Home

CDA EVP121

image

Contents

1. BROWN LIVE FUSED SPUR OUTLET As the colours of the wires in the mains lead for the appliance may not correspond withthecolouredmarkingsidentifyingthe terminals connecting to the fused spur proceed as follows The wire which is coloured blue must be connected to the terminal marked N Neutral or coloured black The wire which is coloured brown must be connected to the terminal marked L Live or coloured red NOTE USE A 3A FUSE USE A 3 AMP FUSE Assembly and electrical connection should be carried out by competent personnel When installing this product we recommend you seek the help of another individual IMPORTANT THIS APPLIANCE IS A CLASS II APPLIANCE DOUBLE INSULATED AND IS NOT INTENDED TO BE EARTHED DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR Do not mount the isolation switch behind the chimney section It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur and is intended to be protected by a 3A fuse The use of a 13A fuse can cause damage to the internal wiring in the event of a fault and may also invalidate the warranty Electrical Information Mains electrical voltage 230 240Vac 50Hz Total rated power consumption 290W Troubleshooting If your extractor is not working 1 Check that the mains supply has not been swi
2. EVP6 61 9 91 10 12 Extractors CDA Manual for Installation Use and Maintenance Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect Please note that the manufacturer reserves the right to invalidate the guarantee supplie installation or misuse of the appliance or use in a commercial environment This appliance is not designed to be used by people including children with reduced p who lack experience or knowledge about it unless they have had supervision or instru someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or mainte personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist CDA C your appliance and to register your appliance for guarantee purposes CE Declarations of Conformity This appliance has been manufactured to the strictest standards and complies with all app Electrical safety LVD and Electromagnetic interference compatibility EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANC 2002 96 EC At the end of its working life the product must be taken to a special local authority was providing appliance recycling services Disposing ofahouseholdappliance separately avo the environment and health It also enables the constituent materials to be recovered s reminder of the need to dispose of household app
3. e function which runs for ten minutes befi speed To activate the intensive function touch key D at speed three The display wi intensive function is on The timer The extractor is equipped with a timer that allows the extractor to run for 15 minute To activate the timer touch key E The display will flash a decimal point when the ti Please note The timer cannot be activated when the intensive function is on The clean air function The extractor is equipped with a clean air function that switches on the motor for te Toactivate the clean air function touch key E for two seconds when the appliance is d either key B or D To switch off the clean air function touch key E The display C will running and will show the letter C during the fifty minutes when the motor is not r Care and Maintenance IMPORTANT DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY Cleaning You should use a nonabrasive cleaner Any abrasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth Cleaning the grease filter The grease filters should be kept clean to minimise the risk of fire When the display flashes alternating the speed selected with the letter A or at least once a month you should r
4. emove and clean the grease filters with hot soapy water You can also wash the grease filters in a dishwasher ensuring that you place it in an upright position to prevent damage from other items in the dishwasher After rinsing and drying replace the filters After the grease filters has been replaced the electronic memory must be reset by touching key A for approximately five seconds until the letter A stops flashing To remove the grease filters follow the steps below 1 Open the stainless steel cover panels by pulling them downward from the centre They will hinge to the sides 2 Pull open the handle on the grease filter as shown in fig 2 It will release at the handle side 3 Then lower the grease filter to remove it completely To replace the grease filters repeat the steps in reverse Please note Cleaning the grease filter in the dishwasher may lead to discolouration This is normal and does not constitute a fault with the appliance Changing the charcoal filter re circulating only When the display flashes alternating the speed selected with the letter F the charcoal filters must be replaced After the charcoal filter has been replaced the electronic memory must be reset by touching key A for approximately five seconds until the letter F stops flashing To attach a new charcoal filter first open the cover panels and the filters as described above Then offer up the charcoal filter to the side of the motor as shown in fi
5. gure 3 and turn it clockwise until it locks into place Repeat with the other charcoal filter on the other side of the motor Then replace the grease filters and cover panels Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT ALLOW IT TO COOL BEFORE REMOVING IT Unscrew the light bulb cover please see figure 4 Unscrew the light bulb and replace with a 12V 20W halogen light bulb Finally replace the light bulb cover Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights The light is designed for use during cooking and not for general room illumination Extended use of the light can reduce the life span of the bulb Bulb replacement is not covered by the guarantee Only use bulbs recommended for your extractor Do not fit bulbs of a higher power rating Bulbs of a lower power rating may be adequate for use generally last longer and use less energy Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C and who will comply with the I E E and local regulations The wires in the mains lead of this appliance are coloured in accordance with the following code DOUBLE POLE SWITCHED BLUE NEUTRAL
6. height of the hood holes should take into account the minimum height specified in the instructions 2 Fit 6 wall plugs appropriate for the wall type into the drilled holes and fix two screws to the wall at positions A and leave approximately 5mm protruding 3 Hang the hood and secure screws A Fix the hood in position using 4 screws through the remaining mounting holes shown Mounting the Chimney Section 1 Adjust the width of the mounting bracket to suit the chimney size of your extractor and mark 2 points on the wall 20mm down from the ceiling for the fixings fig 7 2 Drill and insert 2 plugs suitable for use with the wall type into the holes and fix the bracket with 2 screws 3 Fit the chimney section and secure to the mounting bracket with the supplied screws fig 8 10 Attribute Symbol Model Identification fevp61 91 evpiovi21 Time increase factor fa ia it or a ra Measured airflow at Best Efficiency Qpep 347 6 eae Point Measured Pressure at Best Efficiency 243 5 261 0 om oe ee o a A Efficiency Point Average illumination of the lighting Emiddle 200 0 200 0 Lux cll ll all al al standby ee T E mode Grease Filter Efficiency 73 D 74 D Lamp efficiency 5 F 5 F CDA To contact our Customer Care Department or for Service please contact us on the details below
7. liances separately the product is ma dustbin X Please note Under no circumstances should the extractor be connected to any gas ventilation s ducting system Do not vent the extractor into an attic or loft space Only house the extractor in rooms with adequate ventilation Remember that the e extracted needs to be replaced Donot tile the extractor in It should be removable for service or maintenance Donot use silicone sealant to secure the hood to the wall You must be able to isolate the extractor from the mains electrical supply after insta Steam cleaners must not be used when cleaning this appliance The performance of your extractor will vary depending on a number of factors Thes ducting room volume ventilation available and cleanliness of the filters Using your Extractor For best performance you should switch on the extractor 15 minutes before starting to co 15 minutes after the end of cooking Control Panel A Light key B Decrease speed key C Display D Increase speed key E Timer key To switch the extractor light on and off Touch key A To switch on the extractor Touch either key B or D The appliance will switch on at the first speed To increase the speed touch key D To switch the extractor off touch and hold key B for two seconds when the extracto key B at speed one The intensive function The extractor is equipped with an intensiv
8. tched off 2 Check that the fuse in the spur has not blown Mounting your Extractor When the extractor is to be installed above an electric hob the minimum distance between the hob and extractor must exceed 600mm 650mm is recommended When the extractor is to be installed above a gas hob the minimum distance between the hob and extractor must exceed 700mm 750mm is recommended If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 700mm then that is the distance that should be observed this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm The width of any hob must not be greater than the width of the extractor installed above it Fig 5 Ducting and Ventilation For best performance and lowest noise output we recommend the use of 125mm or 150mm ducting You can also use 100mm ducting but this will reduce performance Gas 750mm recommended Electric 650mm recommended Installation The extractor is mounted to the wall using 6 plugs and fixing screws see figure 6 1 Mark the wall with the positions of the fixing holes at the required height The