SECO-LARM SK-910R4Q

image

Contents

1. Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com
2. 60 seconds when a compatible transmitter button is pressed To program the output timer flip the DIP switches in the timer programming switch according to Table 1 Note The SK 910R4Q has only one timer If more than one relay is set to timed output each relay turns ON for the Same amount of time CH 3 Mode Switch CH 4 Mode Switch Table 1 Timer Programming CH 2 Mode Switch Programming Mode Switch Switch Setting CH 1 Mode Switch Timer Programming Switch OO OOO sve is On off off MODE SWITCH er 2 Off On Off 3 Off Off On Za On Off On Fig 1 60 On On On Default Setting lf optional antenna is used LP3 must be cut and the antenna Slot on the receiver case must be chip off to accomodate the extended range antenna wire see Fig 1 Power Input 11 24VAC VDC Channel 1 Channel 2 Channel 3 Channel Mode Switch Operation one per channel e Learn mode Press and hold the switch for three seconds or more e Clear memory Press and hold the switch for three seconds or more then when the LED starts flashing press again for three seconds to delete all previously learned codes e Reset latched output If this channel was programmed for latch output once the relay is turned on with a transmitter button press the mode switch of that channel once to turn the relay OFF e Memory Dis
3. the antenna wire as long and straight as possible If the receiver receives interference from local RF activity e g an airport or military base the antenna wire can be folded DO NOT CUT THE ANTENNA WIRE All models work on 11 24VAC VDC except for the low voltage versions This manual covers only four channel receivers For information on our one and two channel receivers please contact SECO LARM Note Model numbers that end with Q indicate RoHS compliant products Code Learning a New Transmitter Button Each receiver channel can learn the codes of up to 15 different transmitter buttons on a first in first out basis Below is the procedure for code learning a new transmitter button The same procedure applies to all the receiver s four channels 1 Press the mode switch of the desired channel to be programmed for 3 seconds or more The channel s red LED will Start to flash quickly to indicate that it is in the learning mode 2 While the red LED is quickly flashing press the button of the transmitter to be learned once The red LED will flash once to indicate a successful learning of that button s code NOTE a The mode switches can be found at the rear of the receiver s case See Fig 1 The switch marked 1 represents the mode switch for channel 1 switch 2 is the mode switch for channel 2 and so on b The channel s red LED will flash a maximum of 15 seconds If no transmitter button is pressed during this time the r
4. 91ERSWQ eee Typical Applications Positive Output Negative Output Positive Power Source Negative Power Source Positive Power Output Negative Power Output Power for SK 910R4Q Power for SK 910R4Q 11 24 VAC VDC power input 24VAC output driving a motor 11 24 VAC VDC power input 24VDC output driving a motor 24VAC 1 Input 24VDC 1 Input C 4 11 24 VAC VDC Power O a 11 24 VAC VDC Power for SK 910R4Q for SK 910R4Q 12VDC power input 12VDC positive output Typical N C application access control 12VDC power input 12VDC positive output E 941SA 1200 Electromagnetic Lock 12VDC Power for SK 910R40 12VDC Power for SK 910R40 General Specifications Operating Frequency 315MHz SK 910R4Q 433 92MHz SK 910R4 4Q Memory Capacity 15 transmitter button codes per channel 60 per receiver Operating Voltage 11VDC 24VDC or 11VAC 24VAC Operating Current 8 mA 12VDC standby 30mA channel 12VDC activated Relay Contact Rating Form C type 10A 24VDC or 120VAC per channel Connectors Screw Terminals with N 0 N C and COM per channel Dimensions 53x39x11 135 100 27 5 mm Compatible Transmitters 315MHz 433 92MHz Fxed Cade 68 bilion codes CODEBUMP 18 quintillion 1 8 x 10 codes WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of
5. Installation Manual ye ENFORCER 4 gt gt SK 910R4Q SK 910R4 4Q Four Channel RF Receivers Operates on 11 24VAC VDC RwHSs Up to 500 ft range Models Available See SECO LARM for details SK 9 TORQ 000 One channel receiver 31 5MHz SK 910ORLQ Low voltage one channel receiver 31 5MHz SK 9 1ORVQ Low voltage one channel receiver Transistor ground output 31 5MHz SK 910R2Q Two channel receiver 31 5MHz SK 910R 4 Q One channel receiver 433 92MHz SK 91ORL 4Q Low voltage one channel receiver 433 92MHz SK 910R2 4Q Two channel receiver 433 92MHz SK 91ORV 4Q Low voltage one channel receiver Transistor ground output 433 92MHz Introduction The SK 910R4Q is a four channel receiver which meets the growing demand for a multi channel receiver with multiple and independently controlled output modes This RF receiver is compatible with both code hopping and fixed code transmitters see page 4 of this manual for a list of compatible transmitters The receiver can be used to control a variety of home automation devices such as garage door openers lights motorized gates lifts or other devices Installation Notes 1 Mount out of sight in a location where it is not surrounded by metal and where it is not exposed to the weather or to moisture Metal will block the RF signal resulting in a reduced range 2 For best range pull
6. eceiver will exit the code learning mode and the red LED will turn off c If the code being learned has already been learned the red LED for the channel which learned the code will turn steady ON and the code will not be learned a second time d Each channel can learn the codes of a maximum of 15 transmitter buttons If you attempt to learn a sixteenth button the earliest code learned will be deleted Channel Memory Clear To clear all codes in the channel s memory enter the channel learning mode first then press the channel mode switch for 3 or more seconds again The LED flashes twice to indicate that all codes associated with that channel are now deleted Channel Memory Display To see how many codes have been learned in a channel press that channel s mode switch once The number of codes Stored in the channel s memory is equal to the number of LED flashes Programming Each Channel Relay Output Mode Each receiver s channel can be programmed for one of four different modes and each individual channel may operate at a different output mode depending on the user s application Applications are as follows e Timed Output Press the transmitter button once The timed output relay will activate from 1 60 seconds depending on how long the timed output duration is set Factory default is 1 second timed output e Toggle Output Works much like a toggle switch to turn a device ON amp OFF alternately Press the transmitter b
7. play Press and release the mode switch to show the number of codes stored The LED will flash a number of times corresponding to the number of codes stored LED Indication one per channel Steady ON Senses signal from a transmitter button or indicates a transmitter button s code already exists in the receiver s memory during code learning Fast flash In the code learning mode or channel memory display mode or during the programming channel output mode One flash A transmitter button s code was learned or the relay is in time output mode Two flashes All previously learned transmitter button codes were deleted or the relay is in toggle output mode Three flashes Latched output Four flashes Validity output 0 15 flashes In the normal operation mode pressing the channel mode switch 1 4 once will display the number of codes learned Extended Range Antennas Two antennas are available to extend the range of the SK 910R4Q receiver SK 91 ERSWQ Extends RF receiver range up to 800 feet open air with existing remotes SK 91ERSDQ Extends RF receiver range up to 1 200 feet open air with existing remotes These antennas come with a 9 cable which easily plugs into the 3 pin antenna port located on the RF receiver Note a If an extended range antenna is used the LP3 on the receiver PC board must be cut b Actual antenna range will vary greatly depending on the operating environment ill SK
8. sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2006 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM FILE DT DTP MtiSk9104Q_06A pmd SECO LARM U S A Inc ORDER PART 762 100 1
9. utton once and the relay turns on Press a compatible transmitter button again and the relay turns off e Latch Output Press the transmitter button once and the relay turns on and stays on The relay will remain on until the appropriate channel mode switch is pressed once to reset regardless of whether a compatible transmitter button is pressed again or not e Validity Output The channel will turn the relay ON for as long as the transmitter button is pressed Note Care must be taken when using validity output Due to possible interference or drops in transmitter battery power while the transmitter button is continuously pressed even for short periods of time the receiver may lose the transmitter s signal and turn the relay off To program each channel output mode press the programming mode switch once switch 5 see Fig 1 Each channel s red LED will flash a number of times equal to the output mode that it is in Below are the channel output LED flash indicators 1 One flash Timed Output 3 Three flashes Latch Output 2 Two flashes Toggle Output 4 Four flashes Validity Output Press the mode switch of the desired channel to be programmed a number of times until the required output is achieved The programming procedure for all four channels is the same To exit programming press programming mode switch again Setting the Timed Output Timer When a relay output is set to timed output it turns ON for 1 to