1. Bagless Upright Powermax VRS24B VRS25R Get Cleaning What s your serial number L f the machine AAA ATT Machine Overview Handle Dirt container lid HEPA filter Dirt container Lower hose inspection tube On off switch Brushbar height adjuster Vacuum head Wheel Cord clip Dirt container release button Crevice tool stored in extension tube Extension tube Hose clip Hose Power cord Hose connector Lower cord wrap with quick release Unit recline pedal Two 2 short screws Two 2 long screws FLBESA EEE EEE TurboTool Some models only PLEASE NOTE Some parts may vary according to model Please check inside flap of the box for more details WARNING This cleaner has a constantly rotating brushbar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this cleaner on lino and hard flooring Vax cannot be held responsible for damage to these surfaces if the customer fails to take notice of this recommendation General Safety Information FOR HOUSEHOLD USE ONLY When using the vacuum cleaner basic safety precautions should always be observed including the following 1 Only use the vacuum cleaner indoors on dry surfaces Do not han
2. TOOLS REQUIRED Phillips screwdriver WARNING To reduce the risk of electric shock the power cord must be disconnected before removing the dirt container HEPA filter changing the filters or performing maintenance troubleshooting checks Occasionally the power nozzle drive belt will require changing the frequency will depend upon the amount of vacuum use Turn vacuum off and unplug from power supply Press unit recline pedal and lay vacuum cleaner on a flat level surface Using a crosshead screwdriver remove the five 5 screws on the underside of the cleaner Pull down the smaller wheel flap on the underside and remove the remaining screw inside the black tube Remove the brushbar height adjuster knob from the top of the floor head cover Remove the floor head cover Lift the right side of the brushbar and lift the left hand side and remove the brushbar from the ifting from the rear of the machine power head Remove the worn or broken belt from the motor drive shaft Carefully remove any belt residue that may exist in he belt area before replacing with a new belt Loop the new belt first over the motor drive shaft and then over he agitator pulley Insert the right side of the brushbar in first by placing the end cap down in the slot and then so the same with the left side Press firmly to make sure that each end is completely inserted Check to make sure that the belt is centred
3. container release button container and turning and pulling out and lift away from the anti clockwise vacuum cleaner Y Firmly tap clean the HEPA filter until no more dust is observed falling out The HEPA filter may be washed by running it under the tap We recommend washing it once a month or when suction appears reduced Always allow to air dry for 24 hours before replacing into the vacuum PLEASE NOTE The white material in the HEPA filter will discolour over time This is NORMAL and will NOT affect the performance of the filter WARNING Always empty the dirt container and clean the HEPA filter before each use and during prolonged usage Never over fill the dirt container remove dirt and clean the HEPA filter each time the dirt container is emptied during prolonged usage or risk motor damage Cleaning the HEPA pre motor filter Underneath the dirt container is a pre motor filter If found to be defective please replace WARNING To reduce the risk of electric shock the power cord must be disconnected before removing the dirt container HEPA filter changing the filters or performing maintenance troubleshooting checks The dirt container can be washed in lukewarm water max 40 C Do not use strong detergents Ensure that the dirt container is fully dry before putting back on the vacuum cleaner Do not wash in dishwasher Maintenance Keep your Vax as good as new Cleaning and changing the belt
4. ORTANT Washing recommends that they should be checked and cleaned periodically ilters maintains vacuum performance Vax depending on the level of use Make sure all filters are completely dry before inserting back into the vacuum cleaner IMPORTANT The motor is equipped with a thermal cut out If for any reason the unit should overheat the thermostat will automatically turn the unit off Should this occur unplug the vacuum cleaner from the electrical socket and turn off the switch Remove dirt container and empty Clean filters Allow the unit to cool for approximately one 1 hour To re start plug into an electrical socket and switch back on This vacuum cleaner is intended for household use only and NOT for commercial or industrial use PLEASE KEEP INSTRUCTIONS FOR FURTHER USE Operation Assembling your vacuum cleaner IMPORTANT Always remove the power plug from the electrical outlet before assemb ing or removing accessories Firmly push the back panel Ensure it is fully located Slide the handle into onto the base assembly before inserting the two place onto the top of the short screws back panel Secure the top handle to the back panel by inserting the two long screws nsert the bottom of the dirt Align the tabs on the Push and turn the hose container to align with the tab lower hose inspection clockw
5. Why is there a red light on the nozzle e The brushbar may be jammed Refer to the maintenance section for how to reset the brushbar page 7 e If the red light still shows we re here to help Simply call us on 0844 412 8455 we re here if you need us Instead of taking me back to the shop simply visit vax co uk support vaxireland ie or call UK 0844 412 8455 ROI 1 800 928 308 This does not affect your statutory rights Other Information UK Service amp Help Any queries or concerns about using your Vax simply visit vax co uk support vaxireland ie or call the Vax Careline Calls are charged at the UK local rate Please make a note of the serial number and model number of the vacuum cleaner before calling Vax Careline UK 0844 412 8455 ROI 1 800 928 308 Monday Friday 8 30am to 6 30pm Saturday Sunday 9 00am to 5 00pm Consumables o purchase spares and accessories please visit vax co uk The use of genuine vax spare parts helps to maintain optimised performance and validates your guarantee HEPA filter kit Type 4 1 9 126184 00 Belt Type 1 1 1 130669 01 Technical Specification Voltage 220 240V 50Hz Wattage 1800 2000W varies by model Capacity 3L approx Filters Pleated paper HEPA filter HEPA antibacterial some models only Cord length 7 5m approx Weight 6 7 6 9kg in use varies by model Subject to technical change without notice EEC Statement of Complian
6. ce Manufacturer EEC importer Vax Limited hereby on our own responsibility declare that the VRS24B VRS25R is manufactured in compliance with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice You re home Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk
7. dle the plug or vacuum cleaner with wet hands Do not use outdoors or on wet surfaces Turn off the vacuum cleaner controls before disconnecting or connecting from the electrical socket Always unplug the vacuum cleaner before connecting or disconnecting the hose and accessories Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Only use as described in this manual Only use Vax recommended attachments Do not use the vacuum cleaner if it has been dropped damaged left outdoors or dropped into water Do not use the vacuum cleaner with a damaged cord or plug If the supply cord is damaged it must be replaced by the manufacturer or a recommended Service Agent to avoid hazard and invalidating the guarantee Do not pull or carry by cord Do not use the cord as a handle close a door on the cord or pull cord around sharp edges or corners Do not run the vacuum cleaner over the cord Keep he cord away from heated surfaces Do not put any objects into openings Do not use with any openings blocked and do not restrict air flow Keep all openings ree of dust lint hair or anything that might reduce airflow Keep ha
8. he dirt container on page 5 The dirt container may be incorrectly installed remove the dirt container from the unit by pressing the dirt container release catch and then re attaching it to the unit ensuring it is locked firmly back into place What do do if the unit an accessory becomes damaged or broken e We re here to help Simply call 0844 412 8455 or visit vax co uk Why won t the accessories pick up properly e Hose blockages remove the hose from the unit Carefully remove any blockages found and reconnect hose securely e Accessory blockages remove accessory from handle tube Carefully remove blockage and re attach to the vacuum cleaner e The accessory may be faulty Simply call us on 0844 412 8455 for assistance Why will the vacuum cleaner not run e It may not be plugged into the electrical socket correctly ensure that the plug is pushed in securely e The electrical socket may not be working properly check the fuse or breaker or consult an electrician e The motor thermostat may have tripped switch off and unplug the vacuum cleaner and leave for one hour before switching the cleaner back on Why isn t my brushbar rotating e The brushbar may not be turned on Refer to the operation section page 7 e The unit may not be reclined Refer to the operation section page 4 e The brushbar may be jammed Refer to the maintenance section for how to reset the brushbar page 7
9. ir loose clothing fingers and all parts of the body away rom openings and moving parts Do not pick up hot coals cigarette butts matches or any hot smoking or burning objects Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours Do not vacuum up harmful or toxic materials chlorine bleach ammonia drain cleaner etc Do not vacuum up hard or sharp objects such as glass nails screws coins etc Do not use without ALL of the filters in place Take extra care when vacuuming on stairs Keep vacuuming area well lit Store the vacuum cleaner in a cool dry area Turn off the on off switch before unplugging the vacuum cleaner Use only CE approved 13 amp extension cords Non approved cords may overheat Care should be taken to arrange the cord so that the cord cannot be tripped over WARNING Always switch off and unplug the vacuum cleaner from he electrical socket before assembling opening or emptying the dirt container or before connecting disconnecting the attachments CAUTION The vacuum cleaner is a very powerful unit Before plugging the cord into the electrical socket make sure the switch is in the off position MPORTANT If the inlet hose or telescopic tube is blocked switch off he vacuum cleaner and remove the blockage s before re starting the vacuum cleaner See Maintenance Clearing blockages MP
10. ise until secure on the upper cover of the tube with the slots on the motor To secure the dirt hose container push the top in place there will be an audible click when it is secure to remove the power cord Wrap the hose round and through the hose clip and then down and insert into hose connector This vacuum cleaner is equipped with a convenient cord storage feature The power cord winds around the two cord holders at the side of the unit The bottom cord holder has a quick release feature Turn the cord hook to the left or the right Operation Operating the appliance Turn the vacuum cleaner To adjust the angle of the Move the handle to the Secure the top handle to on by pressing the on off vacuum cleaner body desired position A for the back panel by inserting switch located on the push the recline pedal upright position B for the two long screws lower right side of the on the lower left side of normal operation and C cleaner The cleaner can the cleaner to clean under furniture be turned off by pressing the on off switch again The front of the vacuum cleaner has a brushbar height adjuster that raises and owers the brushbar to suit the type of carpet With the cleaner NOT connected o the electrical outlet and when the vacuum is in the upright position set the adjustment to the lowest setting for maximum cleaning If the cleaner i
11. on the agitator pulley and that the brushbar turns Replace the vacuum head cover hen reattach the brushbar height adjuster knob Secure parts by screwing in one 1 screw underneath the small wheel flap and the five 5 screws on the underside of the vacuum cleaner WARNING to reduce the risk of personal injury unplug the vacuum cleaner before performing maintenance troubleshooting checks Is there an accessory missing e Check the Parts Overview page in this guide to make sure the part is definitely included in your unit e If it is missing we re here to help Simply call us on 0844 412 8455 Why won t the vacuum cleaner pick up e The dirt container may be incorrectly installed remove the dirt container from the unit by pressing the dirt container release catch and then re attaching it to the unit ensuring it is locked firmly back into place The filter may be clogged refer to Maintenance Cleaning the filters on pages 5 and 6 The dirt container may be blocked refer to Maintenance Emptying and cleaning the dirt container on page 5 There may be a blockage in the tube hose Disconnect from the vacuum cleaner carefully remove any blockages found and reconnect securely Why is dust escaping from the vacuum e The filter may be clogged refer to Maintenance Cleaning the filters on pages 5 and 6 The dirt container may be blocked refer to Maintenance Emptying and cleaning t
12. s difficult o move push the knob to the next highest setting until the vacuum is comfortable o push The brushbar must reach the carpet for effective cleaning IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and tools the brushbar height adjuster must be set to the highest position WARNING To avoid injury keep loose clothing hair fingers and all other parts of he body away from any moving part such as the brushbar Turn off the switch and unplug the cleaner before adjusting the cleaner for the carpet height The accessories can be used with or without the extension tube To attach remove the hose from the machine and push the desired accessory onto the end Crevice Tool Use the crevice tool for radiators crevices corners skirting boards and between cushions TurboTool Some models only For pet hair stairs and upholstery The TurboTool should be pulled backwards for optimum cleaning Maintenance Keep your Vax as good as new Emptying and cleaning the dirt container IMPORTANT Always unplug the unit from the electrical outlet before opening the dirt container IMPORTANT Do NOT use the vacuum without the HEPA filter in place To remove the dirt Remove the dirt container Empty all the dirt from Remove the filter by container press the dirt lid by grasping the dirt the container twisting anti clockwise