Home
Emerson NFINITY POWER MODULE
Contents
1. 0 Liebert EMERSON Network Powe The Problem Is That You Depend On Your Network More Than Ever The digital lifeblood of many organizations computers servers phones dat acom links now resides on networks outside of the traditional glass house protection This may make companies more flexible and responsive but it also makes them far more vulnerable to power problems and the threat of cata strophic losses in sales customers pro ductivity your business lifeblood The Solution Is A UPS Designed Like Never Before Now for the first time your can achieve the highest levels of UPS reliability in a system that is sized to protect network applications The Liebert Nfinity UPS is designed for use with workstations servers networks telecommunications equip ment or other sensitive electronics It provides continuous high quality AC power to your mission critical systems protecting them from any power aberrations due to blackouts brownouts surges or noise interference The Nfinity power system is a scalable 4 to 16 kVA UPS designed with N x parallel redundancy to provide a fault tolerant network of power protection formaximum systems availability Its modular design makes Nfinity the most adapt able UPS on the market offering easy upgrades and servicing Scalability Is Just The Start Of The Value Configure the system that s right for you today and tomorrow Everything you need shipped complete ready f
2. Longer Battery Run Time The system s flexible frame design allows battery backup times to be customized to customer needs while maintaining a smaller footprint To extend run times just add battery modules Nfinity also has a faster recharge time than similar units Hot Swappable Hot swappable modules allow you to add or replace power battery and control modules without shutting the load down or affecting power to it In redundant mode this means no downtime for repair Nfinity s hot swappable modules also make it easy for the user to handle basic service Cabinet Stands Small Stays Small Nfinity s compact efficient design allows you to pack more power and battery capability into a much smaller sized unit so it takes up less of your valuable floor space Initial System Upgrade Extend System 4 kVA Redundant System Capacity Run Time 8 kVA Redundant 8 kVA Redundant Power Power Modules Modules Power Modules Blank Blank Batteries Batteries Batteries Thesystem contro module provides communications and contreHor the unit The system utilizes independent 4 kVA power modules Up to four power modules can be operating at one time Each battery module is composed of ten individual 12 volt batteries encased in a plastic housing Power and battery modules are housed in identical bays within the frame Power modules must be contained in the top half of the frame while bat tery modules can be utilized
3. 12 Bay frame 20kVA rating available for 3x1 models only While every precaution has been taken to ensure accuracy and completeness in this brochure Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2002 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice All names referred to are trademarks or registered trademarks of their respective owners Liebert HIROSS UPS Headquarters Liebert HIROSS Services Headquarters Liebert HIROSS United Kingdom Via Gioacchino Rossini 6 Via Leonardo da Vinci 8 Globe Park Marlow Bucks SL71YG 20098 S Giuliano Milanese MI 35028 Piove di Sacco PD tel 44 1628 403236 fax 44 1628 403294 tel 39 02 982501 fax 39 02 98250337 tel 39 049 9719111 fax 39 049 9717053 info ups liebert hiross com service liebert hiross com http ups liebert hiross com NFIN 01 12 02 Conte Oggioni Partners Printed in Italy
4. 2 Environmental Operating Temperature max C 0 40 Relative Humidity Yo 0 95 non condensing Maximum Operating Altitude m 3000 Nominal Heat Dissipation W 31 933 1244 16kVA 1265 20kVA 4KVA 8kVa 12kVA Acoustic Noise Level dBA lt 62 1m Input Data Nominal Input Voltage VAC 220 230 240 for 1x1 units 380 400 415 for 3x1 units 12 bay only Power Factor coso 98 for 1x1 units 80 for 3x1 units Input Frequency nominal Hz 50 Input Frequency Range Hz 40 70 Battery Module Number Of Lead Acid Batteries 10 Number Of Battery Cells 60 Battery Capacity AH 9 Autonomy Time full load minutes 7 with an equal number of Battery amp Power modules in non redundant configuration Maximum Charge Current full load A 3 Nominal Voltage VDC 120 Recharge Time Hr 3 5 90 capacity Output Data Units Output Voltage VAC 220 230 240 220 reguires output transformer Voltage Regulation Yo 3 Voltage Stability 100 step load Yo 7 Recovery Time msec 96 Voltage distortion lt 3 THD linear load lt 7 THD non linear load Output Frequency Hz 50 Efficiency at 100 load 91 OUO aia app gt 100 110 for 10 min gt 100 110 operates indefinitely 111 150 operates for 8 sec 111 150 operates for 8 sec 151 200 operates for 0 25 sec 151 200 operates for 0 25 sec gt 201 operates for 2 cycles gt 201 operates for 2 cycles for 1x1 units for 3x1 units NOTE 3x1 units available in 12 Bay frames only 16kVA 1x1 requires
5. Intellislot User Interface Switch SW2 Terminal Communications Ports DB 9 Communication Ports Power Module Bays Battery Module Bays Output Power Terminal 220 240 Jumper Transformer Option Only Input Power Terminal Input Earth Terminal Manual pa Input Circuit Switch Breaker CB1 Intake Cooling External Battery Fans Connection Transformer Option Only with bezels removed with access plates removed Ms Bay Model Displayed Also Available 12 Bay Model Extended Battery Cabinet Power Monitoring And Network Shutdown With Multilink Software MbttiLinkTM is the perfect complement to the Liebert Nfinity UPS because it prevents unex pected server shutdowns protects data and minimizes downtime The software provides unattended orderly shutdown for one computer or many and is especially effective with large server farms MultiLink has full event management and displays UPS instrumentation on screen MultiLink is available for all popular operating systems and can be downloaded from the Liebert web at www liebert com General Features General amp Environmental Unit Rating kVA 4 8 12 16 20 kW 2 8 5 6 8 4 11 2 14 Conducted and Radiated EMC Levels EN50091 2 Class A Compliant Safety Standards EN50091 1 EN 60950 CE Low Voltage Directive Compliant Immunity Standards EN61000 4 2 3 4 5 6 8 Bay 12 Bay Dimensions Width mm 508 Dimensions Depth mm 711 Dimensions Height mm 1016 137
6. ards that enable up to four client computers to monitor UPS status Relay contact cards to provide contact closures or remote monitoring of alarm conditions The system also communicates to and monitors internal and extended battery cabinets Iligent Power Modules provide protection against power outages spikes surges noise and sags Designed in 4kVA building blocks they utilize patent pending current sharing technology that ensures premium quality power Nfinity power modules feature a power factor corrected PFC rectifier to create a sinusoidal input current waveform This allows the system to use utility power more efficiently and reduces reflected distortion A true on line system Nfinity provides continuous regenerated sinewave output power Nfinity is a 4 to 16 kVA UPS designed with N x parallel redundancy to provide a fault tolerant network of power protec tion for maximum systems availability Redundant Power Modules parallel redundancy is achieved by adding extra powermodules that equally share the electrical load Wider Input Voltage Window A wider variable input voltage range minimizes transfer to battery to increase battery life For lighter loads low line trans fer can range down to 110V Generator Compatible Full time output voltage and frequency regulation is provided a necessity for sensitive electronic equipment and a must for sites with back up generators Highest Overload Capability N
7. finity offers the highest overload capability of any system in its class capable of sustaining 110 of the system s rated load for an extended period of time Power Module Battery Module Shipping screws Status LED Fault LED Cooling Fan Lever VX m La Se Tan ER x NS gt gt m u a m m u m a u u m gt PS wo u EE Longer Runtimes For Maximum Availability IntelliBattery Module Nfinity s innovative battery module continuously monitors the battery s voltage current and temperature to determine the state of its batteries and predict performance Each module contains an intel ligent battery sensing circuit that will take it off line if a problem is detected so as not to affect the pefor mance of other good battery modules in the system Extended Battery Cabinets The Nfinity extended battery cabinet is available when extra run time is critical to your protected loads This unit has 12 bays that accept up to 12 standard Nfinity intelligent battery modules allowing you to add battery capacity as needs change A built in microprocessor in each battery module provides the intelligence and communication capability to allow the module to auto matically remove itself from the critical DC bus if
8. in any of the bays This allows battery back up times to be configured to customer needs Fasteners Fault LED Status LED User Interface Module System Control Module IntelliControl Module The system control module works with the user interface to provide vital information about the condition ofthe power and battery modules The use of a paired system control provides full systems functionality in the event of any single failure and ensures that operations and communications are always available Communications Capability The Liebert Nfinity UPS incorporates extensive firmware designed to provide a comprehensive range of control and operating information as well as communications capability User Interface Control Panel The user interface module is the main source of communication between the Nfinity UPS and the user It features an easy to read LCD display and LED mimic diagram The control panel informs the user of the status of the UPS includ ing the power and battery modules and allows you to configure the system to fit specific needs or preferences You can also review the event log and even receive instructions on replacing modules Redundant Monitoring Options Dry contacts and a serial communications port are standard The unit also includes four Intellislot ports for multiple user options including SNMP cards that allow the Nfinity to communicate with an Ethernet network MultiPort4 c
9. necessary The extended battery cabinet reports and tracks individual modu le capacity temperature and charge level as well as other data and reports this information to the Nfinity system control Bi Nfinity Battery Run Times min Quantity of Extended Battery Cabinets IO 0 00 0 Y IN ISO 12 Bay 3x1 Units co o EN N i les les gt 12 Bay 1x1 Units F O N Y 17 e 18 gt 19 x 21 an gt 22 A 23 00 25 N 00 w O N amp o oO co gt N 47 al al O al Y O 00 co NOTE In Red backup times for 8 Bay units in Blue backup times for 3x1 up to 20kVA units Backup times are in minutes and are based on resistive loading at an ambient temperature of 25 C under controlled conditions for non redundant configurations Extended battery cabinets are fully loaded with 12 battery modules Extended battery cabinets assume that the UPS frame is fitted with all available battery modules Nfinity is the first redundant UPS of its kind that ships as a complete pre configured system that is tested at the factory Everything you need is included in a single package that s ready to roll in an hook up Control Enable REPO
10. or final connection Intelligence Means Maximum Performance Power responsiveness The ability to communicate Self diagnosis Highest Levels Of Redundancy Mean Maximum Systems Availability Redundancy at all the critical points of UPS operation Maintainability without shutdown Liebert Puts It All Together In The Nfinity UPS System Itlooks and works like no UPS we ve offered before Nfinity s unique frame design houses all of the modular system components It contains bays to hold the power modules battery modules and system control modules The modules offer hotswap capability making it easy to add capacity or replace modules The Nfinity class of power protection offers a variety of advantages Nfinitys modular design was devised to provide easy scalability to users as their power demands grow By simply installing additional power or battery modules you can expand your current system extend yourbackup runtime or add redundancy Scalability Provides The Flexibility To expand Nfinity s patent pending frame design provides the user with the maximum adaptability that is demanded in today s ever changing network environment Because Nfinity is scalable for redundancy power capacity or battery run time you have greater flexibility in how you can use the system Configurations can be cost effectively upgraded without re investing in a new system or installation
Download Pdf Manuals
Related Search
Related Contents
CUBE HOPPER MKII Istruzioni - International Dental Supply Lipsync documentation 9200, 9400 SERIES 220-240V Sterling Plumbing Frameless Pivot Shower Door 6305 Series User's Manual Yamaha DM2000 Product Sheet : Free Download, Borrow, and Streaming : Internet Archive 2010.10月号 兵ト協ニュース291 T'nB VINTAGE Precise 760 - The Cool Tool Televes DAT BOSS 790 UHF Copyright © All rights reserved.