Home

HP ProCurve 6410-6XG cl

image

Contents

1. km using engineered link ProCurve 10 GbE X2 CX4 Transceiver 0 5 m to 15 m using CX4 cable Up to 300 m using J8439A media converter using MMF 42 93 x 44 2 x 4 32 cm 16 9 x 17 4 x 1 7 in 1U height 6 1 kg 13 56 Ib Motorola PowerPC MPC8245 266 MHz 128 MB 128 MB 4 MB 16 MB Mounts in an ElA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only lt 11 7 us LIFO 64 byte packets Up to 119 million pps 64 byte packets 160 Gbps 16 000 entries 0 C to 55 C 32 F to 131 F 40 C 104 F when used with SR LR ER optics 15 to 95 at 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 at 65 C 149 F non condensing Up to 4 6 km 15 000 ft Power 55 dB lt 25 C 77 F DIN 45635 T 19 per ISO 7779 404 kJ hr 383 BTU hr including use of optional cl modules with optics 100 127 VAC 200 240 VAC 3 A 1 5 A 112 W 50 60 Hz CSA 22 2 No 60950 EN 60950 IEC 60950 UL 60950 FCC Class A EN 55022 CISPR 22 Class A VCCI Class A EN 55024 CISPR 24 IEC 61000 4 2 4 kV CD 8 kV AD IEC 61000 4 3 3V m IEC 61000 4 4 1 0 kV power line 0 5 kV signal line IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 6 3V IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 lt 11 7 us LIFO 64 byte packets Up to 119 million pps 6
2. the browser based management GUI in the switch IEEE 802 1X and RADIUS network login control port based access for authentication and accountability Port security allows access only to specified MAC addresses which can be learned or specified by the administrator Web based authentication similar to IEEE 802 1X provides a browser based environment to authenticate clients that do not support the IEEE 802 1X supplicant ProCurve Switch 6400cl Series Features and benefits continued e Secure FTP allows secure file transfer to from the switch protects against unwanted file downloads or unauthorized copying of switch configuration file Secure access to manage the 6400cl series all access methods CLI GUI or MIB are securely encrypted through SSHv2 SSL and or SNMPv3 Convergence IP multicast snooping and data driven IGMP automatically prevents flooding of IP multicast traffic Quality of Service QoS e Rate limiting per port ingress enforced maximums e Layer 4 prioritization enables prioritization based on TCP UDP ports Traffic prioritization IEEE 802 1p allows real time traffic classification into 8 priority levels mapped to 4 queues Class of Service CoS sets IEEE 802 1p priority tag based on IP address IP Type of Service ToS L3 protocol TCP UDP port number source port and DiffServ Manageability sFlow RFC 3176 wire speed traffic accounting and monitoring e RMON an
3. 4 byte packets 160 Gbps 16 000 entries 0 C to 55 C 32 F to 131 F 40 C 104 F when used with SR LR ER optics 15 to 95 at 40 C 104 F non condensing 40 C to 70 C 40 F to 158 F 15 to 95 at 65 C 149 F non condensing Up to 4 6 km 15 000 ft Power 55 dB lt 25 C 77 F DIN 45635 T 19 per ISO 7779 404 kJ hr 383 BTU hr including use of optional cl modules with optics 100 127 VAC 200 240 VAC 3 A 1 5 A 120 W 50 60 Hz CSA 22 2 No 60950 EN 60950 IEC 60950 UL 60950 FCC Class A EN 55022 CISPR 22 Class A VCCI Class A EN 55024 CISPR 24 EC 61000 4 2 4 kV CD 8 kV AD EC 61000 4 3 3V m EC 61000 4 4 1 0 kV power line 0 5 kV signal line EC 61000 4 5 1 kV 2 kV AC EC 61000 4 6 3V EC 61000 4 8 1A m 50 or 60 Hz EC 61000 4 11 gt 95 reduction 0 5 period 30 reduction 25 periods EN 61000 3 2 IEC 61000 3 2 EN 61000 3 3 IEC 61000 3 3 ProCurve Switch 6400cl Series Specifications continued Management Standards and protocols applies to both products ProCurve Switch 6400cl J8433A serial RS 232C Device management HTML and telnet management General protocols EEE 802 1D MAC Bridges EEE 802 1p Priority EEE 802 1Q VLANs EEE 802 1s Multiple Spanning Trees EEE 802 1v VLAN Classification by Protocol and Port EEE 802 1w Rapid Reconfiguration of Spanning Tree EEE 802 3ad Link Aggregation Control Protocol LACP EEE 802 3ae 10 Gigabit Eth
4. d XRMON provide advanced monitoring and reporting capabilities for statistics history alarms and events e Stacking capability single IP address management for a virtual stack of up to 16 switches including the 3400cl series Industry leading warranty Lifetime warranty for as long as you own the product with next business day advance replacement available in most countries Services ProCurve Switch 6400cl and ProCurve Switch 6410cl 3 year 4 hour onsite 13x5 coverage for hardware UA438E 3 year 4 hour onsite 24x7 coverage for hardware UA439E 3 year 24x7 software phone support software updates UF791E Installation with minimum configuration system based pricing U4826E Installation with HP provided configuration system based pricing U4830E Installation with HP provided configuration system based pricing UA440E Check www procurve eu services for part numbers and service level descriptions For details about services and response times in your area please contact your local HP sales office ProCurve Switch 6400cl Series Specifications Ports Cabling Physical characteristics Dimensions D x W x H Weight Memory and processor Fabric processor type and speed SDRAM Flash ROM Packet buffer size Flash Mounting Performance Latency Throughput Routing Switching capacity Address table size Environment Operating temperature Operating relative hu
5. e Shell ProCurve Switch 6400cl Series Modules Accessories ProCurve Switch cl 10 GbE Media Flex Module J8435A ProCurve Switch cl 10 GbE CX4 Copper Module 18434A ProCurve 10 GbE X2 CX4 Transceiver J8440B ProCurve 10 GbE CX4 Media Converter J8439A ProCurve 10 GbE X2 SC SR Optic J8436A ProCurve 10 GbE X2 SC LR Optic J8437A ProCurve 10 GbE X2 SC ER Optic J8438A ProCurve 600 Redundant External Power Supply J8168A For more information To learn more about ProCurve Networking please visit www procurve eu 2007 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein 4AA1 5963 EEE Fall 2007 ProCurve Networking by HP
6. ernet EEE 802 3ak 1OGBASE CX4 EEE 802 3x Flow Control RFC 768 UDP RFC 783 TFTP Protocol revision 2 RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 854 TELNET RFC 951 BOOTP RFC 1058 RIP v1 RFC 1542 BOOTP Extensions RFC 2030 Simple Network Time Protocol SNTP v4 RFC 2131 DHCP RFC 2453 RIPv2 RFC 3046 DHCP Relay Agent Information Option ProCurve Switch 6410cl J8474A IP multicast RFC 3376 IGMPv3 MIBs RFC 1213 MIB II RFC 1493 Bridge MIB RFC 1724 RIPv2 MIB RFC 1850 OSPF v2 MIB RFC 2096 IP Forwarding Table MIB RFC 2618 RADIUS Client MIB RFC 2620 RADIUS Accounting MIB RFC 2665 Ethernet Like MIB RFC 2668 802 3 MAU MIB RFC 2674 802 1p and IEEE 802 1Q Bridge MIB RFC 2863 The Interfaces Group MIB Network management EEE 802 1AB Link Layer Discovery Protocol LLDP RFC 2819 Four groups of RMON 1 statistics 2 history 3 alarm and 9 events RFC 3164 BSD syslog Protocol RFC 3176 sFlow SNMPv1 v2c v3 XRMON ProCurve Manager Plus ProCurve Manager included command line interface Web browser configuration menu out of band management OSPF RFC 2328 OSPFv2 QoS Cos RFC 2474 DiffServ Precedence including 8 queues port RFC 2597 DiffServ Assured Forwarding AF RFC 2598 DiffServ Expedited Forwarding EF Security IEEE 802 1X Port Based Network Access Control RFC 1492 TACACS RFC 2138 RADIUS Authentication RFC 2866 RADIUS Accounting Secure Sockets Layer SSL SSHv1 SSHv2 Secur
7. midity Non operating Storage temperature Non operating Storage relative humidity Altitude Acoustic Electrical characteristics Maximum heat dissipation Voltage Current Power consumption Frequency Safety Emissions Immunity EN ESD Radiated EFT Burst Surge Conducted Power frequency magnetic field Voltage dips and interruptions Harmonics Flicker ProCurve Switch 6400cl J8433A 6 CX4 10 GbE ports IEEE 802 3ak Type 10Gbase CX4 Duplex full only 1 RS 232C DB 9 console port Supports a maximum of 8 10 GbE ports CX4 ports Maximum distance 0 5 m to 15 m using CX4 cable Up to 300 m using J8439A media converter using MMF 42 93 x 44 2 x 4 32 cm 16 9 x 17 4 x 1 7 in 1U height 5 60 kg 12 35 Ib Motorola PowerPC MPC8245 266 MHz 128 MB 128 MB 4MB 16 MB ProCurve Switch 6410cl J8474A 6 open 10 GbE X2 transceiver slots Duplex full only 1 RS 232C DB 9 console port Supports a maximum of 8 10 GbE ports X2 transceiver slots ProCurve 10 GbE X2 SC LR Optic Maximum distance 9 125 um single mode cable 2 10 km ProCurve 10 GbE X2 SC SR Optic Maximum distance 62 5 um multimode cable 160 MHz km 2 26 meters 62 5 um multimode cable 200 MHz km 2 33 meters 50 um multimode cable 400 MHz km 2 66 meters 50 um multimode cable 500 MHz km 2 82 meters 50 um multimode cable 2000 MHz km 2 300 meters ProCurve 10 GbE X2 SC ER Optic Maximum distance 30 km 40
8. oe Ses by HP ProCurve Switch 6400cl Series The ProCurve Switch 6400cl series consists of 6 port 10 GbE stackables with optional 10 GbE add on modules Loaded with full Layer 3 features the 6400cl series switches offer low cost 10 GbE for high performance aggregation of clusters of Gigabit switches Ideal for consolidating multiple wiring closets the 6400cl series offers the highest bandwidth on the market today for Gigabit The ProCurve Switch 6400cl series also provides fiber flexibility to connect remote campuses up to 40 km away ProCurve Switch 6400cl J8433A ProCurve Switch 6410cl J8474A ProCurve Switch 6400cl Series Features and benefits Performance 160 Gbps backplane with 119 mpps unprecedented bandwidth for low latency throughput Selectable queuing configurations increase performance by selecting the queuing configuration that best meets the requirements of network applications Jumbo frames on Gigabit and 10 Gigabit ports allow high performance remote backup and disaster recovery services Resiliency and high availability Router redundancy XRRP allows groups of two routers to dynamically back each other up to create highly available routed environments e IEEE 802 3ad Link Aggregation Control Protocol LACP and ProCurve trunking support up to 4 trunks each with up to 4 links ports per trunk trunking across modules is supported IEEE 802 1s Multiple Spanning Tree
9. provides high link availability in multiple VLAN environments by allowing multiple spanning trees IEEE 802 1w Rapid Convergence Spanning Tree Protocol increases network uptime through faster recovery from failed links e Optional redundant power supply provides uninterrupted power provided by ProCurve 600 RPS EPS Layer 2 switching e ProCurve switch meshing dynamically load balances across multiple active redundant links to increase available aggregate bandwidth e VLAN support and tagging supports the IEEE 802 10 4 096 VLAN IDs and 256 VLANs simultaneously e GARP VLAN Registration Protocol allows automatic learning and dynamic assignment of VLANs IEEE 802 1v protocol VLANs isolate select non IPv4 protocols automatically into their own VLANs Layer 3 routing Layer 3 IP routing provides routing of IP at media speed supports static routes RIP RIPv2 and OSPF Security e Access control lists ACLs provide IP Layer 3 filtering based on source destination IP address subnet and source destination TCP UDP port number Source port filtering allows only specified ports to communicate with each other TACACS eases switch management security administration by using a password authentication server Secure Shell SSHv2 encrypts all transmitted data for secure remote command line interface CLI access over IP networks Secure Sockets Layer SSL encrypts all HTTP traffic allowing secure access to