Sencor SAC MT7011C
Contents
1. Control panel with LED display Air exhaust openings Horizontal flaps for manual adjustment of the airflow direction Removable air filter Wheels Vertical flaps Remote control signal receiver Exhaust air outlet Integrated handle Wound up power cord holders Condensate drain hole with plug Power cord 5 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SACMT9011C DESCRIPTION OF ACCESSORIES Connector for connecting the flexible hose to the air conditioning unit Flexible air exhaust hose Connector for the installation of the flexible hose in a window Suction cups Wheel stoppers Remote control with batteries 2 pcs Sliding window attachment with adjustable length Condensate drain hose ODODOOBDOBA 6 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C DESCRIPTION OF THE CONTROL PANEL SWING touch button It is used to activate the automatic movement of the vertical flaps A or to deactivate it Touch button v It serves to set the temperature in the range from 18 to 32 C cooling mode 13 27 C heating mode or the automatic start or shut off time in the range from 0 5 to 24 hours in the timer setting mode MODE touch button It serves to select the operat
2. 20 INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED 21 DISPOSAL OP USED BATTERIE S alko orl 21 DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT 21 EN 2 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C IMPORTANT SAFETY INSTRUCTIONS e This appliance may be used by children 8 years of age and older and by persons with physical or mental impairments or by inexperienced persons if they are properly supervised or have been informed about how to use of the product in a safe manner and understand the potential dangers Do not allow children to play with the appliance Cleaning and maintenance must not be performed by unsupervised children Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND STORE THEM FOR FUTURE USE This appliance is designed for use in households offices and similar types of areas e Do not use the appliance in very humid rooms such as laundries or bathrooms in areas where flammable chemicals are stored in industrial surroundings or outdoors Donot place the appliance in the vicinity of an open flame or appliances that are sources of heat lt Always install the appliance on an even dry and stable
3. must be closed or the condensate drain hose B must be connected to it e The air conditioning unit will start producing hot air within several minutes The fan may run for a short time even after the set temperature is achieved f the air conditioning unit is operating in the heating mode in very low ambient temperature automatic defrosting occurs While the air conditioning unit is defrosting the heating operating mode is interrupted for a short time and 89 is shown on the display The sound made by the air conditioning unit may change during the defrosting procedure After the defrosting procedure is complete the set operating mode will be resumed Note D This mode is not available on models SAC MT7011C SAC MT9011C without a heat pump 2 5 1O mode automatic e Repeatedly press the MODE C button until the 10 symbol appears on the display of the air conditioning unit set the lO operating mode the air conditioning unit will automatically select the cooling fan or heating operation e In the IQ mode it is not possible to set the temperature The fan speed can be regulated using the FAN C button e In this mode the flexible hose C must be installed and the condensate drain outlet must be closed Note D This mode is not available on models SAC MT7011C SAC MT9011C without a heat pump SWING function automatic movement of the vertical flaps e To activate the automatic movement of the vert
4. 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C DESCRIPTION OF THE REMOTE CONTROL CONTINUED Signal transmitter SLEEP function indicator If the SLEEP function is activated the indicator will be shown next to the symbol Operating mode indicator It appears next to the respective symbol depending on the operating mode setting cooling gt dehumidification fan heating X or automatic 0 Temperature display The set temperature is shown on the display In the automatic start or shut off timer setting mode the time is shown the display of the remote control TIMER button It is used to activate the automatic start or shut off timer to deactivate it or to cancel it SLEEP button It is used to set the sleep function MODE button It serves to select the operating mode cooling gt dehumidification gt fan gt heating gt IO automatic The operating mode setting is signalled by the display of the an indicator next to the respective symbol Automatic start shut off timer indicator It is shown next to the symbol or when the timer is activated Fan speed indicator It shows the set fan speed on a scale that is located on the right next to the remote control display SWING function indicator It is shown on the display when the automatic vertical flap movement is activated A button It serves to set the temperature in the range from 18 to 32 C
5. SAC 7 1 SAC MT9011C TECHNICAL SPECIFICATIONS Model Power source Cooling power output Power input Current consumption EER cooling factor Dehumidification capacity Capacity of the built in condensate tank Coolant type and weight Air flow volume Noise level Maximum permitted value of excess operating pressure Suction exhaust part of the cooling circuit Dimensions of the air conditioning unit w xd x h Dimensions of the packaging w x d x h Weight net gross Operating temperature Cooling mode Recommended room area 1 2 1 4 2 MPa 2 1 4 2 MPa 270 480 695 mm 270 480 x 695 mm 335 x 540 x 880mm 335 540 x 880 mm 23 8 27 4 kg 28 3 31 9 kg 18 35 C 18 35 C 10 18 m 14 21 m The declared noise emission level of the appliance SAC MT7011C SAC MT9011C is 53 54 dB A which represents level A of acoustic power with respect to a reference acoustic power of 1 pW Note D The efficiency of the air conditioning unit may be reduced in the event that it is used outside the above described operating temperature range We reserve the right to change text and technical specifications 20 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC 7 1 SAC MT9011C INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING Dispose of packaging material at a public waste disposal site DISPOSAL OF USED BATTERIES B
6. e If the air conditioning unit is running press the TIMER DG once to activate the automatic shut off mode The indicator D will be lit on the display of the remote control next to the symbol The symbol is flashing at the time value The C symbol is shown on the display of the air conditioning unit To set time in the range 0 5 to 24 h use the 003 and 00 buttons In the time interval from 0 5 to 10 h the timer settings change in 30 minute increments from 10 to 24 h the timer settings change in 1 h increments Confirm the set time by pressing the TIMER DG button again Once the set time has elapsed the air conditioning unit will turn itself off If you wish to cancel the timer setting before the set time has elapsed press the TIMER D button once more If the air conditioning unit is off press the TIMER DG button twice to activate the automatic start mode The indicator D will be lit on the display of the remote control next to the symbol The h symbol is flashing at the time value The C4 symbol is shown on the display of the air conditioning unit To set time in the range 0 5 to 24 h use the 003 and 00 buttons In the time interval from 0 5 to 10 h the timer settings change in 30 minute increments from 10 to 24 h the timer settings change in 1 h increments Confirm the set time by pressing the TIMER DG button again Once the set time has elapsed the air conditioning unit will turn itself on If you wish to cancel the ti
7. or in the heating mode where the self evaporation system is not automatically activated For such situations the air conditioner is equipped with a condensate drain outlet and a self diagnostic system which will inform you that the tank is full When the water tank fills up the set operating mode will stop automatically It will resume only after the condensate has been drained Note n The heating mode is not available on models without a heat pump A Draining the condensate when the water tank is full or at the end of a season If the level of the condensate in the built in water tank reaches the maximum level the error message will appear on the display of the air conditioning unit The air conditioning unit will stop automatically Turn off the air conditioning unit Wait several minutes and disconnect it from the el power socket If the flexible hose BO is installed disconnect it and move the air conditioning unit to a location where the condensate may be drained Take off the condensate drain outlet plug AG Allow the condensate to drain out If no condensate flows from the outlet tilt the air conditioning unit slightly to allow the water tank to drain fully Then reattach the plug to the drain outlet A Reinstall the unit in its location and if necessary put it back into operation Note R j For the purpose of draining the condensate the drain hose BG may be used B Continuous draining of condensate e Inthe heating mo
8. sunlight or high temperatures Otherwise the signal may not be transmitted EN 15 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C 2 1 Turning the air conditioning unit on and off e To turn on the air conditioning unit press the DA button once When it is first started the cooling mode is set automatically When it is started again the mode that was activated previously is automatically resumed e To turn off the air conditioning unit press the D button once more The air conditioning unit will switch to stand by mode 2 2 Setting the operating mode 2 2 1 Cooling mode e Press the MODE DG mode repeatedly until the operating mode indicator DG appears next to the symbol The same symbol will light up on the display of the air conditioning unit set temperatures in the range 18 32 C use the 049 and 049 buttons The set temperature will be shown both on the display of the remote control and on the display of the air conditioning unit e the fan speed using the FAN 009 button Set the fan speed by repeatedly pressing the FAN D button as follows low gt medium gt high gt automatic The fan speed is shown by the respective indicator on the display of the remote control The fan speed is also shown on the display of the air conditioning unit 2 2 2 Dehumidification mode 6 e the MODE DG mode repeatedly until the operating mode indicat
9. surface The appliance is equipped with travel wheels so pay extra attention when handling it so that it does not fall down stairs or travel down from sloped areas If necessary secure the wheels using the supplied stoppers e Before connecting the appliance to a power socket check that the technical details on the appliance s rating label match the electrical voltage in the socket e Connect the appliance only to a grounded power socket Do not use an extension cable to connect the appliance to a power socket The power socket to which you connect the appliance must be freely accessible so that it is possible to quickly disconnect it from the power source if necessary e Do not touch the appliance that is connected to a power socket with wet hands Do not spray the appliance with water or any other liquid or submerge it in water or any another liquid e Do not cover or insert anything into the air inlet or air outlet openings Otherwise this could damage the appliance e During operation there needs to be sufficient space for air circulation of at least 30 cm on all sides of the appliance Do not expose yourself to a cold air current for a long time This could have a negative effect on your health To turn the appliance on or off always use the appropriate buttons on the control panel or the remote control Do not turn off the appliance by disconnecting the power cord from the power socket e Always turn off the appliance and d
10. 4 2 Cleaning the outer case of the air conditioning unit e Toclean the outer case of the air conditioning unit use a soft wiping cloth dipped in a solution of lukewarm water and neutral detergent Then wipe the surface of the air conditioning unit dry e When cleaning do not spray the air conditioning unit with water or pour water on it or submerge it in water not use abrasive cleaning products solvents petrol etc for cleaning 3 Before putting the air conditioning unit out of operation for an extended period of time or before putting it into operation e Disconnect the flexible hose Store it in a safe place out of the reach of children e Drain all the condensate from the built in water tank as described in chapter Condensate drain outlet e Clean the air filters and reattach them to the air conditioning unit Wipe the outer case of the air conditioning unit and take the batteries out of the remote control Before putting the air conditioning unit into operation again after a long time of inactivity check that the power cord does not exhibit signs of damage and that the air filters A are clean Install the batteries into the remote control B according to the instructions in chapter Remote control Install the air conditioning unit in accordance with the instructions in chapter Installing the portable air conditioner EN 19 Copyright 2014 Fast R a s Revision 01 2014 Portable Conditioner
11. Portable Air Conditioner User s manual SENCOR SENCOR SAC MT 011C SAC MT9011C Prior to using this appliance please read the user s manual thoroughly even in cases when one has already familiarised themselves with previous use of similar types of appliances Use the appliance only as described in this manual Keep this manual for later use Save the original shipping box packaging material purchase receipt and warranty card for the duration of the warranty In the event of shipping pack the appliance using the original packaging materials only EN 1 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SACMT9011C CONTENTS IMPORTANT SAFETYINSTRUCTIONS hlienov lil nova ah 3 DESCRIPTION OF THE PORTABLE ARGON NE K ra o ro 5 DESCRIPTION OF TRE ACCESS OA E Boss to ko osla dia kan ZO Oravu 6 DESCRIPTION OF THE CONTROL PANEL or rn 7 DESCRIPTION OF THE REMOTE CONTROL 8 INSTALLING THE PORTABLE AIR CONDITIONER 2 a 10 ENERGY SAVING TA Sak dn o 12 CONDENSATE DRAIN CE o 12 HOW TO CONTROL THE PORTABLE AIR CONDITONER ran 13 OPR MAR ONE O OR PNS P P MR therapeu 17 TROUBLESHOOTING BEE 18 MAINTENANCE FIN CLE NIN 19 TECHNICAL SPECTRA HONS
12. atteries contain environmentally damaging compounds and therefore do not belong in standard household waste Take the batteries to an appropriate collection point which will provide for their ecological disposal You can obtain the contact for the nearest collection point from you town council or from your retailer DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT The meaning of the symbol on the product its accessory or packaging indicates that this product shall not be treated as household waste Please dispose of this product at your applicable collection point for the recycling of electrical amp electronic equipment waste Alternatively in some states of the European Union or other European states you may return your products to your local retailer when buying an equivalent new product The correct disposal of this product will help save valuable natural resources and help in preventing the potential negative impact on the environment and human health which could be caused as a result of improper liquidation of waste Please ask your local authorities or the nearest waste collection centre for further details The improper disposal of this type of waste may fall subject to national regulations for fines For business entities in the European Union If you wish to dispose of an electrical or electronic device request the necessary information from your seller or supplier Disposal in other countries outside the European Union If you wish
13. be necessary to modify the installation procedure described below e Slide the window sash upwards and place the attachment B on to the window sill Adjust the length of the attachment BG to the width of the window Secure the set length of the attachment B using pins Close the sliding sash all the way on to the attachment B e Stretch out the flexible hose so that it is possible to attach the connector BG to the attachment BO Avoid excessive bending of the hose BQ e First connect the connector BG to the hose B and then connect it to the attachment B that is installed in the slide window EN 11 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C ENERGY SAVING TIPS e To ensure optimal efficiency of the air conditioning unit not exceed the recommended room size for which the air conditioning unit was designed see Table of technical parameters close windows and doors If necessary allow the room to ventilate for a short time close curtains or blinds if sunlight is heating the room through the window panes regularly clean the air filters CONDENSATE DRAIN OUTLET e The air conditioning unit is equipped with a self evaporative condensate system Under normal operating conditions it is not necessary to empty the built in condensate tank The water tank may fill up if the air conditioning unit is operated in a room with a high level of humidity
14. ble to set the temperature The fan speed can be regulated using the FAN 042 button Note RE This mode is not available on models SAC MT7011C SAC MT9011C without a heat pump EN 16 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C 2 3 SLEEP function e First use the MODE D button to select the cooling dehumidification or IO mode Then press the SLEEP DG button The SLEEP function indicator D will appear on the display of the remote control next to the x symbol The same symbol will light up on the display of the air conditioning unit The air conditioning unit will continue running in the set mode however the fan speed will drop to minimum After 2 hours of operation in the SLEEP mode the set temperature will automatically increase by 1 C and after another hour it will again increase by 1 C Thereafter the air conditioning unit will maintain this temperature Note R j The SLEEP button DG will not work in the fan and heating mode 2 4 SWING function automatic movement of the vertical flaps e To activate the automatic movement of the vertical flaps from left to right press the SWING 009 button once The SWING function indicator D will appear on the display e To deactivate the automatic movement of the vertical flaps press the SWING D 3 button once more The SWING function indicator D 9 will turn off 2 5 Setting the automatic start shut off timer
15. cooling mode 13 27 C heating mode or the automatic start or shut off time in the range from 0 5 to 24 hours in the timer setting mode FAN button It serves to set the fan speed low gt medium gt high gt automatic speed SWING button It is used to activate the automatic movement of the vertical flaps A or to deactivate it button It is used to turn the air conditioning unit on or off to the stand by mode v button It serves to set the temperature the range from 18 to 32 C cooling mode 13 27 C heating mode or the automatic start or shut off time in the range from 0 5 to 24 hours in the timer setting mode A 80 Note This mode is not available on models SAC MT7011C SAC MT9011C without a heat pump Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C INSTALLING THE PORTABLE AIR CONDITIONER 1 Selecting the installation location for the air conditioning unit Locate the air conditioning unit on an even dry and stable surface and within reach of a grounded power socket optimal efficiency keep the air conditioning unit at least 30 cm away from the wall or other obstacles Note D Do not use the air conditioning unit to cool a room with computer servers etc 2 Installing the flexible hose e The flexible hose BE must be connected to the air conditioning unit and insta
16. de the operation of the system does not have self evaporation of the condensate and so we recommend using continuous draining of condensate Remove the plug of the condensate drain outlet and connect the drain hose BG to it Check that the hose BG is securely attached to the drain outlet AG so that condensate does not leak out at the connection point Locate the other end of the hose B so that the condensate can flow out freely The hose B 8 must not be installed above the condensate drain outlet and must not be excessively bent EN 12 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT 011C SAC MT9011C D Note The heating mode is not available on models without a heat pump HOW TO CONTROL THE PORTABLE AIR CONDITIONER Control panel AG and remote control B are used to control the air conditioning unit Buttons for setting the basic functions of the air conditioning unit are located on control panel The remote control B is used for full control of the air conditioning unit Insert the power plug into an electrical power socket The connection to a working power socket is indicated by a sound and by all the elements on the display of the air conditioning unit being briefly shown Then the display shows indicating that the air conditioning unit is in the stand by mode Control panel Turning the air conditioning unit on and off To turn on
17. ical flaps from left to right press the SWING button once e To deactivate the automatic movement of the vertical flaps press the SWING C button once more B Remote control Inserting and replacing batteries e Slide out the battery compartment cover which is located on the rear side of the remote control B 6 Place two AAA LRO3 2 x 1 5 V alkaline batteries into the battery compartment and close the cover e When inserting the batteries ensure the correct polarity as shown in the battery compartment e When replacing batteries do not combine old and new batteries or batteries of various types Note D Taking the batteries out of the remote control will delete all the settings After new batteries are inserted the default remote control setting as programmed by the manufacturer will be renewed e lfyouwill not be using the remote control for longer than 3 months remove the batteries 2 Using remote control e For proper operation of the air conditioning unit the distance from the remote control B to the air conditioning unit must not be greater than 7 m and there must not be any obstacles in the direction of the signal The remote control B must be pointed in the direction of the signal receiver AG located on the air conditioning unit The reception of the signal by the air conditioning unit is confirmed by a sound e Do expose the remote control or the signal receiver on the air conditioning unit to direct
18. ing mode cooling t gt dehumidification gt fan 88 gt heating X gt IO automatic LED display Displays the temperature fan speed operating mode and the automatic start or shut off timer indicator Indicator Signals the cooling operating mode setting Indicator 6 Signals the dehumidification operating mode setting Indicator 3 Signals the fan operating mode setting Indicator lt lt Signals the heating operating mode Indicator 10 Signals the IO operating mode automatic mode setting Indicator Signals the SLEEP function setting Indicator 37 The fan speed is shown on a scale Indicator Signals the automatic start shut off timer setting Touch button It is used to turn the air conditioning unit on or off to the stand by mode Touch button 4 It serves to set the temperature in the range from 18 to 32 C cooling mode 13 27 C heating mode or the automatic start or shut off time in the range from 0 5 to 24 hours in the timer setting mode FAN touch button It serves to set the fan speed low gt medium gt high gt automatic speed Note This mode is not available on models SAC MT7011C SAC MT9011C without a heat pump Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C DESCRIPTION OF THE REMOTE CONTROL EN 8 Copyright
19. isconnect it from the power socket before installing or removing accessories if you will not be using it or before cleaning it Donot attempt to remove the outer case of the appliance Do disconnect the appliance from the power socket by pulling on the power cord This could damage the power cord or the power socket Disconnect the cord from the power socket by gently pulling out the plug of the power cord e It is forbidden to use the appliance if it has a damaged power cord or plug If the power cord is damaged have it replaced at a professional service centre e Store the appliance in a vertical position It may be transported in a vertical position or tilted to one side If you have already used the appliance first check that all the condensate has been drained If you have transported the appliance wait at least 1 hour before putting it into operation use the appliance if it is not working correctly if it has been damaged or has been submerged in water To avoid the danger of injury by electrical shock do not repair the appliance yourself or make any adjustments to it Have all repairs or adjustments of the appliance performed at an authorised service centre Tampering with the appliance during the warranty period may void the warranty policy EN 4 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC 7011 SAC MT9011C DESCRIPTION OF THE PORTABLE AIR CONDITIONER
20. itioning unit is not connected to an el power socket A protective function was activated The flexible hose B is excessively bent The air outlet is blocked by foreign objects There are open windows or open doors in the room There are heat sources inside the room The flexible hose B is not properly installed or is blocked The set temperature is too high The temperature in the air conditioned room does not conform to the operating conditions for which the air conditioning unit is designed Air filters A are clogged with dust The air conditioning unit is not located on an even and stable surface This is a function of the compressor The air conditioning unit identified a problem by means of the self diagnosis system SOLUTION Plug the power cord of the air conditioning unit into an el power socket Wait 30 minutes If the problem persists contact an authorised service centre Remove the bends on the flexible hose B and set its length to be as short as possible Check the air outlet hole A 8 and the flexible hose B and remove foreign objects blocking the air outlet Close the doors and windows in the room If possible remove all heat sources from the room Properly install the flexible hose BO according to the instructions in chapter Installing the portable air conditioner Remove objects blocking the air outlet A 8 or the flexible hose BO Lower the set temperat
21. lled into window in accordance with the operating mode that you wish to set Operating mode Use of the flexible hose B Cooling dehumidification heating or automatic YES Fan NO Note D The heating mode is not available on models without a heat pump 2 1 Connecting the flexible hose to the air conditioning unit First connect the flexible hose B to connector BG and then secure to the hole in the air exhaust 2 2 Installing the flexible hose into window e Itis necessary to install the end of the flexible hose B into window Install according to the instructions below EN 10 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C A Installing the flexible hose into a window opening to the left or right e the loose end of the flexible hose B attach connector B e Open the window Stretch out the flexible hose B so that it is possible to place connector BG into the window Avoid excessive bending of the hose BO e Place the connector BG into the window and close the window to the width of the connector BG To ensure that the window remains closed secure it in place using the supplied suction cups BG see figure B Installing the flexible hose into a vertical slide window e attachment B is designed to be compatible with most standard vertical slide windows Nonetheless for certain types of slide windows it may
22. mer setting before the set time has elapsed press the TIMER DG button once more SELF DIAGNOSIS The air conditioning unit is equipped with a self diagnosis system If an error message appears on the display follow the instructions in the table below Error message Solution Protection of the compressor L Frost protection of compressor was activated As soon as defrosting process is complete the initially set operating mode will be resumed Sensor error A Contact an authorised service centre The built in condensate tank is full Drain the condensate from the tank according to the instructions in chapter Condensate drain outlet 17 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SACMT9011C TROUBLESHOOTING TABLE PROBLEM ERROR MESSAGE The air conditioning unit does not start when the button is pressed The air conditioning unit works in the cooling dehumidification heating or IO mode for only a short time The cooling performance of the air conditioning unit is not sufficient An odour can smelled when the air conditioning unit is running During the operation of the air conditioning unit noise can be heard and vibrations are felt After restarting the air conditioning unit its operation is resumed after approximately 3 minutes An error message appears on the display POSSIBLE CAUSE The air cond
23. or DG appears next to the symbol The same symbol will light up on the display of the air conditioning unit e Inthe dehumidification mode it is not possible to set the fan speed or temperature 2 2 3 Fan mode 35 e the MODE DG mode repeatedly until the operating mode indicator DG appears next to the 3 symbol The same symbol will light up on the display of the air conditioning unit Use the FAN D 2 button to set the fan speed Note D In this mode it is not possible to set the automatic fan speed e Inthe fan mode it is not possible to set the temperature Only the fan is running 2 2 4 Heating mode lt lt e Press the MODE mode repeatedly until the operating mode indicator DG appears next to the 25 symbol The same symbol will light up on the display of the air conditioning unit To set temperatures in the range 13 27 C use the 009 and D buttons e Inthe heating mode the fan speed is set automatically and cannot be regulated Note R This mode is not available on models SAC MT7011C SAC MT9011C without a heat pump 2 2 5 IQ mode automatic e Press the MODE D mode repeatedly until the operating mode indicator DG appears next to the 14 symbol The same symbol will light up on the display of the air conditioning unit e If you set the IQ operating mode the air conditioning unit will automatically select the cooling fan or heating operation e Inthe IQ mode it is not possi
24. the air conditioning unit press the button once When it is first started the cooling mode is set automatically When it is started again the mode that was activated previously is automatically resumed To turn off the air conditioning unit press the button once more The air conditioning unit will switch to stand by mode Attention A Never turn off the air conditioning unit by disconnecting the power cord from the el power socket Always turn off the air conditioning unit using the appropriate button and wait several minutes before disconnecting the power cord from the el power socket Setting the operating mode Cooling mode Repeatedly press the MODE C button until the symbol appears on the display of the air conditioning unit To set temperatures in the range 18 32 C use the and 4 buttons Set the fan speed using the FAN button The speed of the fan is changed by repeatedly pressing the FAN 85 button There are four fan speed settings available see figure 1 EN 13 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT 011C SAC MT9011C Low speed Medium speed High speed Automatic speed The air conditioning unit will automatically set the most appropriate fan speed based on the selected temperature which is shown on the display In this mode the flexible hose B must be installed and the condensate drain outlet must be closed 2 2 Deh
25. to dispose of this product request the necessary information about the correct disposal method from local government departments or from your seller This product meets all the basic EU regulation requirements that relate to it EN 21 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C EN 22 Copyright 2014 Fast R a s Revision 01 2014
26. umidification mode 4 e Repeatedly press the MODE CB button until the symbol appears on the display of the air conditioning unit e Inthe dehumidification mode it is not possible to set the fan speed or temperature e In this mode the flexible hose must be installed to enable excess humidity to be removed from the room The condensate drain outlet must be closed 2 3 Fan mode amp e Repeatedly press the MODE C button until the 8 symbol appears on the display of the air conditioning unit e Use the FAN C 3 button to set the fan speed Low speed Medium speed Highspeed Note D In this mode it is not possible to set the automatic fan speed e Inthe mode it is not possible to set the temperature Only the fan is running e In this mode it is not necessary to install the flexible hose It is recommended to leave the condensate drain outlet AG closed although no condensate is created in this mode EN 14 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C 2 4 Heating mode lt lt e Repeatedly press the MODE C button until the 302 symbol appears on the display of the air conditioning unit To set temperatures in the range 13 27 C use the and 4 buttons e Inthe heating mode the fan speed is set automatically and cannot be regulated e In this mode the flexible hose B must be installed The condensate drain outlet
27. ure The air conditioning unit must be used under the designated operating conditions Clean out the air filters A according to the instructions contained in the chapter Maintenance and cleaning Move the air conditioning unit to an even and stable surface This is a completely normal event Proceed according to the instructions in chapter Self diagnosis EN 18 Copyright 2014 Fast R a s Revision 01 2014 Portable Air Conditioner SAC MT7011C SAC MT9011C MAINTENANCE AND CLEANING e Always turn the air conditioning unit off before cleaning Wait several minutes and then disconnect the power cord from the el power socket 1 Cleaning the air filters e Ifthe air conditioning unit is used regularly clean the air filters at least once every 14 days to avoid the fan from becoming clogged with dust e the air filters A by the strip and slide them out of the air conditioning unit e Use a vacuum cleaner to remove dust from the filters A In the event of significant soiling wash the filters by hand in a solution of lukewarm water with a temperature max 40 C and neutral detergent Then thoroughly rinse under flowing water and allow to dry naturally Do not dry it in a clothes dryer or in direct sunlight e Once the filters are dry you can install them back in their place Note D Do not use the air conditioning unit without properly installed air filters A
Download Pdf Manuals
Related Search
Related Contents
TECSUN PL-600 PL600 User Manual English Collecting and Preserving plant specimens, a manual Manual do Utilizador Agosto de 2001 Dispositivo para fijación con clips AGTC Gemini FirstMix Sharp LC-70UD1U 69.5" Full HD 3D compatibility Smart TV Wi-Fi Black, Silver Express Ethernet Switch LB9019A-R4 LB9020A-R3 Copyright © All rights reserved.