Home

DELL C7004

image

Contents

1. Console Access The console port is an asynchronous serial port If you connect a device to these ports it must be capable of asynchronous transmission Step Task 1 Install an RJ 45 copper cable into the console port Use a rollover cable to connect the C7004 C150 or C7008 C300 console port to a terminal server 2 Connect the other end of the cable to the DTE terminal server 3 Set your terminal or terminal emulation mode to VT100 with the following settings 9600 baud rate To avoid autobaud input the default is set to a 9600 BPS No parity 8 data bits 1 stop bit Window Terminal Emulator option set to NO 24 lines X 80 characters No flow control Installing the Software 19 Cable and Adapter Pin Assignments To connect to a terminal port PC serial port or a terminal server use the console port on the RPM to configure and monitor your system An RJ 45 Ethernet cable is required to connect to the Ethernet port The console port is an RJ 45 and the pinouts are listed in Table 2 1 Table 2 1 Pin Assignments for Console Port RJ 45 Pin Signal Input Output 1 NC unused 2 DTR Output 3 TxD Output 4 GND 5 GND 6 RxD Input 7 DSR Input 8 NC unused Accessing the Console with a DB 9 Adapter You can connect to the console using an RJ 45 to RJ 45 rollover cable and an RJ 45 to DB 9 female DTE adapter labeled TERMINAL to a terminal server for example PC T
2. enable Layer 2 data transmissions through an individual interface use the switchport command in INTERFACE mode You cannot configure switching or Layer 2 protocols such as the spanning tree protocol STP on an interface unless the interface has been set to Layer 2 mode Step Task Command Syntax Command Mode 1 Enable the interface no shutdown INTERFACE 2 Place the interface in switchport INTERFACE Layer 2 switching mode To view the interfaces in Layer 2 mode use the show interfaces switchport command in EXEC mode Configure a Host Name The host name appears in the prompt The default host name is Dell e Host names must start with a letter and end with a letter or digit e Characters within the string can be letters digits and hyphens Task Command Syntax Command Mode Create anew host name hostname name CONFIGURATION 22 Installing the Software Access the System Remotely You can configure the system to access it remotely by Telnet The systems have a dedicated management port and a management routing table that is separate from the IP routing table Configuring the system for Telnet is a three step process Step Task 1 Configure an IP address for the management port 2 Configure a management route with a default gateway 3 Configure a username and password Configure the Management Port IP Address Assign IP addresses to the management ports NOTE Assign different IP addres
3. power supply LEDs shows green If these LEDs are not lit green e Check that the unit is properly installed e Verify the power source If the power supply cannot be verified power off all modules and replace the unit 5 The fan tray LED shows green online You can hear the air flowing through the chassis If the fans are not operating properly or air is not flowing through the chassis e Power off all power supplies e Verify that the fan tray is properly installed e If the fan tray LED remains unlit power down the unit and replace the fan tray After you supply power to the system the following occurs e The fan tray is operating e The green online fan tray RPM and line card LEDs are lit and remain lit as long as the system is receiving power and is operational When you supply power to the chassis the system performs a series of power on self tests RPM and line card LEDs blink as the diagnostic programs run You do not have to do anything while the tests run Observe the process on your console monitor When the boot process completes the card LEDs remain online green and the console monitor displays the command line interface CLI prompt Installing the Hardware 15 Specifications Chassis Physical Design Parameter C7004 C150 Specifications C7008 C300 Specifications Height 15 7 inches 39 88 cm 22 7 inches 57 66 cm Width 17 5 inches 44 45 cm 17 4 inches 37 58 cm Depth 15 3 inc
4. stores the password in the running startup configuration using a DES encryption method e enable secret is stored in the running startup configuration by using a stronger MD5 encryption method Dell Networking recommends using the enable secret password Task Command Syntax Command Mode Create a password to enable password secret level Jevel CONFIGURATION access EXEC encryption type password Privilege mode 24 Installing the Software Create a VLAN The default virtual local area network VLAN is part of the system startup configuration and is by default VLAN 1 You may make another VLAN the default VLAN You cannot delete disable or configure the default VLAN you cannot assign it an IP address and only untagged interfaces can belong to it When you configure an interface a switchport automatically places it in the default VLAN as an untagged interface All switchports must belong to at least one VLAN so to remove a switchport from the default VLAN place it as tagged or untagged in some other VLAN or remove the switchport configuration Task Command Syntax Command Mode Create a VLAN interface vlan vlan id CONFIGURATION Display all VLANs show vlan vlan id EXEC Privilege Assign Interfaces to a VLAN A port may either be an untagged member of a single VLAN or a tagged member of perhaps multiple VLANs e Untagged Ports ports that do not append an 802 1Q VLAN tag to frames on egr
5. 0 100 120 50 60Hz 5 primary 1 redundant 200 240 50 60Hz 5 primary 1 redundant C7008 C300 100 120 50 60Hz 7 primary 1 redundant 200 240 50 60Hz 7 primary 1 redundant Step Task 1 Verify the power switch is in the OFF left position 2 Secure the retaining latch in the unlatched position by tightening the screw into the threaded hole 3 Slide the power supply into the top left most power supply slot Dell Networking recommends installing power supplies starting from the left side top row of the chassis leaving no blank slots between units 4 Lower the retaining latch and tighten it into place 5 Plug the AC power cord into the power receptacle in the face of the power supply 6 Plug the power cord into an AC power outlet NOTE The higher power of power over Ethernet plus PoE 30W port is available only with Power Supply 1600W AC and the PoE line card When using the PoE line card or PoE line card and the Power Supply 1200W AC only 15 4W port power is available The maximum power per port is listed in the following table Power Supply Power Supply Power Supply 1200W AC 1600W AC at 1600W AC at lowline 100 120V highline 200 240V PoE line card 15 4W port 15 4W port 15 4W port PoE line card 15 4W port 30W port 30W port 10 Installing the Hardware Installing RPMs and Line Cards The C7004 C150 system accommodates four line cards and two route processor modules RPMs The C7008 C300 S
6. 00 120 Configuration Configuration AC Power Supply Dependent Dependent TOW ES 200 240 Configuration Configuration Dependent Dependent C7008 C300 Power Supply 1200W 100 120 Configuration Configuration AC Power Supply Dependent Dependent 1600W AC Power Supply 1200W AC 200 240 Configuration Configuration Dependent Dependent Power Supply 1600W AC 200 240 Configuration Configuration Dependent Dependent 8 amp 8 Installing the Hardware For Dell Networking OS version 8 4 6 0 the minimum PSUs required for system power is based on the power requirements of the RPMs the line cards and the type of fan tray present in the chassis System Power Required Power required for 2 RSMs Power Required for Fan Tray Power required for Line cards in the system Number of PSUs Required for System Power System Power Required 90 of PSU power For power requirements corresponding to different components refer to Installing and Maintain ing the C7004 C150 System and Installing and Maintaining the C7008 C300 System If N PSUs are required for system power then N 1 th PSU is reserved for redundant system power For details corresponding to PoE power availability refer to Power Over Ethernet section of Dell Networking OS Configuration Guide gt bP gt B To protect against high voltage shock install a power supply blank on all unused power supply slots Connect the AC power supply to the appropriate branch circuit protection as defi
7. Dell Networking C Series Systems Quick Start Guide ulatory Model C7004 C7008 bout Dell Networking C Series Systems Quick Start Guide latory Model C7004 C7008 bout Notes Cautions and Warnings NOTE A NOTE indicates important information that helps you make better use of your computer 7 CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed A WARNING A WARNING indicates a potential for property damage personal injury or death If you purchased a Dell Series computer any references in this publication to Microsoft Windows operating systems are not applicable Information in this publication is subject to change without notice 2014 Dell Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Copyright 2014 Dell Inc All rights reserved This product is protected by U S and international copyright and intellectual property laws Dell and the Dell logo are trademarks of Dell Inc in the United States and or other jurisdictions All other marks and names mentioned herein may be trademarks of their respective companies Regulatory Model C7004 C7008 2014 01 P NOJVTD9 Rev A02 About this Guide This document is intended as a Quick Start Guide to get new systems up and running and ready for configuration For complete installation and configuration inf
8. able 2 2 Pin Assignments Between the Console and a DTE Terminal Server Console Port RJ 45 to RJ 45 Rollover Cable RJ 45 to DB 9 Terminal Adapter Server Device Signal RJ 45 Pinout RJ 45 Pinout DB 9 Pin Signal RTS 1 8 8 CTS DTR 2 7 6 DSR TxD 3 6 2 RxD GND 4 5 5 GND 20 Installing the Software Table 2 2 Pin Assignments Between the Console and a DTE Terminal Server Console Port RJ 45 to RJ 45 Rollover Cable RJ 45 to DB 9 Terminal Adapter Server Device Signal RJ 45 Pinout RJ 45 Pinout DB 9 Pin Signal GND 5 4 5 GND RxD 6 3 3 TxD DSR 7 2 DTR CTS 8 1 7 RTS Accessing the Console with a DB 25 Adapter You can connect to the console port using an RJ 45 to RJ 45 rollover cable and an RJ 45 to a DB 25 female DTE adapter Table 2 3 Pin Assignments Between the Console and a DTE Terminal Server Console Port RJ 45 to RJ 45 Rollover Cable RJ 45 to DB 25 Terminal Modem Adapter Server Device Signal RJ 45 Pinout RJ 45 Pinout DB 25 Pinout Signal RTS 1 8 5 CTS DTR 2 7 6 DSR TxD 3 6 3 RxD GND 4 5 7 GND GND 5 4 7 GND RxD 6 3 2 TxD DSR 7 2 20 DTR CTS 8 1 N A RTS Installing the Software 21 Default Configuration A version of the Dell Networking OS is pre loaded onto the chassis however the system is not configured when you power up for the first time except for the default host name which is De11 You must configure the system using the CLI Configure Layer 2 Data Link Mode To
9. aximum Thermal Output at 200 240 V 1 647 W 100 120 V 1 555 W 200 240 V 5 618 BTU hour 5 304 BTU hour 2 707 W 100 120 V 2 726 W 200 240 V 9 235 BTU hour 9 299 BTU hour Power Supply 1200W AC Parameter C7004 C150 Specifications C7008 C300 Specifications Nominal input voltage 100 240 V 50 60 Hz Maximum AC Power Supply Input Current Based on 1200 W output for both 100 120 V and 200 240 V lines Maximum System Power Input Maximum power consumption Maximum Thermal Output at 100 120 V Maximum Thermal Output at 200 240 V 14 A 100 V per AC Power Supply 11 A 120 V per AC Power Supply 7 A 200 V per AC Power Supply 6 A 240 V per AC Power Supply 4 261 KVA 100 120 V 4 165 KVA 200 240 V 1 304 W 100 120 V 1 208 W 200 240 V 4 449 BTU hour 4 122 BTU hour 100 240 VAC 50 60 Hz 14 A 100 V per AC Power Supply 11 A 120 VAC per AC Power Supply 7 A 200 VAC per AC Power Supply 6 A 240 VAC per AC Power Supply 8 274 KVA 100 120 V 8 088 KVA 200 240 V 2 361 W 100 120 V 2 175 W 200 240 V 8 055 BTU hour 7 420 BTU hour Installing the Hardware 17 Installing the Software Navigating CLI Modes The Dell prompt changes to indicate the CLI mode You must move linearly through the command modes with the exception of the end command which takes you directly to EXEC Privilege mode the exit command moves you up one command mode level
10. e Chassis in a Two Post Rack A WARNING Use an equipment lift or pallet jack when lifting or moving the chassis Install the chassis into the rack before inserting chassis components Lift the chassis only from the bottom Lifting by the chassis shelves or power supply openings might damage the chassis A WARNING To prevent bodily injury when mounting or servicing this unit in a rack take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety e Mount this unit at the bottom of the rack if it is the only unit in the rack e When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack e Tf the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Installing the Hardware 5 Follow these steps to install the chassis into a 19 inch equipment rack Step Task 1 Determine the chassis mounting location in the equipment rack 2 Orient the bar with the arrows pointing upward The smooth side of the bar should face outward 3 Attach the bar to the equipment rack brackets using the mounting screws provided by the rack manufacturer 4 Use an equipment lift to align the chassis rack mount holes with the equipment rack holes and situate the chassis on top of the equipment rack bar 6 Install
11. ess and do not accept tagged frames on ingress tagged frames are dropped You must connect untagged ports to VLAN unaware devices e Tagged Ports ports that append an 802 1Q tag to frames on egress and accept only tagged frames on ingress untagged frames are dropped You must connect tagged ports to VLAN aware devices When you configure an enabled port as a switchport the port is placed in the default VLAN To remove a switchport from the default VLAN remove the switchport configuration To move the port to another VLAN add it to the desired VLAN as either a tagged or untagged member To view just the interfaces that are in Layer 2 mode enter the show interfaces switchport command in EXEC mode Installing the Software 25 Step Task Command Syntax Command Mode 1 Assignaswitchporttoa tagged untagged interface INTERFACE VLAN VLAN 2 Display all switchports show vlan EXEC Privilege and the VLANs of which they are members Assign an IP address to a VLAN NOTE You cannot assign an IP address to the default VLAN which by default is VLAN 1 To assign another VLAN ID to the default VLAN use the default vlan id vlan id command Task Command Syntax Command Mode Configure an IP address and mask on ip address ip address INTERFACE the interface mask secondary Connecting the Chassis to the Network After you have completed the hardware installation and software configuration you can co
12. hes 38 86 cm 14 4 inches 44 20 cm Chassis weight 38 Ibs 17 24 kg with factory installed components 86 63 Ibs 39 29 kg fully loaded 55 Ibs 24 95 kg with factory installed components 152 27 Ibs 69 07 kg fully loaded Environmental Parameters Parameter C7004 C150 Specifications C7008 C300 Specifications Temperature Relative humidity 40 to 158 F 40 C to 70 C storage temperature 5 to 95 non condensing 40 to 158 F 40 C to 70 C storage temperature 5 to 95 non condensing AC Power Requirements Power Supply 1600W AC Parameter C7004 C150 Specifications C7008 C300 Specifications Nominal input voltage 100 240 V 50 60 Hz Maximum AC Power Supply Input Current Based on 1200 W output for 100 120 V and 1600 W output 200 240 V lines Maximum System Power Input 16 14 A 100 V per AC Power Supply 11 A 120 V per AC Power Supply 9 A 200 V per AC Power Supply 7 A 240 V per AC Power Supply 6 897 KVA 100 120 V 7 315 KVA 200 240 V Installing the Hardware 100 240 VAC 50 60 Hz 14 A 100 V per AC Power Supply 11 A 120 VAC per AC Power Supply 9 A 200 VAC per AC Power Supply 7 A 240 VAC per AC Power Supply 9 667 KVA 100 120 V 12 596 KVA 200 240 V Parameter C7004 C150 Specifications C7008 C300 Specifications Maximum power consumption Maximum Thermal Output at 100 120 V M
13. ing the Hardware Step Task 5 Insert screws provided with your rack through the chassis rack mounting bracket and into the equipment rack and tighten them Rack Mounting the C7004 C150 Chassis Rack Mounting the C7008 C300 Chassis eo0000000 Installing the Hardware Installing Power Modules VAN CAUTION Do not install the Power Supply 1200W AC and Power Supply 1600W AC in the same chassis The line cards will power down and data may be lost If there is a failure in the power supply you must replace it Power supplies are not field serviceable The C7004 C150 has six power supply slots at the front bottom of the chassis The C7008 C300 has eight power supply slots at the front bottom of the chassis The slots accept either the 1200W or 1600W AC power supply units PSUs AC Power Supplies e There are two types of power supplies Power Supply 1200W AC and Power Supply 1600W AC The minimum and redundant power supplies required to operate are listed in the table below Dell Networking recommends the redundancy configuration e The following table lists the PSU requirements for Dell Networking OS version 8 4 5 0 or prior 1600W AC PSU is recognized by version 8 4 5 0 or later Voltage Minimum Minimum with PSUs Redundant PSUs C7004 C150 Power Supply 1200W 1
14. ing the ejector levers simultaneously until they are in the open position Hold the card assembly by the metal carrier edges Avoid touching the printed circuit board and connector pins Align the card with the guide and gently slide it into any line card slot until the card is about halfway into the slot Z NOTE To determine which slots are for the RPMs and which are for the line cards use the markings on the fan tray Continue sliding the card until you feel the connectors engage with the chassis backplane Installing the Hardware Step Task 5 Rotate the levers toward the card to seat the backplane connectors and line card in place Push on the knurled section of the levers until the thumb tabs pop up and lock the unit in place AN CAUTION Installing a card without fully engaging the locking mechanism might damage the EMI seal on the card below it when you install that card 6 Install a blank panel in all slots that do not have a card and secure it with the screws provided Installing the Fan Tray The C Series chassis contains one field replaceable fan tray There are two types of fan trays that you can install one contains six fans that run at varying speeds depending on system temperature the other contains six fans that run at a constant speed For both types of trays air flows through the system toward the fans right to left and is exhausted on fan side of the chassis The fan tray is accessible f
15. ned by local electrical codes Verify that the remote power source complies with the system input power specifications WARNING Use only the AC power cord supplied with the AC power supply Do not supply power to your system until you install the power supplies fan tray route processor modules RPMs and line cards WARNING This product relies on the building s installation for short circuit overcurrent protection Ensure you use a fuse or circuit breaker no larger than 120 VAC 15A U S 240 VAC 10A international on the phase conductors all current carrying conductors WARNING The C7008 C300 does not have a main disconnect device installed It is the responsibility of the installer to provide a suitable disconnecting device in the building installation and ensure that it is located installed near the equipment and is easily accessible WARNING Do not install the Power Supply 1200W AC and Power Supply 1600W AC in the same chassis The line cards will power down and data may be lost Installing the Hardware 9 ZN WARNING The 7008 C300 and C7004 C150 operates in either of two voltage ranges The different power supply configuration supported is listed in the following table As a safety precaution do not install more than the recommended maximum number of PSUs shown below as this causes high leakage current Install blank panels in all unused PSU slots Voltage Frequency Maximum PSUs C7004 C15
16. nnect to your company network by following your company s cabling requirements 26 Installing the Software Printed in the U S A www dell com support dell com OOJVTD9A02
17. ormation refer to the following documents Documentation C7004 C150 C7008 C300 Hardware installation and Installing and Maintaining Installing and Maintaining power up instructions the C7004 C150 System the C7008 C 300 System Software configuration Dell Networking OS Dell Networking OS Configuration Guide Configuration Guide Command line interface Dell Networking OS Dell Networking OS Command Line Reference Command Line Reference Guide Guide Latest updates Dell Networking OS Dell Networking OS Release Notes for C Series Release Notes for C Series About this Guide 3 Installing the Hardware This guide assumes all site preparation has been performed before installing the chassis Installing the Chassis To install the C7004 C150 and the C7008 C300 chassis Dell Networking recommends completing the installation procedures in the order presented below NOTE Unless stated otherwise the installation instructions apply to both the C7004 C150 and C7008 C300 chassis Always handle the system and its components with care Avoid dropping the switch or its field replaceable units FRUs AN CAUTION Always wear an electrostatic discharge ESD preventive wrist or heel ground strap when handling the chassis and its components As with all electrical devices of this type take all necessary safety precautions to prevent injury when installing this system ESD damage can occur if components are mishandled Installing th
18. rom the front of the chassis A WARNING To ensure proper temperature and airflow control the fan tray must always be installed and operating properly K NOTE The system does not have an air filter Ensure that you clean the installation site and chassis regularly Step Task 1 Slide the fan tray into the fan slot 2 Gently push on the front of the tray until it stops The fan tray should be flush with the chassis 3 Use a 2 Phillips screwdriver to secure the fan tray into place by tightening the screws at the top and bottom of the fan tray Installing the Hardware 13 C7004 C150 C7008 C300 K NOTE The fan tray light emitting diodes LEDs remains lit when the chassis is powered up and the fan tray is functioning properly Power Up Sequence Before you supply power to the chassis Dell Networking recommends re inspect your equipment rack and chassis VAN CAUTION Never operate the system without a fan tray 14 Installing the Hardware Step Task 1 Verify that the power source complies with the system input power requirements 2 Energize the remote power source or outlet 3 On the C7004 C150 toggle the switch on the AC power supplies to the ON right position On the C7008 C300 toggle the switch on the AC power supplies to the ON top position 4 The
19. ses to each RPM s management port Step Task Command Syntax Command Mode 1 Enter INTERFACE interface ManagementEthernet CONFIGURATION mode for the slot port Management port 2 Assign an IPv4 or ip address ipv4 address ipv6 INTERFACE IPv6 address to the address mask interface 3 Enable the interface no shutdown INTERFACE Configure a Management Route Define a path from the system to the network from which you are accessing the system remotely Management routes are separate from IP routes and are only used to manage the system through the management port Installing the Software 23 Task Command Syntax Command Mode Configure an IPv4 or IPv6 management route ipv4 address CONFIGURATION management route to the ipv6 address mask gateway network from which you are accessing the system Configure a Username and Password Configure a system username and password Task Command Syntax Command Mode Configure a username username username password CONFIGURATION and password to encryption type password access the system remotely Configure the Enable Password EXEC Privilege mode is accessed by the enable command Configure a password as a basic security measure When using a console connection EXEC Privilege mode is unrestricted by default it cannot be reached by a VTY connection if you have not configured a password There are two types of enable passwords e enable password
20. tray e The VX2NW C Series 48 PORT 1GIGABIT ETHERNET LINE CARD SFP OPTICS REQUIRED SERIES CB and F9M51 C Series 8 PORT 10GIGABIT ETHERNET LINE CARD XFP OPTICS REQUIRED Installing the Hardware 11 SERIES CB line cards are interchangeable between the C7008 C300 and C7004 C150 only if the chassis is running Dell Networking OS version 7 6 1 0 or later To control airflow for adequate system cooling personal safety and EMI containment during operation blanks are required in empty slots Yoou must install all chassis slots with operational modules or blanks Always replace cards and blank panels immediately Installing RPMs and Line Cards A A K WARNING Always wear an ESD preventive wrist or foot heel ground strap when handling RPMs or line cards Place RPMs and line cards on an antistatic surface when they are not installed ESD damage can occur when components are mishandled CAUTION Unlock the levers before inserting the line card into the chassis Fully engage the locking mechanism after the card has been inserted not doing so might damage the card below it when you insert that lower card NOTE The fan tray face panel has slot number markings for the RPMs and line cards To simplify RPM and line card installation insert the fan tray before the line cards Step Task 12 Extend the left and right card levers by first pressing gently down on the thumb tabs in the ejector levers and then pull
21. ystem accommodates eight line cards and two route processor modules RPMs RPMs The C Series system requires at least one RPM however Dell Networking recommends two RPMs e One RPM provides 48 Gigabits of bandwidth to each line card e Two RPMs provides 96 Gigabits of bandwidth to each line card e To control airflow for adequate system cooling personal safety and EMI containment during operation blanks are required in empty slots You must install all chassis slots with operational modules or blanks Always replace cards and blank panels immediately e The blank panels for RPMs and line cards are different sizes RPM blanks are smaller be sure that blank panels are installed in the correct slots e RPMs are hot swappable high availability HA is supported e If your system contains two RPMs both RPMs must have the same software image e RPMs are interchangable between the C7008 C300 and the C7004 C150 only if they are running Dell Networking OS version 7 6 1 0 or later VAN CAUTION RPMs are designed to be installed in either the RO or R1 slot Do not force RPMs into line cards slots RPMs are keyed differently than line cards to prevent improper installation Line Cards Line cards are hot swappable You can insert line card into any line card slot On the C7004 C150 line card slots are numbered 0 to 3 On the C7008 C300 line card slots are labeled 0 to 7 You can see the slot numbering labels when you install the fan

Download Pdf Manuals