Home

Tycon Systems UPS-ST12-50 uninterruptible power supply (UPS)

image

Contents

1. 24VDC Four Battery 48VDC Four Battery STEP 8 If batteries are installed on their side make sure to apply an insulator to the top of the battery termi nal to prevent the battery terminals from shorting to the metal enclosure in case the battery shifts inside the en closure during an earthquake STEP 9 Set the proper voltage on the AC input of the controller by removing the metal tab and then switch ing the input voltage to 120VAC or 240VAC depending on your source voltage Be sure to replace the metal tab to ensure that somebody doesn t accidentally switch the voltage as this will damage the controller STEP 10 Connect the battery cables to the controller then to the battery Be sure to observe proper polarity Black wire connects to bat tery negative terminal and BATTERY terminal on the controller STEP 11 When a battery is connected properly the BATT LED will be green Make sure that the Battery Type is selected correctly and never change the battery type during charging or this could damage the controller Use GEL for GEL or AGM batteries Use WET for standard lead acid wet cells Tycon recommends using only GEL or AGM batter ies for best performance The controller has battery overdischarge protection to disconnect the load if the battery voltage charge is too low The LOAD LED will be on when the battery charge is within safe limits and the LOAD output is turned on LED Indicators LOAD Load Power i
2. UPS ST12 24 48 Power UPSPro Backup Systems Power System Wireless Base Stations Surveillance Cameras Remote Gate Control Electric Fence Up to 192W loads Congratulations on your purchase of the UPSPro outdoor backup power system Please take a moment to review this Qwik Install Guide before assembly or battery installation DANGER Avoid Powerlines You Can Be Killed When following the instructions in this guide take extreme care to avoid contact with overhead power lines lights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder Recommended Tools Phillips Screwdriver 13mm and 10mm Open End Wrench 8mm nut driver Flat Blade Screwdriv X Please help preserve the environment and return used batteries to an authorized depot Qwik Install STEP 1 Add Grounding Wire Between Door and Enclosure Remove plastic covers on cop per studs on inside of door and inside of enclosure Add jumper wire between 2 copper studs and use copper
3. TPW 400DT 12 24 400W 12V or 24V Autovoltage se lect Wind Turbine Includes controller Good low wind perfor mance Self braking in high wind 80MPH survivability Sealed and maintenance free Limited Warranty The UPSPro products are supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external amp internal parts Products that have been opened altered or defaced Water damage for units that were not mounted according to user manual Usage other than in accordance with instructions and the normal intended use 8000026 Rev 2 UPS ST UPSPro Qwik Install Guide 8
4. load will turn on immediately as soon as AC power is re stored 2 CAPACITY The UPSPro UPS ST12 is rated at 144W load output 5 SPECIFICATIONS T12 UPS ST24 UPS ST48 Load Voltage 12V 105 24V 0 5 48V 41 05 Max Load 12A 144W BA 192W 4A 192 Min Load 1A 1A 1A Tbatiery STAR 600VA 2 battery 51Ah 2 battery 102Ah 1200VA 4 battery 51Ah Capacity 1200VA 4 battery 102Ah 2400VA 4 battery 204Ah 2400VA 2400VA Battery Type Valve Regulated Sealed Lead Acid GEL Battery Life 3 Years WET Equalize WET Equalize agvo zaa Pleas WET Equalize 13 2V 264V GEL Ean Charge Voltage GEL Equaize GEL Equalize GEL Equalize 14 24 Float 28 4V Float Aig 135V IV Over discharge 107V Loadot 21 5V Loadofi 40V Load Off protection 126V LoadOn 252V LoadOn 51V Load On VAC 10 Selector Switch 120VAC 240VAC 50 60Hz Input Current 3 5A 115VAC 1 8A 240VAC Enclosure Type Powder Coat Steel Operating 7 7 Tomp 30 C to 60 C The UPS ST24 and UPS ST48 are rated at 192W load output 3 VENTING The enclosure is vented thru the wire feedthrus and vari ous hole plugs in the bottom of the enclosure Don t make these airtight with silicon 4 BATTERY MAINTENANCE The batteries used in the UPSPro sys tems don t require any maintenance They should last up to 5 years in normal use Note Never store batteries for any length of time in a dis charged state o
5. r it will kill the battery 5 BATTERY OVERDISCHARGE We highly recommend hooking all equipment loads to the controller voltage output This output will dis connect the load if the battery voltage drops below the set voltage and this will protect the battery from over discharge If batteries get com pletely discharged because the equipment was connected directly to the battery you will reduce the battery life Discharged batteries will freeze at very low temperatures 6 ACCESSORIES Tycon also offers a variety of voltage conver sion products to meet almost any need Just visit tyconpower com for more info Compatible Solar Panel Kits Tycon Power Systems Solar Panel kits come with High Performance solar panels battery charge controller side of pole mounts and outdoor rated connection cabling Solar panels have a 25 year output warranty Pole mounts and panels are designed for wind loads to 90MPH Note Solar panel kits are only available for 12V and 24V Battery tpgkxx 85W xx choose 12 or 24 85W Sys Solar Panel Controller Pole Mount Cable tems TPSKxx 120W xx choose 12 or 24 120W Solar Panel Controller Pole Mount Cable TPSKxx 240W xx choose 12 or 24 240W Solar Panel Controller Pole Mount Cable Er Kits SHours Peak Sun Hours Peak Sun 3 Hours Peak Sun E ae continuous 10W continuous TPSKxx 120W 30W continuous 15W continuous TPSKxx 240W 60W continuous 30W continuous Compatible Wind Turbine
6. s Turned On Green PWR AC Power On Yellow BATT Battery is Connecter CHD Battery is Fully Charged Green CHG Battery is Charging Yellow WET GEL Switch is positioned to WET Green or GEL Yellow reen STEP 12 Switch off controller and connect AC to the controller Be sure to follow local regulations for outdoor 120 240VAC connec tions STEP 13 Connect the load to the controller LOAD terminals Be sure to observe proper polarity Switch on the controller to activate the charging STEP 14 Plug or Tighten all wire feedthrus If they don t tighten on a small diameter wire you can wrap some electrical tape around the wire in the seal area to increase its diameter and make a better seal The enclosure needs some small amount of venting so be sure NOT to seal all holes and feedthrus with silicon STEP 15 Make sure lid gasket is clean and free from any parti cles then carefully close the cover making sure that wires are clear of the seam and hinge area Use the special key to close the two cover locks TECH CORNER Additional Information you may find useful 1 CONTROLLER The controller tums off power to the load at 10 7V for the 12V model and 21 5 for the 24V model and 40V for the 48V model It reconnects when the battery reaches 12 6V for the 12V model and 25 2V for the 24V model and 51V for the 48V model This protects battery from overdischarge and increases battery life and performance Note The
7. washers and nuts to secure STEP 2 Add wire feedthrus into the bottom connector plate Attach the connector plate to the bottom of the enclosure using self tapping screws provided STEP 3 Install hole plug in drain hole in bottom right corner of the en closure STEP 4 If pole mounting the enclosure assemble the pole mount kit to the back of the enclosure and mount the enclosure to a pole using the 6 hose clamps provided The enclosure can also be wall mounted using the 4 holes in the back of the enclosure STEP 5 Insert the battery platform in the bottom of the enclosure The bat tery platform has cutouts so wires can be routed under the battery as needed STEP 6 Mount any extra equip ment that will reside inside the enclo sure Equipment can be mounted to removable backplate or to a plate mounted to the door rails STEP 7 Install the batteries in the enclosure If using multiple bat teries connect in parallel for 12V output or connect in series for 24V output 12V 200Ah battery configuration is shown here For 12V 100Ah two batteries are connected in parallel with Plus connected to Plus and Minus con nected to Minus For 12V 200Ah the 100Ah configuration is doubled with separate battery connection wires to controller 24V two battery and 24V and 48V four battery con figurations are shown be low Batteries are connect ed in series with Plus connected to Minus

Download Pdf Manuals

image

Related Search

Related Contents

Sony DSC-TX30/D Marketing Specifications  「エマ(E.M.A.)」 9月26日(金)  Sandberg Adapter AT-keyboard on PS/2  リモコン受発光ユニット  Un programa de calidad - New York State Afterschool Network  

Copyright © All rights reserved.