Home

Platinum T129K1 cable network tester

image

Contents

1. appears in the top of the screen e The length constant measured in picofarads per unit length displays in the bottom of the screen NOTE Each press of the LENGTH TONE button toggles between displaying the measured cable length and the length constant After a few seconds the display screen defaults back to the measured length P N T129 PLATINUM TOOLS VDVMapMaster20 Voice www platinumtools com 2012 Platinum Tools Inc All rights reserved 5 12 USING LENGTH MODE continued MASTER REMOTE Adjust the Length Constant Value The VDV MapMaster2 0 has default length constant values for voice video and data cables These values shown in Table 8 are common length constants that apply to these cable types You can adjust the length constant value according to the specifications of the cable you are testing Length Constant T icof ft NOTE Bypass this section if the default da CELE PEE values see chart to the right stored in 17 pf ft the tester s memory satisfy the length Data 15 pf ft constant values for the cables you are 15 pf ft measuring NOTE The length constant value last set for each connector type voice video or data is stored in the unit s memory If you have not adjusted the length constant value for any or all cable types the default values will be stored The length constant can be adjusted at any time 1 When in Length Mode press and hold the LENGTH TONE button un
2. be connected at the same time held until LOOP ON is displayed tests are run continuously and the display updated until the O ID button is pressed or after 5 minutes of no change in ID MAPPING results Continuous mode is useful for finding intermittent problems D Length Tone Tone Mode When tone is pressed the VDV MapMaster2 0 begins sending an audio tone for the connector last tested with the pins and cadence previously selected for that connector type To change the connector type press a different connector type button Pressing the same connector type button again will change the pins carrying the tone Pressing the Tone button will cycle through the available tone cadences To turn the VDV MapMaster2 0 off press the O ID button The VDV MapMaster2 0 will turn off automatically 60 minutes after the last button press The tone is compatible with analog tone tracers ID Mapping Pressing the 0 ID button PINTI29 PLATINUM TooLs starts the ID test mode on the VDV VDVMapMaster 20 MapMaster2 0 Review section E under category KEYPAD ID MAP Voice Data Video up to 19 locations at one time with numbered custom ID remotes whether Voice RJ12 11 Video coax or Data RJ45 Place ID remotes at one end the VDV MapMaster2 0 at the other end and start scanning Mode Locator ID ee Www platinumtools com 2012 Platinum Tools Inc All rights reserved 5 12 WIRING and DISPLAY EXAMPLES
3. number and the Short indicator Tester End Wire Map The top line displays the pins on the tester end in order These pins are mapped to the pins on the remote end shown directly below them on the LCD Remote End Wire Map The bottom line displays the corresponding pin on the remote end Dash lines on the remote line indicate short pins No pin numbers displayed on the remote line are open pairs Battery Low The battery low symbol illuminates when the battery is nearing depletion The symbol will begin to flash when the battery needs to be replaced Results may be unreliable at this point Location ID In the video or the ID modes the ID icon will be on with the number of the remote ID displayed or an error message of Open or Short Voltage Detected Warning If voltage is detected on any of the tester connectors the Voltage icon is turned on A check for voltage is performed before each test and if found no test is run The tester should be disconnected immediately from the source of the voltage Length Mode When the LENGTH TONE button is pressed the measured cable length in units of feet or meters appears in the lower right corner of the LCD display screen and the L icon appears above pins 7 and 8 in the Wire Map The following values and icons display in the screen when measuring cable length Edit Capacitance A long press two seconds of the button allows you to edit the length constant Whe
4. LOOP ON is displayed tests are run continuously and the display updated until the 0 ID button is pressed or after 5 minutes of no change in results Continuous mode is useful for trouble shooting intermittent problems E In Length Mode the yellow arrow allows you to adjust the length constant value A short press of the Voice and Video buttons simultaneously changes the length measurement unit from feet to meters B Video Pressing the Video button starts the ID test testing only for the F connector because the video continuity test is the same as the ID test The test loops continuously until the O ID button is pressed or for 5 minutes after the last change in ID status In Length Mode the yellow arrow allows you to adjust the length constant value NOTE A short press of the Voice and Video buttons simultaneously changes the length measurement unit from feet to meters C Data Each press of the Data button causes one test to be run on the 8 position RJ jack and the results displayed The VDV MapMaster2 0 will turn off after 15 seconds automatically If the button is pressed and over miswires and the appropriate icon s illuminates The Split icon illuminates if the designated pairs are not twisted together in the cable an AC signal fault Shield Shielded illuminates when a shielded data cable is properly connected at both ends It will be flashing if there is a short to a wire in the cable along with that pin
5. Properly Wired T568A UTP T568A Cable with Split Pairs gt 1 1 a al 2 2 2 13 3 a 2 S 5 512 S e 6 a a 7 7 gt gt 8 8 Properly Wired T568A UTP T568A Cable with Split Pairs T568B is electrically identical to T568A but swaps the green and A common error in building a cable is to put all the pairs in pin orange pairs Either standard will work as long as the same sequence 1 2 3 4 5 6 and 7 8 This will produce the correct standard is used at both ends of a run or patch cable Mixing A continuity but the pairs are designated to be on pins 3 6 and and B creates a cross over cable 4 5 in the middle of the connector for compatibility with phone wiring This wiring error is only detected by the split pair test since the designated pairs are not twisted together P N T129 PLATINUM TOOLS VDVmapMaster 2 0 P N T129 PLATINUM TOOLS VDVMapMaster2 0 Z 8 FLASHING T568A Cable with a Miswire and T568A Cable with a Unrecognized Continuity Short and Open VDV MapMaster jow y VDV MapMaster jow y CONOOBRWBDND gt T568A Cable with a Miswire and unrecognized Continuity T568A Cable with a Short and an Open 1 and 2 pins on the VDV MapMaster2 0 are connected to pins The 1 2 pair pins are shorted together and the 7 8 pair is open The pins with the errors are flashing Dash lines on the bottom 2 and 1 at the remote end The pins with this error are
6. VDVMapMaster 2 0 Voice Data Video Length Instruction Sheet P N T129 MADE IN L a PLATINUM TOOLS The Platinum Tools VDV MapMaster2 0 is a portable voice data video cable tester with length measurement It tests and troubleshoots RJ11 RJ12 RJ45 and F conector terminated cables and provides built in tone generation for cable tracing e Dimensions 6 4 x 2 8 x 1 4 16 3 x 7 1 x 3 6 cm e Weight 9 0 oz 256 grams with battery and remote o Operating Temperature 0 C 32 F to 50 C 122 F e Storage Temperature 20 4 F to 60 C 140 F e Humidity 10 to 90 non condensing e Maximum Voltage between any two connector pins without damage RJ Jack 66V DC or 55V AC F Connector 50V DC or AC e Battery Life 9V alkaline battery typical Standby 4 years Active 425 hours e Cable Types Shielded or Unshielded Cat7 Cat6x Cat5e Cat5 Cat4 Cat3 Coax e Maximum Coax Cable Length e Maximum RJ Cable Length 0 to 1 000 feet 305 meters e Minimum Cable Length for Split Pair Detection 1 5 feet 0 5 meters e Low Battery Icon flashes when battery voltage falls below 6V e Measurement Technology Capacitance testing e Length Accuracy Without Length Constant Accuracy 3 plus 1 foot e Cable Length Measurement 1 to 2 000 ft CAT5E cable with 15 pF ft length constant o Default Length Constant Restored with power on reset e Voice 17 4 pF ft e Video 16 5 pF ft e Data 15
7. d for network testing Coax Remote Set P N T120C ID MAP 19 video coax cables at one time Numbered custom F remotes 1 thru 19 for easy identification Data Remote Set P NT121C ID MAP 19 data twisted pair cables or data ports jacks at one time Numbered custom RJ45 remotes 1 thru 19 for easy identification Master Remote P NT124C The replacement Master Remote s can be used as an extra Master Remote s when testing networks Map your network first to help identify the extra Master Remote s Toner Cable P N T125C RJ45 Alligator Use when shooting tone via the data port Cable conductors are terminated on contact 1 and 2 so program your VDV MapMaster to shoot tone on pair 1 and 2 NO Fault Cable P NT126C 7 5 Special RJ12 to RJ12 The NO Fault Cable uses no fault RJ12 connectors on both ends to assure no damage to the RJ45 jacks It is the ideal patch cable to use when mapping or b a shooting tone 2g RJ45 PortSaver P N 21025 Extend the life of your tester by using the RJ45 PortSaver as your sacrificial cable This eliminates the wear and tear from constantly plugging in and out of the tester port Hanging Pouch P N 4007 Durable pouch for safe storage and transport of your tester ees www platinumtools com 2012 Platinum Tools Inc All rights reserved 5 12
8. flashing remote display line indicate the short while no numbers on the The U for the remote pin numbers indicates an unrecognizable bottom line indicate the open pair continuity was detected that is neither a short or open An ID remote connected to the VDV MapMaster2 0 when in cable test mode would also show this error P N T129 PLATINUM TOOLS VDVMapMaster 20 P N T129 PLATINUM TOOLS VDVmapMaster20 ee www platinumtools com Measure Cable Length Measures the entire length of a cable as well as the length of individual wire pair NOTE Using Coax or Network wire mapping remotes while measuring length will add one to two feet to the length reading due to internal stray Capacitance 1 Make sure the power is turned OFF 2 Insert the cable plug into the corresponding receiver on the main tester RJ11 jack for voice cables RJ45 jack for data cables F Connector for video cables 3 Press the LENGTH TONE button to enter Length Mode The ilies PLATINUM TOOLS following icons appear in the display screen to the right VDV map Master 2 0 e An L icon appears in the Video right side of the screen e Cable length in units of feet or meters displays in the bottom of the screen e The connector type last selected voice data or video displays in the top of the screen e An 0 symbol bounces in the lower left corner of the screen to indicate activity NOTE Measuring cable length
9. is the primary function of the LENGTH TONE button If you hold down the button too long you will enter Tone Mode If you mistakenly enter Tone Mode simply press the 0 ID button and select the LENGTH TONE button again to enter Length Mode 4 Change measurement units The units can be changed from feet to meters and back again by quickly pressing the VOICE and VIDEO buttons at the same time When the unit of measurement is set to feet the ft icon is displayed in the lower right corner of the screen When meters are selected the unit of measurement is not displayed 5 Verify the connector type appearing in the display screen matches the connected cable If it does not match press the cable type button corresponding to the cable you plan to measure voice video or data NOTE If you do not select the cable test mode matching the connected cable the tester will try to measure the previously tested cable and may skew the measured length results 6 Measure Entire Cable After selecting the cable type button for the connected cable the measured length reading shown in the display screen is representative of the entire cable NOTE Voice and Video length modes automatically select and display the length of the first pin pair without a fault For cables with no faults the length of pair 1 2 for Data Mode and pair 3 4 for Voice Mode will automatically appear in the display screen The Tester Pin field is blank when the length reading f
10. n RJ plug before inserting it into the tester The contacts should always be recessed into the plastic housing of the plug Plugging 6 position plugs into the 8 position jack on the tester has the potential to damage the outermost contacts of the jack unless the plug is specifically designed for that purpose ee www platinumtools com 2012 Platinum Tools Inc All rights reserved 5 12 DISPLAY P N T129 PLATINUM TOOLS VDVMapMaster20 4 Voice Data Video Tone Pass X over Rev Fail Short Split Open 5 Shielded Voltage _ID 7 1234567 HEETE 1 Mode The top line displays the cable type test mode or tone 1 generation mode 2 Pass Special Cables Pass will be on if the cable is a properly wired 4 pair T568A B data cable a 3 pair one to one wired voice 8 cable or a video cable with no faults In addition X over illuminates if a properly wired cross over uplink cable is recognized or the Rev illuminates if the cable is a properly wired reverse pinned 9 voice cable The wire map will show actual pin connections 3 Cable Faults The Fail icon will be on only if the cable is not wired to one of the cabling standards An open or short error takes precedence A Voice Each press of the Voice button causes one test to be run on the 6 position RJ jack and the results displayed The VDV MapMaster2 0 will turn off after 20 seconds automatically If the button is pressed and held until
11. n adjusting the length constant value for a Cable the Edit Cap icon appears in the bottom of the screen An E icon displays above pins 7 and 8 in the Wire Map to indicate you are in Edit Mode Length Constant Value A value measured in picofarads pF per foot or meter appears in the bottom of the LCD display screen This value corre sponds to the selected cable type and can be adjusted at any time When viewing the length constant value for a cable type the C icon displays above pins 7 and 8 Off ID 0 ID Pressing O ID will turn off the VDV MapMaster2 0 when it is on in any mode With the VDV MapMaster2 0 off pressing the 0 ID button starts the ID test mode The ID test mode scans for all possible ID types voice video and data The ID icon and a progression of o are displayed on the bottom line of the display to indicate scanning is active If no ID remotes are found Open is displayed When and ID remote is found the connector type and the ID number are displayed If multiple ID remotes are found the ID or fault is displayed in sequence The test loops continuously until the OD button is pressed or for 5 minutes after last change in ID status The RJ jacks share internal connections so only one RJ cable can be connected at a time for accurate cable test results However an RJ cable and a coax cable may be connected at the same time In ID mode all connectors on the VDV MapMaster2 0 may
12. or the entire cable is displayed Refer to Step 7 below for instructions on stepping through the wire pairs Refer to the LCD Display Screen section for a description of the Tester Pin field 7 Measure Pin Pairs Press the cable type button again to measure the length of the first pin pair The number s for the pair being measured will display in the screen see Figure 14 Subsequent presses of the cable type button will cycle through all the pairs and return to the length reading for the entire cable when you have advanced past the last pin pair The following icons appear in the display screen below e The cable type icon appears at the top of P N T129 PLATINUM TOOLS the screen e Length of pin pairs in VDVMapMaster 2 0 units of feet or meters displays in lower right corner of the screen e The L icon displays indicating you are in Length Mode e A bouncing ball activity indicator appears in the lower left corner NOTE If the selected cable pair is shorted SHORT will display for the shorted pair and the length readout is dashes 8 Interpret display results and trouble shoot potential cable faults View the Lenght Constant 1 While in Length Mode press the LENGTH TONE button again to view the length constant The following occurs in the display screen below e The L icon changes to C indicating the length constant is being displayed e The connector type voice data or video
13. pF ft C Complies with Conformit Europ enne directives Coax Type Belden P N Center Shield Maximum Length RG 58A U 8259 14 9Q 1 000 ft 6 710ft 2 045m 9311 25 8Q 1 000ft 3 876ft 1 182m 7806A 11 8Q 1 000ft 8 475ft 2 583m RG 59 U 9310 24 12 1 000ft 4 150ft 1 265m 9259 23 5Q 1 000ft 4 255ft 1 297m 8241A 49 702 1 000ft 2 010ft 613m 9275 78 5Q 1 000 1 275ft 389m o 9659 17 6Q 1 000ft 5 682ft 1 732mM RG 6 U 1694A 7 2Q 1 000ft 13 889ft 4 234m 1152A 29 8Q 1 000ft 3 360ft 1 025m Mini Coax 9221 1110 1 000ft 900ft 275m RG 11 U 1523A 15 10 1 000ft 6 623ft 2 019m 1 Remove single screw in the middle of the back of the VDV MapMaster2 0 with a 1 Phillips head screwdriver Remove the battery door 2 Remove the old battery and disconnect battery cable 3 Replace with an ANSI 1604A 9 volt alkaline battery Energizer 522 Duracell Mn1604 Reattach cable and insert into battery compartment 4 Replace battery door and screw DO NOT OVERTIGHTEN To ensure safe operation and service of the tester follow these instructions Failure to observe these warnings can result in severe injury or death e The VDV MapMaster2 0 is designed for use on unenergized cabling systems Connecting the VDV MapMaster2 0 to live AC power may damage it and pose a safety hazard for the user e Poorly terminated RJ plugs have the potential to damage the jacks on the VDV MapMaster2 0 Visually inspect a
14. pdated as the length display is changing 3 Select the LENGTH TONE button again to measure the connected cable under the parameters of the new length constant NOTE If the cable s capacitance is too large dashes will display for the length Changing the connector type or exiting Length Mode will store the adjusted length constant in the units memory for the next test Up to three length constants can be stored one of each connector type Length Constant Accuracy The length constant refers to the electrical parameter used to measure length in this case the capacitance of the cable per foot or meter Accuracy is dependent on how close the instrument can be set to the cable constant for the cable being measured The length constant can vary from cable to cable of the same type produced by the same manufacturer It can also vary over the length of one cable because the length constant is dependent on the physical properties of the cable which may not be consistent throughout the entire cable The change in wire pair spacing through the cable can vary the length constant along the length of the cable The VDV MapMaster2 0 Remote designed for testing both Voice RJ12 11 and Data RJ45 networks Patch cables can be tested without removing the remote from storage NOTE extra master remotes can be used simultane ously if mapping is done first so each master remote can be identified Master Remote use
15. til CALER PLATINUM TOOLS EDIT CAP appears in the bottom of the display screen The following VD VmMap Master 2 0 updates listed below occur in the display screen The selected connector type voice data or video appears in the top of the screen An E will display in the right side of the screen to indicate you are in Edit Mode The display screen toggles between the current length reading and the length constant value 2 Adjust the Length Constant value for the cable you are testing In Edit Mode the VOICE and VIDEO Mode buttons function as Up and Down yellow arrows are denoted on the buttons You can use these buttons to adjust the length constant over a range of 10 to 40 picofarads per foot in 0 1pF ft increments NOTE While editing the display screen toggles back and forth between the length constant value and the measured cable length You can edit the length constant value when the length constant is displayed Continuously pressing the UP or DOWN buttons keeps the length constant on the display screen Toggling begins when a few seconds have lapsed after the last button press You can also edit the length constant value while the measured length is displayed in the screen This is helpful when you know the length of the cable Press the UP DOWN buttons while length is displayed in the screen Continue to adjust the length constant until the reading matches the known cable length The length constant is being u

Download Pdf Manuals

image

Related Search

Related Contents

Deutsch - CaravanMoverShop.de  Czech Technical University in Prague Spectroscopic Investigation of    *2098695* 2098695  Robert Bosch VE-type Injection Pump  Workswell Thermal Vision – User Manual  Sanyo PLC-XL50A User's Manual  Curso IVACE Calener GT - Agencia Valenciana de la Energía, AVEN  Product Info Benefits and Features Built-in Power  Benutzerhandbuch - Hewlett  

Copyright © All rights reserved.
Failed to retrieve file