Home

Da-Lite 24727LSR projection screen

image

Contents

1. INSTRUCTION BOOK FOR ViewShare Tensioned Advantage Electrol DA LITE Important Safety Instructions When using your video equipment basic safety precautions should always be followed including the following 1 2 Read and understand all instructions before using Position the cord so that it will not be tripped over pulled or contact hot surfaces If an extension cord is necessary a cord with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons Tools Required for Installation Pre Installation 1 2 Carefully unpack case from shipping carton Set aside the Installation Kit Items inside will be used during installation ake sure to recheck measurement of case for proper installation clearance Remove any protective foam covering the outside of the case For shipping purposes foam is also inserted between the roller brackets and endcaps Figure 1 Remove these foam blocks from the ends Remove the hanger brackets
2. he l Ground C Red used Therefore it is advised to wire the switch or provide a eee na 4 conductor connection that is accessible Green Data or Down White Blue Common b b b amp Power Input Brown Hot R UP UPDN GND 240VAC 50Hz 45V Green STOP Green 3 POSITION Ground to Case DOWN SWITCH RJ9 NOTE Ground Must be S39 g O Connected to Building 0000 Ground VOLE Splitter Front of Wall Back of Dry Contacts Switch Wall Switch 240V Wiring Diagram with Optional Built in Video Projector Interface A CAUTION The projector must be turned off before connecting the trigger wires to the projector Failure to do so may damage the controller 2 A ATTENTION Le projecteur doit tre teint avant de brancher les fils de d clenchement celui ci Tout manquement cette instruction pourrait endommager le contr leur 1 Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projectors 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projectors screen trigger output be Brown Hot 240VAC 50Hz Power Source Green Yellow Ground Blue Common sure to maintain the proper polarity The red wire from the VPI is the signal and the black wire from the VPI is the ground Connect the wires from the VPI that are labeled Low Voltage Connectiorr to the end of the
3. from the top of the case using a 1 2 wrench Do not discard the hardware it will be used during case installation to re attach the hanger brackets for mounting Case Installation 1 2 Open Wrench or Socket Driver 1 8 Hex Key included Hang case and attach to support structure with bolts See Suggested Methods of Installation Tighten bolts until trim flange is flush with ceiling NOTE For proper operation screen assembly must be level after installation Remove 2 screws to open junction box Install electrical connections that apply to your unit Make sure to review the wiring diagram for proper hook up Replace junction box cover and secure with 2 screws NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C221 and the National Electric Code NEC NFPA 70 If your case was ordered in advance of the screen and roller assembly your installation is now complete Continue to step 4 if your Tensioned Advantage Electrol was ordered as a complete unit Use supplied 1 8 hex key to remove silver shipping brackets attached to slat and screen case Test installation by running screen up and down a few times Be prepared to stop screen should any objects obstruct the movement of the screen To prevent damage to the motor the standard duty cycle is 1 minute on and 3 minutes off Suggested Methods of Installation Me
4. incoming electric line Blown fuse Replace fuse Tripped circuit breaker Reset circuit breaker Screen will not operate and motor does not hum Check above Tighten all loose wire connections Correct any improper connections No power to operating switch Down Position or junction Check for power across black and white leads Up Position Check for power across red and white leads Thermal overload tripped Let motor cool down for 15 minutes Try again Screen will not operate Broken wire in the down or up position Check for continuity Cut off old splice and reconnect and motor does not hum Power at junction box Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen does not sto Et P Limit switch out of adjustment See Screen Adjustment section at correct position Squeaking rubber end plug rubbing on motor Center roller in case Noise m 5 ena Grinding Foreign object in screen rubbing on roller NOTE Screen will operate E 9 9 i 9 Remove with a low pitched hum Se DUC Gear noise Replace motor assembly Coasting Defective brake Replace motor assembly Screen not installed properly Check for level and plumb Adjust down limit switch slowly until roller is exposed and Fabric hangs crooked Fabric has backed up inside case l i P wrinkle comes out then readjust for prope
5. 25 4832 E info da litecom www da lite com DL 0159 Rev 3 07 14 2014 Milestone AV Technologies LLC Printed in U S A 24954
6. aser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the above warranty period This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Sales Partners at PO Box 137 Warsaw IN 46581 0137 574 267 8101 800 622 3737 IMPORTANT THIS WARRANTY SHALL NOT BE VALID AND DA LITE BRANDED PRODUCTS SHALL NOT BE BOUND BY THIS WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANCE WITH THE DA LITE WRITTEN INSTRUCTIONS Keep your sales receipt to prove the date of purchase and your original ownership A Milestone AV Technologies Brand 3100 North Detroit Street Warsaw Indiana 46582 P 574 267 8101 or 800 622 3737 F 574 267 7804 or 877 3
7. can be used in place of the manquement cette instruction pourrait endommager supplied RJ 14 cable to connect the wall switch Connect the BUS le contr leur terminals on the wall switch to the corresponding BUS terminals on the splitter board Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projectors 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projectors screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable r Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Up Limit Tactile Button Down Limit Tactile Button Front of Back of Wall Switch Wall Switch Receptacle RJ 25 Jack Connection to Wall Switch RJ 45 Jack PAM Data White Green Ground Common Black Ground Must be Connected Hot to Building Ground Power Input 120VAC 60Hz 5 12 Volt Screen Trigger on Projector Wall Switch Installation for 220 240V Screens 240V Wiring Diagram ILT RJ 9 Pin Outs Tab Is Facing Up IMPORTANT NOTE The wall switch is REQUIRED to make any ai N or Up lack limit switch adjustments EVEN if a third party control system is
8. e up button to move the screen upward If you press and let go of either the up or down buttons the motor will do a small jog in that direction for fine adjustment of the screen Once the desired position is reached turn the switch over press and hold the down tactile button until the LED on back of switch blinks red twice The down limit is now set CAUTION Do not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with 12 black at the top A ATTENTION N effectuez pas de r glage pour obtenir un d roulement sup rieur celui command Au moins 1 1 2 tour de toile doit tre maintenu sur le cylindre Ce cran est dot de s rie d une bande noire sup rieure de 30 5 cm 12 po NOTE If the screen is in limit set mode and no buttons are pushed for 20 seconds the LED on the back of the wall switch Screen Adjustment for 220V 240V Screens will turn off the motor will return to run mode and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment 4 Toadjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns solid green This will put the motor in limit set mode Turn the wall switch over and use the up button on the front of the switch Press and hold the up button until the desired up position is reac
9. extended screen trigger wires above IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Green Yellow Ground Brown Down Blue Common Black Up Front of Wall Back of Switch Wall Switch 5 12 Volt Screen Trigger on Projector Camera and Speakerphone Installation The following components are necessary for camera and speakerphone installation Included e Local CATS to USB Extender with Power Supply 6 USB Cable USB Speakerphone e Powered USB Hub You also will need enough CAT5 or CAT5e network cable to run from the ViewShare Advantage to the Local CAT5 to USB Extender THE CAT5 CABLE IS NOT PROVIDED The length of the CAT5 cable cannot exceed 200 feet For computer system requirements specifications and troubleshooting see the separate camera instruction located in the Installation Kit and the Speakerphone instruction located inside the Speakerphone box Additionally links to online assistance for each device are located in the Troubleshooting section of this instruction book Video Cable to Projector 6 USB Cable 120 Volt Power USB Hub Local CAT5 to USB Extender Connections see wiring diagram below 1 Plug your CATS cable into connection port located on the left end o
10. f the ViewShare Advantage Figure 1 2 Connect your CAT5 cable to the Local CAT5 to USB Extender which should be located near your computer Connect the Local CAT5 to USB Extender power supply at this time NOTE The CAT5 cable should only be connected between the ViewShare Advantage and the Local CAT5 to USB Extender Do not connect to a server or network 3 Lower the ViewShare Advantage screen and note the camera location in the center of the slat bar Figure 2 4 Usethe 6 USB Cable to connect the Local CAT5 to USB Extender to the USB Hub 5 Connect the Speakerphone to the Powered USB Hub 6 Connect the USB Hub to your computer Connect the USB Hub power supply at this time NOTE The computer may recognize the USB Hub as a new component but It does not require any additional drivers The USB Hub does not need to be used if your computer has two open USB ports Laptop CAT5 Connection To Screen 120 Volt Power Powered b USB Speakerphone Camera and Speakerphone Installation continued Camera and Speakerphone Setup You are now ready to run the initial camera setup The computer If the LED does not turn green after install your computer may will recognize the camera as a new component and load the need to be restarted before the camera can be used This could appropriate drivers This can take up to several minutes and you be a result of the type of operating system and other hardwa
11. hed If you travel too far up press the down button to move the screen downward If you press and let go of either the up or down buttons the motor will do a small jog in that direction for fine adjustment of the screen Once the desired position is reached turn the switch Over press and hold the up tactile button until the LED on back of switch blinks green twice The up limit is now set CAUTION Adjusting the down limit switch by more than 6 can cause the screen surface to lose proper tensioning A ATTENTION Le fait d ajouter plus de 15 cm 6po aux interrupteurs de fin de course peut faire perdre la bonne tension a la surface de l cran 5 To test the limit switch settings press and release the up or down buttons on the switch to operate the screen 6 Replace the switch and cover plate on the wall IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments even if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible 1 Remove the cover plate from the 3 button wall switch and remove the switch from the junction box 2 Locate small 3 position switch on back of wall switch See Figure 5 for 120V screens or Figure 8 for 220 240V screens 3 Toadjust the down limit switch slide the 3 position switch to the down position Press and hold the down bu
12. ptacle RJ 45 Jack va Data Cable n n F White Green Ground n Common Black Ground Must be Connected E Hot to Building Ground Power Input 120VAC 60Hz RJ 14 Pin Outs Tab Is Facing Up RJ 25 Pin Outs Tab Is Facing Up RJ 45 Pin Outs Tab Is Facing Up 12V Bus RP Data ___ White Bus RP Data RQ Data ___ Green RQ Data L 5V C Red e Co Ground Black Ground I RQ Clock Blue Manual 2 Brown 12V Blue Yellow L Bus RP Data Yellow Green RQ Data Green Red 5V Red Ground Black Black RO Clock Orange White Manual 1 Purple Supplied RJ 14 cable Standard RJ 25 can be used in place of RJ 14 cable Video Projector Interface Installation for 120V Screens Optional 120V Wiring Diagram with Optional Built In Video Projector Interface A CAUTION The projector must be turned off before IMPORTANT NOTE The wall switch is REQUIRED to make any connecting the trigger wires to the projector Failure to limit switch adjustments EVEN if a third party control system is do so may damage the controller used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible A ATTENTION Le projecteur doit tre teint avant de brancher les fils de d clenchement celui ci Tout 3 conductor 20 24 gauge wire
13. r drop Fabric is damaged Replace fabric Camera Support http www logitech com en us support webcam c930e business crid 405 amp osid 14 amp bit 64 Speakerphone Support http www jabra com supportJabra SPEAK 410 MS 7410 109 LIMITED WARRANTY VIEWSHARE PRODUCTS Milestone AV Technologies LLC warrants its Da Lite branded ViewShare products to the original purchaser only to be free from defects in materials and workmanship in accordance with the following warranty term A period of five 5 years for the Advantage screen and related components and A period of three 3 years for the ViewShare camera and related components The foregoing warranty will commence upon the date of purchase by the original purchaser and is expressly contingent upon the products being properly operated according to Da Lite s instructions and not damaged due to improper handling or treatment after shipment from the factory This warranty does not apply to equipment showing evidence of misuse abuse or accidental damage or which has been tampered with or repaired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall be to repair or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purch
14. re may need to follow on screen instructions If the computer is software installed and is not necessarily a faulty device using Windows 7 or later version the computer will automatically detect the camera choose the proper drivers and install the drivers without your input Once the green LED on the Local 2 Goto the options menu and select C93Oe under the video CAT5 to USB Extender is illuminated and the drivers are installed devices you are ready to use the camera 1 Open Lync Skype or other compatible video calling software NOTE The Da Lite bowtie around the camera will glow when the camera is selected If the window says No camera detected go back to the Connections section and check each step 3 In your software s options menu select Speakerphone 410 under the audio devices Installation is now complete and you are now ready to use your compatible video calling software p l ig Figure 1 Figure 2 Troubleshooting Visit www da lite com products tutorials php to find installation You can contact us by email at info da lite com or by phone at and troubleshooting tutorials You will also find a link to Live Chat 800 622 3737 or 574 267 8101 with any additional troubleshooting for interactive support questions Symptom Cause Solution Verify 115 125V or 220 240V If insufficient voltage rewire Incorrect line voltage 3 Des
15. ter position Press and release the up or down button on the wall switch to operate the screen 8 Replace switch and cover plate on the wall NOTE If stop button is pressed the wall switch will reverse direction To correct this press the stop button again This will reset the switch You will have to re set both the up and the down limit settings IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible Wall Switch Installation for 120V Screens 120V Wiring Diagram 3 conductor 20 24 gauge wire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board Up Limit Tactile Button Down Limit Tactile Button Front of Wall Switch RJ 25 Jack Connection to Wall Switch Installation Video To view a video of this installation visit http youtu be t2ZO9PVAhEg or use the OR code below Wire IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible Up Dry Contact Down Dry Contact Common Both Bus Bus 5V Bus Rece
16. thod 1 Variable Position Mounting Bracket Electrical Junction Box Audience Side I 6 ig gt ih ncn rh e N lt Threaded Rod Not Included Attached To Mounting Bracket 6 Self Trimming m Flange Finished o 2 e Ceiling x Method 2 Threaded Rod Not Supplied Hanger Bracket 3 68 e e A x i 7 he 6 6 oo lt Screen Adjustment for 120V Screens If your Tensioned Advantage Electrol was ordered as a complete unit the up and down limits were pre set by Da Lite If your screen and roller assembly was ordered separately from the case or if general adjustment is needed please follow the steps below and refer to the 120V Wiring Diagram 1 Locate the wall switch and remove the cover plate from the wall switch and remove the switch from the junction box 2 Locate the two tactile buttons on the back of the switch They are black round buttons on silver plates See 120V Wiring Diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on the back of the switch turns solid red This will put the motor in limit set mode Turn the wall switch over and use the down button on the front of the switch Press and hold the down button until the desired down position is reached f you travel too far down press th
17. tton to run the screen down to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON A CAUTION Do not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with 12 black at the top See the specification data sheet for details A ATTENTION N effectuez pas de r glage pour obtenir un d roulement sup rieur celui command Au moins 1 1 2 tour de toile doit tre maintenu sur le cylindre Ce cran est dot de s rie d une bande noire sup rieure de 30 5 cm 12 po 4 When the screen is in the desired down position slide the 3 position switch to the off center position The down limit switch is now set 5 To adjust the up limit switch slide the 3 position switch to the up position Press and hold the up button to run the screen up to the desired stop position Release the button to stop the screen DO NOT PUSH THE STOP BUTTON A Caution Adjusting the down limit switch by more than 6 can cause the screen surface to lose proper tensioning A ATTENTION Le fait d ajouter plus de 15 cm 6po aux interrupteurs de fin de course peut faire perdre la bonne tension a la surface de l cran 6 When the screen is in the desired up position slide the 3 position switch to the off center position The up limit switch is now set 7 To test limit switch setting make sure the 3 position switch is in the off cen

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書(2.6MB)  INSTALLATION MANUAL - Rexel Energy Solutions  Anexo 2 - 1er Congreso sobre la Investigación en Facultades y  Product Flyer - Detroit R&D, Inc.  E LOGO! - Service, Support  Muvit MUSLI0013 mobile phone case  - Welotec GmbH  FR-0018 取扱説明書  SMA Bluetooth® Wireless Technology in practice - Gastech  RCA 25215 Specification Sheet  