Sencor SBP 690 blood pressure unit

image

Contents

1. The cuff with an adjustable length of 22 42 cm is intended only for adults Do not twist or excessively bend the cuff or the air hose Take care not to damage the cuff or the air hose by sharp items such as pins needles etc Do not disassemble the device and do not make any alterations to it Use only original accessories supplied with the device Do not use the device if your arm is injured If you suffer from a circulatory system disorder such as atherosclerosis diabetes liver or kidney illness heavy hypertension external circulation disorders etc consult your doctor or an expert healthcare professional about the suitability of using a blood pressure monitor or similar devices If you are undergoing medical treatment or taking medication consult the use of this device with a doctor Rest at least 5 to 10 minutes before measuring blood pressure Wait at least 4 to 5 minutes before measuring again so that your blood circulation can return to the normal state Do not perform measurement sooner than 30 45 minutes after consuming beverages containing caffeine or after smoking cigarettes Remove all tight clothing from your arm before taking a blood pressure measurement Use the cuff only on the arm Do not use on another part of the body Do not start measurement until the cuff is attached to the arm Perform the measurement in a calm and relaxed position Do not move the device during measurement The device automatically releases
2. time and measuring unit The measured values will be stored in memory together with the date and time of measurement Check that the device is turned off the LCD display is off or turn it off using the START STOP button Hold down the SET button for seconds Year will start to flash on the display Use the MEM button to set the current year Confirm the setting by pressing the SET Y button The device will automatically switch to the month setting mode Use the MEM A button to set the current month Confirm the setting by pressing the SET V button The device will automatically switch to the day setting mode Set the current day of the month using the MEM A button Confirm the setting by pressing the SET button The device will automatically switch to the hour setting mode Use the MEM button to set the current hour Confirm the setting by pressing the SET Y button The device will automatically switch to the minute setting mode Use the MEM button to set the current minutes Confirm the setting by pressing the SET button The device will automatically switch to the measuring unit selection mode Select the measuring unit mmHg or kPa using the button Confirm the setting by pressing the SET button Note The standard measuring unit for the measurement of blood pressure is mmHg millimetres of a mercury column After completing the setup done will appear on the display Setup of the date time and measur
3. air when the pressure in the cuff exceeds 300 mmHg If the automatic air release does not occur remove the cuff and press the START STOP button to end the pressurisation of the cuff Remember that blood pressure fluctuates over the course of the day and is also affected by many factors such as smoking consumption of alcohol taking medicines and physical activity The measurement results should be evaluated by a doctor or another expert who knows your long term health condition Please do not make conclusions on the basis of the results yourself By regularly measuring your blood pressure and recording the measurement results you will provide your doctor with a complete picture of your blood pressure during natural activity Blood pressure values measured using the oscillometric method when using this device are equivalent to the measurement results taken by an experienced observer using the auscultatory listening method using a blood pressure monitor with a stethoscope This device is not designed for a continuous monitoring of blood pressure during medical treatment such as for example operations etc This device is designed for domestic use and does not substitute for professional medical care EN 4 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with Upper Cuff SBP 690 Keep the device and the batteries out of reach of children We recommend saving the original package pac
4. cuff from your arm after completing the measurement Copyright 2012 Fast R a s Revision 12 2012 Digital Blood Pressure Monitor with Upper Cuff SBP 690 4 Recalling memory 41 To show the last measurement record press the MEM button 4 2 To scroll through the individual measurements in memory use the MEM and SET buttons 43 For each measurement the month day and the time the measurement was taken will be shown in the bottom left hand part of the display 4 4 The most recent measurement stored in memory always has the sequence number of 1 The maximum memory capacity is 60 measurements As soon as the maximum memory capacity is achieved every new measurement will delete the oldest measurement 5 Deleting memory 5 1 Check that the device is turned off the LCD display is off or turn it off using the START STOP button Hold down the MEM button with your finger for 3 seconds The message del all delete all will appear on the display 5 2 Press the SET button to confirm the deletion of all measurements in memory The display will show the message del delete and done completed The device will automatically turn itself off Note If you wish to interrupt the deletion process press the START STOP button 5 3 No values will appear on the display when the memory is subsequently retrieved Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with an Upp
5. 5 minutes and then repeat the measurement measurement E20 or E21 Measurement error Rest for 4 to 5 minutes and then repeat the measurement If a different error message in the format E number code or Ee number code appears on the screen that is not included in the table turn off the device take the batteries out of it or disconnect the power adapter from the electrical power socket Wait a while and then reinsert the batteries or reconnect the power adapter to the electrical power socket After a few minutes repeat the measurement If the problem persists contact your vendor or an authorised service centre MAINTENANCE AND CLEANING Keep the device clean Wipe off dust using a lightly damp cloth Do wash the device the pressurising cuff under running water or submerge it in water Do not use abrasive cleaning products or petrol for cleaning Otherwise the device may be damaged EN 10 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 STORAGE If you will not be using the device for an extended period of time remove the batteries Protect the device against impacts and falls Store the device in a clean dry place out of reach of children Do not expose the device to direct sunlight or extreme temperature changes CALIBRATION Recommendation To ensure accurate measurement results we recommend the device i
6. Digital Blood Pressure Monitor with an Upper Arm Cuff User s manual SENCOR SBP 690 Thank you for choosing the SBP 690 digital blood pressure monitor and we hope that you will be happy with it The SBP 690 blood pressure monitor presents the perfect combination of attractive design simple controls and functionality EN 1 Copyright 2012 Fast R a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 CONTENTS WHAT YOU SHOULD KNOW ABOUT BLOOD PRESSURE 3 IMPORTANT INSTRUCTIONS rtur od bees Conse eee Sa Pee eee eee ee hae eas 4 BASIC FUNCTIONS AND FEATURES OF THE BLOOD PRESSURE MONITOR 5 DESCRIPTION OF THE BLOOD PRESSURE MONITOR 0 00 e eee eee ee 5 DESCRIPTION OF THE DISPLAY 6 USING THE BLOOD PRESSURE MONITOR 6 TROUBLESHOOTING de dene eed dee eed deme eee 10 MAINTENANCE AND CLEANING 23 c c5 003000008 eee heey vie heya has 10 STORAGE deed og dea deena en de 11 CALIBRATION Aiea alae ane ake Athenee a agen 11 ELECTROMAGNETIC INTERFERENCE eee eee eee ee eo ee 11 COMPLIANCE WITH STANDARDS 0 0000 eee ee 11 TECHNICAL SPECIFIGATIO
7. NS lt Sarena Dba haw veal 12 INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS 13 DISPOSAL OF USED BATTERIES ee ee weed eed ee 13 DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT 13 2 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 WHAT YOU SHOULD KNOW ABOUT BLOOD PRESSURE What is blood pressure Blood pressure is defined as the pressure exerted by the blood on the walls of the arteries through which it flows Blood pressure fluctuates during the course of each heartbeat between the maximum systolic and the minimum diastolic value Blood pressure is influenced by many factors such as physical activity fear anger or by a certain time of day Blood pressure changes constantly over the course day Early in the morning it rises and before noon it falls In the afternoon it rises again and then falls in the evening hours Blood pressure may also change within an instant and so the subsequent measurement results may vary Why is it important to measure your blood pressure at home Many people have increased blood pressure when they visit their doctor while at home their blood pressure is in the normal range This is the so called white coat syndrome and may affect up to 15 of the population Home blood pressure measurement eliminates the white coat syndr
8. and batteries Accessories Blood pressure cuff 4 x LR6 AA type battery user s manual We reserve the right to change text and technical specifications 12 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with Upper Cuff SBP 690 INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS Dispose of packaging material at a public waste disposal site DISPOSAL OF USED BATTERIES Batteries contain environmentally damaging compounds and therefore do not belong in standard household waste Take the batteries to an appropriate collection point which will provide for their ecological disposal You can obtain the contact for the nearest collection point from you town council or from your retailer DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT The meaning of the symbol on the product its accessory or packaging indicates that this product shall not be treated as household waste Please dispose of this product at your applicable collection point for the recycling of electrical amp electronic equipment waste Alternatively in some states of the European Union or other European states you may return your products to your local retailer when buying an equivalent new product The correct disposal of this product will help save valuable natural resources and help in preventing the potential negative impact on the environment and human health whi
9. ch could be caused as a result of improper liquidation of waste Please ask your local authorities or the nearest waste collection centre for further details The improper disposal of this type of waste may fall subject to national regulations for fines For business entities in the European Union If you wish to dispose of an electrical or electronic device request the necessary information from your seller or supplier Disposal in other countries outside the European Union If you wish to dispose of this product request the necessary information about the correct disposal method from local government departments or from your seller EN 13 Copyright 2012 Fast R a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 EN 14 Copyright 2012 Fast CR a s Revision 12 2012
10. er Arm Cuff SBP 690 TROUBLESHOOTING In this chapter you will find solutions to problems that you may encounter when using this device If you were unable to remedy the problem according to the following instructions contact an authorised service centre Problem error Possible cause Possible solution message After pressing the Batteries are flat Replace the batteries START STOP button The batteries are Insert the batteries with the correct polarity a display does not inserted incorrectly direction as shown in the battery compartment urn on The adapter is not Connect the adapter to a power socket connected to a power socket The symbol Dis shown Batteries are almost Replace the old batteries with new ones on the display flat E1 The cuff is not attached Turn off the device using the START STOP to the arm or is button Attach the cuff to you arm according attached to the arm too to the instructions in chapter Attaching and loosely securing the cuff and repeat the measurement E2 The cuff is too tight Turn off the device using the START STOP button Attach the cuff to you arm according to the instructions in chapter Attaching and securing the cuff and repeat the measurement E3 The pressure in the cuff Rest for 4 to 5 minutes and then repeat the was exceeded measurement E10 or E11 The device detected Movement may affect the measurement result movement during the Rest for 4 to
11. ing units is complete Then the device turns itself off automatically Note Setting range year 2000 2050 time format 24 hour Measurement Basic instructions for achieving the most accurate measuring results Always take measurements at the same time of day ideally in the morning at noon and in the evening under the same conditions or according to the recommendations of your doctor Do not perform measurement sooner than 30 45 minutes after consuming coffee tea or smoking a cigarette Wait at least 20 minutes after taking a hot shower or bath During measurement sit calmly relaxed and don t talk Do not move the arm to which the cuff is attached Wait approximately 4 5 minutes before measuring again Attaching and securing the cuff Remove all tight clothing from the arm before attaching the cuff Attach the cuff 2 3 cm above the elbow cavity and ensure that the air hose is located above the brachial artery as illustrated on the cuff label EN 7 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 The cuff must be too loose or too tight Verify the correct tightness by easily inserting finger between the cuff and the arm Place the forearm on an even table surface Note Blood pressure can be measured both on the left and the right arm However the measurement results from the left and right arm may differ and for this reason i
12. kaging material receipt and warranty for the duration of warranty In the case of transportation pack the product using the original packaging materials only BASIC FUNCTIONS AND FEATURES OF THE BLOOD PRESSURE MONITOR Measurement of the systolic and diastolic blood pressure and pulse Detection of cardiac arrhythmia Adjustable length cuff for arm circumferences from 22 to 42 cm Automatic inflation and air release of the cuff Large LCD display 60 memory positions for storing measurement results including date and time Battery or power adapter not included operation DESCRIPTION OF THE BLOOD PRESSURE MONITOR SET button START STOP button Power adapter connection socket Battery compartment Battery compartment cover Blood pressure cuff Air hose Air hose connection socket LCD display MEM A button 6 6 5 Copyright 2012 Fast a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 DESCRIPTION OF THE DISPLAY OOOO Optimal TIME DATE Display of the memory sequence number Display of date and time Measured blood pressure category Systolic pressure value Flat battery indicator Measuring unit Detection of cardiac arrhythmia Diastolic pressure value Cuff air release indicator Pulse rate number of pulses minute USING THE BLOOD PRESSURE MONITOR 1 Selecting a power source Using an in
13. ome and provides the doctor with a picture of the various blood pressure levels during your natural activity Blood pressure classification by the World Health Organisation The following table shows the blood pressure classification for an adult person according to the World Health Organisation WHO Blood pressure category Systolic blood pressure Diastolic blood pressure in mmHg in mmHg Optimal lt 120 lt 80 Normal 120 129 80 84 High normal 130 139 85 89 Hypertension Grade 1 mild 140 159 90 99 Hypertension 2nd level medium 160 179 100 109 Hypertension Grade 3 heavy 2180 2110 Isolated systolic hypertension gt 140 lt 90 What is cardiac arrhythmia Cardiac arrhythmias are a disorder of the rhythm of the heartbeat They result from a varied creation or conduction of electrical impulses in the heart Many cardiac arrhythmias are only temporary in nature Such types of arrhythmias are considered to be harmless and include the cases where the heart misses or adds a beat This may be caused by strong emotions or exercise However there exist types of arrhythmia which may be life threatening and require professional treatment Symptoms of cardiac arrhythmia Symptoms of cardiac arrhythmia strong or accelerated beating of the heart feeling of tiredness vertigo loss of consciousness lack of breath and chest pain Symptoms of bradycardia slowed down heart activity feeling of tiredness lack of breath vertigo or di
14. ring method Oscillometric Display LCD display size 93 x 61 mm Memory capacity 60 records Measuring range Pressure 0 300 mmHg 0 40 kPa Pulse 40 199 pulses minute Measurement accuracy Pressure 3 mmHg 0 4 kPa at an ambient temperature of 15 25 C 6 mmHg 0 8 kPa at an ambient temperature of 10 14 C and 26 40 C Pulse 5 9 Adjustable size of the cuff 22 42 cm Power source 4 x type LR6 AA battery 6 V or a power adapter Sencor SBX 001 not included input 100 240 V 50 60 Hz 400 mA output 6V 1A Protection against injury by electric shock Medical electrical device with an internal power supply only when batteries are used Sencor SBX 001 power adapter not included Class Il protection Applied part type B Degree of protection against the intrusion of water Safety of use in the presence of anaesthetic combustible mixtures The device is not suitable for use in the presence of combustible anaesthetic and air mixtures or combustible anaesthetic and oxygen mixtures or mixtures containing oxides of nitrogen Operating mode Continuous operation with short term loading Operating conditions Ambient temperature 5 C to 40 C humidity lt 80 Storage conditions Ambient temperature 20 C to 60 C humidity 10 93 Dimensions of the device 140 x 120 x 70 mm Weight of the device 287 g without cuff
15. s calibrated after two years of operation All costs associated with the calibration are borne by the customer ELECTROMAGNETIC INTERFERENCE To prevent measurement inaccuracies caused by electromagnetic interference do not use this device in the vicinity of mobile telephones or microwave ovens COMPLIANCE WITH STANDARDS This device complies with European standards EN 60601 1 Medical electrical devices Part 1 General basic safety and necessary functionality requirements EN 60601 1 2 Medical electrical devices Part 1 2 General basic safety and necessary functionality requirements Group norm Electromagnetic compatibility Requirements and tests EN 1060 1 Non invasive blood pressure monitors Part 1 General requirements EN 1060 3 Non invasive blood pressure monitors Part 3 Specific requirements for electromechanical systems for the measurement of blood pressure Enz This device meets the requirements of the European directive 93 42 EEC w The manufacturing date is marked on the rating label of the device andl Manufacturer Zhongshan Transtek Electronics Co Ltd Jinan Road Jinbiao Minzhong Zhongshan Guandong China Authorised representative for the EU MDSS Medical Device Safety Service GmbH ec rer Schiffgraben 41 30175 Hannover Germany EN 11 Copyright 2012 Fast R a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 TECHNICAL SPECIFICATIONS Measu
16. t is necessary to perform repeated measurements always on the same arm 3 3 Measuring blood pressure 3 3 1 Turn on the device by pressing the START STOP button In a short time all the elements will light up on the LCD display 3 3 2 If residual air remains the cuff the symbol will appear on the display for a short time and the air will be released The value 0 mmHg or kPa and the time of measurement will appear on the display 3 3 3 The device will automatically pressurise the cuff While the cuff is being pressurised the pulse rate is being detected This is indicated by the flashing symbol on the LCD display 3 3 4 Then the pressure in the cuff is continuously released and the values of the systolic SYS and diastolic DIA pressure pulse rate and the blood pressure are automatically determined The blood pressure categories are defined in the following table Blood pressure category Measured blood pressure value in G1 G2 G3 mmHg Optimal Normal Normal high Mild Medium Heavy hypertension hypertension hypertension SYS systolic value 121 130 131 140 141 160 161 180 DIA diastolic value lt 80 81 85 86 90 91 100 101 110 Note If the symbol 2 appears on the display the device has detected cardiac arrhythmia 3 3 5 Turn off the device by pressing the START STOP button If you do not turn off the device it will turn itself off automatically within 1 minute of the last measurement Remove the
17. ternal power source To power the device using an internal power source use four LR6 AA type batteries 4 x 1 5 V Remove the battery compartment cover and insert four LR6 AA type batteries When inserting the batteries ensure the correct polarity as shown in the battery compartment Close the cover The batteries need to be replaced when the display shows the symbol the display is dim the display does not turn on Using an external power source A power adapter Sencor SBX 001 output 6 V 1 A can be purchased To purchase the power adapter please contact your vendor Connect the power adapter connector to the socket on the right side of the device Insert the power supply plug into the an electrical power socket Only use the adapter designed for this device EN 6 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with Upper Cuff 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 SBP 690 Note If the polarity is reversed when the batteries are inserted the device may not only not function but may also heat up Do not combine used and new batteries or batteries of various types e g alkaline batteries and rechargeable batteries Do not use the adapter and batteries at the same time Saved records will remain stored in the memory even after the batteries are replaced Setting the date time and measuring units Before taking measurements set the current date
18. zziness Symptoms of tachycardia accelerated heart activity the heartbeat may be felt in the neck or as a beat in the chest with irregular speed feeling of unease weakness lack of breath dizziness sweating and vertigo EN 3 Copyright 2012 Fast CR a s Revision 12 2012 Digital Blood Pressure Monitor with an Upper Arm Cuff SBP 690 Can cardiac arrhythmia be treated Cardiac arrhythmia can to a certain extent be prevented by eliminating the stimuli physical exertion stress smoking consumption of alcohol coffee or other beverages containing caffeine affecting the nervous system Many types of cardiac arrhythmias do not require treatment as they are naturally compensated by the immune system Other types of cardiac arrhythmias must be treated with medication antiarrhythmic agents defibrillator implants or pacemakers The treatment method depends on the type of cardiac arrhythmia age of the patient and their physical condition IMPORTANT INSTRUCTIONS AN Prior to using this product please read the user s manual thoroughly even in cases when one has already familiarised themselves with previous use of similar types of products Use the product only as described in this manual Keep this manual for later use Caution Not following the instructions contained in this user s manual may lead to faulty operation of the device or its damage This device is designed for non invasive blood pressure measurement