Home
APC SmartSlot Expansion Chassis
Contents
1. Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio or TV technician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to find answers to frequently asked questions FAQs to access documents in the APC Knowledge Base and to submit customer support requests Wwww apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information Www apc com support Global support with FAQs knowledge base and e support e Contact an APC Customer Support center by telephone or e mail Regional centers APC Headquarters en 1 800 800 4272 toll free Latin America 1 401 789 5735 United States Europe Middle East Africa 353 91 702020 Ireland Japan 03 5434 2021 Guidance 3 Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from wh
2. Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction Warranty and Service 7 Life Support Policy General policy Examples of life support devices American Power Conversion APC does not recommend the use of any of its products in the following situations e In life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness e In direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances The term life support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubato
3. to the original purchaser To obtain support for problems with your Expansion Chassis 1 2 Note the serial number and date of purchase Contact Customer Support at a phone number on the back cover of this document A technician will try to help you solve the problem by phone If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number and daytime phone num ber a copy of the sales receipt and a check as payment if applicable Mark the RMA number clearly on the outside of the shipping carton Ship by insured prepaid carrier to the address provided by the Customer Support technician Warranty and Service Warranty limitations Except as provided herein APC makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage
4. Expansion Chassis AP9600 Installation Manual Content Product Description lt lt lt Installation 22 42 id di hala Operation L iddasi dee aoi ande Specifications coo ii eae ee Warranty and Service oooooooooooomoo Life Support Policy Product Description Overview The APC Expansion Chassis allows the use of APC management cards with APC UPSs that are not equipped with a card slot but do have an advanced computer interface port The Expansion Chassis can also be used with UPSs that have a card slot to provide additional management cards as shown below Card slot Cable marked UPS for connecting to the computer interface port of the UPS Power connector for an optional power adapter UPS Monitoring port that duplicates the functions of the UPS s computer interface port Status indicator Product Description 1 Installation Compatibility The Expansion Chassis can be used with any APC device equipped with an advanced computer interface port This includes Smart UPS and Symmetra products and any other accessories that duplicate the functions of a UPS computer interface port such as Share UPS Installation 1 Connect the cable labeled UPS to the computer inter procedure face port of the UPS 2 Connect the second Expansion Chassis with the cable labeled UPS to the UPS monitoring port Two Expansion Chassis can be co
5. nnected together to provide up to three card slots including the one in the UPS Do not connect more than two Expansion Chassis to any UPS Note 2 Installation Power adapter The optional power adapter AP9505 not supplied is for 100 120 V systems only if required The power adapter is required under the following conditions e Smart UPS Serial number prior to 9405 Serial number starting with the letter W All Smart UPS 250 models e Matrix UPS When remote turn on of the UPS is required If you need to obtain a power adapter contact APC Customer Service at a telephone number on the back cover if needed Decide whether to connect the AC adapter into a wall outlet or a protected UPS Outlet If the device needs to function during a power outage connect the power adapter into one of the AC outlets on the UPS If remote turn on operation is Note required connect the power adapter into a wall outlet See Operation on page 4 before install ing any UPS accessory in the Expansion Chassis Installation 3 Operation Checking operation Status LED 1 After installation of the Expansion Chassis and before installing a UPS accessory confirm that the indicator light is dimly lit 2 After installation of a UPS accessory confirm that the indi cator light is brightly lit 3 Confirm the operation of the UPS accessory The Expansion Chassis status LED indicates the following sta
6. om you purchased your APC product for information on how to obtain local customer support Entire contents copyright 2001 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC Smart UPS Symmetra Share UPS and the APC logo are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 0124A 10 2001
7. rs ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with this modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care Life Support Policy Radio Frequency Interference Changes or modifications to this unit not expressly A approved by the party responsible for compliance could void the user s authority to operate this Warning equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on try to correct the interference by one or more of the following measures
8. tes State Indication Bright The accessory is installed and the Expansion Chassis has power Dim The accessory is not installed and the Expansion Chassis has power Off The Expansion Chassis has no power Operation Specifications Product specification Item Specification Electrical Operating voltage 18 30 V 30 mA exclusive of installed Operating current draw accessory Physical 2 75 x 5 x 5 25 in Size H x W x D 7 x 12 7 x 13 3 cm 1 5 lb Weight 0 7 kg 2 Ib Shipping weight 0 9 kg Environmental 0 to 10 000 ft 0 to 50 000 ft Operating elevation storage 0 to 3000 m 0 to 15 000 m Operating temperature 5 to 45 C 225 to 65 C storage 23 to 113 F 13 to 149 F Approvals FCC Class B DoC Class B EMC verification EN55022 Class B VCCI AS NZS 3548 Electromagnetic immunity EN50024 verified Specifications 5 Warranty and Service Limited warranty Obtaining service APC warrants the Expansion Chassis to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at 1ts own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only