Home

Eaton Evolution S 1750 VA Convertible RT2U Tower / Rack UPS

image

Contents

1. www mgeups cc UPS ICE ENTREPRISE IT INESS amp NETWORKS Evolution 650 850 1150 1550 2000 VA Evolution S 1250 1750 2500 3000 va High density protection for network devices Maximum availability Powershare The Evolution output sockets are individually controlled to provide load shedding to maximise the backup time and provide remote reboot and sequential start up as Standard Continuous power supply Hot swappable batteries The HotSwap MBP Maintenance By Pass module allows the UPS to be replaced without interrupting the power supply HotSwap MBP 4DIN Long backup times 1 to 4 EXB battery units can be added to the Evolution S from 1250 to 3000VA z De Minimum total cost of ownership Line interactive HF technology the best price performance ratio No additional cost rack 1U and RT models are provided with the rail kits Remote supervision A wide range of options using the Solution Pac supplied SNMP and HTML and relay outputs TE pi e paie pE ai t m ALL EET ETE T CE E L SET j Network Management Card and MGE EPM Superviseur Rack 1U ana r Tower models Ve E RT models Flexibility Evolution has unmatched Flexibility Format Evolution is available in tower format rack 1U format RT2U convertible rack tower version optimised for rack mounting or RT3U for tower or short depth racks Connections With Flex
2. Rating 650 VA 850 VA 2000 VA 1250 VA Po AROW L 600w 770W Tro Ww SOOW 2250W 2700W Format Tower or 1U Rack RT2U tower rack 2U E ERTU Electrical characteristics echnology Line Interactive High Frequency Booster Fader Input voltage and frequency 160V 294V adjustable to 150V 294V ranges without using 47 to 70 Hz 50 Hz system 56 5 to 70 Hz 60 Hz system batteries 230 V 6 10 50 60 Hz 0 1 1 IEC C14 10 A socket 4 IEC C13 10 A 1 IEC C20 16 A socke 8 IEC C13 10 A sockets IEC C19 16 A socket 2 groups of 1 x IEC C13 10 A 4 FR Schuko sockets or 3 BS sockets or 6 IEC 10A sockets or terminal blocks HW version 8 FR Schuko sockets or 6 BS sockets or 12 IEC 10A sockets 8 IEC C13 10 A Batteries Typical backup times for 50 and 70 of the VA Evolution Evolution S 16 7mn 14 7mn 14 7mn 14 7mn 20 14 mn 14 9 mn 17 11 mn 15 10 mn Evolution S 1 EXB 6 1 05 60 mn 60 36 mn 85 55 mn 60 42 mn Evolution S 4 EXB 399 200 mn 180 115 mn 290 200 mn 210 135 mn Battery management Automatic weekly test period adjustable automatic recognition of external battery units gt continuous maximisation of backup time deep discharge protection Communication ports 1 USB port 1 RS232 serial port and relay contacts mini terminal block for remote ON OFF and Remote Power Off Communications card slots 1 slot for NMC Minislot 2006 card included in Netpack versions or NMC ModBus JBus or MC Contact
3. PDU and HotSwap MBP the Evolution can be connected by sockets or terminal blocks They can be installed as required behind on the side or on top of the unit Compatible with high power factor loads The Evolution S are rated for 0 9 total power factor 1250 VA 1150 W 1750 VA 1600 W 2500 VA 2250 W and 3000 VA 2700 W Interfaces USB serial remote Start stop slot for optional communications card amp v E m amp S A Q gt Qr Qr Ly A Z gt Ly TELECOMS ime Protection for 1 to 15 servers ideal for p network devices rack mounted servers conventional rack mounted or tower servers network storage systems With its extremely compact size the Evolution is the ideal solution for making the best use of the available space Thanks to its many installation options the Evolution is easily integrated into any environment offices point of sale terminals 19 racks etc ER D To MGE UPS SYSTEMS Evolution 1550 MGE PowerServices 2 year guarantee including batteries Standard exchange of product in case of failure including batteries Associated services Warranty 3 year extended guarantee 1 Depending on the country see www mgeups com services Communications software and hardware Solution Pac software on CD ROM with each UPS For monitoring the server s powered by the UPS and for local and remote UPS
4. Supervision Network Management Card NMC 2006 For connecting the UPS to an Ethernet 10 100 network raising SNMP alarms and Supervising the UPS using a simple browser interface NMC environment sensor Monitoring the temperature humidity and 2 relay contacts via SNMP or HTML Enterprise Power Manager supervisor For comprehensive management of a set of UPSs using a Windows PC Management Pac 2 suite NMS integration kit HP OpenView IBM Tivoli Netview CA Unicenter etc Management Card Contacts Serial Add a second relay contacts or Serial port to the UPS UPS Control remote display To monitor the UPS status up to 25m from the unit MGE UPS SYSTEMS Headquarters 140 avenue Jean Kuntzmann ZIRST Montbonnot Saint Martin 38334 Saint Ismier Cedex France Tel 33 0 4 76 18 30 00 EVOL523UK 06 06 Full user interface ON OFF button for UPS and outlets Load protected not protected LED Utilised power level Battery charge level Status of switchable outlets Panel for replacing batteries without interrupting the output 1 USB port 1 serial port remote ON OFF and emergency stop inputs EXB battery unit connector EXB units recognised automatically 4 IEC 10A sockets including 2 programmable sockets 8 IEC 10A sockets including 4 programmable sockets Communications card slot Evolution S 3000 RT2U Netpack Technical characteristics Evolutions _ __ re eee E E EE
5. h the characteristics indicated by the images and text unless they are confirmed by us All the brand names referred to in this document are protected by copyright Publication MGE UPS SYSTEMS June 2006 Design and rewriting 3c evolution com Integration Pamplemousse 33 4 79 37 87 66 Translation TTP 33 4 78 66 47 99
6. s Serial Operating conditions standards and approvals Operating temperature 00 35C 0 to 40 C lt 40dbA lt 45 dBA lt 50 dBA Performance Safety EMC IEC EN 62040 1 1 Safety IEC EN 62040 2 EN 50091 2 class B EMC IEC EN 62040 3 Performance IEC EN 61000 4 2 61000 4 3 61000 4 4 61000 4 5 61000 4 6 61000 4 8 EMI Approvals CE CB report TUV Dimensions WxDxH in mm Weight in kg 234 43 2 IU 43 2 1U ST a teh ee a ES oan 10 1 16 1 166 20 34 3 RT3U Dimensions of EMBO 4405 09 86 2 2U 440 484 130 7 BU Weight of the EXB 440 634 86 2 RT2U 440 509 86 2 20 44944 130 7 RT3U 1 Up to 40 Hz in low sensitivity mode programmable using Personal Solution Pac software 2 Adjustable to 200 V 10 derating of output power 208 V 220 V 230 V 240 V 3 USB and RS232 ports cannot be used simultaneously 2000 1250 1750 2500 S3000 S 3000 RT2U RT2U RT2U RT2U RT3U RT2U Netpack Netpack ee ee a ee O Rack1U SBC Ee Ree SS eS eS aes Convertible Tower Rack 0 8460 68456 68459 68463 68464 68465 EXB Models o gt 68470 68470 68471 68471 68471 NMC card included in Netpack versions Part Numbers THE UNINTERRUPTIBLE POWER PROVIDER ISO 9001 VERSION 2000 cE A TOV Rheintand ha CENELEC Due to developments in technical standards and the equipment described in this document we cannot be held liable for compliance wit

Download Pdf Manuals

image

Related Search

Related Contents

Samsung PS51D6915DK Bruksanvisning  Promate uniCase.8  Appareil photo numérique Digital Camera  Samsung AR18JSFNCWKNEU Manual de Usuario  Audio-Technica U891RCX User's Manual  Microsoft ES4612 User's Manual  WI.DP1203 WI.DP1203-XXX-EVM-R™ and RK-WI  Conditons de vente et de livraison de l`Egro Suisse SA  Taro-00 表紙.jtdc  USER MANUAL - Hatteland Display AS  