Eaton 9E6KI uninterruptible power supply (UPS)
Contents
1. 5 Technical data 9E10Ki 9E20Ki INPUT Nominal voltage Nominal voltage Vac 220 230 240 220 230 240 380 400 415 voltage Nominal frequency 50 60 26 41 16 82 28 82722 e7285 x1 due lt 8h for 90 of the charge Expandability and 240 240 nominal voltage of the 180Vdc 240Vdc 240Vdc 240Vdc Battery Box Charging current Not AMA 5 for XL versions only applicable OUTPUT s Nominal power 16000 Bypass line available activates the bypass Overload 105 lt load lt after 5 min then 110 continues to work Bypass line not available locks after 5 min Bypass line available activates the bypass Overload 110 lt load lt after 1 min then 130 locks after 1 min Bypass line not available locks after 1 min Bypass line available activates the bypass Overload 130 lt load lt after 10 s then 150 locks after 10 s 35 Bypass line not available locks after 10 s Bypass line available activates the bypass after 100 ms then Overload load 15096 locks after 1 s Bypass line not available locks after 1 s Leakage current to earth Humidity 95 without condensation daw aaa Batteries deep discharge overcurrent short circuit overvoltage undervoltage circuit breaker Dimensions WxDxH 262 x 613x 709 350 x 706 x 818 86 160 ET i Operating Temperature 0
2. sliding it off the pallet NOTE All parts of the packaging should be kept for future use 12 3 2 Package content After opening the packaging it is first necessary to check the contents The package must contain UPS Jumper 15 20kVA models only yan 3 3 Connection USB cable User manual User s 3 3 1 Installation requirements Warning RS232 cable Software CD Installation must be performed by qualified personnel The first connection to perform is the protective conductor earth cable which must be connected to the screw marketed The UPS when inserted in an installation does not alter the existing neutral system earthing arrangements 13 A differential switch upstream will also be triggered for a fault occurring downstream of the UPS In calculating reactivity of this switch account must be taken of the leakage current of the UPS approx 8 mA plus that of the load which come together on the UPS s earth conductor Single phase Type B or Type A Three phase Type B The neutral arrangements are altered only if there is isolating transformer or when the UPS operates with a neutral that is disconnected upstream In any case avoid connecting the output neutral with the input neutral or to the earth as this could
3. 10 20K single phase input terminal view 6 Tighten the terminals well close the backpanel cover and secure it with the screws taken out earlier For 10 to 15kVA the suggested tighten force is 1 2 1 6Nm For 20kVA the suggested tighten force is 2 5 3 Nm 18 Three phase connection 1 THREE PHASE CONNECTION 9E10KI 9E10KIXL Use 2 cables of cross section 4 mm L2 and L3 3 with cross section 10 mm EARTH L1 for the input N B L1 and N are of greater cross section because in bypass operation they have to carry all of the input current For the output use 3 cables of cross section 10 mm EARTH N and L THREE PHASE CONNECTION 9 15 9E15KIXL Use 2 cables of cross section 4 mm L2 and L3 and 3 of cross section 16 mm EARTH L1 for the input N B L1 and N are of greater cross section because in bypass operation they have to carry all of the input current For the output use 3 cables of cross section 16 mm EARTH N and L THREE PHASE CONNECTION 9 20 9E20KIXL Use 2 cables of cross section 6 mm L2 and L3 and 3 of cross section 25 mm EARTH N L1 for the input N B L1 and N are of greater cross section because in bypass operation they have to carry all of the input current For the output use 3 cables of cross section 25 mm EARTH N and L 2 Connect the wires to the respective terminals following exactly the instructions below Input line a Ensure that the upstream ma
4. damage the UPS Reminder The UPS needs a neutral connection to work properly Operation without Neutral may damage the unit For installation with change in system earthing arrangement or galvanic isolation see below schematic Main low Isolation voltage transformer switchboard MLVS 40 Normal Main low voltage switchboard 40 fe Normal AC Fig 3 1 Change in SEA or Galvanic isolation Isolation transformer Load 14 Notice It is required to install an external isolating device against current backfeed between Mains input and UPS After the device is installed it must add a warning label with the following wording or the equivalent on the external AC contactor RISK OF VOLTAGE BACKFEED Isolate the UPS before operating on this circuit then check for hazardous voltage between all terminals The current rating of T AC contactor should be more than 1 3 times of UPS capacity Single phase input Q L MAIN INPUT coil remote switch input main switch AC contactor line input neutral gt Three phase input Q T MAIN INPUT a B coil remote switch Q input main switch T AC contactor B L1 L2 L3 line input N neutral Fig 3 2 Typical external isolating device installation 3 3 2 UPS Wir
5. is turned Switch off all of the connected loads before turning off the UPS Notice Power on for the first time 1 Close the magnetothermic switch located upstream of the UPS 2 Close the input and output switches and insert the battery fuses if any located on the back of the UPS s backpack 4 2 1 Turning on UPS with mains Check that all connections are correct Check the breaker of external battery pack is in ON position Set input breaker in ON position At this time the fan begins to rotate By pressing button continuously for more than 2 second the buzzer will beep once UPS starts to turn on A few seconds later the UPS turns into Line mode If the mains power is abnormal the UPS will transfer to Battery mode without output interruption of the UPS 4 2 2 Turning on UPS without mains Check that all connections are correct Check the breaker of external battery pack is in ON position By pressing button continuously for more than 2s the buzzer will beep once UPS starts to turn on A few seconds later the UPS turns into Battery mode If the mains power comes back the UPS will transfer to Line mode without output interruption of the UPS 4 2 3 Turning off UPS with mains To turn off the inverter of UPS press button continuously for more than 3s and the buzzer beep once The UPS will turn into standby mode Cut off the mains power supply A few seconds later LCD display shuts down 28 4 2 4
6. marked PE yellow green The UPS generates a leakage current of over 3 5 mA The leakage current of the load should be added to that of the UPS on the protective earth wire The UPS needs a neutral connection to work properly Operation without Neutral may damage the unit A readily accessible disconnect device shall be incorporated in the building installation wiring for permanently connected equipment The UPS generates hazardous electric voltages inside it even when the input and or battery switches are open The inside of the UPS is protected by safety guards that are not to be removed by non qualified Staff All installation and maintenance or other operations that entail gaining access to the inside of the UPS require the use of tools and are to be performed exclusively by qualified staff The UPS contains an energy source the batteries All terminals and sockets may be powered even when the UPS is not connected to the mains The total battery voltage is potentially hazardous it may cause an electric shock The compartment containing the batteries is protected by safety guards which are not to be removed by non qualified staff 1 All battery installation and maintenance operations entail gaining access to the inside of the UPS and require the use of tools these operations are to be performed exclusively by qualified staff The batteries replaced are to be considered as toxic waste and treated accordingly Dispose of used batteri
7. the UPS is in line battery HE or battery test mode Turn off press gt 35 the buzzer will beep once then the UPS will be turned off If the UPS is in fault mode and the fault cause has Transfer disappeared press gt 2s the buzzer will beep once fault will be cleared and UPS will turn to standby mode Battery test on line mode Press the button gt 2s OF Function key Mute Press the button gt 2s Down to next page Press the button lt 200ms 24 Table 4 2 LED indicator It indicates the input is connected with battery and the Battery Yellow input power is supplied from the battery It indicates the UPS is in bypass mode the load current Bypass Yellow is directly supplied from the utility power It indicates that the inverter is OK and the load is Inverter Green supplied from the inverter Note After UPS power on all LEDs will be lightened for 2 seconds and then turn to normal status When UPS is turning on 4 LEDs will be lightened one by one until the UPS is turned on successfully NoOutputmode o Bypassmode e J e J lima e J Jl Qe e Peattery mode s w s i 9 awe s s 5 Utility is normal e Lightened constantly Flashing every 4s Depended on the fault status o Depend on the original display 25 Table 4 3 Buzzer Battery battery test mode
8. 16KW Combo 08 230 220 240 9EEBMI80 ForoEBKi 1 180V 0 9EEBM240 For 9E10Ki 9ETOKXL _ 240V XL Model Model with internal supercharger and without internal batteries Other models with internal batteries 2 2 Electrical structure 9E6Ki 9E10Ki Main power wiring Input Switch lhintain Switch 20 INPUT Output L3 e in filter N D N OUTPUT Output LO Switch Battery 9E15Ki 9E20Ki 9E2OKIXL Main power wiring Input Switch L1 7 c aintain Switch L2 INPUT Output L3 filter N N OUTPUT L power 2 3 UPS views 2 3 1 UPS Front view ge OOE 1 Display 2 Multipurpose buttons 3 Wheels front wheels swivel and can be locked fixed rear wheels 2 3 2 UPS Rear view CQ 6 9 9E6Ki With backpanel cover USB communication port RS232 communication port olot for optional communication card Cooling fan s Output switch Manual bypass for maintenance 9E10Ki 9E10KiXL With backpanel cover 9E6Ki Without backpanel cover Ree Input switch I Cover for terminals 2 Fuse B Terminals for I O cable connection refer to related section Earthing screws 45 Tie wrap hold down 9E10Ki 9E10KiXL Without backpanel cover 8 CQ 9 USB communication port RS232 communication port Slot for optional communicati
9. C Disconnect all the utilities switch the UPS off and back on again reconnect the utilities one at a time to identify which one is faulty If possible disconnect the power to the load switch the UPS off and back on again if the problem occurs again call the support centre To take the UPS out of the maintenance bypass function open the manual bypass switch on the back of the UPS 4 5 Alarm codes Using a sophisticated self diagnosis system the UPS is able to check its own status and any anomalies and or faults which may occur during normal operation and display them on the display panel If there is a problem the UPS signals the event by showing the code and the type of active alarm on the display Alarms Minor problems which reduce performance or prevent certain functions from being used Unbalanced input voltages three phase input A806 E P O control active Faults Faults are normally preceded by an alarm signal and their scale leads to the power off of the inverter and the load being powered by the bypass line roa Dissipator over temperature Faoz F03 Capactor bank undewotage Fara Capacitor bank overvotage U FR F Faledcapsctorbanksoftstqt Lr 34 F704 Failed inverter soft start F70C Inverter undervoltage F808 Output overload fault 811 O Negative output power
10. C to 40 C Operating humidity 0 95 no condensing Altitude Mn 000 meters above sea level with 10 derating per S 15 C to 60 C without batteries 0 35 C with batteries EM i8VDCoAh 2 36 3 38 614 06847 03
11. ON Use 3 cables with 10 mm section Earth N and 2 Connect the wires to the relative terminals following exactly the instructions given below For 9E6Ki 9E10Ki 9E10KIXL a Make sure that the fuse holder of the external battery box is open b Connect the earth PE wire to EBM s earth PE screw c Connect the positive branch wire to EBM s positive terminal d Connect the negative branch wire to EBM s negative terminal The suggested tighten force is 1 6Nm Detailed wiring diagram see fig 3 9 10 gt 2 4 x x PAN i odre i BATTERY EXTENSION fi C LA P Fig 3 8 EBM terminal view Fuse for 9E6Ki 9E10Ki 9E10KiXLwithout Neutral 22 Versions 9E6Ki 9E10Ki 9E10KiXL Fig 3 9 EBM terminal connection for 9E6Ki 9E10Ki 9E10KiXL With Single EBM Fig 3 10 EBM terminal connection for 9E6Ki 9E10Ki 9E10KiXL With Mutliple EBM Note For 9E15Ki 9E20Ki 9E20KiXL EBM wiring connection you should check the 9EEBM manual in EBM package 23 4 4 1 Display and Buttons Fig 4 1 Control Panel The following tables shows the buttons LCD indicator and LED indicator status and description Table 4 1 Control Buttons Functions The Button Function If the UPS is in standby or bypass mode press gt 2s Turn on the buzzer will beep once then the UPS system will be turned on If
12. One beep per 4 sec One beep 1s when battery low Note buzzer alarm can be enable disable by function button if buzzer alarm is disabled all present alarm is muted except that the button press still has a tick beep Buzzer alarm will be enabled automatically once new alarm arises Interface In order to make sure all segments are OK LCD begins to do self test after power on During self test all the segments will be lighted for 2 seconds then the LCD will turn to normal display status ee OUTPUT LOAD c BATTERY Fig 4 2 The default LCD display 26 name Description Measureme Display values eg voltage J nts frequency load percentage etc VDC DC Voltage Battery voltage The percentage eg Load percentage and battery capacity Percentage percentage TN It indicates information for output ue It indicates information for input Load It indicates information for load Battery It indicates information for battery It indicates the load level Load border will flash if the load is overload It indicates the battery capacity Battery border will flash if the battery is low It indicates warnings or UPS Fault Warning Fau If it is a warning the icon will flash if It itis a fault the icon will be lighted constantly 27 4 2 Operating UPS Notice Please switch off the connected loads first before turning on the UPS and switch on the loads one by one after the UPS
13. Turning off UPS without mains To power off the UPS press D button continuously for more than 3s and the buzzer beep once The UPS will cut off the output A few seconds later LCD shuts down and no voltage is available from the UPS output 4 2 5 Transfer to Bypass To transfer the UPS in internal bypass mode press on off button and test button at the same time for more than 4 seconds To transfer the UPS back to normal mode press on off button and test button at the same time for more than 4 seconds 4 2 6 Transfer to maintenance Bypass To transfer the UPS in maintenance bypass mode switch on the maintenance switch And then the UPS will transfer to maintenance bypass mode Switch off the input and output switch before doing maintenance on the UPS To transfer the UPS back to normal mode switch on the input and output switch and then switch off the maintenance switch Then turn on the UPS following Turning on UPS steps 4 2 7 Transfer to manual Bypass Press the on off button and function button continuously for 4s the UPS will transfer to manual bypass mode If execute manual bypass operation when the UPS is working on ECO mode the UPS will transfer to bypass output mode If press the on off button again to clear manual bypass the UPS will not transfer back to ECO mode and will stays in bypass output mode Only when ups working in line on mode before executing manual bypass operation UPS will auto restart to line mo
14. addition a Environmental Monitoring Probe can be atta ched to obtain humidity temperature smoke alarm and security information e Modbus MS card has connection to Modbus protocol in addition to network management e Relay MS card has isolated dry contact Form C relay outputs for UPS status Utility failure Battery low UPS alarm OK or on Bypass 4 3 8 Eaton Intelligent Power Software suite 31 Each 9E UPS ships with Eaton Intelligent Power Software suite To begin installing see the instructions accompanying the Software suite CD Eaton Software suite provides up to date graphics of UPS power and system data and power flow also gives you a complete record of critical power events and it notifies you of important UPS or power information If there is a power outage and the 9E UPS battery power becomes low Eaton Software suite can automatically shut down your computer system to protect your data before the UPS shutdown occurs 4 4 Trouble shooting PROBLEM POSSIBLE CAUSE SOLUTION INPUT SWITCH Close the input switch located on OPEN the back of the UPS Check that the power cable is CABLE MISSING connected correctly THE DISPLAY DOES NOT LIGHT UP Check that the power reaches the BLACKOUT oe UPSTREAM Reset the thermal protection THERMAL CAUTION Check that there is no PROTECTION TRIP output overload the UPS THE DISPLAY IS ON BUT THE LOAD IS NOT POWERED THE UPS IS IN Press
15. de after clearing the manual bypass operation 29 4 3 Configuration 4 3 1 UPS parameters In order to change UPS parameters Output Voltage Number of EBM please use UPS Configuration Tool download available here http ogsoftware eaton com 4 3 2 Communication ports On the back of the UPS see UPS Views the following communication ports are present RS232 connector USB connector Slot for optional connectivity cards RS232 or USB communication ports The RS232 and USB communication ports cannot operate simultaneously 1 Connect the RS232 or USB communication cable to the serial or USB port on the computer 2 Connect the other end of the communication cable to the RS232 or USB communication port on the UPS The UPS can now communicate with EATON power management software 30 Connectivity Cards The UPS is equipped with an expansion slot for optional Connectivity Cards see figure on right is not necessary to shutdown the UPS before installing a communication 1 Remove slot cover secured by screws 2 Insert the communication card in the slot 3 Secure the card cover with the 2 screws Connectivity cards allow the UPS to communicate in a variety of networking environments and with different types of devices Network MS card has SNMP and HTTP capabilities as well as monitoring through a Web browser interface connects to Ethernet network In
16. en a contact is closed a maximum current of 15mA circulates All connections with the remote control terminal board are made through a cable which guarantees a double insulation connection If you would like to bring the R E P O control outside unscrew the two screws securing the lower part of the backpanel cover and remove it as indicated in the section Connections Then proceed as follows 20 1 Use a 2 0 75 cable to make the connection with the R E P O terminals 2 Insert the screw driver in the square hole and press down to make the round hole terminal open Then insert the wire into the round hole Then pull out the screw driver Connect the two wires of the cable to terminals 5 and 6 for version 9E6Ki 7 and 8 for versions 9E10Ki 9E10KiXL 9E15Ki 9E15KiXL 9E20Ki 9E20KiXL to be able to remotely shut off the UPS 9E10Ki 9E10KiXL 9E15Ki 9E6Ki 9E15KiXL 9E20Ki 9E20KiXL Fig 3 7 EPO terminal connection 3 Close the backpanel cover and secure it with the screws taken out earlier 21 3 3 3 EBM Wiring Connection is possible to connect more than one EBM in order to achieve any level of autonomy without mains power In order to ensure the battery runtime displayed is accurate please set your battery configuration through UPS Configuration Tool download available here http pqsoftware eaton com Connect any Battery Boxes in a cascade as shown in the figure below 1 CONNECTI
17. es according to the instructions Do not throw the batteries into fire they could explode Do not attempt to open the battery casing no maintenance work can be done on them In addition the electrolyte is hazardous for the skin and eyes and may be toxic Risk of explosion if battery is replaced by an incorrect type Do not turn on the UPS if you see any leaks of liquid or a white powder residue Make sure that no water liquid in general and or other foreign matter gets inside the UPS Under hazardous conditions turn off the UPS at the 1 0 main power switch and open all the isolators present see the user manual to locate the 1 0 main power switch and the isolators Do not open the battery fuse holders while the UPS is powering the load from the batteries An interruption of the battery DC voltage may cause an electric arc and result in breakage of the equipment and or fire The energy required to power the load is provided by the batteries in the event of a power failure if the battery protection were open the load would be powered off Fuses have to be replaced with the same type if necessary To connect external battery cabinets use the expansion cable suggested by the manufacturer in this manual 1 2 Certification Standards Safety IEC 62040 1 2008 IEC 60950 1 2005 Modified Conducted Emission 62040 2 Category Radiated Emission 62040 2 Category C3 ESD IEC 61000 4 2 Contact L
18. evel 2 Air discharge Level 3 RS IEC 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 Surge IEC EN 61000 4 5 Level 4 CS IEC EN 61000 4 6 Level 3 MS IEC EN 61000 4 8 Level 3 Voltage Dips short interruptions and voltage variations IEC EN 61000 4 1 1 Warning This is a product for commercial and industrial application in other environment installation restrictions or additional measures may be needed to prevent disturbances Additional curbs may be needed while output wiring length is more than 10m or communication wiring length is more than 3m 1 3 Special Symbols The following are examples of symbols used on the UPS or accessories to show you the important information Symbol and Explanation Symbol Explanation Symbol Explanation Alert you to pay Direct ey special attention source Caution of high Turn turn off the UPS ecycie Alternating current Do not dispose with source AC ordinary trash 2 Presentation 9E series UPS uses ON LINE double conversion technology resulting in the highest levels of reliability and maximum protection for critical loads 2 1 Model List Model PowerRatings _ 230v 220240 9 1XVAGKW Combo 08 280v 20 240 SEOKXL 1XVAGKW Combo 08 230V 220240 9E15Ki 15kVA 12kW Combo 08 230V 220 240 _ 9E20Ki _ 20kVA 16kW Combo 08 230V 220 240 _ 20KVA
19. gneto thermal switch is open b Connect the earth wire to screw A c Connect the neutral wire to terminal 4 d Connect the wires of the phases to terminals 1 2 and 3 for L1 use red wire Output line a Connect the earth wire to screw B b Connect the neutral wire to terminal 5 c Connect the live wire to terminal 6 R E P O The REPO connection between terminal 5 and 6 is normally open For more information please refer to the REPO section of this manual 19 IN OUT L1 L2 L3 N N L 4 5 6 TTT of of of of of of Fig 3 6 10 20K three phase input terminal view 3 Tighten the terminals well close the backpanel cover and secure it with the screws taken out earlier For 10 to 15kVA the suggested tighten force is 1 2 1 6Nm For 20kVA the suggested tighten force is 2 5 3 Nm R E P O The terminal block on the back of the UPS also implements the R E P O Remote Emergency Power Off function that can be used to shut off the UPS remotely in case of an emergency For installation connect to the device s normally open contact In case of an emergency if the stop device is used the REPO control is closed and the UPS goes into stand by mode and the load is completely disconnected Attention before restarting the UPS reset the stop device The circuitry of the remote control terminal board is self powered with SELV circuits Therefore an external voltage supply is not required Wh
20. ing Connection To make the mains power and load connections follow the instructions below 15 1 Install a magneto thermal switch 63A for 6 amp versions 125A for 15 and 20kVA versions with intervention curve D upstream of the machine 4 poles for three phase versions 2 poles for single phase versions 2 he connection terminals to use for the input and output lines are located on the backpanel Unscrew the 4 screws located on the sides of the cover one on each side see figure 3 Remove the backpanel cover see figure to the side Fig 3 3 Wiring connection Single phase version 9E6Ki only 4 SINGLE PHASE CONNECTION 9 6 use cables with cross section 6 EARTH N and L for the input and 3 cables with cross section 6 for the output EARTH N and L 5 Connect the wires to the relative terminals following exactly the instructions given below Input line a Make sure that the magneto thermal switch upstream is open b Connect the earth wire to screw A c Connect the neutral wire to terminal 2 d Connect the live wire to terminal 1 Output line a Connect the earth wire to screw B b Connect the neutral wire to terminal 3 c Connect the live wire to terminal 4 16 R E P O The REPO connection between terminal 5 and 6 is normally open For more information please refer to the REPO section of this manual Fig 3 4 6K terminal view 6 Tigh
21. on card Cooling fan s Output switch Manual bypass for maintenance E oo0000 oo0000 oo000 00000 Input switch I Cover for terminals 42 Fuse B Terminals for I O cable connection refer to related section Earthing screws i Tie wrap hold down UPS Rear view 9E15Ki 9E15KiXL 9E20Ki 9E20KiXL 9E15Ki 9E15KiXL 9E20Ki 9E20KiXL With backpanel cover Without backpanel cover RS232 communication port Input switch USB communication port 17 Cover for terminals Slot for optional D Terminals for I O cable connection communication card refer to related section Cooling fans i3 Earthing screws Output switch Fuse Manual bypass for maintenance Tie wrap hold down 2 3 3 EBM Rear view amp Fuse Cover for terminals Tie wrap hold down Wheels front wheels swivel and can be locked fixed rear wheels Terminals for I O cable connection refer to related section Earthing screws 11 3 Installation 3 1 Unpacking 1 Cut the straps 2 Open the carton take off wood board accessory pack and PE form 3 Remove carton upward and take out front PE form 4 Put the wood board removed at step2 as figure showed Make sure that the slide rests firmly against the pallet so it remains in place during unloading operations Pull the UPS from the front with caution when
22. powerquality eaton com Eaton 9E 6 20kVA Powering Business Worldwide CONTENT ERREUR 1 1 1 Galery INSTRUCT OM et ot N 1 1 2 Certification Standards 3 1 3 Special Symbols usu Do qd ees dme PU ads 4 2 Presema on meet PUT 5 21 Model biSLUyu u unu DN un tue De OM e 5 2 2 Electrical SIrUGIUIG iuo EDS MEAM MEME 5 2 JP VIEW S PEN S8 Installation mem suu u 12 SmMSeriedjeMe E 12 3 2 Package Gonilef il estas tub Dus 13 9 9 OOhHecllOl QUUD 13 OPERATION u u au caue masus de edat 24 4 1 Display and Buttons 24 4 2 Operating PS itio aea oeste eue n eoe 28 4 9 GOMNGUT ANON mana 30 4 4 Trouble shooting 32 4 34 5 RESTE 35 1 Introduction 1 1 Safety instruction The UPS must be installed and maintained exclusively by quailified Staff See installation and operation instructions before connecting to the supply The UPS must be installed with an earth connection It has a high leakage current The first wire to be connected is the earth wire which must be connected to the terminal
23. ten the terminals well close the backpanel cover and secure it with the screws taken out earlier The suggested tighten force is 1 2 1 6Nm Combo version Single phase connection 4 SINGLE PHASE CONNECTION 9E10Kl 9E10KIXL use 3 cables of cross section 10 mm EARTH N and L for the input and 3 cables of cross section 10 mm for the output EARTH N and L SINGLE PHASE CONNECTION 9E15Kl 9E15KIXL use 3 cables of cross section 16 mm EARTH N and L for the input and 3 cables of cross section 16 mm for the output EARTH N and L SINGLE PHASE CONNECTION 9 20 9E20KIXL use 3 cables of cross section 25 mm EARTH N and L for the input and 3 cables of cross section 25 mm for the output EARTH N and L 17 5 Short circuit the input terminals 1 2 and 3 with the jumper provided in the accessories kit Connect the wires to the respective terminals following exactly the instructions below Input line a Ensure that the upstream magneto thermal switch is open b Connect the earth wire to screw A c Connect the neutral wire to terminal 4 d Connect the live wire to terminal 1 Output line a Connect the earth wire to screw B b Connect the neutral wire to terminal 5 c Connect the live wire to terminal 6 R E P O The REPO connection between terminal 5 and 6 is normally open For more information please refer to the REPO section of this manual l j Fig 3 5
24. the ON button on the front Standby mode panel to power the loads THE INPUT VOLTAGE IS Problem with the mains Wait until OUTSIDE THE the input mains voltage returns PERMITTED within the tolerance range The TOLERANCE UPS will automatically return to RANGE FOR MAINS mains operation OPERATION DESPITE THE PRESENCE OF MAINS VOLTAGE 32 THE BUZZER SOUNDS CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES A80E A810 F808 THE DISPLAY SHOWS THE FOLLOW CODE CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES F704 F70D F70C F302 F303 F305 F300 F301 5 304 F002 THE DISPLAY SHOWS THE CODE A900 THE LOAD APPLIED TO THE UPS IS TOO HIGH BATTERIES MISSING OR BATTERY BOX MISSING OR NOT CONNECTED THE TEMPERATURE INSIDE THE UPS IS TOO HIGH THERE IS A FAULT ON ONE OR MORE OF THE LOADS POWERED BY THE UPS THE UPS 15 MALFUNCTIONING THE MAINTENANCE BYPASS FUNCTION IS ACTIVE 33 Reduce the load to within the threshold of 100 or user threshold in the case of code A80E If the display shows an Fault remove the load and switch the UPS off and back on again Check that the Battery Box is inserted and connected to the UPS correctly Check that the temperature of the environment in which the UPS is located does not exceed 40