Eaton Pulsar MX 5000 RT Netpack

image

Contents

1. 5 mm wide compatible with 800 1000 mm deep rack 250 kg Rack 16U x 444 5 mm wide compatible with 800 1000 mm deep rack MX EXB battery unit tower rack 444 5 mm high x 130 6 mm wide x 650 mm deep 3U x 444 5 mm wide 70 kg dimensions same as MX Frame 230 kg for 15 kVA 290 kg for 20 kVA Pulsar MX ModularEasy paralleling kit dimensions same as EXB battery unit 10 kg eee ree Oars Sere aoe 1 Available from November 2006 2 2 Pulsar MXs can be paralleled using ModularEasy 3 At 70 load 4 4 IEC C13 10A 2 m long cables for use with retention clips 8 cables for use with Pulsar MX Frame 5 Frequency conversion for non paralleled units only 6 Economy mode 91 in normal mode 7 At 70 nominal rating with power factor 0 7 typical values after 3 charge discharge cycles with 3 5 year old batteries Weekly battery test without interrupting the load daily or monthly if required EXB compatible with 0 8 power factor loads 8 With Pulsar MX Frame EXB 4 battery units 9 With Pulsar MX Frame EXB 8 battery units 10 Solution Pac CD ROM supplied as standard 11 Applicable to US models 12 50 dbA above 5 kVA 13 Depending on the country see www mgeups com service 14 68 513 68 526 empty Pulsar MX Frame 3 x 68 524 3 x 68 523 15 68 514 68 526 empty Pulsar MX Frame 4 x 68 524 4 x 68 523 Part numbers Pulsar MX 4000 RT Pulsar MX RT Tower or rack mounting standard backup time 68 501 68 504 Pulsar MX RT Netpack standard bac
2. 50 V 50 60 Hz autoselect frequency converter as standard lt 2 97 10 minutes 45 80 120 minutes 35 60 95 minutes VFI SS 113 on line double conversion with power factor correction convection cooled static bypass switch L N terminals up to 6 mm 200 208 220 230 240 250 V 200 208 220 230 240 250 V L N or 380 400 415 V 3P N 120 280 V L N or 3P N terminals up to 35 mm Separate or common AC normal and AC bypass 120 280 V L N 250 465 V 3P N 40 70 Hz lt 7 terminals 16 IEC C13 10A 4 IEC C19 16A 2 groups 4 IEC C13 10A per group 8 minutes 20 minutes 35 minutes lots l minislot or 2 minislots Frame compatible with Minislot NMC NMC ModBus JBus MC Contacts Serial Ports Remote Power off RJ11 5 output contacts DB9 setup using Solution Pac USB and DB9 serial ports Operating conditions standards and approvals Performance safety EMC surge protection perating temperature noise approvals guarantee EXB module detection RJ45 paralleling DB 15 IEC EN 62 040 3 IEC EN 62 040 1 1 IEC EN 62 040 2 class A class B as option 4 kV IEC 61 643 UL 1778 and CSA 22 2 0 C to 40 C continuous 45 dbA UL T V GS mark CB C Tick CE IEC 61 931 one year Pulsar MX RT standard backup tower 444 5 mm high x 130 6 mm wide x 735 mm deep 57 kg Tower 690 mm high 795 mm casters x 444 5 mm wide x 735 mm deep Pulsar MX RT standard backup rack 3U x 444
3. kup time 68 502 68 505 NMC rack kit Pulsar MX 5000 RT Pulsar MX 15000 Frame 16U Pulsar MX 20000 Frame 16U 68 513 68 5140 with rack kit with rack kit casters NMC card casters NMC card Pulsar MX EXB RT battery extension module 68515 68 527 Pulsar MX Frame EXB empty to be fitted with 4 or 8 Battery sub modules Pulsar MX ModularEasy paralleling kit 2 Pulsar MX 68 520 MX EXB RT Rack Kit rail kit for 19 rack mounting 68 002 IEC 32 A kit 2 X 2 m long cables male to 68 525 hardwired and female to hardwired Pulsar MX Battery Power electronics sub module 68 524 68 522 68 524 68 523 MGE UPS SYSTEMS Headquarters 140 avenue Jean Kuntzmann ZIRST Montbonnot Saint Martin 38334 Saint lsmier Cedex France Tel 33 0 4 76 18 30 00 PULMX515UK 02 06 68 524 68 523 E UNINTERRUPTIBLE POWER PROVIDER HO 4 C CE kA CENELEC Due to developments in technical standards and the equipment described in this document we cannot be held liable for compliance with the characteristics indicated by the images and text unless they are confirmed by us All the brand names referred to in this document are protected by copyright Publication MGE UPS SYSTEMS February 2006 Design and rewriting 3c evolution com Integration Pamplemousse 33 4 79 37 87 66 Translation TTP 33 4 78 66 47 99
4. mote reboot of the equipment connected sequential start up or load shedding while operating from battery to maintain the power to critical loads b Pulsar MX Frame is compatible with three phase or single phase supplies Backup time 10 mins up to 2 hours by adding 3U battery extension modules Paralleling 2 Pulsar MXs using ModularEasy for 2N or N 1 redundancy gt Pulsar MX Frame is a modular to be upgraded the Pulsar MX 4000 and 5000 can be paralleled to provide 8 kVA or 10 kVA using the ModularEasy kit without extra cost on the initial purchase Can be built in to high density racks system with 5 kVA sub modules paralleled to provide up to 20 kVA or 15 kVA with redundancy Pulsar MX Frame 15 and 20 kVA tower and rack mounting 16U modular system with 5 kVA sub modules F Redundancy for highly critical applications DER paw Q at O g amp v N A Q Q Pa W KA gt M E D ui UPS SYSTEMS i I O O O Communications Solution Pac 2 suite supplied for remote Supervision MGE s Enterprise Power Manager for supervision via Ethernet and Teleservice EPM is compatible with standard network management systems Tivoli CA unicenter HP Openview Compatible with Network Shutdown Module for monitoring a number of UPSs and shutting down the servers on the network MGE PowerServices 1 year guarantee including batteries A
5. ssociated services Extended guarantee Commissioning Teleservice in band and out of band b Personalised maintenance contracts 1 Depending on the country see www mgeups com services Specifications Pulsar MX RT Rating KVA kW Paralleling Single phase UPS Pulsar MX 8 IEC 10A outlet sockets Retention clips 2 IEC 16A outlet sockets Output circuit protection 1 minislot for NMC Modbus JBus or MC Contacts Serial card RJ11 remote power off RJ45 EXB battery module detection DB9 with 5 output contacts DB 9 serial and USB ports Setup and supervision DB 15 paralleling Output Input EXB battery extension module power connector 4kVA 5 kVA 15 kVA 20 kVA 4 kVA 3 6 kW 5 kVA 4 5 kW 15 kVA 13 5 kW 20 kVA 18 kW Maximum rating 8kVA 4kVA 4 kVA redundancy 10 kVA 5 kVA 5 kVA redundancy 15 kVA 10 kVA 5 kVA redundancy 20 kVA 15 kVA 5 kVA redundancy redundancy 5 kVA 2 x 5 kVA redundancy 10 kVA 2 x 5 kVA redundancy echnology Number of phases input connections ominal voltage oltage range without using battery nput frequency range THDI Output connections emotely controlled Powershare sockets Output voltage and frequency THDU efficiency ackup time Pulsar MX standard backup time ulsar MX EXB MX 2 EXB MX 3 EXB ommunications terminals 8 IEC C13 10A 2 IEC C19 16A 2 groups 2 IEC C13 10A per group 200 208 230 240 2
6. www mgeups com Entreprise Networks Telecom Process and infrastructures Single phase UPS Pulsar MX 4 5 8 10 15 20 kVA Can be used for 20 to 110 servers ideal for departmental networks servers and workstations High performance UPS upgradeable from 4 kVA to 20 kVA Continuous power supply gt Two front access hot swappables sub modules power and battery for maintenance without load interruption b Automatic battery test test period can be set Internal bypass built in to supply the load even if the UPS fails gt Large input voltage and frequency ranges to avoid using the batteries unnecessarily Pulsar MX 10 minutes backup tower rack mounting 3U mimic LCD display The power level can be upgraded simply and without interruption for the existing loads as the number of loads supplied is increased Minimum total cost of ownership TCO gt More power with an output power factor of 0 9 D When the power supply needs Pulsar MX has 2 sub modules power electronics and battery which are hot swappable Flexible Can be used as a free standing tower unit or 19 rack mounted only 3U for Pulsar MX 4000 and 5000 16U for Pulsar MX Frame LCD multilingual display with mimic and LEDs for rapid view of the UPS Status diagnostics and event log Outputs IEC 10A and 16A outlet sockets and hardwired outputs Built in Powershare system for re