1. Product Information Specifications RS 485 Pin out COM 2 COM 2 RS 485 Pin RS 485 Signal 1 2 Do not connect 3 RxD TxD 4 Reserved 5 6 Reserved 7 Do not connect 8 RxD TxD 9 Shell Chassis GND Q The COM 2 RS 485 port is not equipped with terminating ground current limiting or pull up resistors The installer must provide them Note Configure a building management system To configure the MODBUS RTU building management system interface select Build Management System from the Event Management menu 18 InfraStruXure Manager Life Support Policy General policy American Power Conversion APC does not recommend the use of any of its products in the following situations In life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness e In direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances Examples of life support devices The term life support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whet
2. in which case the user may be required to take corrective actions COREL HAULER ES IEE BEA iz VCCI Ode ICEX ITA A TEBE CT OORE x AER CEH FAL BRBGBeNSHROPTCEBSVET TORPANT 1E FAA DWAR EGET O kI CARENA T EDET www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information WwWw apc com support Global support searching APC Knowledge Base and using e support e Contact an APC Customer Support center by telephone or e mail Regional centers Direct InfraStruXure Customer Support Line 1 877 537 0607 toll free APC headquarters U S Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702000 Ireland Japan 0 35434 2021 Australia New Zealand South Pacific area 61 2 9955 9366 Australia Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for infor
3. access to the InfraStruXure Manager server l Connect a computer to the hub on the private network That computer must have the InfraStruXure Manager client installed If it does not connect to the InfraStruXure Manager server and select to install the client when prompted Reboot the InfraStruXure Manager server Q This may require physically disconnecting and reconnecting InfraStruXure Manager at its input power source Note Use the InfraStruXure Manager client step 1 to connect to the InfraStruXure Manager server When the Server Log On display appears use admin lowercase as the Username and apc lowercase as the Password to log on to the server Ifa logon attempt fails try again the InfraStruXure Manager server may not have finished restarting After the Server Log On display appears you must Note 108 on within about eight minutes or you must repeat step 1 through step 4 Select Authentication Settings in the System Management Menu to correct the problem that required using this procedure Click Configure Local Users to use the Configure local users display to define a username and password for Administrator access Change the Authentication Method setting to Local only InfraStruXure Manager 13 Enable Remote Monitoring APC can monitor your InfraStruXure Manager and the devices it manages and notify you of events via e mail pager or phone If you decide to u
4. cables to InfraStruXure devices 7 Route network cables to the InfraStruXure Manager switch or hub 8 Install and route data cables alternative routing 8 Connect the InfraStruXure Manager and switch or hub 9 Connect the InfraStruXure Manager to your LAN 9 Apply power to the InfraStruXure Manager and switch or hub 10 Remove power from the InfraStruXure Manager and switch or hub 10 Initial CONTIQUIATION ii Configure the InfraStruXure Manager o 11 Configure the InfraStruXure Manager from the Private Network APC LAN 11 Configure the InfraStruXure Manager from the Public Network User LAN 12 How to Restore Access to the InfraStruXure Manager Server 13 Enable Remote Monitoring 0000 lt lt e eee eee 14 InfraStruXure Manager i Product Information c ssc s xs e x c x x e x e e xe eee eee 16 APC InfraStruXure Manager front panel 16 Sp cifications sa Meee eee A 17 APC InfraStruXure Manager 2 000200eee ee eee 17 RS 485 Pin out COM 2 ee 18 Configure a building management system 18 Life SUpport Poli y 22 ewe ek eee twee FEES Eee eee ee ee 19 General policy 20202 ee eee eee eee ee eee 19 Examples of life support devices o o ooooooo oo 19 Warranty and Service 2 ee eee a ee ees 20 Limited warranty os sei ma a Rie a 20 Warranty limitations 2 6 e 20 Obtaining ser
5. create problems under the floor when data cables are too close to any power cables Even if data transmission is successful after the initial installation later additions to power cabling under the floor for other equipment in your data center can jeopardize the integrity of the data transmission for your InfraStruXure system 8 InfraStruXure Manager Installation Communication Connection Connect the InfraStruXure Manager and switch or hub This section is for InfraStruXure system installations 1 Connect the InfraStruXure Manager s APC LAN port to any network port on the hub using the CAT 5 network jumper cable provided E Cedo Connect the InfraStruXure Manager to your LAN 1 Connect a port on your LAN to the InfraStruXure Manager s User LAN port AUT o ass Ill InfraStruXure Manager 9 Installation Communication Connection Apply power to the InfraStruXure Manager and switch or hub After you install the InfraStruXure Manager and switch or hub and make all of the communication connections connect the power cords to a Rack PDU within the enclosure to apply power to the InfraStruXure Manager Remove
6. power from the InfraStruXure Manager and switch or hub If you need to remove power from the InfraStruXure Manager and switch or hub you must first shut down the manager from the client interface 1 From the System Management menu select Server and then Shutdown or Reboot Server 2 In the Shutdown or Reboot Server window select Shut Down Server and click OK 3 After the HDD LED has been inactive for 30 seconds unplug the InfraStruXure Manager and switch or hub from the Rack PDU 10 InfraStruXure Manager Initial Configuration Configure the InfraStruXure Manager To configure the InfraStruXure Manager for the first time you must connect to the manager and run the APC InfraStruXure Manager Setup Wizard on the client interface You have two options for connecting to the manager e Connect from the private network APC LAN with a computer connected to the APC switch or hub This method is recommended if you do not know the IP address assigned to the InfraStruXure Manager on the public network User LAN or your network does not use a DHCP server to assign IP addresses e Connect from the public network User LAN You can use this method if you know the IP address assigned to the InfraStruXure Manager on the public network User LAN Configure the InfraStruXure Manager from the Private Network APC LAN 1 Connect a computer to a network port on the APC switch or hub The computer must meet the following r
7. ation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction Obtaining service 20 To obtain support for problems with your InfraStruXure Manager 1 Note the serial number and date of purchase Obtain the serial number from the rear of the box or from the About option of the Help menu 2 Contact Customer Support at a phone number on the back cover of this manual A technician will try to help you solve the problem by phone 3 If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement 4 Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number and daytime phone number a copy of the sales receipt and a check as payment if ap
8. ber the disk is being accessed O Pwr Power LED When this LED is green the InfraStruXure Manager is receiving input power O Monitor VGA monitor port reserved for future use O Reset Switch that restarts the APC InfraStruXure Manager Kbd PS 2 Keyboard port reserved for future use User LAN Ethernet port for connecting to the user s network APCLAN Ethernet port for connecting to the private APC network DO 100 Speed LED Off indicates the network is operating normally at 10 Mbps Amber indicates the network is operating normally at 100 Mbps 12 Rx Tx Rx Tx LED Flashing green indicates activity on the port Off indicates that there is no activity on the port InfraStruXure Manager Specifications APC InfraStruXure Manager Electrical Input 100 240 VAC 50 60 Hz 0 7 A Physical Dimensions H x W x D Unit 1 75 17 0 x 6 75 in 4 5 x 43 2 x 17 2 cm Shipping 8 5 x 22 75 x 13 25 in 21 5 x 57 78 x 33 65 cm Weight Unit 6 6 lb 3 0 kg Shipping weight 11 5 Ib 5 2 kg Environmental Temperature Operating 41 to 95 F 5 to 35 C Storage 5 to 122 F 15 to 50 C Elevation Operating 10 000 ft 3000 m above MSL Humidity Operating 5 95 RH non condensing Storage 5 95 RH non condensing Compliance Approvals UL cUL VDE FCC Class A AS NZS 3548 Class A VCCI Class A ICES 003 Class A EN55022 EN55024 EN 61000 3 2 EN 61000 3 3 EN60950 CE InfraStruXure Manager 17
9. close the Wizard Configure the InfraStruXure Manager from the Public Network User LAN 1 Connect a computer to the public network User LAN 2 Open Microsoft Internet Explorer browser version 5 5 or higher and enter the IP address assigned to the APC InfraStruXure Manager Ask your network administrator or check the DHCP server for this IP address 3 Ifthe Security Warning appears click Yes to download the APC InfraStruXure Manager Client 4 When the Server Log On display appears use ape lowercase for both the username and password and click Connect 5 In the Confirm display click Yes to run the APC InfraStruXure Manager Setup Wizard Q If you click No you can run the wizard at any time From the System Management menu select the Server option and then select Setup Wizard Note 6 On the License Key page of the wizard enter the license key to enable the InfraStruXure Manager to manage APC devices on the private network APC LAN or discover and manage APC devices on the public network User LAN 7 When you are done configuring your InfraStruXure Manager click Finish to close the Wizard 12 InfraStruXure Manager How to Restore Access to the InfraStruXure Manager Server If the username or password used for local Administrator access becomes unknown or RADIUS only is selected in the Authentication Settings display and a RADIUS server is unavailable you can use the following procedure to restore
10. equirements It must be configured to automatically obtain an IP address through DHCP It must be running TCP IP as a network protocol The browser must be Microsoft Internet Explorer version 5 5 or higher 2 Release and renew your computer s IP address to assign it an address on the APC LAN 3 Open Microsoft Internet Explorer browser version 5 5 or higher and enter the APC LAN IP address for the InfraStruXure Manager Use 192 168 1 1 as the default IP address for the InfraStruXure Manager on the APC LAN Use 10 0 1 1 if for any reason you cannot use the default IP address above 4 If the Security Warning appears click Yes to download the APC InfraStruXure Manager Client 5 When the Server Log On display appears use ape lowercase for both the username and password and click Connect 6 In the Confirm display click Yes to run the APC InfraStruXure Manager Setup Wizard InfraStruXure Manager 11 Initial Configuration Configure the InfraStruXure Manager Q If you click No you can run the wizard at any time From the System Management menu select the Server option and then select Setup Wizard Note 7 On the License Key page of the wizard enter the license key to enable the InfraStruXure Manager to manage APC devices on the private network APC LAN or discover and manage APC devices on the public network User LAN 8 When you are done configuring your InfraStruXure Manager click Finish to
11. her used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care InfraStruXure Manager 19 Warranty and Service Limited warranty APC warrants the InfraStruXure Manager to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Warranty limitations Except as provided herein APC makes no warranties expressed or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limit
12. ipped with rack mounting brackets Install the brackets in the appropriate position for your rack and mount the unit The unit is 1U high If the unit is mounted in an enclosure instead of an open rack the maximum ambient temperature in the enclosure should be no greater than 95 F 35 C When you install equipment in the rack make sure it does not interfere with the air flow required for safe operation for the equipment e When you mount equipment in the rack make sure you do not cause a hazardous condition because of an uneven mechanical load e When you connect equipment to the supply circuit avoid overloading the circuits which could jeopardize over current protection and damage the supply wiring See ratings on the equipment nameplates for guidance e Maintain reliable earth grounding of the unit particularly for supply connections e g when PDUs that are not directly connected to the branch circuit are used Equipment containing a battery This equipment contains a non replaceable lithium coin cell battery Danger of explosion if the battery is incorrectly replaced Call APC service for A battery replacement This battery must be replaced only with the same or Warning equivalent type The battery should be returned to APC for disposal A The InfraStruXure Manager contains no user serviceable parts Warning InfraStruXure Manager 3 Install the InfraStruXure Manager Attach mounting brackets to the InfraSt
13. mation on how to obtain local customer support Entire contents copyright O 2004 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo NetShelter PowerChute and InfraStruXure are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only a INI n HH aos
14. ng screws provided with the enclosure to secure the brackets to the enclosure Ar MN The switch or hub and the InfraStruXure Manager are not required to be installed in the same rack as they are in the installation described here Note 6 InfraStruXure Manager Communication Connection Network overview The InfraStruXure Manager provides for the management of other networked APC devices It connects to both your existing network User LAN and a private APC network APC LAN to manage connected APC devices Use the APC LAN for APC devices whenever possible Public network Private network poison o o r bo RR OO Managed device 1 User LAN APC switch 1 User LAN port APC LAN port I Connect network cables to InfraStruXure devices 1 Connect a CAT 5 network cable to the network port on each APC device or each APC device s management card InfraStruXure Manager can manage any APC device with a network port Note 2 Connect CAT 5 network cables to the ethernet ports on the Rack PDUs and on the monitoring unit in the InfraStruXure PDU If you are running PowerChute Network Shutdown software with an InfraStruXure system s UPS that is connected to the private network you must purchase a second Network Management card Install this card in the second slot in the UPS and connect it Note 0 he public network You do not need a second management card if the UPS is connected to the public netw
15. ork InfraStruXure Manager 7 Installation Communication Connection Route network cables to the InfraStruXure Manager switch or hub Overhead routing This section is for InfraStruXure system installations 1 Ensure that the APC Shielding Partitions and Cable Ladders are installed on the NetShelter enclosures and the InfraStruXure PDUs 2 Run the Cat 5 network cables provided from each APC device to the switch or hub a Start with the device farthest from the switch or hub and use the longest supplied CAT 5 cable b Bundle cables together and route the bundles in the data cable troughs along rows and across ladders if necessary 3 Connect each APC device s network cable to any available port on the switch or hub Install and route data cables alternative routing If possible route data cables overhead as described in Overhead routing on this page Using APC Shielding Partitions and Cable Ladders with your InfraStruXure Note System reduces problems related to induced voltages for data transmission If you must route data cables under a raised floor Do not route data cables inside an InfraStruXure PDU to the floor either within the power cable conduit or in any other location Induced voltages from the power cables may interfere with data transmission Route data cables out the roof of the InfraStruXure PDU and down inside the first NetShelter enclosure to the floor Induced voltages can also
16. plicable 5 Mark the RMA number clearly on the outside of the shipping carton 6 Ship by insured prepaid carrier to the address provided by the Customer Support technician InfraStruXure Manager Radio Frequency Interference USA FCC Canada ICES Japan VCCI Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s Warning authority to operate this equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference The user will bear sole responsibility for correcting such interference This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may occur
17. ruXure Manager 1 Attach the left and right mounting brackets to the InfraStruXure Manager using two flat head 2 Phillips screws provided for each bracket EJ See the manufacturer s documentation for the switch or hub for specific installation instructions See also 4 InfraStruXure Manager Installation Install the InfraStruXure Manager Mount the InfraStruXure Manager and switch or hub in an enclosure Q This procedure describes how to install components in an APC NetShelter enclosure Ifyou are installing components in a different enclosure the procedure may vary Note Leave room above the switch or hub to route data cables To install the InfraStruXure Manager in a NetShelter enclosure 1 Insert caged nuts provided with the enclosure above and below the numbered holes on the vertical mounting rails 1U o 00o 00 G A Install each caged nut horizontally Do not install the caged nut vertically with the sides of the caged nut engaging the top and bottom of the square hole Warning a Hook one side of the caged nut assembly through the far side of the hole b Insert the caged nut into the square hole c Place the caged nut tool provided on the other side of the caged nut and pull to snap it into position InfraStruXure Manager 5 Installation Install the InfraStruXure Manager 2 Align the mounting holes on the brackets with the caged nuts you installed in step 1 and insert two mounti
18. se APC s Remote Monitoring Service RMS follow these steps 1 From the Event Management menu select Remote Monitoring Service 2 In the APC Remote Monitoring Service Registration window Click the RMS Settings button at the lower right PL ride Mural ote Spry e Blain APC Remote Monitoring Service Registration Tommie cick TB ip dalines the teamed ceili Pen en b s AMS anal hak App whan you ss chante HMS pos musi chek AGL do niwe Re change 3 In the Access RMS Settings window click the New RMS Customer button unless you have already registered for RMS 14 InfraStruXure Manager Initial Configuration Enable Remote Monitoring 4 In the RMS Settings window fill in all of the required fields on the Contact Information and Company Information tabs and then click Save lrdnrrsal inn 6 In the APC Remote Monitoring Service Registration window select the Enable APC s Remote Monitoring Service check box and click Apply 7 Visit http rms apec com to complete the RMS configuration InfraStruXure Manager 15 Product Information APC InfraStruXure Manager front panel www ape com InfraStruXure w Item Function O COM 2 RS 485 port that allows integration with a Building RS 485 Management System using the MODBUS protocol OQ USBI Universal Serial Bus port USB 1 1 COMI RS 232 port RS 232 HDD Hard disk drive LED When this LED is am
19. vice lt lt e e eee eee eee ee 20 USA FEC iis ida a Pee ae ee ae eae el aa ae 23 Canada ICES RR R TR RR RT ee 23 Japan aa chs ce a iaa dd 23 ii InfraStruXure Manager Product Description Overview Inventory O APC InfraStruXure Manager A 1U management device The InfraStruXure Manager coordinates the management functions of other APC devices that provide for the management of InfraStruXure other APC power distribution systems and cooling solutions O Rack mount brackets Brackets used to install the InfraStruXure Manager in a standard 19 inch 482 mm enclosure or rack Power Cords NEMA 5 15P to IEC 320 C13 and an IEC 320 C13 to IEC 320 C14 power cord Use the cord appropriate for your application Network Cable CAT 5 network cable Receiving inspection Inspect the package and contents for shipping damage and make sure that all parts were sent Report any damage immediately to the shipping agent and report missing contents damage or other problems immediately to APC or your APC reseller InfraStruXure Manager 1 Product Description Overview Please recycle The shipping materials are recyclable Please save them for later use or dispose of them appropriately Disclaimer American Power Conversion is not responsible for damage sustained during reshipment of this product 2 InfraStruXure Manager Safety Rack mounting safety The APC InfraStruXure Manager is sh
20. www apc com InfraStruXure Manager Installation and Configuration ADE LA SR 2 lt LiL LZ This manual is available in English on the enclosed CD Dieses Handbuch ist in Deutsch auf der beiliegenden CD ROM verf gbar Deze handleiding staat in het Nederlands op de bijgevoegde cd Este manual est disponible en espa ol en el CD ROM adjunto Ce manuel est disponible en francais sur le CD ROM ci inclus Questo manuale disponibile in italiano nel CD ROM allegato AVIAV IO HABRA ARO CD ROM ST IZ LT T Instrukcja Obslugi w j zyku polskim jest dost pna na CD Mucrpykunma nO UCIO Ib3OBAHMIO HA PYCCKOM A3bIKe npnJaraerca na 1ucke CD Contents PFOGUCE DESCFIDUIOR ic voce hs sat ee ccees rs OVER VIC WG lt a is A EA AR Rama 1 INVENtON A il RR 1 Receiving inspection lt lt lt lt lt ee sa 1 Please recycle 2 2228 ce eek a a a 2 DISCLAIMER occ cee ee a aa a ee a ae 2 Safety ERA AAA WR AAA 3 Rack mounting safety oooooooommmooooooooos 3 Equipment containing a battery 0cooo oo ooo 3 Tea dT Ey ON sis a ls dt do Rio dd ales oe Install the InfraStruXure Manager oo o o ooooooo ooo 4 Attach mounting brackets to the InfraStruXure Manager 4 Mount the InfraStruXure Manager and switch or hub in an enclosure 5 Communication Connection oooooooooooo ooo 7 Network overview 000 cee ee ooo 7 Connect network