1. Installation and mounting manual for EK XRES D5 incl pump Series Reservoir This product is intended for installation only by expert users Please consult with a qualified technician for installation Improper installation may result in damage to your equipment EK Water Blocks assumes no liability whatsoever expressed or implied for the use of these products nor their installation The following instructions are subject to change without notice Please visit our web site at www ekwb com for updates Before installation of this product please read important notice disclosure and warranty conditions printed on the back of the box Before you start using this product please follow these basic guidelines 1 Please carefully read the manual before through before beginning with the installation process 2 The EK High Flow and EK PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o ring gaskets 3 The use of corrosion inhibiting coolants is always recommended for any liquid cooling system Unscrew the ribbed threaded ring that attaches the Laing pump s Install the EK XRES D5S on to the pump main motor housing Make original factory top and the main pump core housing with motor sure you install EK provided 61x3mm o ring gasket Reseat Store the original top the original o ring gasket and the attaching ring in a safe place the gasket if needed You can rotate the
2. as a result of using EK Water Blocks cooling products either due to errors or omissions on our part in the above instructions or due to failure or defect in the EK Water Blocks cooling products WARRANTY Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user During this period products will be repaired or have parts replaced at our discretion provided that I the product is returned to the agent from whom it was purchased II the product has been purchased by an end user and has not used for commercial purposes III the product has not been misused handled carelessly or used in a manner other than in accordance with the instructions provided describing its installation and proper use This warranty does not confer rights other than those expressly set out above and does not cover any claims for consequential loss or damage This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer This warranty is voided if the product comes in contact with aggressive additives or other improper liquids Any other RMA issues can be reported to http www ekwb com support for further analysis this paragraph is intentionally left blank REQUIRED TOOLS power drill with 4mm drill bit or equivalent optional Revision 1 0 Released on 18 of October 2012
3. iate position for the unit inside or perhaps outside of your computer chassis drill mounting holes if needed 2 Attach the EK UNI Holder D5 V2 to the computer chassis metal frame using enclosed M4x6 ISO7380 screws metal washers and a nut Secure the screws using enclosed Allen key 2 5mm 3 Screw in the four M4 threaded rubber dampers in to base of EK XRES D5 pump reservoir combo unit M4 nut 4 Attach the EK XRES D5 reservoir to the EK UNI Holder D5 V2 using washer four 4 M4x6 DIN7380 screws with plastic washers underneath each screw Secure the screws using enclosed Allen key 2 5mm Your installation is now complete Computer chassis metal plate M4 rubber damper EER ae TIP Some users might find installation of the assembly easier if steps 3 amp 4 are completed prior to completing step 2 Revision 1 0 Released on 18 of October 2012 EK XRES D5 incl pump series reservoir pump combo featured 3 three G1 4 threaded opening on the main body of which 2 two are inlets and one is outlet clearly marked with OUT EKWB recommends using EK CSQ fittings with the EK D5 Vario X RES CSQ series reservoir pump combo units To ensure that the tubes are securely attached to the barb fittings please use hose clamps or an appropriate substitute It is mandatory to use the correct INLET and OUTLET ports 1 The OUTLET port pressure port is the only port that is not recessed into the plastic housi
4. ng of the EK XRES D5 2 The INLET port s suction port are the two recessed ports with G1 4 threading on the EK XRES D5 front face plane You may use any of these two ports as an INLET port It is necessary to use the enclosed EK Extender G1 4 underneath the INLET fitting Please refer to the picture on the right Do not forget to close off the unused INLET port using EK Plug G1 4 3 Make sure not to use fittings or barbs with G1 4 thread longer than 5mm All EK PSC EK CSQ and High Flow fittings are compatible Jnl Ve genr TIP Port on reservoir s top part is not intended to be used as inlet port The dead y aforementioned port should should only be used for connecting this reservoir with external fill port E 6 a 6 a x e EK Extender G1 4 gt e earners t r i a s r a T ee tinn Tii eT e rrr ee ee VERY IMPORTANT NOTICE Once the installation is completed it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer We recommend a 24 hour leak test prior to powering up the computer Do not test the water block using tap water pressure This will rupture the top of the housing and render the block unusable and will void your warranty While all efforts have been made to provide the most comprehensive tutorial possible EK Water Blocks assumes no liability expressed or implied for any consequential damage s occurring to your equipment
5. pump and use it in any direction to best suit your installation Secure the EK XRES D5 using enclosed M4x16 DIN7380 screws with Factory original the enclosed Allen hex key Do not over tighten the screws as pump top excessive force may strip the threading EK XRES D5 D5 pump body with motor D5 pump body with motor 61x3mm sealing gasket OR Twist LEFT to unscrew EK XRES D5 series pump top reservoir comes preinstalled with Anticyclone by default In case your system suffers from excessive vortex issues air bleeding problems or if the pump is sucking in air you may replace the anticyclone with the enclosed polyether foam There are two ways to use the polyether anti vortex foam This is the default configuration of EK XRES Use the foam as a whole to replace the Trim the foam to size to fit into the desired inlet D5 series reservoir Anticyclone recess on the EK XRES D5 main body By default the EK XRES D5 ships with EK UNI Holder D5 V2 This holder is meant to be installed directly on the computer chassis User may need to drill 2 two 4mm holes through chassis metal using electric power drill if there are no appropriate mounting holes available EK recommends users to find an appropriate position in your computer chassis to install the EK XRES D5 pump assembly To sucessfully install the EK XRES D5 pump reservoir assembly to the EK UNI Holder V2 please complete the following steps 1 Find an appropr