Home
TP-LINK N600
Contents
1. Clients C To deploy an EAP in your local network a DHCP server is required to assign IP addresses to the EAP and clients Typically a router acts as the DHCP server Ensure the EAPs are in the same subnet with the Controller Host in which the EAP Controller software is installed The EAP can be managed by the EAP Controller software which is a management software specially designed for the TP LINK EAP devices on a local wireless network allowing you to centrally configure and monitor mass EAP devices using a web browser on your PC The EAP can also work independently as a standalone device 01 Hardware Overview 1 LED EAP110 EAP120 and EAP220 have the same LED status and corresponding indications o J TP LINK System LED LED Status Solid green The device is working properly Flashing red System errors RAM Flash Ethernet WLAN or firmware may be malfunctioning Flashing yellow Firmware update is in progress Do not disconnect or power off the device Double flashing red green yellow The device is being reset to its factory default settings 02 2 Interface Panel EAP110 a RESET ETHERNET A ARROW 1 m EAP120 EAP220 amp RESET CONSOLE ETHERNET ON OFF POWER 4 p EE oo ARROW 1 Please note that EAP110 does not have the CONSOLE port POWER port or ON OFF button The i
2. data or to a PSE Power Sourcing Equipment such as a PoE switch for both data transmission and Power over Ethernet PoE through Ethernet cabling m Passive PoE Adapter The PoE adapter is ONLY provided with EAP110 for power supply Refer to next chapter 4 Power Supply to learn more about power supply for EAP110 Power LED Power LED The Power LED indicates the status of the electric current green 0 0 8A red 0 8A 1A POE Port This port is used to connect to the ETHERNET port of EAP110 LAN Port This port is used to connect to your LAN 04 Hardware Installation The EAP can be wall mounted or ceiling mounted Please suitably arrange your wire layout before mounting the EAP We take EAP110 as example to explain the installation EAP110 can be powered via the provided PoE adapter while EAP120 and EAP220 can be powered via a PoE switch or the provided power adapter 1 Installation Requirements Before installation check the package contents for the following items J EAP Mounting Bracket Installation Guide OSs le Ww W Plastic Wall Self tapping Pan head IRE NUES WASESA Anchors 3 Screws 3 Screws 3 Other installation equipments may require including a pencil ruler drill drill bit screwdriver and a ladder 2 Mounting Bracket The following figure describes the layout of the mounting bracket ARROW 2 is used to align with ARROW 1 under the interfa
3. 168 0 100 8043 login on other hosts in the same LAN to reach the login page of the EAP Controller Specifications HARDWARE FEATURES Model EAP110 EAP120 EAP220 Interface Kensington lock slot ETHERNET ETHERNET 10 100 1000Mbps Ethernet port RJ 10 100Mbps 45 Ethernet port RJ CONSOLE port RJ 45 45 ON OFF button Power connector DC 2 Maxi 24V 1A passive PoE PoE 802 3af compliant PoE 802 3af compliant adapter included 36 57VDC 0 2A Max 36 57VDC 0 4A Max or external 12VDC 1Ajor external 12VDC 1 5A u Antenna 2 3dBi embedded _ 2 4dBi embedded 4 4dBi embedded Mounting Ceiling Wall mounting kits included CE FCC RoHS Temperature Humidity WIRELESS FEATURES 2 4GHz 2 4GHz amp 5GHz IEEE 802 11a b g n Up to 600Mbps 2 4GHz 23dBm 5GHz 20dBm Multiple SSIDs Up to eight per radio Captive Portal Support Authentication WPA WPA2 PSK WPA WPA2 Enterprise Maximum transmission power may vary in different countries or regions 15 EAL COPYRIGHT amp TRADEMARKS Specifications are subject to change without notice TP LINK is a registered trademark of TP LINK TECHNOLOGIES CO LTD Other brands and product names are trademarks of their respective holders No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from TP LINK TECHNOLOGIES CO LTD Copyright 2015 TP LINK TECH
4. NOLOGIES CO LTD All rights reserved Website http www tp link com Tel 86 755 26504400 E mail support tp link com 7106505122 REV1 0 0
5. TP LINK Installation Guide Wireless N Access Point EAP110 EAP120 EAP220 CONTENTS Network Topology __ 01 Hardware Overview ___ 02 Hardware Installation ___ 05 1 Installation Requirements 2 MOUNTING Bracket vis ccccsiecsscscscteccececttarserassteecsuctetccedesnctvevessedeas 3 IMStAN AION sesinin anian a iaeei ia aa iaaiiai 06 4 Power SUPPLY a saiecstscecesnctia ccadertacseccensechentdesandecseaatadacdevesideye 11 Software Configuration H _ ___ 13 A _ _ ____ __ _ _ _ __ 14 Specifications _ _ ______ __ 15 About This Installation Guide This guide is designed to familiarize you with the general layout of the EAP110 EAP120 and EAP220 describe how to perform the hardware installation and how to configure the EAP Controller software in your network Your EAP has more features and functionalities which can be found in the User Guide Conventions Unless otherwise noted the EAP or the device mentioned in this guide stands for 300Mbps Wireless N Access Point EAP110 Wireless N Gigabit Access Point EAP120 and EAP220 Network Topology A typical network topology for the EAP is shown below Controller Host Switch EAP Router Controller C O OIONIO g
6. ce panel Ceiling mounting slot Wall mounting slot Locking clip 05 3 Installation m Ceiling Mounting Note Make sure the thickness of the ceiling is less than 18mm and the ceiling can bear at least five kilograms It is NOT recommended to mount the EAP on a low strength material such as gypsum ceiling panel If no other choice is available make sure you add a piece of strong material under the wing nuts to ensure the EAP is mounted solidly 1 Remove the ceiling tile 2 Place the mounting bracket in the center of the ceiling tile Mark the positions of the three mounting slots and a hole for the Ethernet cable to feed through Mark of the hole for Ethernet cable to feed through 06 3 Use a drill with the appropriate size drill bit to drill three 4mm holes for the pan head screws and drill a 10mm hole for the Ethernet cable to feed through g 4mm hole for mounting bracket 10mm hole for Ethernet cable feed 4 Secure the mounting bracket to the ceiling tile using the pan head screws washers and wing nuts as shown below Hole to feed the Ethernet cable Wing nut d 9 C Hole to feed the screw Washer P 4 ie as g Pan head screw 07 5 Attach the EAP to the mounting bracket by aligning ARROW 1 with ARROW 2 as shown below N N A ARROW 1 yy y Z 6 Turn the EAP clockwise until it locks into
7. he male connector to a power outlet 11 m EAP120 EAP220 EAP120 EAP220 can be powered via a PSE device such as a PoE switch or a power adapter Via PoE Switch PoE Switch EAP120 EAP220 OOC Oc Mood L eresse OO sesssssall e I O j 1 Connect the Ethernet cable from the PoE switch to the ETHERNET port of EAP120 EAP220 2 Press the ON OFF button on the interface panel of EAP120 EAP220 Via Power Adapter Switch Socket EAP12 20 EAP220 eem Qo Wm ge weno P i Le 1 Plug one end of the provided power adapter into the power port of EAP120 EAP220 and the other end to a standard electrical wall socket 2 Press the ON OFF button on the interface panel of EAP120 EAP220 12 Software Configuration The following content will guide you to quickly set up a wireless network connection with mass EAPs and log in to the EAP Controller management interface to manage the EAPs Controller Host EAP Switch Router Controller t PO Step 1 EAP Controller Installation Follow the step by step instructions to complete the EAP Controller installation on the Controller Host EAP Note The EAP Controller application file can be found on the resource CD or downloaded from our website http www tp link com en Refer to the EAP Controller User Guide to lea
8. nterface panel components of the EAP from left to right are described in the following list Kensington Security Slot Secure the lock not provided into the security slot to prevent the device from being stolen RESET With the device powered on press and hold the RESET button for about 8 seconds until the LED flashes red then release the button The device will restore to factory default settings CONSOLE This port is used to connect to the serial port of a computer or a terminal to check and monitor system information of EAP120 EAP220 Note CLI commands are not available in current software version We will release a new version supporting CLI commands soon Please pay close attention to our official website 03 ON OFF Press this button to turn on off the EAP120 EAP220 POWER The power port is used to connect the EAP120 EAP220 to an electrical wall outlet via power adapter Please only use the provided power adapter Refer to next chapter 4 Power Supply to learn how to power the EAP120 EAP220 via power adapter ARROW 1 This arrow is used to align with ARROW 2 on the mounting bracket to lock the EAP into place Please refer to next chapter 2 Mounting Bracket to locate ARROW 2 ETHERNET For EAP110 this port is used to connect to the POE port of the provided PoE adapter for both data transmission and power supply through Ethernet cabling For EAP120 EAP220 this port is used to connect to a router or a switch to transmit
9. place 08 7 Feed the Ethernet cable through the hole and set the ceiling tile back into place 8 Connect the Ethernet cable to the ETHERNET port m Wall Mounting There are two wall mounting slots on the back of the mounting bracket To mount the EAP on a wall please follow the steps below 1 Make two small pencil marks on the wall Make sure the two marks are level and should be 98 6mm apart 2 Use a drill with the appropriate size drill bit to drill two 4mm holes through the center of your marks Wall 4mm hole 3 Insert the plastic wall anchors into the 4mm holes and drive the self tapping screws into the anchors 09 4 Attach the EAP to the mounting bracket by aligning ARROW 1 with ARROW 2 ARROW 1 ARROW 2 6 Hang the EAP on the screws Make sure the EAP is firmly seated against the wall 7 Connect the Ethernet cable to the ETHERNET port on the EAP 10 4 Power Supply m EAP110 The EAP110 can be powered with the provided PoE adapter EAP110 Switch Up to 100m 1 Connect the ETHERNET port of EAP110 to the POE port of the PoE adapter through an Ethernet cable The cable length can be up to 100 meters 2 Connect the Ethernet cable from the switch to the LAN port of the PoE adapter 3 Plug the female connector of the power cord into the PoE adapter and t
10. rn how to perform the installation Step 2 Configuring the Controller Software Launch the EAP Controller and finish the configuration wizard to create a primary wireless network Step 3 More Configurations After the primary network is created a login screen will appear Enter the admin name and password you created and click Sign In You will be directed to the management interface in which you can perform more advanced configurations Refer to the EAP Controller User Guide to learn more advanced configurations 13 Q amp A Q1 Q2 Q3 What is the maximum cable length between the EAP110 and the provided PoE adapter 100 meters The quality of the Ethernet cable may influence the reception of the power supply Could the EAP work as a standalone device if it had been adopted by the EAP Controller No By default the EAP works as a standalone device It will function as a Managed AP once adopted by the EAP Controller You can Forget this AP on the Controller management interface to turn it back as a standalone device Can manage the EAP devices on a host without the EAP Controller server Yes Keep the EAP Controller software running on the Controller Host sign in to the EAP Controller using https x x x x 8043 login in which x x x x is the IP address of the Controller Host and 8043 is the default port number for the server For example the IP address of Controller Host is 192 168 0 100 you can enter https 192