivered incl three 2 5 dBi omni directional antennas Even at power loss the system time will be available for several hours External wall power supply 230V 12 V DC 1 A with high efficient switching power supply Power over Ethernet according IEEE 802 3af Status activity for WLAN Ethernet 1 Ethernet 2 Theft protection optional available Integrated in the housing design Approx 16 3 cm x 16 8 cm x 5 cm width x depth x hight Approx 40
10. io links Here again the benefits of the IEEE 802 11n technology can be used by transferring two separate data streams The application of dual polarization antennas permits easy installation Dual polarization antennas consist of two antenna segments which are polarized orthogonally to each other They therefore provide 2 cable connections This means that the W1002n transmits two separated partial streams from a to b as defined by IEEE 802 11n With this technology more than triple the data rates can be reached compared to the previous technology At a distance of 1000 m net data rates of approximately 75 Mbps TCP IP can be attained by using our dual polarization antennas The power supply is either performed by means of a highly efficient 230 V plug in power supply or via PoE Power over Ethernet according to Standard IEEE 802 3af In the case of operation via PoE it suffices to use a default PoE injector or for instance a Funkwerk S128p switch with integrated PoE feeding Expensive special PoE injectors are not required for the W1002n For the application on the medical sector the W1002n has been granted admission according to EN60601 1 2 like its predecessor W1002 You can download the corresponding certificate in the download section WLAN Products Conformity Declarations Funkwerk Enterprise Communications GmbH Suedwestpark 94 90449 Nuremberg Germany bintec W1002n Phone 49 0 911 9673 0 07 09 2010 Fax 49 0 911 688
11. oad balancing BLD NTP DNS DHCP Hardware Features Feature Certifications Standards and certifications LAN WAN Serial interface WLAN Antenna Real time clock Power supply PoE Status LEDs Theft protection Wall mounting Dimensions Weight Power consumption Environment Funkwerk Enterprise Communications GmbH Suedwestpark 94 90449 Nuremberg Germany Phone 49 0 911 9673 0 Fax 49 0 911 688 0725 E Mail info funkwerk ec com www funkwerk ec com funkwerk enterprise communications Description Seamless roaming with IAPP artem Inter Access Point Protocol Pre authentication and PMK caching allows fast roaming by 802 1x encryption Adjustable no slow normal fast customized roaming Adaptable for fast movable client i e vehicle to guarantee a roaming without interruption This is achieved by scanning of the relevant channels in the background Wireless Distribution System Include high security TKIP and AES interoperable with other devices from the Funkwerk EC portfolio not bintec W500 Point to point connection between two access points point to multipoint connection between up to eight partners access points Full remote configuration Protocol with encrypted transmission RTS CTS threshold adjustable Operating channels According to the regulatory domain Transmit speed Auto fallback or selectable fixed rate Via the link test the quality of a bridge link can be measured Wit
12. of two adjoining 20 MHz channels to one 40 MHz channel On off switchable increase of throughput by reduction of the guard intervals from 800ns to 400ns Adjustable Depending on the complexity of configuration up to 8 service sets per radio module with virtual access points and own MAC address per SSID On off switchable Registering of up to 250 clients per radio module simultaneously in access point mode Default value is 32 clients Country specific settings Channel settings according regulatory domain 802 11d permitted TPC TPC transmission power control For 5 GHz automatic reduction of transmission power according EN301893 DFS DFS dynamic frequency selection For 2 4 and 5 GHz channels are dynamically used depending on operating grade DFS is implemented in bridge links master and slave RTS CTS RTS CTS threshold adjustable Funkwerk Enterprise Communications GmbH Suedwestpark 94 90449 Nuremberg Germany bintec W1002n Phone 49 0 911 9673 0 07 09 2010 Fax 49 0 911 688 0725 Subject to technical E Mail info funkwerk ec com www funkwerk ec com alterations Maintenance and Service Feature Configuration a maintenance Device Configuration a maintenance SNMP Configuration a maintenance SNMP Configuration a maintenance SSH Configuration a maintenance HTTP HTTPS Configuration a maintenance Secure Configuration a maintenance Configuration export and import Configuration a maintenance
13. tries please contact the location regulation authorities 2 4 GHz operation 802 11b only 802 11g only 802 11b g n mixed 802 11b g n mixed long 802 11b g b mixed short 802 1 1b g n 802 11g n 802 11n only 5 GHz Operation 802 11a only 802 11a n 802 11n only Available Automatic fallback or fixed transmission rate selectable 11 5 5 2 und 1 Mbps DSSS modulation 54 48 36 24 18 12 9 and 6 Mbps OFDM modulation 54 48 36 24 18 12 9 and 6 Mbps OFDM modulation MSCO0 15 enables physical rates up to 150 Mbps at 20 MHz channels bandwidth 2 streams short guard interval MSCO 15 enables physical data rates up to 300 Mbps at 40 MHz channels bandwidth 2 streams short guard interval 1 Mbps 91 dBm 2 Mbps 90 dBm 5 5 Mbps 89 dBm 11 Mbps 88 dBm 6 Mbps 90 dBm 9 Mbps 89 dBm 12 Mbps 88 dBm 18 Mbps 86 dBm 24 Mbps 83 dBm 36 Mbps 80 dBm 48 Mbps 76 dBm 54 Mbps 74 dBm MSCO 89 dBm MSC1 87 dBm MCS2 85 dBm MCS3 82 dBm MCS4 79 dBm MSC5 75 dBm MCS6 73 dBm MCS7 70 dBm MCS8 83 dBm MCS9 84 dBm MCS10 81 dBm MCS11 79 dBm MCS12 80 dBm MCS13 72 dBm MCS14 68 dBm MCS15 67 dBm MSCO 87 dBm MSC1 84 dBm MCS2 82 dBm MCS3 79 dBm MCS4 75 dBm MSC5 71 dBm MCS6 69 dBm MCS7 67 dBm MCS8 86 dBm MCS9 83 dBm MCS10 79 dBm MCS11 77 dBm MCS12 74 dBm MCS13 69 dBm MCS14 67 dBm MCS15 65 dBm 6 Mbps 88 dBm 9 Mbps 87 dBm 12 Mbps 86 dBm 18 Mbps 84 dBm 24 Mbps 82 dBm 36 Mbps 78 d

Download Pdf Manuals