Home

Tripp Lite INTRNTOFFC300 uninterruptible power supply (UPS)

image

Contents

1. not dispose of the batteries ina fire Do not open the UPS or the batteries Do not short or bridge the battery terminals with any object There are no user serviceable parts inside the UPS Battery replacement should be performed only by authorized service personnel using the same number and type of batteries Sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or call 1 800 SAV LEAD 1 800 728 5323 for complete recycling information CAUTION AV Batteries left discharged will suffer a permanent loss of capacity If the UPS is stored or not used for three months or longer fully recharge the batteries by plugging the UPS into a live AC outlet turning the Power Switch OFF and letting the UPS charge for 4 6 hours When the Power Switch is ON the Battery Backup Protected Surge Protected Outlets are energized from the internal battery even when the unit is not plugged in 3 CONTRO 1 Power On Off Switch The On Off switch is recessed to prevent accidental equipment turn off while allowing convenient one touch power control I ON and O OFF Note Even when switched OFF the UPS maintains a battery charge whenever it is plugged in and utility voltage is present Alarm Will Sound If the UPS detects either an undercharged battery or overloaded outlets when you turn the Power Switch ON Follow the instructions under the Check Battery LED and UPS Overload LED head
2. OWNER S MANUAL TRIPP LITE POWER PROTECTION MBOIOI 3107A INTERNET 300 UPS SYSTEM _ 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 ERa aet 300VA UPS o E AA WITH BATTERY BACKUP AND SURGE PROTECTION e Save Your Open Files e Protect All Your Equipment e Maintain Your Internet Connection Copyright 2001 Tripp Lite All rights reserved Internet Office is a registered trademark of Tripp Lite NOM Orme nts Save these instructions and thoroughly read the Operation and Safety sections before using your Internet Office 300 UPS Save the original carton and styrofoam inserts If you require service your warranty may be voided if the Internet Office 300 UPS is sent back to Tripp Lite in improper packaging 1 OPERATION 1 1 Operation Overview The Internet Office 300 UPS protects your equipment from all power problems blackouts brownouts surges spikes and line noise Reliable battery power allows you to complete work save data and safely shut down your system in the event ofa blackout Internet Office protects your equipment on both the AC and modem network line When AC power is present the UPS is keeping the battery constantly charged and connected equipment is powered directly from the AC power line 1 2 Step By Step Operation The UPS is simple to operate and takes just a few minutes toset up Follow the steps below before you turn the UPS ON STEP 1 Plug
3. e side of the UPS Position the UPS at least 6 inches 15 cm away from any monitors or floppy disks Small magnetic fields present during backup operation can cause monitor interference or disrupt information on disks Two slots on the rear of the UPS allow for secure wall or surface mounting To mount use the mounting template on the back of this manual to install fasteners with 5 16 8 mm clearance from the mounting surface Fasteners must be able to support at least 5 lb 2 kg Connect the UPS to a two pole three wire grounded AC power outlet To reduce the risk of fire connect only to a circuit provided with 15 amperes overcurrent protection in accordance with the National Electrical Code ANSI NFPA 70 or your local electrical code Never plug a UPS into itself this will damage the unit and void your warranty Never plug a surge suppressor into any of the outlets this will overload the UPS when operating from battery power Since the UPS already has surge suppression built in adding extra surge suppression is not necessary The UPS may be damaged if connected to a motor powered AC generator with voltage and frequency output beyond nominal accepted ranges Consult the generator manufacturer or Tripp Lite Customer Service before connecting the UPS to a generator 2 2 Battery Safety Warnings A WARNING A Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions Do
4. ings 2 Battery Backup Protected Surge Protected Outlets These outlets provide both battery backup and surge protection Plug your computer monitorand other critical equipment into these outlets NOTE DO NOT PLUG PRINTERS INTO THESE OUTLETS 3 Surge Protected Outlets While all 6 outlets will provide surge and line noise protection the 3 Surge Protected Outlets will not supply battery backup Plug equipment such as a printer scanner or fax machine that does not require battery backup during a utility power failure into these outlets 4 RJ11 45 Telephone Dataline Surge Suppressor Jacks RJ11 45 jacks provide protection against surges on the telephone and data lines Plug either a single telephone line or a 10Base T 100Base TX network cable into UPS s IN jack Plug telephone line 6 ft RJ11 cordset included or the network cable from your equipment into UPS s OUT jack Note Connecting equipment to the RJ11 45 jacks is optional The UPS will still work properly without this connection 5 Circuit Breaker The Circuit Breaker protects equipment plugged into the 3 Surge Protected Outlets against short circuits and system overload If the circuit breaker trips unplug at least one piece of equipment from the Surge Protected Outlets and reset the breaker by pressing the button back into place 6 Using Battery LED This LED will light when the UPS is providing your equipment with battery power during a blackout or brownout or du
5. ou to faulty outlet wiring at your facility either no ground circuit or a reversed polarity in the building wiring This LED will detect most common wiring faults but will not necessarily detect every possible type of fault If it lights consult a qualified electrician to examine your building wiring
6. ring self test when switch is turned ON When this indicator lights close any files you are working on and shut down your computer Then turn the UPS OFF to conserve the battery charge When light is off the UPS is constantly recharging the battery for later use Alarm Will Sound If the utility power fails Alarm will sound once every second You should close your files and turn off your system immediately 7 Check Battery LED This LED lights when the UPS detects a weak battery If this indicator lights follow this procedure STEP 1 Allow UPS to charge for 4 to 6 hours leave it switched ON or OFF and plugged in STEP 2 Test the battery by switching the UPS OFF and back ON again STEP 3 If the Check Battery LED lights again the battery must be replaced Call Tripp Lite Customer Support at 773 869 1234 or visit or website at www tripplite com for more information Alarm Will Sound If the Check Battery indicator is lit The alarm will sound for 10 seconds 8 UPS Overload LED When using battery power this LED lights when the three Battery Backup Protected Surge Protected Outlets are overloaded connected to equipment that exceeds 300VA 150 Watts Alarm Will Remain On until the overload is removed Disconnect equipment that does not require battery backup from the Battery Backup Protected Surge Protected Outlets to eliminate the overload 9 Building Wiring Fault LED This LED instantly alerts y
7. the UPS into an electrical outlet that does not share a circuit with a heavy electrical load e g an air conditioner or refrigerator etc STEP 2 Determine the total VA or wattage draw of all the equipment you plan on connecting to the Battery Backup Protected Surge Protected Outlets Look on the equipment nameplate for this information If the equipment is listed in amps multiply the number ofamps by 120 to determine VA Example 1 ampx 120 120 VA The total VA for all the equipment cannot exceed 300 The total wattage cannot exceed 150 STEP 3 Plug your computer and monitor into the three Battery Backup Protected Surge Protected Outlets Remember they provide both surge and battery backup protection NOTE Do not plug laser printers into these outlets STEP 4 Plug your peripherals e g printer scanner or fax machine into the three Surge Protected Outlets Remember they are not supplied with battery backup duringa utility power failure 2 SAFETY 2 1 Installation Safety Warnings A WARNING A Tripp Lite does not recommend the use of any of its UPS Systems in any life support application where a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of the life support device Contact Tripp Lite for further information A CAUTION A Donotallow the UPS to be exposed to moisture rain dust excessive heat or direct sunlight Do not block the cooling vents on th

Download Pdf Manuals

image

Related Search

Related Contents

Parts book for Singer 211W151 - Superior Sewing Machine and  Untitled - Amici della Biblioteca Universitaria di Pisa  Avocent Matrix High Performance KVM  PNOZ mc1p - LC Automation  English - Thuraya  有限会社学遊舎 1/2 ページ ELECOM Mail News No.151 2009/06/19  Télécharger en PDF - Rugby Club Strasbourg  RPM f RPRfR.JP 0414 002 532 Biiiæsiriel 0 Ttmemaandefijks  Documentation PDF Fi-7260 - MACH Scanners & Solutions  登録組織遵守規則  