Contents
1. Power Management Tools Environmental Sensor Qty optional External Battery Packs BP48V24 2U BP48V60RT 3U Power Distribution PDU12IEC PDUNV PDUMV20HV PDUV15 Rack Accessories SR2POST SR4POST SR25UB SR42UB SR42UBEXP SR47UB SR47UBEXP SR25UBSP1 SR42UBSP1 SR42UBEXPSP1 Rackmount Wallmount Kits 2POSTRMKITWM UPSHDEARKIT Shutdown Cable Kits AS400CABLE KIT SNMP Accessories SNMPWEBCARD Surge Protectors DTEL2 DNET1 DCATV Tower Stands 2 9USTAND External Battery Pack for UPS System External Battery Pack for UPS System Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Metered OU Vertical Rack PDU Metered Power Distribution Unit for Network Applications Safe reliable power distribution for critical networking equipment SmartRack Open Frame Rack Organize and Secure Network Rack Equipment SmartRack Open Frame Rack Organize and Secure Network Rack Equipment SmartRack Open Frame Rack 25U SmartRack enclosure with doors and side panels SmartRack Premium Enclosure Organize and Secure Network Rack Equipment SmartRack Premium Enclosure Organize and Secure Network Rack Equipment SmartRack Premium Enclosure Organize and Secure Network Rack Equipment SmartRack Premium Enclosure Organize and Secure Network Rack Equipment
2. Qty optional Qty optional Qty optional
3. SmartRack Premium Enclosure Special shock pallet packaging enables safe loading and re shipping of rack Enclosure SmartRack Premium Enclosure Special shock pallet packaging enables safe loading and re shipping of rack Enclosure SmartRack Premium Enclosure Special shock pallet packaging enables safe loading and re shipping of rack Enclosure Two Post Rackmount Wallmount Kit Front Mount UPS support brackets Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Servers Power Management Tools Internal SNMP Web Card Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for TV VCR coaxial lines Tower Stand Expandable Tower Base Stand UPS Accessory More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com EN products model cfm txtModellD 3970 2009 Tripp Lite All Rights Reserved Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional
4. with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipment ideal for unattended kiosk applications LINE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES EPO port Cold Start Appearance ZERO on line UPS continously converts incoming AC to DC then back to AC When commercial power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 160V 130V at load levels under 70 Below the switchover point output is supported from battery derived AC power Maintains continuous operation without using battery power during overvoltages to 275V Above the switchover point output is supported from battery derived AC power Supports Emergency Power Off via special order cabling contact Tripp Lite for more information Cold start capability allows turn on during blackouts from battery power Black all metal housing BATTERY PACK ACCESSORY optional Battery Pack Accessory optional CERTIFICATIONS Certifications WARRANTY Product Warranty Period Related Items BP48V24 2U BP48V60RT3U optional CE Europe SASO Kuwait 2 Years Environmental Monitoring ENVIROSENSE
5. Tripp Lite cr eres 1111 West 35th Street TRIPP LITE Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SUINT2200RTXL2UA SmartOnline UPS System True on line power for mission critical applications Highlights 2200VA 2 2kVA online double conversion extended run 2U rack tower UPS Maintains sine wave 200 208 220 230 240V 3 output during overvoltages to 275 and brownouts as low as 130V 50 60Hz auto sensing Simultaneous communications via HID compliant USB port serial port SNMP Web card slot and EPO interface Fault tolerant auto bypass mode current monitoring and switched PDU control via 2 single outlet load banks Input C20 inlet 230V Output 2 C19 4 C13 230V Jumpers Includes 1 C19 to C20 cable and 2 C13 to C14 cables 2 year warranty Description 2200VA on line double conversion UPS system for critical server network and telecommunications equipment 2U rackmount form factor with an installed depth of only 483 mm Expandable battery runtime with optional BP48V24 2U and BP48V60RT 3U external battery packs Full time sine wave 200 208 220 230 or 240V 3 output Online double conversion Uninterruptible Power Supply UPS actively converts raw incoming AC power to DC then re converts output back to completely regulated filtered AC output Operates continuously without using battery power during brownouts to 130V and overvoltages to 275V C20 inl
6. et input connection 2 C19 and 4 C13 output receptacles Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Supports simultaneous detailed monitoring of equipment load levels self test data and utility power conditions via all 3 network interfaces Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Integrated 2 bank PDU switching supports load shedding and remote reboot of connected equipment 3 stage metered current monitoring and battery charge status LEDs LED display panel easily rotates for better viewing in rackmount or tower configurations Dataline surge suppression for dialup DSL or network Ethernet connection Utility power and voltage regulation LEDs Audible alarm Self test Fault tolerant auto bypass mode 4 post rackmount accessories included 2 9USTAND tower kit and 2POSTRMKITWM two post rack amp wallmount accessories available Field replaceable hot swappable internal batteries and external battery packs Attractive all black color scheme 2 year warranty Applications Ideal for protection of critical equipment in server rooms internetworking closets and telecommunications systems in rackmount or to
7. interconnection cables available part P004 006 Input must be capable of providing approximately 10 amps at 200 240V AC nominal levels when used to full capacity 5 minutes with internal batteries 1600w 14 minutes with internal batteries 800w Supports extended runtime with optional external battery packs 48V DC Typical lifespan of 3 6 years before battery replacement is required Less than 6 hours to 80 RBC94 2U VOLTAGE REGULATION Voltage regulation description Overvoltage correction Brownout correction On line double conversion power conditioning maintains output within Maintains output of selected nominal 3 during overvoltages to Maintains output of selected nominal 3 during undervoltages to LEDS ALARMS amp SWITCHES Front panel LEDs LED STATUS DISPLAY line power green online green bypass yellow on battery green overload red battery low yellow 4 LED LOAD BATTERY LEVEL DISPLAY 100 75 50 25 LED display panel easily rotates for better viewing in rackmount Alarms Multi function audible alarm offers notification of UPS start backup operation low battery warning overload UPS fault and remote shutdown Switches To enable system turn on press ON switch UPS battery test press ON switch during normal AC operation buzzer silence press ON switch during battery operation and OFF press OFF switch SURGE NOISE SUPPRESSION AC surge 660 joules suppression AC s
8. ips with all mounting accessories for 4 post rackmount installation Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation Optional 2 9USTAND accessory enables small footprint upright tower placement Fault tolerant auto bypass maintains continuous utility output to connected equipment even in cases where the UPS suffers internal failure and requires maintenance Network interfaces support simultaneous communications via built in USB DB9 serial and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP UPS interface supports on battery low battery power restored AC voltage DC voltage output current monitoring battery charge current battery capacity AC line frequency timed inverter shutoff activate self test load bank output power control and remote reboot UPS nominal voltage adjustment and UPS line to battery power voltage setpoints Built in Emergency Power Off EPO interface with cable C20 inlet power connection C19 and C13 output receptacles Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks both of the C19 outlets are individually controllable Front panel LEDs offer current mon
9. itoring and battery charge level information UPS ships fully assembled in full compliance with DOT regulations no time consuming connection ofinternal batteries by user required Single line TEL DSL or network ethernet line surge suppression 2 year manufacturer s product warranty Specifications SYSTEM OVERVIEW Voltage compatibility 200 208 220 230 240V selectable Frequency 50 60 Hz auto sensing compatibility OUTPUT Output VA 2200 Output watts 1600 Output nominal 200 208 220 230 240V selectable voltage Output voltage Full time sine wave output within 2 of selected nominal 5 max THD regulation Output frequency Yes output is locked to 50 60Hz 0 05Hz regulation Outlet quantity type 4 1EC C13 amp 2 IEC C19 Customized load 2 controllable load banks support load shedding and remote reboot on demand of locked network devices each C19 management outlet is individually controllable receptacles Overload protection 15A input breaker INPUT Maximum input amps 9 7A 200V 9 3A 208V 8 8A 220V 8 5A 230V 8 1A 240V 1940 watts max Input connection type Input cord length Recommended Electrical Service BATTERY Full load runtime Half load runtime Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge IEC C20 inlet Unit is packed with one 10 ft IEC320 C19 to C20 interconnection cable additional C13 to C14
10. uppression Instantaneous response time Dataline suppression EMI RFI AC noise suppression PHYSICAL Shipping weight Ibs Shipping weight kg Shipping Dimensions HWD in Shipping Dimensions HWD cm Unit weight Ibs Unit weight kg Unit Dimensions HWD in Set of 8 wire RJ style interface jacks offer surge suppression for Yes 59 75 27 2 20 25 x 23 x 59 75 51 4 x 58 4 x 151 8 47 5 21 6 3 5 x 17 5 x 19 Unit Dimensions HWD cm Material of construction Form factors supported Cooling method Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max Audible Noise COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility 8 9 x 44 5 x 59 75 Steel Rack 2U Built in cooling fan User replaceable hot swap battery replacement supported via front 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 816 Audible Noise 50dBA At Front Side 1 Meter Includes USB and DB9 serial ports Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB interface Includes PowerAlert monitoring software and cabling Yes includes slot for optional SNMPWEBCARD accessory SNMPWEBCARD Yes compatible
11. wer applications Common applications include corporate or departmental servers workstations hubs routers bridges CAD CAM workstations concentrators IP telephony and traditional PBX switching systems Package Includes SUINT2200RTXL2Ua SmartOnline Double Conversion UPS System PowerAlert Software with USB and serial cabling Mounting hardware for 4 post rack enclosures Power cables 1 C19 to C20 and 2 C13 to C14 Instruction manual with warranty information Features SmartOnline high performance UPS system is ideal for critical voice data medical and industrial network applications True on line double conversion UPS provides perfectly regulated sine wave output within 3 of200 208 220 230 240V user selectable under all usage condition Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time Removes harmonic distortion fast electrical impulses frequency variations and other hard to solve power problems not addressed by other UPS types Corrects line voltage conditions as low as 130V and as high as 275V back to selectable 200 208 220 230 240V 3 values Standard internal battery set offers 14 minutes runtime at half load 800W and 5 minutes at full load 1600W Extended Runtime with BP48V24 2U limit 1 or BP48V60RT3U multi pack compatible external battery packs Compact rackmount form factor installs using only 2 rack spaces 2U with a maximum installed depth of only 483 mm Sh