Home

Panduit WGWMTB1830BL mounting kit

image

Contents

1. Cable Tray Routing System Fast ctrong cimple WA Vien 7 building a smarter unified business foundation Connect Manage Automate Panduit s Unified Physical Infrastructure UPI a Guiding Approach A unified approach to physical and logical systems architecture is imperative for solutions to fully address the need for availability agility integration and security Panduit has developed the industry s most comprehensive and holistic approach to a Unified Physical Infrastructure and can help enterprises align converge and optimize critical systems communication computing control power and security to build a smarter unified business foundation Mitigate Risk Efficient physical infrastructure management enables seamless integration to reduce risks which can occur throughout core systems Lower Cost Panduit physical infrastructure solutions drive financial advantages to reduce energy and occupancy costs and help secure competitive advantage Increase Agility A high level of integration within the physical infrastructure enables flexibility and improved business agility Enhance Sustainability UPl based solution offerings enable organizations to meet sustainability goals by driving resource and energy efficiencies across the physical infrastructure Unified Physical Infrastructure Z al communication computing control power security 2 visit w
2. WG12FRTBBL Wyr Grid 12 305mm width FiberRunner QuikLock Trapeze 1 Bracket Attaches to the Wyr Grid 12 305mm wide Pathway to support a secondary FiberRunner 4x4 or 6x4 Channel above the pid a Wyr Grid Pathway Available in black powder coat only WG18FRTBBL Wyr Grid 18 457mm width FiberRunner QuikLock Trapeze 1 Bracket Attaches to the Wyr Grid 18 457mm wide Pathway to support a secondary FiberRunner 4x4 or 6x4 Channel above the WG18FRIBBL Wyr Grid Pathway Available in black powder coat only a WG24FRTBBL Wyr Grid 24 610mm width FiberRunner QuikLock Trapeze 1 Bracket Attaches to the Wyr Grid 24 610mm wide Pathway to support a secondary FiberRunner 4x4 or 6x4 Channel above the WG24FERTBBL Wyr Grid Pathway Available in black powder coat only WG30FRTBBL WYyr Grid 30 762mm width FiberRunner QuikLock Trapeze 1 Bracket Attaches to the Wyr Grid 30 762mm wide Pathway to support a secondary FiberRunner 4x4 or 6x4 channel above the Wyr Grid Pathway Available in black powder coat only WG30FRTBBL Wyr Grid Mounting Bracket for Strut WGSKBL Strut mounting clip assembly allows Wyr Grid Pathway to be 1 5 ay attached directly to standard 1 5 8 wide strut structures Contains support member two clips and all hardware for assembly WGSKBL For electro zinc finish replace BL Black with EZ PAN DUIT SC man Specifications Wyr
3. 100th of the span between supports in the longitudinal direction as shown in Figure 1 Furthermore the transverse deflection at the SWL must be less than 1 20th of the cable tray width as shown in Figure 2 The SWL ratings in the table apply for Wyr Grid Cable Tray installed in any of the following configurations cable tray only straight splice cross intersections and tee intersections in applications where power cables or premise distribution fiber cables are routed on the Wyr Grid Pathway the Safe Working Loads SWL also apply Wyr Grid Pathways No Sidewall Removal Required Table 2 Cable Load Ibs ft Safe Working Load Ibs ft Tray 4 Foot 5 Foot 6 Foot 7 Foot 8 Foot 9 Foot Width Category Category Category Support Support Support Support Support Support Part Number In 6A SD 6A 6 Span Span Span Span Span Span WG12BL10 12 24 21 18 06 25 02 113 90 69 54 43 34 WG18BL10 18 36 15 26 99 3736 115 90 67 52 41 31 WG24BL10 24 48 09 35 91 49 69 116 92 69 54 53 33 WG30BL10 30 60 00 44 80 62 00 116 92 69 54 53 33 The cable load is defined by the maximum wire fill as shown in Table 1 for each pathway width and 6 depth For electro zinc finish replace BL Black with EZ 14 visit www panduit com Dm L 100 NE ee ee ee ee MOS MA Lg L Length Between Supports Figure 1 Midspan Deflection Schematic of Cable Tray Side View Standards Compliance UL Underwriters Laboratories Inc Underwriters Laborat
4. AA V down the integral screw unlike other systems that require loose hardware requires no tools cutting or hardware When cutting is called for there are fewer wires to cut Wyr Grid Pathways are easily bonded by simply tightening Intersection bend radius control A AR Wr 7 7 s Ih n S3 i gt A 5 a i iy i P NZ j gt EN TI ray H AV vy TP A RY Cia A R EER y DANS ys VAN 5 K f i a Ti Wa 2 v Gyr S f W N lt A oe 7 VO Wi X y Wyr Grid Splice Connectors install by hand without the use of special tools unlike other systems Pee Typical Wyr Grid Overhead Cable Tray System and FiberRunner Cable Routing System Data Center Application The cable routing systems are configured to route and protect cabling between the Main Distribution Area MDA or Horizontal Distribution Area HDA and the Equipment Distribution Area EDA This complete overhead pathway solution enables both copper and fiber cables to be effectively routed within the data center As shown below copper data cables are routed along the Wyr Grid Pathway and small diameter fiber interconnect cables patch cords are routed through the FiberRunner Pathway In the event that routing power cables overhead is also required another level of the Wyr Grid System can be added above the FiberRunner System Optional snap on sidewall
5. Equipment Distribution Areas EDA Key product features significantly reduce installation time enhance cable management and improve user safety Because the pathway has no integral sidewalls the need to cut the sidewalls at intersections waterfalls fabricated directional changes and straight sections is eliminated Intersection bend radius control accessories install with no hardware or tools and provide a three inch bend radius guide Splice connectors provide integral bonding improving user safety As shown below these features allow copper data cables to be effectively routed throughout the data center In applications where power cables are also routed overhead another level of Wyr Grid Pathway can be added to manage these cables In addition premise distribution fiber cables can also be routed on a separate level of the Wyr Grid System A hardware kit is available to facilitate the fabrication of right angles on the job site Power cables shown routed on a separate level of Wyr Grid Pathway Waterfalls require no cutting or hardware for installation Panduit QuickNet Cassettes pass through Wyr Grid openings eliminating the need to cut the pathway eee ti Route redundant A and B cabling into adjacent cabinets with a single waterfall 4 visit www panduit com datacenter No sidewall cutting at intersections A gt tat W V A f Na A 2 al 3 y HANAN
6. for bonding jumpers between pathway sections NEMA VE1 CSA 22 2 Metal Cable Tray Systems Certification to this standard ensures that electrical continuity exists between pathway sections when joined together with the splice connectors complying with the electrical resistance requirements of the standard Furthermore the load rating has been identified ensuring the pathway sections will not fail when utilized for its intended application EN 61537 2007 Cable management Cable tray systems and cable ladder systems All Wyr Grid Overhead Cable Tray Routing System components are ROHS compliant The Wyr Grid Overhead Cable Tray Routing System is offered with two different Design Tools that allow accurate system drawings to be created which speeds overall system design specification and implementation Both VISIO and AutoCAD versions are available as free downloads from www panduit com products selectiontools Wyr Grid Design Tool for AutoCAD includes e Drag and Drop Functionality e Ability to design in 2D or 3D e Versions Compatible with AutoCAD and AutoCAD LT e Automated BOM Generator Data Center VISIO Layout Tool includes e Drag and Drop Functionality e Ability to design in 2D stencils for three different views are provided e Automated BOM Generator VISIO is a registered trademark of Microsoft Corporation in the United States and or other countries AutoCAD is a registered trademark of Aut
7. 2 or 12 mm threaded rod and 30 762mm e Standard finishes are black powder coat and electro zinc plated Std Std Pkg Ctn Part Number Part Description Qty Qty WGTBS8BL Wyr Grid Trapeze Brackets WGTBS8BL Used to support 8 203mm wide Wyr Grid Pathway from the 1 5 ceiling using a pair of 1 2 or 12mm threaded rod drops Hardware for attaching to threaded rod sold separately see page 13 WGTBS12BL WGTBS12BL Used to support 12 305mm wide Wyr Grid Pathway from the 1 5 ceiling using a pair of 1 2 or 12mm threaded rod drops Hardware for attaching to threaded rod sold separately see page 13 WGTBS18BL Used to support 18 457mm wide Wyr Grid Pathway from the 1 5 WGTBS18BL ceiling using a pair of 1 2 or 12mm threaded rod drops Hardware for attaching to threaded rod sold separately see page 13 WGTBS24BL Used to support 24 610mm wide Wyr Grid Pathway from the 1 5 ceiling using a pair of 1 2 or 12mm threaded rod drops Hardware for attaching to threaded rod sold separately see page 13 WGTBS24BL WGTBS30BL Used to support 30 762mm wide Wyr Grid Pathway from the 1 5 ceiling using a pair of 1 2 or 12mm threaded rod drops Hardware for attaching to threaded rod sold separately see page 13 Wyr Grid Cantilever Brackets WGTBS30BL WGCB12BL Used to support the 12 305mm wide Wyr Grid Pathway along 1 5 a wall Integral retaining clip secures the pathway to the bracket Mounting hardware
8. 69 6 73 0 807 516 807 6 145 0 1603 1026 1603 2 36 3 401 257 401 2 60 3 666 427 666 1821 4 72 7 804 514 804 390 2 4 120 7 1334 854 1334 6 109 0 1205 771 1205 6 181 0 2000 1280 2000 Y equates to the height of the Wyr Grid Optional Sidewalls The internal area defines the allowable fill capacity based on the Wyr Grid Pathway width and optional sidewall height The Wyr Grid Pathway cable fill is based on NEC allowable fill of 50 The above cable diameters represent the nominal Panduit cable diameter per performance level Load Rating for Wyr Grid Pathways Two different industry standards provide methods by which the load rating of a cable tray system is identified Those standards are EN 61537 2007 Cable management cable tray systems and cable ladder systems and NEMA VE1 CSA 22 2 Metal Cable Tray Systems The EN 61537 2007 standard takes into account various pathway configurations such as Tee Intersections Cross Intersections Straight Sections and Straight Sections with Splice Connectors The NEMA VE1 CSA 22 2 load rating test strictly evaluates the straight sections and does not address any of the directional changes that would need to be fabricated in the field Furthermore it does not identify a deflection limit for the loaded pathways When specifying a cable tray system it is imperative that the system will support the required load in any pathway configuration without excessive deflection Therefore the EN 61537 2007 test re
9. Grid Accessories e Offered in three different heights 2 50mm 4 102mm e Standard finishes are black powder coat and and 6 152mm WGSW2BL WGSW4BL WGSW6BL WGINTBRC2BL WGINTBRC4BL WGINTBRC6BL WGHRDWKTBL 12 visit www panduit com electro zinc plated Std Std Pkg Ctn Part Number Part Description Qty Qty Wyr Grid Pathway Snap On Sidewalls WGSW2BL Wyr Grid 2 50mm high Snap On Sidewalls can be attached 1 40 anywhere along the pathway where needed to retain cables WGSW4BL Wyr Grid 4 102mm high Snap On Sidewalls can be attached 1 40 anywhere along the pathway where needed to retain cables WGSW6BL Wyr Grid 6 152mm high Snap On Sidewalls can be attached 1 40 anywhere along the pathway where needed to retain cables For electro zinc finish replace BL Black with EZ Wyr Grid Pathway Intersection Bend Radius Controls WGINTBRC2BL Wyr Grid 2 560mm high Snap On Intersection Bend Radius 1 Control provides 3 76mm bend radius control and can be installed without cutting or fabrication at tees crosses and right angle intersections WGINTBRC4BL Wyr Grid 4 102mm high Snap On Intersection Bend Radius 1 Control provides 3 76mm bend radius control and can be installed without cutting or fabrication at tees crosses and right angle intersections WGINTBRC6BL Wyr Grid 6 152mm high Snap On Intersection Bend Radius 1 Control provides 3 76mm bend radius con
10. ar pathway sections providing a completely bonded connection ensuring electrical continuity between the pathways Package contains two components needed to create one tee or right angle intersection For electro zinc finish replace BL Black with EZ WGINTSPLBL Wyr Grid Waterfalls e Offered in two different configurations that attach to e Standard finishes are black powder coat and all pathway sections 8 203mm 12 305mm 18 electro zinc plated 457mm 24 610mm and 30 762mm Std Std Pkg Ctn Part Number Part Description Qty Qty WGBTMWFBL The bottom waterfall provides 1 38 85mm bend radius control for 1 10 cables transitioning down into the racks or cabinets from within the Wyr Grid Pathway The waterfalls can be installed side by side increasing the overall width of the waterfall WGBTMWFBL WGSWF4BL The side waterfall provides 3 76mm bend radius control for cables 1 transitioning down into the racks or cabinets from the side of the Wyr Grid Pathway Cable retaining posts ensure bend radius control as cables traverse from the horizontal into the vertical path Plastic design only offered in black color WGSWF4BL For electro zinc finish replace BL Black with EZ PANDUIT Specifications Wyr Grid Support Brackets e Offered in various widths to accommodate pathways e Integral quick clip retention 8 203mm 12 305mm 18 457mm 24 610mm e Accommodates 1
11. for attaching to wall not included WGCB18BL Used to support the 18 457mm wide Wyr Grid Pathway along 1 5 a wall Integral retaining clip secures the pathway to the bracket WGCB12BL Mounting hardware for attaching to wall not included WGCB24BL Used to support the 24 610mm wide Wyr Grid Pathway along 1 5 a wall Integral retaining clip secures the pathway to the bracket Mounting hardware for attaching to wall not included WGCB18BL Wyr Grid Wall Mount Termination Brackets WGWMTB8BL Used to support the end of the 8 203mm Wyr Grid Pathway 1 5 against the wall Mounting hardware for attaching to wall not included WGWMTB12BL Used to support the end of the 12 305mm Wyr Grid Pathway 1 5 WGCB24BL against the wall Mounting hardware for attaching to wall LE not included WGWMTB1830BL Used to support the end of the 18 457mm 24 610mm or 1 5 WGWMTB8BL 30 762mm Wyr Grid Pathway against the wall Mounting hardware for attaching to wall not included Package contains two components needed to support the wider pathway sections For electro zinc finish replace BL Black with EZ WGWMTB12BL E WGWMTB1830BL X 10 visit www panduit com Wyr Grid Support Brackets continued Std Std Pkg Ctn Part Number Part Description Qty Qty Wyr Grid Mounting Brackets for FiberRunner System FRTBWG12BL FiberRunner QuikLock Threaded Rod Trapeze Bracket for 1 10 Wyr Grid 12 305mm width Used to supp
12. g Busbar TGB only required in one location GACBJ6 U Length in inches Available in 8 12 and 18 lengths Wyr Grid Hardware and Tools Std Std Pkg Ctn Part Number Part Description Qty Qty HNLW12 1 2 13 hex nut and lock washer for use in attaching trapeze 100 HNLW12 HNLW12M brackets to threaded rod o a HNLW12M 12mm hex nut and 12mm lock washer for use in attaching trapeze 100 brackets to threaded rod E Tools a FR716DR 7 16 nut driver for use with the FiberRunner GridRunner and 1 10 FR716DR Wyr Grid Systems 7 WGCT A Battery powered cutting tool for cutting Wyr Grid Cable 1 Trays 2 18 volt Lithium lon batteries and 115 volt 60 Hz charger included CD WGCD 1 Wyr Grid Replacement Cutting Die for the automatic cutting tool i eer WGCT M Manual cutting tool for cutting Wyr Grid Cable Trays 1 Weight 5 4 Ibs 2 45 kg WGCT M Pan DUIT n Specifications Wire Fill for Wyr Grid Overhead Cable Tray Routing System A n Table 1 a Internal Category 6A SD Category 6A Category 6 Internal Category 6A SD Category 6A Category 6 X Y Area Dia 0 240 Dia 0 300 Dia 0 240 X Y Area Dia 0 240 Dia 0 300 Dia 0 240 in in in 6 1mm 7 6mm 6 1mm in in in 6 1mm 7 6mm 6 1mm 2 24 3 269 172 269 2 48 3 534 342 534 122 4 48 7 538 344 538 242 4 96 7 1069 684 10
13. k powder coat and electro zinc plated e Non integral sidewalls minimize specification requirements Part Description 8 wide x 10 long pathway section used to carry cables horizontally throughout the system Snap on sidewalls attach for job specific height requirements Uses splice connector WGSPL1218BL to connect straight sections and intersection splice WGINTSPLBL to connect pathways at an intersection 12 wide x 10 long pathway section used to carry cables horizontally throughout the system Snap on sidewalls attach for job specific height requirements Uses splice connector WGSPL1218BL to connect straight sections and intersection splice WGINTSPLBL to connect pathways at an intersection 18 wide x 10 long pathway section used to carry cables horizontally throughout the system Snap on sidewalls attach for job specific height requirements Uses splice connector WGSPL1218BL to connect straight sections and intersection splice WGINTSPLBL to connect pathways at an intersection 24 wide x 10 long pathway section used to carry cables horizontally throughout the system Snap on sidewalls attach for job specific height requirements Uses splice connector WGSPL2430BL to connect straight sections and intersection splice WGINTSPLBL to connect pathways at an intersection 30 wide x 10 long pathway section used to carry cables horizontally throughout the system Snap on sidewalls attach for job specific height requirements Uses splice c
14. le results Panduit cultivates long term strategic alliances with industry leaders including Latin America 52 33 3777 6000 Cisco Systems EMC IBM and Rockwell Automation to develop optimize and Asia Pacific 65 6305 7575 validate solutions for our customers This investment in people and resources helps solve our customers greatest business challenges Www panduit com E Global Business Commitment Panduit is committed to delivering a consistently high level of quality and service the world over With a presence in more than 100 countries local Panduit sales aN representatives and technical specialists offer guidance and support that bring DUIT value to your business Our global supply chain which includes manufacturing customer service logistics and distribution partners provides prompt response to your inquiries and streamlines delivery to any worldwide destination Sustainability With a commitment to environmental sustainability Panduit develops and implements solutions that protect replenish and restore the world in which we live This commitment is demonstrated by Panduit s LEED Gold certified World Headquarters leveraging the Unified Physical Infrastructure approach to enable convergence of critical building systems to drive energy efficiency and ongoing operational improvement 2014 Panduit Corp ALL RIGHTS RESERVED Printed in the U S A FRCB01 SA ENG Replaces RKCB29 SA ENG 12 2014
15. odesk Inc PAN DUIT Real World Solutions With a proven reputation for excellence and innovation Panduit and our partners work with you to overcome challenges and implement real world solutions that create a competitive business advantage Panduit offers the broadest range of solutions from data centers and intelligent buildings to manufacturing operations to help you build a smarter unified business foundation Technology Leadership Panduit develops innovative physical infrastructure solutions that meet the rapidly changing needs of our clients from hardware and software to advisory services This commitment is supported by investment in advanced research solutions focused product development world class manufacturing and collaboration with customers at the forefront of technology Partner Ecosystem Our best in class partner ecosystem offers a comprehensive portfolio of services Panduit Corp World Headquarters Tinley Park IL 60487 that span the project lifecycle from planning and design to delivery deployment maintenance and operation Panduit business partners distributors and certified architects consultants engineers designers system integrators and contractors are qualified to helo you achieve your objectives and realize predictable and ae Ba NS a ae p cs panduit com US and Canada 800 777 3300 l l Europe Middle East and Africa K Strategic Alliances 44 20 8601 7200 measurab
16. onnector WGSPL2430BL to connect straight sections and intersection splice WGINTSPLBL to connect pathways at an intersection Order number of feet required in multiples of standard 10 length increments For electro zinc finish replace BL Black with EZ Std Pkg Qty 10 10 10 10 10 Wyr Grid Splice Connectors e Integral bonding screw creates a mechanical electrical e Standard finishes are black powder coat and bond between cable tray pathway sections electro zinc plated Std Std Pkg Ctn Part Number Part Description Qty Qty WGSPL1218BL Straight splice connector quickly joins two 8 203mm 12 305mm 1 10 or 18 457mm wide Wyr Grid Pathways together A thread cutting screw pierces the paint of adjacent pathway sections providing a completely bonded connection ensuring electrical continuity between the pathways Package contains two components needed to join two pathway sections WGSPL2430BL Straight splice connector quickly joins two 24 610mm or 30 1 10 762mm wide Wyr Grid Pathways together A thread cutting screw pierces the paint of adjacent pathway sections providing a completely bonded connection ensuring electrical continuity between the pathways Package contains four components needed to join two pathway sections WGINTSPLBL Intersection splice connector quickly joins Wyr Grid Pathways 1 10 WGSPL2430BL at all intersections A thread cutting screw pierces the paint of perpendicul
17. ories Inc is an independent not for profit safety testing and certification organization based in the United States NEMA National Electrical Manufacturers Association NEMA provides a forum for the standardization of electrical equipment enabling consumers to select from a range of safe effective and compatible electrical products CSA Canadian Standards Association Canadian Standards Association is a not for profit membership based association serving business industry government and consumers in Canada and the global marketplace CSA works in Canada and around the world to develop standards that enhance public safety and health International Electrotechnical Commission The IEC is the world s leading organization that prepares and publishes International Standards for all electrical electronic and related technologies collectively known as electrotechnology RoHS Compliance for CE Marking European Conformity is under evaluation Wyr Grid Design Tools Figure 2 Transverse Deflection Schematic of Cable Tray End View UL Classified as an Equipment Grounding Conductor Classification to this standard provides a 100 maximum fuse ampere rating circuit breaker ampere trip setting or circuit breaker protective relay ampere trip setting for ground fault protection of any cable circuit within the cable tray system This system provides a bolted mechanical bond between system components eliminating the need
18. ort FiberRunner 4x4 and 6x4 Channel above or below the Wyr Grid 12 Pathway using the same 1 2 or 12mm threaded rod used to support the WGTB12BL bracket Hardware for attaching to threaded rod sold separately see page 13 Available in black powder coat only FRTBWG18BL FiberRunner QuikLock Threaded Rod Trapeze Bracket for 1 10 Wyr Grid 18 457mm width Used to support FiberRunner 4x4 6x4 and 12x4 Channel above or below the Wyr Grid 18 Pathway using the same 1 2 or 12mm threaded rod used to support the WGTB18BL bracket Hardware for attaching to threaded rod sold separately see page 13 Available in black powder coat only FRTBWG24BL FiberRunner QuikLock Threaded Rod Trapeze Bracket for 1 10 Wyr Grid 24 610mm width Used to support FiberRunner 4x4 6x4 and 12x4 Channel above or below the Wyr Grid 24 Pathway using the same 1 2 or 12mm threaded rod used to support the WGTB24BL bracket Hardware for attaching to threaded rod sold separately see page 13 Available in black powder coat only FRTBWG30BL FiberRunner QuikLock Threaded Rod Trapeze Bracket for 1 10 Wyr Grid 30 762mm width Used to support FiberRunner 4x4 6x4 12x4 and 24x4 Channel above or below the Wyr Grid 30 Pathway using the same 1 2 or 12mm threaded rod used to support i na the WGTB30BL bracket Hardware for attaching to threaded rod sold FRTBWG24BL z Sq separately see page 13 Available in black powder coat only
19. quirements for load rating are much more representative to what will be encountered in the field The Wyr Grid Pathway is unique in that the load rating is not dependent on the height of a sidewall The optional sidewalls on the Wyr Grid System are simply intended to retain cables where and when required They do not contribute to the overall strength of the Traditional Wire Basket product The sidewall height and pathway width on traditional wire basket systems determine Sidewall Removal Required its load carrying capacity These systems require the sidewall to be removed when creating tee intersections and cross intersections drastically reducing the overall strength of the pathway The Wyr Grid System does not require sidewall removal when creating intersections therefore the overall strength of the pathway is not compromised The Wyr Grid Pathway System has been engineered and tested to support loads that greatly exceed its cable carrying capacity Table 2 provides an example of the practical loads that will be encountered when the pathway is filled to its capacity utilizing common data cables Identification of the Wyr Grid Overhead Cable Tray Routing System load rating was obtained through testing protocol according to EN 61537 2007 The load rating for the system is identified as the Safe Working Load SWL as shown in Table 2 The SWL is an evenly distributed load at which the midspan deflection of the cable tray is less than 1
20. s require no hardware or tools for installation The sidewalls are available in three heights 2 50mm 4 102mm and 6 152mm spat Increase pathway capacity as your network grows by using taller sidewalls There is no need to install an entirely new pathway LALALA LALALALA GHEOCCEEHEOS SOCOHSCEHOSOE 6 visit www panduit com datacenter Trapeze brackets are supplied with integral slide clips for securing the pathway in place eliminating loose hardware In addition trapeze bracket design allows side to side pathway positioning increasing installation adjustability Seamless Integration of Wyr Grid and FiberRunner Systems Brackets allow FiberRunner 4x4 6x4 12x4 and 24x4 Pathways to be supported at any height above or below the Wyr Grid System This installation utilizes the same threaded rod to support both systems Brackets allow FiberRunner 4x4 and 6x4 Pathways to be supported at a fixed height above the Wyr Grid System This minimizes the need for additional threaded rod to support the fiber pathway PANDUIT Specifications Wyr Grid Overhead Cable Tray Routing System Wyr Grid Pathways e Pathways are provided in five widths 8 203mm 12 305mm 18 457mm 24 610mm and 30 762mm Part Number WG8BL10 WG12BL10 WG18BL10 WG24BL10 WG30BL10 WG30BL10 8 visit www panduit com e Standard finishes are blac
21. t The Wyr Grid Overhead Cable Tray Routing System has been proven to reduce labor costs by 50 when benchmarked against existing wire basket and ladder rack systems strong The Wyr Grid Overhead Cable Tray Routing System has been validated through both analytical and physical testing to meet industry standards for allowable deflection Simple The Wyr Grid Overhead Cable Tray Routing System reduces the number of individual components and labor required to create common connections Fewer components and less labor equal a simpler installation Installation Time em T S Wyr Grid System ele et re ge In a high density application a fully loaded 24 wide Wyr Grid Pathway will need to support 50 Ibs ft of cable E Time I rt C C Wire Basket Ladder Rack ake ie eet The 24 wide Wyr Grid Pathway was tested to 92 Ibs ft with less than 600 of deflection per IEC 61537 See page 14 for further information The Wyr Grid System has been tested to ensure that it will support cable loads in excess of typical applications Tee Intersection with Bend Radius and Sidewalls Number of Components Wyr Grid System Wire Basket Ladder Rack Typical Wyr Grid Overhead Cable Tray System Data Center Application The Wyr Grid System is configured to route and protect cabling between the Main Distribution Area MDA or Horizontal Distribution Area HDA and the
22. the Panduit Wyr Grid Overhead Cable Tray Routing System provides a true advantage It is designed and engineered to assemble in significantly less time than other wire basket and ladder rack systems It will save you valuable time Robust Construction and Support In today s typical build out every project needs a secure platform that can support and protect the cabling infrastructure So it is important that the cable routing pathways are strong enough to support the cable loads that will be encountered today and in the future The Panduit Wyr Grid Overhead Cable Tray Routing System has been designed and tested to comply with industry standards to provide the necessary load bearing strength In addition Wyr Grid Pathways offer a greater strength to weight ratio compared to other wire basket systems This advantage will provide you with a robust cable support structure Easy to Work With Every project has complications and issues that unexpectedly arise and need to be resolved It is important that the infrastructure components do not add to this confusion via large part number lists and difficult to understand assemblies This is another advantage of the Panduit Wyr Grid Overhead Cable Tray Routing System A focused product offering with minimal components along with design tools allows specifiers to quickly understand and identify the necessary parts and create accurate bills of materials It will simplify your project Fas
23. trol and can be installed without cutting or fabrication at tees crosses and right angle intersections For electro zinc finish replace BL Black with EZ Wyr Grid Hardware WGHRDWKTBL _ The hardware kit is used when field fabricating a right angle 1 10 allowing large radii to be created by cutting the pathway bending it and securing it into a right angle 12 305mm width requires 6 pieces to create a 15 8 radius 18 457mm width requires 9 pieces to create a 24 4 radius 24 610mm width requires 12 pieces to create a 33 4 radius 30 762mm width requires 15 pieces to create a 41 5 radius Available in BL Black only GACB brackets provide a convenient location to attach ground wire for grounding Wyr Grid System to the ground bar GACEB brackets provide the flexibility to install grounding conductors above or below the Wyr Grid System Std Ctn Part Number Part Description Qty Grounding Cable Hanger Brackets l GACB 2 Supports grounding conductors positioned below Wyr Grid Pathways 1 and automatically makes bonding connection Used with ladder rack and wire basket GACB 3 GACB 3 Supports grounding conductors positioned above Wyr Grid Pathways 1 and automatically makes bonding connection Used with ladder rack and wire basket RCA fh GACBJ6 U 6 AWG grounding jumper with 2 hole copper compression connectors E Used to bond Wyr Grid to Telecommunications Groundin
24. ww panduit com datacenter Reduce Installation Costs Maximize Cable Protection Data centers are mission critical facilities and the nerve center of successful business operations AS more businesses are adopting consolidation virtualization and automation of networking assets a silo based approach to designing deploying and managing the physical infrastructure is becoming increasingly inadequate With data centers evolving to meet the challenges of complex architectures new technologies and increasing performance requirements a robust physical infrastructure is needed to provide operational benefits to drive business results Cable management is a key consideration of the physical infrastructure for optimizing system reliability effective space utilization and scalability Panduit offers industry leading Cable Routing Systems as part of comprehensive integrated Data Center Solutions to effectively manage and protect high performance communication computing and power cables Panduit s Wyr Grid Overhead Cable Tray Routing System contributes to effective real estate usage and network performance It provides speed of deployment structural integrity cable protection and ease of use Quick to Install In today s fast paced environment every project is on a tight schedule and needs to be completed NOW So it is important that infrastructure components can be installed quickly and with as little delay as possible That is where