Home
Supermicro SuperServer 6028R-TR
Contents
1. VCCPO 12v VR12 5 VR12 5 5 PHASE 5 PHASE 145W 145W 32 DES yn 2 3 FI Po P1 K 12 2 m p 23 m SNB CORE SNB CORE D DDR IV P1 PO DDRAV K S E N E Li NA NV SLOT 2 a 42 3A 1 3B DMI2 1 42 43 DZ x S 8 x um E I E o g SLOT3 PCI E X8 G3 LAN REVERSE dole Mee E x SLOT PCI E X8 G3 LAN REVERSE E e z T o 2 a SLOTS E PCI E X8 PCI E X8 G3 P SLOTA gj ran 8S X540 DMIZ olg 4GB s gj sLoTe 6 7 8 ha E i E 3 PCH EEN 2 LAN3 a pas UN IRGRMII cR INV RTL8211E VB CG 7 em DDR3 ins 45 SEI AST2400 2 Gen BMC Boot Flash USB 2 0 N 12 USB2 0 1USB 3 0 1 SPI H BIOS LPC I SPI COMI COM2 TPM HEADER BIOS Connector Header Debug Card HEADER Temp Sensor SYSTEM POWER FRONT PANEL FAN SPEED CTRL Chapter 1 Introduction 1 4 Contacting Supermicro Headquarters Address Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A Tel 1 408 503 8000 Fax 1 408 503 8008 Email marketing supermicro com General Information support supermicro com Technical Support Web Site www supermicro com Europe Address Super Mic
2. Ui Cab Rear I O Ports see Section 5 3 6 2 Control Panel The control panel located on the front of the chassis must be connected to the JF1 connector on the serverboard to provide you with system status indications A ribbon cable has bundled these wires together to simplify the connection Connect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 6 2 Chapter 6 Advanced Chassis Setup 6 3 System Fans Three 8 cm hot swap fans provide the cooling for the system It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components See Figure 6 2 System Fan Failure Fan speed is controlled by system temperature via IPMI If a fan fails the remaining fans will ramp up to full speed and the overheat fan fail LED on the control panel will turn on Replace any failed fan at your earliest convenience with the same type and model the system can continue to run with a failed fan Remove
3. Notes e Jumpers not indicated are for test purposes only and should not have their settings changed e p indicates the location of pin 1 e LAN1 LAN2 ports support Gigabit LAN connections on the X10DRi and 10G LAN connections on the X10DRi T 5 11 SUPERSERVER 6028R TR TRT User s Manual X10DRi X10DRi T Quick Reference Jumper Description Default Setting JBR1 BIOS Recovery Enable Disable Pins 1 2 Normal JBT1 Clear CMOS See Section 5 9 JPC1 JPC2 SMB to PCI E Slots Enable Disable Off Disabled JPB1 BMC Enable Disable Pins 1 2 Enabled JPG1 VGA Enable Disable Pins 1 2 Enabled JPL1 LAN1 LAN2 Enable Disable Pins 1 2 Enabled JPME2 Manufacture ME Mode Select Pins 1 2 Normal JWD1 Watch Dog Timer Pins 1 2 Reset Connector Description COM1 COM2 Backplane COM Port1 Front Accessible COM2 Header Fan1 6 FanA B CPU System Fan Headers J24 24 pin ATX Main Power Connector JD1 Speaker Power LED SIE Front Panel Control Header JIPMB1 4 pin External BMC PC Header for an IPMI Card JL1 Chassis Intrusion Header JOH1 Overheat LED Indicator JPI2C1 Power Supply SMBbus PC Header JPWR1 2 12V 8 Pin Power Connectors JSD1 JSD2 SATA DOM Device on Module Power Connectors JSTBY1 Standby Power Connector JTPM1 TPM Trusted Platform Module Port 80 Header JUIDB1 UID Unit Identification Button I SATA 0 5 SATA 3 0 Ports supported by Intel PCH S SATA 0 3 SATA 3 0 Ports supported by Intel S
4. EI THIS BBE TH Yt SE ER et B 4 10 Chapter 4 Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne la remplacer que par une pile de type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant iAdvertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bater a exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las bater as gastadas seg n las instrucciones del fabricante TIAN rona v epp R 7072 29901 172 299105 YW pis n130 nip D nn JI 013 DP 3102 129705 nx yon mimm 55 9399 v Pm moon pIo dhli Ania j y play dy Ul Jaial Als dal Ge phd dlia i dy adl A iriall AS Al A9 caus d US lll Le gl E gill Liu L dla 4S LA ci Lage G y Aerial ol ll Ca cual KE aa SHEA xxx Yen 29 930 AFAA 11 mele st UA AZAA AR RS GA SHS NAE aa ao Bur az Y Hal upep 4230 HEL US esr FAL n of Waarschuwing Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts m
5. 022231 0305 38 Pop TNE msn Dw 2197 pon nu 155 Yael bas y yo oly w ll Al A 5 y ABN jalo aren Ze pill ued Gas J 294 les ca Sa Aly gf agil JS Gia Lil U ssa d AAW PSs Wap sp see use dcs en A WEA AM DIAZ dads BE AAW ANTES ao or Waarschuwing Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen 4 7 SUPERSERVER 6028R TR TRT User s Manual Equipment Installation A Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Fan OD ix irt PLATERO BENE ATT NT ORO A ERA x Tc CAR NTOES AREA E A AB A A RATITO gt EE gt RARGH alll LAA AAS de Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention ll est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s 1 TAIN TPY May PO NY 1X 3135 DS pap ppnnd RWI 3292 now nm Steal a Lead asia y 8 al y Cale gall cis gall L any od ay ox H EUS da Edu GALO o AA BA wa EE MAS vua IFUN
6. Notes Chapter 7 BIOS Chapter 7 BIOS 7 1 Introduction This chapter describes the AMI BIOS setup utility for the X10DRi X10DRi T The ROM BIOS is stored in a Flash EEPROM and can be easily updated This chapter describes the basic navigation of the AMI BIOS setup utility screens Note For AMI BIOS recovery please refer to the UEFI BIOS Recovery Instructions in Appendix C Starting BIOS Setup Utility To enter the AMI BIOS setup utility screens press the Delete key while the System is booting up Note In most cases the Delete key is used to invoke the AMI BIOS setup screen There are a few cases when other keys are used such as F1 F2 etc Each main BIOS menu option is described in this manual The AMI BIOS setup menu screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note the AMI BIOS has default text messages built in Supermicro retains the option to include omit or change any of these text messages The AMI BIOS setup utility uses a key based navigation system called hot keys Most of the AMI BIOS setup utility hot keys can be used at any time duri
7. 7 15 SUPERSERVER 6028R TR TRT User s Manual Port 0 Port 5 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to replace a SATA disk drive installed on this port without shutting down the system The options are Enabled and Disabled Port 0 Port 5 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to start a COMRE SET initialization to the device The options are Enabled and Disabled Port 0 Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive sSATA Configuration When this submenu is selected AMI BIOS automatically detects the presence of the SATA devices that are supported by the PCH sSATA controller and displays the following items SSATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH sSATA controller The options are Enabled and Disabled Configure sSATA as Select IDE to configure an sSATA drive specified by the user as an IDE drive Select AHCI to configure an sSATA drive specified by the user as an AHCI drive Select RAID to configure an sSATA drive specified by the user as a RAID drive The op tions are IDE AHCI and RAID If the item above Configure sSATA as is set to AHCI the following items will display Supp
8. Chapter 4 Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geinstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area A Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations TI AU BR pb COL METI ARE LC gi dUScbZRUEUCU3 3 74r AB HL FERIA Y ID BEE GER TOMO LA SUT4 0 TER UL CO BAO pEedg Sms DLE rte CE DELE AI Pr DUE LB E PH FREE ao a are PRUE He e T BELT SIAE ERASE A A gt EA E E Je TR Be LAI BAA REEL NE e Warnung Diese Einheit ist zur Installation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich iAdvertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s une zone d acc s
9. 427 x 89 x 648 mm Weight 57 Ibs 25 9 kg System Cooling Three 8 cm system cooling fans System Input Requirements AC Input Voltage 100 240V AC auto range Rated Input Current 9 3 5A max Rated Input Frequency 50 to 60 Hz Power Supply Rated Output Power 740W redundant power Part PWS 741P 1R Rated Output Voltages 12V 61 7A 5Vsb 4A Operating Environment Operating Temperature 10 to 35 C 50 to 95 F 0 to 47 C 32 to 116 F with certain configurations workload environments Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A B 2 Appendix B System Specifications Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate B 3 SUPERSERVER 6028R TR TRT User s Manual continued from front
10. 5 2 Chapter 5 Advanced Serverboard Setup Figure 5 1 Control Panel Header Pins Groun 10 X FP PWRLED HDD LED o NMI O X o 3 3V o UID Switch NIC1 Link LED NIC2 Link LED O NIC1 Activity LED NIC2 Activity LED OH Fan Fail PWR Fail LED Power Fail LED UID LED o 3 3V O Reser Reset Button 5 3 I O Ports O pwR Power Button See Figure 5 2 below for the descriptions of the various rear I O ports Figure 5 2 I O Ports UO Ports COM1 Port USB Port 0 USB 2 0 USB Port 1 USB 2 0 IPMI LAN Port USB Port 12 USB 3 0 a A wo N 6 USB Port 13 USB 3 0 u LAN Port 1 8 LAN Port 2 9 VGA Port These are Gb LAN ports on the X10DRi and 10 Gb LAN ports on the X10DRi T 5 3 SUPERSERVER 6028R TR TRT User s Manual 5 4 Installing the Processor and Heatsink Warning When handling the processor package avoid placing direct pressure on the label area of the fan Notes Always connect the power cord last and always remove it before adding re moving or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a
11. Definition 1 Data 2 Ground 3 Clock 4 No Connection PWR LED Connector Pin Definitions Pin Setting Definition Pin 1 JD1 PIN1 Pin 2 FP_PWR_LED Pin 3 FP_PWR_LED Speaker Connector Pin Settings Pin Setting Definition Pin 4 P5V Pin 5 Key Pin 6 R_SPKPIN_N Pin7 R_SPKPIN Chapter 5 Advanced Serverboard Setup Universal Serial Bus USB Backplane USB FP USB 4 5 6 USB 0 1 2 3 Pin Definitions Two USB 2 0 ports USB 0 1 and two Pin Definitions USB 4 6 USB 5 USB 2 0 3 0 ports USB12 13 are lo Pin Definition Pin Definition Pin Definition cated on the I O backpanel Note that 4 5V 1 5V 1 5V USB ports 12 13 support both USB 2 PO 2 PO 2 PO 2 0 and 3 0 In addition two internal 3 PO SEDO 3 PO USB headers provides a total of four 4 Ground 4 Ground 4 Ground USB 2 0 connections USB 2 3 4 5 5 m S MG 5 Key NC No connection for front panel support A Type A USB connector USB 10 3 0 and a vertical SES PB pes Mie ih J USB connector J USB3 1 support 3 0 Pin Definition Pin Definition connections for front access cables 1 VBUS m not included See the tables for pin 3 SSH 4 CUm definitions 5 Sanne E Gem 7 GND DRAIN 8 D 9 D Serial Ports Serial com Port in Definitions Two COM connections COM1 amp Pan Denim CENA O
12. iet iii dla 2 1 2 9 Preparing for Setup tie E ee ee tre Does ede 2 1 Choosingia Setup LOCATION E 2 1 2 4 Warnings and Precautions ue en crece reciente N 2 2 Rack Precautions Server Preca tions e eet br eerte m C EP EE EUER EE Mx Pena 2 2 Rack Mounting Considerations sss 2 3 2 4 Installing the System into a Rack iine nectit eid ence 2 4 Separating the Sections of the Rack Hals 2 4 Installing the Inner Rail Extension isms riaan tiaia 2 4 Outer Rack Rails Chapter 3 System Interface 3 1 OVGIVIEW acier eot Uer to dota eee 3 1 3 2 Control Panel Buttons iecit tarda edo aa a 3 1 Table of Contents Nera P 3 3 ADD tices 3 3 o 3 3 34 Drive CaAMeG NEEDS e 3 3 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements soneenesoeeesneeeesrerennnsesrenreseesees 4 1 Warning De uti cia 4 1 Installation INSTT CtIONS circa ege reet ra enr nt rien 4 4 Circuit Breaker 4 5 Power Disconnection Warning irissen isir eiA 4 6 Equipment Installation cio 4 8 Restricted Area wii cis cnet eee e ARP n e e i TRE i 4 9 EA en ana aa a daraa oraes 4 10 Redundant Power SuppliSs cocoa 4 12 Backplane Voltage 2 ba Oe cete reed Seek ken gege 4 13 Com
13. SAN SATA POS raro EUN re eee eee 5 24 5 12 Installing SONWANE ios oie 5 25 SUPCMDOCIONO EE 5 26 5 13 Onboard Batleny citant atras 5 27 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive DEVICES corras 6 1 ize f dai 6 1 WM PACKING sc 6 1 6 2 Control Panel acciona dit 6 2 6 9 System F ANS ege ee deenen E det ege e ee Seege 6 3 System Fam Falle isis cct iere te ERE ri rote 6 3 Replacing System Farsi eese dedicar iia 6 3 6 4 Drive Bay Installaton bemoval AA 6 4 Accessing the Drive Boys nnne ennt 6 4 SATA Drive Installati n eei een 6 5 Hard Drive Backplarie sit Rias 6 6 DVD ROM Installation Optional 2 nr enses 6 6 6 5 POWER SUD DIV EE 6 7 Power Supply Failure isso es rr ento ER Eee tet ete ARTE 6 7 Removing Replacing the Power Supply een 6 7 Chapter 7 BIOS 7 1 tee ee m 7 1 1 2 Mam SOU EE te etes tento ie EE A ESES eee LUE 7 2 723 Advanced Setup Configurations rore ceteri 7 4 454 Evento uri dae 7 29 A A EU eret ett 7 31 y CNET eU i SC UNOS STET 7 34 LT BOOESCUINOS ices iine rs 7 35 D OMEN AVC eI oil ts 7 37 Appendix A BIOS Error Beep Codes Appendix B System Specifications viii Chapter 1 Introduction Chapter 1 Introduction 1 1 Overview The SuperServer 6028R TR TRT is a high end server comprised of two main subsystems the SC825TQ R740LPB 2U chassis and the X10DRi X10DRi T
14. aaa alas gs Y LA sac jal ld cj Ss A el Sl ge as al dal ONLY AUS ATI 5 casa 7A at e BANS RA olde AA st aA AAs MS SUT d BAe 202 AU WIS BE AA AAE amore quu Waarschuwing Deze eenheid kan meer dan n stroomtoevoeraansluiting bevatten Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken Backplane Voltage A Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing IVIVE VAF LORDS EGE EE TALI DS ITV LIC DO TVE ESPINAR HRAT RARE gt DEPTH HD Ns r1 LITA TR LAER ERE HECTMEIETSHA e Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung jAdvertencia Cuando el sistema esta en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenance 4 13 SUPERSERVER 6028R TR TRT User s Manual nen 5353 nnn rms 9192 3n v n y5n 91990 7212 7 2192 nn Pop nip max da sll cle Bag sell ABUSE si je LA Gye ha lua uel Jae Lead Ae yaa CS Chery A y 9 aie A 280 EH EA up FAY Backplane E AAF AH dl lt A JUA AMA dai d Soa W
15. x8x4x4 x8x8 x16 and Auto 10U1 00 PCle Port 3 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto 7 7 SUPERSERVER 6028R TR TRT User s Manual No PCle Port Active ECO Use this feature to select a workaround setting to implement the engineering change order ECO on the system when PCI ports are not active The options are PCU Squelch exit ignore option and Reset the SQ FLOP by CSR option PIOAT Configuration Enable I OAT Select Enable to enable Intel I OAT I O Acceleration Technology which signifi cantly reduces CPU overhead by leveraging CPU architectural improvements and freeing the system resource for other tasks The options are Enable and Disable No Snoop Select Enable to support no snoop mode for each CB device The options are Disable and Enable Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain trans actions to violate the strict ordering rules of PCI and to be completed prior to other transactions that have already been enqueued The options are Disable and Enable gt Intel VT for Directed I O VT d Intel VT for Direct I O VT d Intel VT for Directed UO VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI
16. 220V 20A Power Disconnection Warning A Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components EMUO RS VAF LAY BAS POMO NETO ALO RDA Y AICP ILA FAA VAFLOEPUET SN TOY ARDEN el Fi VA IND NT ET EU EGRET FEF ASS ERIN BI si FRU DOCS Ze PSC EIU FR FFAS TR EUR gt DH us nm ETT TERR re ERIC PEAT WEG ROLE EET UCAS ER AIR Warnung E B cs Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein das von den Spg Versorgungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift um Systemsbestandteile anzubringen oder zu entfernen 4 6 Chapter 4 Warning Statements for AC Systems jAdvertencia El sistema debe ser disconnected de todas las fuentes de energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me wad pponmombunn 525 nx Pon 09 99007 nmpn Yom 0997 ns pI v
17. DE HL RAAF 250V 204 aras GE a AER EIE BS UR PRESE EH ESE A DESEE Aa fe De D EDI ER pc A ATE ER AAW 250V 20A gt Warnung Dieses Produkt ist darauf angewiesen dass im Gebaude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt jAdvertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installation lectrique du local V rifiez que le courant nominal du dispositif de protection n est pas sup rieur 250 V 20 A RT v san xp nya 01322 npn Tan 99 15n02 17331 60VDC 20A 79 INT R NIN 22007 IPT 355 Dn 1037 4 oggi an EN Vadis y oe Ajlecul exe sde ales cue lo DH 20A 250VDC Oe Zell usl sli Shed assis Ol Oe adio 4 5 SUPERSERVER 6028R TR TRT User s Manual AX o 4x daa HAGAH AA AANA dao Aes wa AA JEg s BA WEA 250V E 20A 4AE 2 EE EEN Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan
18. IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entrainer des blessures ou des dommages corporels Avant de travailler sur un quipement soyez conscient des dangers li s aux circuits lectriques et familiarisez vous avec les proc dures couramment utilis es pour viter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de s curit traduites qui accompagnent cet appareil r f rez vous au num ro de l instruction situ la fin de chaque avertissement CONSERVEZ CES INFORMATIONS mmus nns mpn moan 155 wanwan nx vum nio YY PWYNT 320 9 by nma J7 nsa nmn n nn Dap oy Wwp mx v 9093 79922 012207 IN NIRV WI TTPA NWR MPD pasan ns IIT 18 Pena PRVI 7252 22015 8120 1900 DW n 190 Tip i530 PTRA 0222299 nan AN NIPAT 2199 181522 NDOT NN NP v 4 2 Warning Statements for AC Systems Agna Aj Las ef cuui o E Als u A jh uis ja ll Dal is Sil gall ge Anal Ll ale de Silane cel le Dans gf D A jg Sl liam iy sell M sch US Al ya paill lll d adil et FSA i rO o p fijo BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwings symbool betekent gevaar U verkeert in een situatie die lichamelijk letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de
19. SATA drive specified by the user as a RAID drive The options are IDE AHCI and RAID If the item above Configure SATA as is set to AHCI the following items will display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The options are Enabled and Disabled SATA Port 0 Port 5 This item displays the information detected on the installed SATA drive on the particular SATA port Model number of drive and capacity Software Preserve Support Port 0 Port 5 Select Enabled to enable a SATA port specified by the user The options are Disabled and Enabled Port 0 Port 5 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to replace a SATA disk drive installed on this port without shutting down the system The options are Enabled and Disabled Port 0 Port 5 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Enabled and Disabled 7 14 Chapter 7 BIOS Port 0 Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The op
20. The default setting is 60 Note Please reboot the system for the changes to take effect View SMBIOS Event Log This item allows the user to view the event in the SMBIOS event log Select this item and press Enter to view the status of an event in the log The following categories are displayed Date Time Error Code Severity 7 30 Chapter 7 BIOS 7 5 IPMI Use this feature to configure Intelligent Platform Management Interface IPMI settings BMC network col IPMI Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status This item indicates the status of the IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging support at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event logs after each system reboot The options are No Yes On next reset and Yes On every reset 7 31 SUPERSERVER 6028R TR TRT User s Manual When SEL is Full This feature allows the user to determine what the BIOS should do when the sys tem event log is full Select Erase Immediately to erase all events in the log when the system event log is full The options are Do N
21. The options are Enabled and Disabled NUMA Support Available when the OS supports this feature Select Enabled to enable Non Uniform Memory Access support to enhance system performance The options are Enabled and Disabled COD Enable Available when the OS and the CPU support this feature Select Enabled for Cluster On Die support to enhance system performance in cloud computing The options are Enabled Disabled and Auto P iSCSI Configuration This item displays SCSI configuration information iSCSI Initiator Name This item displays the name of the iSCSI Initiator which is a unique name used in the world The name must use the IQN format The following actions can also be performed P Add an Attempt P Delete Attempts gt Change Attempt Order 7 28 Chapter 7 BIOS 7 4 Event Logs Use this feature to configure Event Log settings gt Change Smbios Event Log Settings Change SMBIOS Event Log Settings This feature allows the user to configure SMBIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled If this item is set to Enable the following item will be available for con figuration Memory Corrected Error Enabling Available when the item abo
22. The products sold by Supermicro are not intended for and will not be used in life support systems medical equipment nuclear facilities or systems aircraft aircraft devices aircraft emergency com munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale B 4
23. dual processor serverboard Please refer to our web site for information on operating Systems that have been certified for use with the system www supermicro com In addition to the serverboard and chassis various hardware components have been included with the 6028R TR TRT as listed below e Two passive CPU heatsinks SNK P0048PS Three 8 cm system fans FAN 0126L4 One air shroud MCP 310 29001 0N SATA Accessories One SATA backplane BPN SAS 825TQ O P Eight drive carriers MCP 220 00075 0B One CD containing drivers and utilities One rackmount kit MCP 290 00053 0N Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server e Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com f you have any questions please contact our support team at support supermicro com 1 1 SUPERSERVER 6028R TR TRT User s Manual 1 2 Serverboard Features The SuperServer 6028R TR TRT is built around the X10DRi X10DRi T a dual pro cessor serverboard based on the Intel PCH C612 chipset and designed to provide maximum performance Below are the main features of the X10DRi X10DRi T See Figure 1 1 for a block diagram of the chipset Processors The X10DRi X10DRi T supports single or dual Intel E5 2600 V3 Series Socket R3 processors in LGA 2011 sockets
24. enables it to automatically sense and operate at a 100V 240V input voltage Power Supply Failure If either of the two power supply modules fail the other module will take the full load and allow the system to continue operation without interruption The PWR Fail LED will illuminate and remain on until the failed unit has been replaced Replace ment units can be ordered directly from Supermicro see contact information in the Preface The power supply units have a hot swap capability meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply module The backup power supply module will keep the system up and running while you replace the failed hot swap unit Replace with the exact same model see part number in the Appendix which can be ordered directly from Supermicro Removing the Power Supply 1 First unplug the AC power cord from the failed power supply module 2 Depress the locking tab on the power supply module 3 Use the handle to pull it straight out with the rounded handle Installing a New Power Supply 1 Replace the failed hot swap unit with another identical power supply unit 2 Push the new power supply unit into the power bay until you hear a click 3 Secure the locking tab on the unit 4 Finish by plugging the AC power cord back into the unit 6 7 SUPERSERVER 6028R TR TRT User s Manual
25. full Send a Start signal to start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Dis abled and Enabled Legacy OS Redirection Resolution Use this item to select the number of rows and columns used in Console Redi rection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST When the option Bootloader is selected legacy Console Redirection is disabled before booting the OS When the option Always Enable is selected legacy Console Redirection remains enabled upon OS bootup The options are Always Enable and Bootloader 7 23 SUPERSERVER 6028R TR TRT User s Manual SOL COM2 Console Redirection Select Enabled to use the SOL port for Console Redirection The options are Enabled a
26. operating systems that do not sup port legacy USB devices The options are Disabled and Enabled USB Transfer Time outs USB Transfer Time out This feature is used to set the USB time out value so that the tasks of USB control bulk and interrupt transfer can be performed during the time out period The settings are 1 second 5 seconds 10 seconds and 20 Seconds Device Reset Time out This feature is used to set the time out value for the USB mass storage device before a start commend is issued to this device This will provide the time needed for the system to detect the presence of the device The options are 10 Seconds 20 Seconds 30 Seconds and 40 Seconds Device Power up Delay Use this feature to set the maximum time allowed for a USB device to wait before it properly reports itself to the host controller The options are Auto and Manual 7 13 SUPERSERVER 6028R TR TRT User s Manual SATA Configuration When this submenu is selected AMI BIOS automatically detects the presence of the SATA devices that are supported by the Intel PCH chip and displays the fol lowing items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enabled and Disabled Configure SATA as Select IDE to configure a SATA drive specified by the user as an IDE drive Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a
27. port for hot plugging Set this item to Enabled for hot plugging support which will allow the user to replace an sSATA drive without shutting down the system The options are Enabled and Disabled SSATA Port 0 Port 3 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to start a COMRE SET initialization to the device The options are Enabled and Disabled Port 0 Port 3 sSATA Device Type Use this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive P Server ME Management Engine Configuration This feature displays the following system ME configuration settings General ME Configuration Operational Firmware Version Recovery Firmware Version ME Firmware Features ME Firmware Status 1 7 18 Chapter 7 BIOS ME Firmware Status 2 Current State Error Code Altitude This feature indicates the altitude of the platform this machine is located above the sea level The value is shown in meters If the value is unknown enter the number 80000000 MCTP Management Component Transport Protocol Bus Owner This feature indicates the location of the MCTP Bus owner Enter Os to all fields to disable the MCTP Bus owner P PCle PCI PnP Configuration The following PCI information will be displayed PCI Bus Driver Version e PCI Latency Timer PCI Latency Timer U
28. r serv n est possible qu en utilisant un outil sp cial un m canisme de verrouillage et une cl ou tout autre moyen de s curit 4 9 SUPERSERVER 6028R TR TRT User s Manual Dan 10 OY TTX Lg nova nmi nun 20 02347 ana vv asa mmn NN ppnny v 7121 51135 DPE 3292 ANVAK 75 A dll Ga jl ias ll ola yanadi qi iala Bla elata JAS ya bib Rana is el J pac ll Sa OL 5 pS Alas s el sf lide y J A ol axi RZ eeu FS ARE lR See Ae Tal Y 7 He 7g ek T E SAA G2 ases SAS AFAR Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling A Warning There is the danger of explosion if the battery is replaced incorrectly Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions iil MOR Viilise E ELST DIVE DIGIT BAO TET 450 ES RTM A AMES SE ET 180 6 Ze EH FEO BOUT UE RD COR CHE DTMAUT FEW BA FB2U SE HUS S eg BE EK EI PE eB TH ABI rot TRECE LAL oT Pee ile RY UH ERE H E e Fil Er ERA E AREER gt GE ALY S El EM HD rr al V
29. reboot the system from an EFI boot device after its initial boot failure Select Legacy Boot to allow the BIOS to automatically reboot the system from a Legacy boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function Select Enabled to allow the Watch Dog timer to reboot the system when it is inac tive for more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the system shuts down when the power button is pressed Select 4 Seconds Override for the user to power off the system after pressing and holding the power button for 4 seconds or longer Select Instant Off to instantly power off the system as soon as the user presses the power button The options are 4 Seconds Override and Instant Off Restore on AC Power Loss Use this feature to set the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last power state before a power loss The options are Power On Stay Off and Last State SUPERSERVER 6028R TR TRT User s Manual CPU Configuration gt North Bridge This feature allows the user to configure the settings for the Intel North Bridge FIIO Configuration EV DFX Device Function On Hide Features When this featu
30. von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexi n previstos o designados los cables y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables certificados que tienen UL o CSA se muestra en el c digo de otros dispositivos el ctricos que los productos designados por Supermicro solamente 4 18 Chapter 4 Warning Statements for AC Systems Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie Appareils lectrom nagers et de loi sur la s curit Mat riel interdit l utilisation de UL ou CSA c bles certifi s qui ont UL ou CSA indiqu sur le code pour tous les autres appareils lectriques que les produits d sign s par Supermicro seulement AC RnD o gt awn gums Wx AC PARNA mpbo 0 7232 VANWA W WIA NN OPP WR 18 top 01149 DID INN agn 18 525 992 vio gt au 129107 17913 TION OP mmo ppm Yawn 0922 sg sn z YY san xp Ow mp 0079 VDM 3805 CSA 2 18 UL 2 550157 005252 vinum 3292 TIP PIDIO vm YY mms ROW INN YAWN 131 99 TAY UL CSA Asi E SUT ge do gill GUIS ell casa Sigal Cus yi sie a Gell l CN gas y Gaya A dhe Di gas ve casus us Y gaa y A csi ali el uil
31. 0 VT100 and VT UTF8 Bits Per second Use this item to set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits 7 22 Chapter 7 BIOS is odd Select None if you do not want to send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is
32. 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 10 11 12 The options for Serial Port 2 are Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 10 11 12 7 21 SUPERSERVER 6028R TR TRT User s Manual Device Mode Use this feature to configure SUART clock source settings The options are 24MHz 13 and 24MHz Serial Port 2 Attribute Select SOL to use COM Port 2 as a Serial Over LAN SOL port for console redi rection The options are COM and SOL Serial Port Console Redirection COM 1 Console Redirection Console Redirection Select Enabled to enable COM Port 1 for Console Redirection which will allow a client machine to be connected to a host machine at a remote site for networking The options are Enabled and Disabled If the item above set to Enabled the following items will become available for configuration P Console Redirection Settings Terminal Type This feature allows the user to select the target terminal emulation type for Con sole Redirection Select VT100 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Char acter Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT10
33. 96 Bytes Maximum Read Request Select Auto for the system BIOS to automatically set the maximum size for a read request for a PCI E device to enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes ASPM Support Use this item to set the Active State Power Management ASPM level for a PCI E device Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration Select Disabled to disable ASPM support The options are Disabled Auto and Force LOs Warning Enabling ASPM support may cause some PCI E devices to fail MMIOHBase Use this item to select the base memory size according to memory address map ping for the IO hub The base memory size must be between 4032G to 4078G The options are 56T 48T 24T 512G and 256G MMIO High Size Use this item to select the high memory size according to memory address mapping for the IO hub The options are 256G 128G 512G and 1024G CPU1 Slot 1 PCI E x8 OPROM CPU1 Slot 2 PCI E x16 OPROM CPU1 Slot 3 PCI E x8 OPROM CPU2 Slot 4 PCI E x16 OPROM CPU2 Slot 5 PCI E x8 OPROM CPU2 Slot 6 PCI E x16 OPROM Select Enabled to enable Option ROM support to boot the computer using a de vice installed on the slot specified by the user The options are Disabled Legacy and EFI 7 20 Chapter 7 BIOS Onboard LAN Option ROM Type Select Enabled to enable Option ROM support to boot t
34. CU CPU1 Slot1 PCI Express 3 0 x8 Slot from CPU1 CPU1 Slot2 PCI Express 3 0 x16 Slot from CPU1 CPU Slot3 PCI Express 3 0 x8 Slot from CPU1 CPU2 Slot4 PCI Express 3 0 x16 Slot from CPU2 5 12 Chapter 5 Advanced Serverboard Setup CPU2 Slot5 PCI Express 3 0 x8 Slot from CPU2 CPU2 Slot6 PCI Express 3 0 x16 Slot from CPU2 T SGP101 2 3 Serial Link General Purpose I O Headers SP1 Internal Speaker Buzzer BP USB 0 1 Backpanel USB 2 0 Ports 0 1 BP USB 12 13 Backpanel USB 2 0 Ports 12 13 or USB 3 0 Ports 0 1 FP USB 2 3 4 5 Front Accessible USB 2 0 Connection Headers 2 3 4 5 FP USB TypeA Front Panel Accessible Type A Connector USB 3 0 Port 6 or USB 2 0 Port 10 J USB3 1 Front Panel Accessible USB 3 0 Ports 3 4 USB 2 0 8 9 LED Description State Status LE1 Rear UID LED Solid Blue Unit Identified LE2 Onboard PWR LED On System Power On LEDM1 BMC Heartbeat LED Blinking Green BMC Normal 5 13 SUPERSERVER 6028R TR TRT User s Manual 5 8 Connector Definitions ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition Power Connectors 13 33V 1 3 3V A 24 pin main power supply connector 14 ley S 3 3V J24 and two 8 pin power connectors 15 COM 3 COM JPWR1 JPWR2 are provided on the 16 PS ON 4 5V serverboard These power connectors 17 COM 5 COM meet the SSI EPS 12V specification 18 COM 6 5V These power connectors must be con 19 COM 7 COM nected to your power supply See the 20 R
35. D Active 5 15 Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table on the right for pin definitions Fan Headers There are eight fan headers on the serverboard Fan 1 Fan 6 Fan A Fan B all of which are 4 pin fans Pins 1 3 of the fan headers are backward compatible with the traditional 3 pin fans Fan speed control is supported with 4 pin fans only See the table on the right for pin definitions The fan speeds are controlled by Thermal Management via IPMI 2 0 interface Chassis Intrusion The Chassis Intrusion header is des ignated JL1 Attach an appropriate cable from the chassis to inform you SUPERSERVER 6028R TR TRT User s Manual Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 PWR LED Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 PWR Modulation Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion Input of a chassis intrusion when the chas 2 Ground sis is opened T SGPIO Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 Data T SGPIO1 2 T SGPIO S Headers 5 Load 6 Ground Three SGPIO Serial Link General 7 Clock 8 NC Purpose Input Output headers are located at T SGP101 2 3 to support the NC No Connection SATA ports See the table on the right I S6FIO0 3 4 8 amp S SATA 9 3 Suppor
36. E Port LOs Exit Latency Use this feature to set the length of time required for the port specified by the user to complete the transition from LOs to LO The default setting is 4uS 8uS PCI E Port L1 Exit Latency Use this feature to set the length of time required for the port specified by the user to complete the transition from L1 to LO The default setting is lt 1uS 1uS 2uS 2uS 4uS 4uS 8uS 8uS 16uS 16uS 32uS 32uS 64uS and gt 64uS Fatal Err Error Over Select Enable to force fatal error prorogation to the IIO core error logic for the port specified by the user The options are Disable and Enable Non Fatal Err Error Over Select Enable to force non fatal error prorogation to the IIO core error logic for the port specified by the user The options are Disable and Enable Corr Err Correctable Error Over Select Enable to force correctable error prorogation to the IIO core error logic for the port specified by the user The options are Disable and Enable LOs Support When this item is set to Disable 110 will not put its transmitter in the LOs state The default setting is Disable gt 1101 Configuration IOU2 IIO PCle Port 1 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4 x8 and Auto IOUO I10 PCle Port 2 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8
37. ID indicator provides aes Gin Uniten easy identification of a system unit that may be in need of service Note UID can also be triggered via IPMI on the motherboard For more information on IPMI please refer to the IPMI User s Guide posted on our website 5 9 Jumper Settings Explanation of Jumpers To modify the operation of the 3 serverboard jumpers can be used T T T to choose between optional settings Pins M Jumpers create shorts between two pins to change the function of the con nector Pin 1 is identified with a square solder pad on the printed circuit board See the serverboard layout pages for Jumper jumper locations Note On a two pin jumper Closed means the jumper is on both pins and Open means the jumper is either on only one pin or completely removed 5 20 CMOS Clear Chapter 5 Advanced Serverboard Setup JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power cord s 2 With the power disconnected short the CMOS pads with a metal object such as a small screwdriver 3 Remove the screwdriver or shorting device 4 Reconnect the power cord s and power on the system Note Do not use the PW ON connector to clear CMOS LAN1 LAN2 Enable Disab
38. IMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF 1 P2 DIMMG1 P2 DIMMH1 2 CPUs A CPU1 CPU2 8 16 DIMMs P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF 1 P2 DIMMG1 P2 DIMMH1 Any memory pairs in P1 P2 DIMM slots 2 CPUs amp CPU1 CPU2 16 DIMMs P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF1 P2 DIM MG1 P2 DIMMH1 P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 P2 DIMME2 P2 DIMMF2 P2 DIMMG2 P2 DIMMH2 Populating RDIMM ECC Memory Modules Intel E5 2600 V3 Series Processor RDIMM Memory Support Ranks DIMM Speed MT s Voltage V Slot per Channel SPC and DIMM Per Per Capacity GB Channel DPC DIMM amp Data 1 Slot Per Channel 2 Slots Per Channel Width 1DPC 1DPC 2DPC 4Gb 8Gb 1 2V 1 2V 1 2V SRx4 8GB 16GB 2133 2133 2133 DRx4 32GB 32GB 2133 2133 2133 16GB 5 9 SUPERSERVER 6028R TR TRT User s Manual 5 6 Adding PCI Add On Cards The 6028R TR TRT can accommodate six low profile PCI add on cards Installing an Add on Card 1 Begin by removing the shield for the PCI slot you wish to populate 2 Fully seat the card into the slot pushing down with your thumbs evenly on both sides of the card 3 Finish by using a screw to secure the top of the card shield to the chassis The PCI slot shields protect the serverboard and its components from EMI and aid in proper ventilation so make sure there is always a shield covering
39. IOS Recovery Enable JBR1 Close pins 1 and 2 of jumper JBR1 for BIOS recovery The default setting is on pins 2 and 3 for normal operation See the table on the right for jumper settings BMC Enable Jumper JPB1 allows you to enable the embedded Winbond BMC Base board Management Controller to provide IPMI 2 0 KVM support on the serverboard See the table on the right for jumper settings C Bus to PCI Exp Slots Jumpers JI C1 and JI C2 allow you to connect the System Management Bus 12C to the PCI Express slots The default setting is disabled Both jump ers must be set to the same setting See the table on the right for jumper settings 5 22 ME Mode Select Jumper Settings Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 Manufacture Mode BIOS Recovery Jumper Settings Both Jumpers Definition Pins 1 2 Enabled Pins 2 3 Normal BMC Enable Jumper Settings Jumper Setting Definition Pins 1 2 BMC Enabled Pins 2 3 Disabled PC to PCI E Slots Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled 5 10 Onboard Indicators LAN LEDs The Ethernet ports located beside the VGA port have two LEDs On each port one LED flashes to indicate activ ity while the other LED may be green amber or off to indicate the speed of the connection See the table on the right for the functions associated wit
40. KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST When this feature is set to Bootloader legacy Console Redirection is disabled before booting the OS When this feature is set to Always Enable legacy Console Redirection remains enabled upon OS boot The options are Always Enable and Bootloader Serial Port for Out of Band Management Windows Emergency Management Services EMS The submenu allows the user to configure Console Redirection settings to sup port Out of Band Serial Port management Console Redirection Select Enabled to use a COM port selected by the user for EMS Console Redi rection The options are Enabled and Disabled 7 25 SUPERSERVER 6028R TR TRT User s Manual If the item above set to Enabled the following items will become available for user s configuration Out of Band Management Port The feature selects a serial port in a client server to be used by the Windows Emergency Management Services EMS to communicate with a remote host server The options are COM1 Console Redirection and COM2 SOL Console Redirection Terminal Type Use this feature to select the target terminal emulation type for Console Redirec tion Select VT100 to use the ASCII character set Select VT100 to add color and function k
41. Please refer to our web site for a complete listing of supported processors www supermicro com Note that with only a single processor installed in the CPU1 socket PCI E slots 4 6 will not function Memory The X10DRi X10DRi T has sixteen DIMM slots that can support up to 1 TB of ECC registered unbuffered DDR4 2133 1866 1600 1333 memory Please refer to Chapter 5 for details on installing memory SATA A SATA controller is integrated into the chipset to provide a ten port SATA 3 0 subsystem which is RAID 0 1 10 and 5 capable Six ports are supported by the Intel PCH I SATAO 5 I SATA 4 and 5 are colored yellow to indicate that they have embedded power to support SATA DOMs and four are supported by the Intel SCU S SATAO 3 PCI Expansion Slots The X10DRi X10DRi T has three PCI E 3 0 x16 and three PCI E 3 0 x8 expansion slots Note that the PCI slots are controlled by the CPU so some slots may not be available when two CPUs are not installed on the board at the same time See the serverboard layout in Chapter 5 for details UO Ports The I O ports include one COM port a VGA monitor port four USB ports two Ethernet LAN ports 10 Gb ports on the X10DRi T and 1 Gb ports on the X10DRi and a dedicated IPMI LAN port 1 2 Chapter 1 Introduction Graphics Controller The X10DRi X10DRi T features an integrated Aspeed 2400 controller 1 3 Server Chassis Features The SC825TQ R740LPB is an ATX form factor chassis design
42. Port 80 connection 9 3 3V 10 LAD1 Use this header to enhance system 11 LADO 12 GND performance and data security See x 13 SMB CLK4 14 SMB_DAT4 the table on the right for pin definitions 15 3V DUAL 16 SERIRQ 17 GND 18 CLKRUN X 19 LPCPD 20 LDRQH X 5 17 SUPERSERVER 6028R TR TRT User s Manual Standby Power The Standby Power header is located at JSTBY1 on the serverboard See the table on the right for pin defini tions You must also have a cable to use this feature Power SMB PC Connector Power System Management Bus I C Connector JPI C1 monitors power supply fan and system temperatures See the table on the right for pin definitions IPMB A System Management Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB DC connection on your system Power LED Speaker Pins 1 3 of JD1 are used for power LED indication and pins 4 7 are for the speaker See the tables on the right for pin definitions Please note that the speaker connector pins 4 7 are used with an external speaker If you wish to use the onboard speaker you should close pins 6 7 with a cap 5 18 Standby Power Pin Definitions Pin Definition 1 5V Standby 2 Ground 3 Wake up PWR SMB Pin Definitions Pin Definition d Clock 2 Data 3 PWR Fail 4 Ground 5 3 3V IPMB Header Pin Definitions Pin
43. RMICRO 2 Microsoft Net Framework Optional Drivers amp Tools S E ASPEED Graphics Driver Intel C610 Chipset XIODRi T Intel Rapid Storage Technology Enterprise ug Y ma E EJ Intel USB 3 0 Drivers jm Ri B Intel PRO Network Connections Drivers Trusted Platform Module Driver Optional SUPERMICRO Computer Inc SUPERMICRO SuperDoctor 5 lt Build diver diskettes and manuals Eei E Browse CD Auto Start Up Nest Time For more information please visit SUPERMICRO s web site Figure 5 5 SuperDoctor Ill Interface Display Screen Health Information Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these items to install each item from top to the bottom one at a time After installing each item you must re boot the system before moving on to the next item on the list The bottom icon with a CD on it allows you to view the entire contents of the CD 5 25 SUPERSERVER 6028R TR TRT User s Manual SuperDoctor 5 The Supermicro SuperDoctor 5 is a program that functions in a command line or web based interface in Windows and Linux operating systems The program moni tors system health information such as CPU temperature system voltages system power consumption fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 come
44. SUPERO SUPERSERVER 6028R TR 6028R TRT UUUUUUUUUUUUUUU yy UUUUUUUUUUUUUUGU T U UUUTUU 222 o0d000000000000 600000000000000 gE EZ panana e oo 555656 d oo60000000000000 000000000000000 888000000000 PODO000000000000 660000000000600 ee ASSSAAABSAAAA q IQOOODOOOOOOOOO00 o o 2OOOOOOOOOOOO00 se OOOOOOOOOODOODO e XXDXDDODOOOOOO00 19 OOOOOOOOOOOOQOQOQ9 OCOOQOOOOOOOOOOQOO029 q i I n 2T LLL 1 jJ IINHEL L1 D T IOOOODOOOOOOOOOO so o QOOOOOOOOOQOQOO0 se DOOOOOOOOOCOOOOD o OOOODOOOOQOOOOO 20 9 COOOCGOOCOCOCOOOCOCOCO 9 OOOCOOOOOOOOOOOQOx0 I LI 1 l HI IL USER S MANUAL 1 0 The information in this User s Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com Super Micro Computer Inc Supermicro reserves the right to make changes to the product described in t
45. UID LED connections The red LED on pin 8 provides warnings of overheat fan failure or power failure The blue LED on pin 7 works as the front panel UID LED indicator Refer to the table on the right for pin definitions NIC2 LAN2 LED The LED connections for LAN2 are on pins 9 and 10 of JF1 Attach an LED cable to display network activity See the table on the right for pin definitions NIC1 LAN1 LED The LED connections for LAN1 are on pins 11 and 12 of JF1 Attach an LED cable to display network activity See the table on the right for pin definitions HDD LED The HDD LED connection is located on pins 13 and 14 of JF1 Attach a cable to Pin 14 to show HDD activity status Attach a cable to Pin 13 to use UID Switch See the table on the right for pin definitions Chapter 5 Advanced Serverboard Setup PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V Ground OH Fan Fail PWR Fail Blue_UID LED Pin Definitions JF1 Pin Definition 7 Blue_UID LED 8 OH Fan Fail Power Fail OH Fan Fail PWR Fail LED Status Red LED State Definition Off Normal On Overheat Flashing Fan Fail NIC2 LED Pin Definitions JF1 Pin Definition B Vcc 10 Ground NIC1 LED Pin Definitions JF1 Pin Definition 11 Vcc 12 Ground HDD LED Pin Definitions JF1 Pin Definition 13 UID Switch 14 H
46. Ue HEE ELA e ES BAER gt ARTE RATS RE Er Rer UT AE IR LEE Po TERA Ea ZT AE FRAY abe gt PATS ADT aE AE gt ERE ESR HERE AGA HAA ZS gt I EI SUPERSERVER 6028R TR TRT User s Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr Sie befinden sich in einer Situation die zu Verletzungen f hren kann Machen Sie sich vor der Arbeit mit Ger ten mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bersetzung in den bersetzten Sicherheitshinweisen die zusammen mit diesem Ger t ausgeliefert wurden BEWAHREN SIE DIESE HINWEISE GUT AUF INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este s mbolo de aviso indica peligro Existe riesgo para su integridad f sica Antes de manipular cualquier equipo considere los riesgos de la corriente el ctrica y familiaricese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el texto traducido en el apartado de traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES
47. Y BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly 5 27 SUPERSERVER 6028R TR TRT User s Manual Notes 5 28 Chapter 6 Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte nance on the SC825TQ R740LPB chassis For component installation follow the steps in the order given to eliminate the most common problems encountered If some steps are unnecessary skip ahead to the step that follows Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver 6 1 Static Sensitive Devices Electrostatic discharge ESD can damage electronic components To prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripher
48. aarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes HIT 35 0 OAR LCE PERO EU CE OI 35 OTRO EEN ab EL KREKED AUT AAS A FRI CAI HA A EL UREA O AA Bd ES SER Warnung Die Installation der Gerate muss den Sicherheitsstandards entsprechen jAdvertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Chapter 4 Warning Statements for AC Systems Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales zin YAWN pin oen gums JOP SINT Dapp YAWN pn noxii ng navn v5 npn daleiall Ail gll y ll al sill Jas of cas Aio w ll Glaeall Gus Y el je Sls KE 23449 2 sre 37 1491 44 9 E 44319 uu Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Product Disposal DM Warning Ultimate disposal of this product should be handled according to all national laws and regulations SO BERE TOBE BERL DAA ID BURT SAC OEE ENE LES E BEDS DUES zb E ot Ar snl Be FPS EE AEA ESAE ELE e Hig A es CT AE BS a EV RAS AAA T
49. al chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard Unpacking The serverboard is shipped in antistatic packaging to avoid static damage When unpacking the board make sure the person handling it is static protected 6 1 SUPERSERVER 6028R TR TRT User s Manual Figure 6 1 Front and Rear Chassis Views DVD ROM Drive optional USB Ports 2 COM Port Control Panel UUUUUUUUUUUUUUU f UUCUUUUGU UUU HAS Eesen 500 312480 GLEN 000000000000060 O00000000000000 ee ERRORS q 3 3 3 3 P q Cd I C ee HR I C i j IDE EI ES ES p s s i s i es X I I ji J 1 SATA Drives 8 System Reset Main Power Power Supplies Low profile PCI Slots
50. an damage electronic components To prevent dam age to any printed circuit boards PCBs it is important to handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard 5 1 SUPERSERVER 6028R TR TRT User s Manual Unpacking The serverboard is shipped in antistatic packaging to avoid electrical static dis charge When unpacking the board make sure the person handling it is static protected 5 2 Connecting Cables The cables listed below should already be connected to the serverboard These include the data cables for the peripherals and control panel and the power cables Connecting Data Cables Th
51. can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warn ing applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate WARNING Handling of lead solder materials used in this product may expose you to lead a chemical known to the State of California to cause birth defects and other repro ductive harm Manual Revision 1 0 Release Date August 7 2014 Unless you request and receive written permission from Super Micro Computer Inc you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2014 by Super Micro Computer Inc All rights reserved Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians It provides information for
52. cela hae UL j CSA GUSH aal ls dada y gild al gag AG yell s je I J ya Bacine Supermicro J ya Aia ill A e A AL w 8 sl el UL CSA Aale Jas A 78a AES AYE uou SAY pu ADA IEA debajo aco sie i ALBA BUCH HS CHE Alo BS oput e WH LE spe gale a USuc 47 2444 Electrical Appliance and Material Safety Law 2 4013949 AAA ASS Soe 2 He GS 7 44 8 ULEE CEA lat AGA AMECA Ho UL CSA7E EA E ARES emu ul de Waarschuwing Bij het installeren van het product gebruik de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen 4 19 SUPERSERVER 6028R TR TRT User s Manual Notes 4 20 Chapter 5 Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect the data and power cables and install add on cards All serverboard jumpers and connections are also described A layout and quick reference chart are included in this chapter for your reference Remember to completely close the chassis when you have finished working with the serverboard to better cool and protect the system 5 1 Handling the Serverboard Electrostatic Discharge ESD c
53. ces install the stabilizers before mounting or servicing the unit in the rack 2 3 SUPERSERVER 6028R TR TRT User s Manual 2 4 Installing the System into a Rack This section provides information on installing the SC825 chassis into a rack unit with the quick release rails provided There are a variety of rack units on the market which may mean the assembly procedure will differ slightly You should also refer to the installation instructions that came with the rack unit you are using Note This rail will fit a rack between 26 and 33 5 deep Separating the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself Installing the Inner Rail Extension The SC825 chassis includes a set of inner rails in two sections inner rails and inner rail extensions Inner rail extensions are attached to the inner rails to mount the chassis in the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated Repeat steps for the other
54. ded to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Allow any hot plug drives and power supply modules to cool before touching them Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling 2 2 Chapter 2 Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating tempera ture of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the ma
55. dule settings to enhance system data security Please reboot your system for any change on the TPM state to take effect The options are Disabled and Enabled Pending Operation Use this item to schedule a TPM related operation to be performed by a security device for system data integrity Your system will reboot to carry out a pending TPM operation The options are None Enable Take Ownership Disable Take Owner ship and TPM Clear Note Your system will reboot to carry out a pending TPM operation Current Status Information This item displays the status of the TPM support on this motherboard 7 27 SUPERSERVER 6028R TR TRT User s Manual ACPI Settings WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA plat form and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance System recovery and health monitoring The options are Enabled and Disabled High Precision Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing the de pendency on other timestamp calculation devices such as an x86 RDTSC Instruc tion embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer
56. e Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen SUPERSERVER 6028R TR TRT User s Manual jAdvertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis a des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent 55 pro rms msn PINT nma ARNT nvr 3 n AT 231 VW 530 pIo Agile dl ei gil ul jill are li y Ana Dele eat al la ye All yal aie AI e AS spud 3719 xp Wat B 1149 ue user sich Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen Hot Swap Fan Warning A Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Ze baak RAIVIO Zone EG H AE SD AUTRE IPAPER ELUTOAS REMO EK 3 TIO fii FIR 354 OBI OSC PEW EI EONAR SBR gt XU UT RE THE ERI IND ATERRIZAR Hm VK SEXES 4 16 Chapter 4 Warning Statements for AC Systems E de El i s CHER EHE HU BECK SER ilg gt gt elas aT RE UT CERES NOAA Be Ath E Warnun
57. e cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the flow of cooling air that moves through the system from front to back If you need to disconnect any of these cables you should take care to keep them routed as they were originally after reconnecting them make sure the red wires connect to the pin 1 locations The following data cables with their locations noted should be connected See the layout for connector locations e SATA S SATAO 3 I SATAO 5 drive cables e Control Panel cable JF1 Important Make sure the cables do not come into contact with the fans Connecting Power Cables The X10DRi X10DRi T has a 24 pin primary power supply connector J24 for con nection to the ATX power supply In addition there are two 8 pin 12V processor power connectors JPWR1 and JPWR2 that must be connected to your power supply See Section 5 9 for power connector pin definitions Connecting the Control Panel JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel buttons and LED indicators All JF1 wires have been bundled into a single cable to simplify this connection Make sure the red wire plugs into pin 1 as marked on the board The other end connects to the Control Panel PCB board located just behind the system status LEDs on the chassis See Chapter 5 for details and pin descriptions
58. each unused slot 5 10 Chapter 5 Advanced Serverboard Setup 5 7 Serverboard Details Figure 5 4 X10DRi X10DRi T Layout not drawn to scale z b O lo SI USI CUM ona mee SACS LN DEVON 820 pup TAN O 8X UE 19d LOS Lnd D m N 3009 OVW un tr 3 ax lt 20O 20 ES er 3009 uva E ee SE 33 E KE E E 9ooco D OO oO Krapp TETT 22 SS E 3 3 E 3 2s T SGP102 2222 5355 Bass ee S555 mmm 22222 eoooT SGPIO3 3555 s aa Na m e ZE EN ERA e p m el n RS E claas SZT a SS SE c Pala RIB B SE CES Battery 25m lao c edu 99 en co kk paraa RE Bee EIE cales ib Sie ol EEG KI E Clos eos i alls Intel P SEE 3 i j Sn SH le ES JBT1 spt E BREESE o E EE See 3 3 wer FEA H om o Es m m H E O Ze sE E eS lol Kach 6s Si E
59. ed to be used in a 2U rackmount configuration The following is a general outline of the main features of the SC825TQ R740LPB server chassis System Power The SC825TQ R740LPB features a redundant 740W power supply composed of two separate power modules This power redundancy feature allows you to replace a failed power supply module without shutting down the system Hard Drive Subsystem The SC825TQ R740LPB chassis was designed to support eight hot swap SATA hard drives Front Control Panel The control panel on the SC825TQ R740LPB provides you with system monitoring and control LEDs indicate system power HDD activity network activity system information and power supply failure A main power button and a system reset but ton are also included As an option two USB ports may be incorporated into the control panel to provide front side USB access Cooling Fans The SC825TQ R740LPB chassis has an innovative cooling design that includes three 8 cm hot plug system cooling fans located in the middle section of the chas sis The power supply module also includes a cooling fan 1 3 SUPERSERVER 6028R TR TRT User s Manual Figure 1 1 Chipset System Block Diagram Note This is a general block diagram Please see Chapter 5 for details 2 42 1 2 6
60. em boot The options are Legacy UEFI and Dual The default setting is Dual Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system to boot from Press lt Enter gt on each entry from top to bottom to select devices Dual Boot Order 1 Dual Boot Order 2 e Dual Boot Order 3 Dual Boot Order 4 Dual Boot Order 5 e Dual Boot Order 6 Dual Boot Order 7 e Dual Boot Order 8 Dual Boot Order 9 7 35 SUPERSERVER 6028R TR TRT User s Manual Dual Boot Order 10 Dual Boot Order 11 Dual Boot Order 12 Dual Boot Order 13 Dual Boot Order 14 Dual Boot Order 15 Add New Boot Option This feature allows the user to add a new boot option to system boot features Add Boot Option Use this item to specify the name of the driver that the new boot option is added to Path for Boot Option This item is used to specify the path to the driver that the new boot option is added to The format for the path is fsx path filename efi Boot Option File Path Create After the driver option name and the file path are set press Enter to enter to submenu and click OK to create the new boot option drive P Delete Boot Option Use this item to select a boot device to delete from the boot priority list Delete Boot Option Select the target boot device to delete P Delete Drive Option Use this item to select a driver to delete from the boot priority li
61. es NC 8 PWR OK table on the right for pin definitions 21 5V 9 5VSB 22 5v 10 12V 23 5V 11 12V 24 COM 12 3 3V Required Connection Secondary Power Connector 12V 8 pin Power JPWR1 and JPWR2 must also be delia connected to the power supply See the table on the right for pin defini tions Pins Definition 1 4 Ground 5 8 12V Required Connection Power Button The Power On connection is on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system Power Button Pin Definitions JF1 This button can also be configured to function as a suspend button with a Ping Definition setting in the BIOS To turn off the 1 Power Signal power when the system is in suspend 2 Ground mode press the button for 4 seconds or longer Refer to the table on the right for pin definitions Reset Button The Reset Button connection is Sino angen GFA located on pins 3 and 4 of JF1 and Pin Definition attaches to the reset switch on the 3 Reset computer chassis See the table on 4 Ground the right for pin definitions 5 14 Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1 Refer to the table on the right for pin defini tions Overheat OH Fan Fail PWR Fail UID LED Connect an LED cable to pins 7 and 8 of Front Control Panel to use the Overheat Fan Fail Power Fail and
62. et Throttling Mode Throttling improves reliability and reduces power consumption in the proces Sor via automatic voltage control during processor idle states The options are Disabled and CLTT Closed Loop Thermal Throttling Socket Interleave Below 4GB Select Enabled for the memory above the 4G Address space to be split between two sockets The options are Enable and Disable Channel Interleaving Use this item to set DIMM channel interleaving mood The options are Auto 1 Way Interleave 2 Way Interleave 3 Way Interleave and 4 Way Interleave 7 10 Chapter 7 BIOS Rank Interleaving Use this item to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way A7 Mode Select Enabled to support the A7 Addressing mode to improve memory per formance The options are Enable and Disable DIMM Information This item displays the status of a DIMM module specified by the user P1DIMMA1 P1DIMMB1 e P1DIMMC1 e P1DIMMD1 Memory RAS Reliability Availability Serviceability Configuration Use this submenu to configure the following Memory RAS settings RAS Mode When Disable is selected RAS is not supported When Mirror is selected the motherboard maintains two identical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel to boost performance The options are Disable Mirr
63. et hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden 4 11 SUPERSERVER 6028R TR TRT User s Manual Redundant Power Supplies A Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit JURE TODAY MEEBO EIR TD RES NCO SGADHVET A YbOBPMEWSEMITIS TN TORE MONEE IUEROECA V kr REES T DICERE m ERUIT Be IE IR RUE Rn i t Ee E V tz BEBE ITE nert LI gt AAA Ee LL EN E de Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant lectrique de l unit toutes les connexions d alimentation doivent tre d branch es IHN jbo n D p ax mmu TPN ni Dy ammonia 99 pg von v bp 20 308 mno 101 v mm STDP DN 4 12 Chapter 4 Warning Statements for AC Systems ASUS
64. etailed information on the X10DRi X10DRi T serverboard including the locations and functions of connections headers and jumpers Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC825TQ R740LPB server chas sis You should follow the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed informa tion on running the CMOS Setup Utility Appendix A BIOS Error Beep Codes Appendix B System Specifications Preface Notes SUPERSERVER 6028R TR TRT User s Manual Table of Contents Chapter 1 Introduction 1 1 SM M R P 1 1 1 2 Serverboard Features 1 2 Ile 1 2 M MO O de 1 2 SATA EE 1 2 PCIE XIAN SION SIONS EEN 1 2 VO POMS EC TC Graphics Controller 123 Server Chassis Features eie eq n reete da 1 3 cuum ee Segen ees Seegen Hard Drive Subsystem Front Control Panel otii reticere eater us rd ee dia elle de 1 4 Contacting Supermicro Chapter 2 Server Installation 2 1 eU 2 1 2 2 Unpacking the System
65. ey support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec tion Make sure that the same speed is used in both host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop data sending when the receiving buffer is full Send a Start signal to start data sending when the receiving buffer is empty The options are None Hardware RTS CTS and Software Xon Xoff The setting for each these features is displayed Data Bits Parity Stop Bits 7 26 Chapter 7 BIOS P Trusted Computing Available when a TPM device is installed and detected by the BIOS Configuration Security Device Support If this feature and the TPM jumper on the motherboard are both set to Enabled onboard security devices will be enabled for TPM support to enhance data integrity and network security Please reboot the system for a change on this setting to take effect The options are Enabled and Disabled TPM State Select Enabled to use TPM Trusted Platform Mo
66. g Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenstande von den ffnungen des L ftergeh uses entfernt jAdvertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du ch ssis Prenez garde ce que doigts tournevis et autres objets soient loign s du logement du bloc ventilateur mms V OTD PPT DWNT TIN NAA mao Pon NA 0507 UND man TANI Onn ONW may 937 MIVAENT NN moa prin pmn ell casa IS y a y yall AES A 5 Ae gai DY al of Sall Ye cl all Sis y TRAY As y pall AES A ls ll ye liso clad jo la pue y KEE Apre d zz di xus sue E EE EE IMA sl ges dall AAS Waarschuwing Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel uit het chassis Houd uw vingers schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing 4 17 SUPERSERVER 6028R TR TRT User s Manual Power Cable and AC Adapter A Warning When installing the product use the provided or designated connection cables power cables and AC adaptors Using any other cables and adaptors could cause a malf
67. g around the backplane Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes which aid in proper airflow Hard Drive Backplane The hard drives plug into a backplane that provides power drive ID and bus termi nation A RAID controller can be used with the backplane to provide data security The operating system you use must have RAID support to enable the hot swap capability of the hard drives The backplane is already preconfigured so no jumper or switch configurations are required DVD ROM Installation Optional The top cover of the chassis must be opened to gain full access to the DVD ROM drive bay The 6028R TR TRT accomodates only slim type DVD ROM drives Side mounting brackets are typically needed to mount a slim DVD ROM drive in the server Accessing the Inside of the Chassis 1 Grasp the two handles on either side and pull the unit straight out until it locks you will hear a click 2 Next depress the two buttons on the top of the chassis to release the top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server 6 6 Chapter 6 Advanced Chassis Setup 6 5 Power Supply The SuperServer 6028R TR TRT has a 740 watt redundant power supply consisting of two power modules Each power supply module has an auto switching capability which
68. g the bottom of the module to avoid installing incorrectly see Figure 5 3 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules Figure 5 3 DIMM Installation Release Tab Socket Key Release Tab 5 8 Chapter 5 Advanced Serverboard Setup Processor amp Memory Module Population Configuration For memory to work properly follow the tables below for memory installation Processors and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU1 P1 P1 P1 P1 P1 P1 P1 P1 DIMMA1 DIMMB1 DIMMC1 DIMMD1 DIMMA2 DIMMB2 DIMMC2 DIMMD2 CPU2 P2 P2 P2 P2 P2 P2 P2 P2 DIMME1 DIMMF1 DIMMG1 DIMMH1 DIMME2 DIMMF2 DIMMG2 DIMMH2 Processor and Memory Module Population for Optimal Performance Number of CPU and Memory Population Configuration Table CPUs DIMMs For memory to work properly please follow the instructions below 1CPU amp CPU1 2 DIMMs P1 DIMMA1 P1 DIMMB1 1CPU amp CPU1 4 DIMMs P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 1CPU amp CPU1 5 8 DIMMs P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 Any memory pairs in P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD 2 slots 2CPUs amp CPU1 CPU2 4 DIMMs P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMMF 1 2 CPUs A CPU1 CPU2 6 DIMMs P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF1 2 CPUs amp CPU1 CPU2 8 DIMMs P1 D
69. h the connection speed LED IPMI Dedicated LAN LEDs An additional Dedicated IPMI LAN is also located on the I O backplane The amber LED on the right indicates activity while the green LED on the left indicates the speed of the connec tion See the table at right for more information Onboard Power LED LE1 An Onboard Power LED is located at LE2 This LED Indicator is lit when the system is on Be sure to unplug the power cable before removing or adding any components See the table on the right for more details BMC Heartbeat LED A BMC Heartbeat LED is located at LEDM1 on the serverboard When D1 is blinking BMC is functioning normally 5 23 Chapter 5 Advanced Serverboard Setup LAE JLAN1 2 LED Connection Speed Indicator LED Color Definition Off 10 Mb s 100 Mb s or no connection Green 10 Gb s X10DRi T only Amber 1 Gb s IPMI LAN Activity LED Link LED E IPMI LAN Link LED Left amp Activity LED Right LED Status Definition Link Left Green Solid 100 Mb s Activity Right Amber Blinking Active Onboard PWR LED Indicator LED Settings LED Color Status Off System Off PWR cable not connected Green System On Green ACPI S1 State Flashing Quickly Green ACPI S3 STR State Flashing Slowly BMC Heartbeat LED Status Color State Definition Green Blinking BMC No
70. he top of the screen The Main BIOS setup screen is shown below System Date 7 2 Chapter 7 BIOS The following Main menu items will be displayed System Date System Time Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the lt Tab gt key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10DRi Version This item displays the version of the BIOS ROM used in the system Build Date This item displays the date when the version of the BIOS ROM used in the system was built Memory Information Total Memory This item displays the total size of memory available in the system Memory Speed This item displays the default speed of the memory modules installed in the system 7 3 SUPERSERVER 6028R TR TRT User s Manual 7 3 Advanced Setup Configurations Use the arrow keys to select Advanced setup and press Enter to access the submenu items CPU Configuration Warning Take Caution when changing the Advanced settings An incorrect value a very high DRAM frequency or an incorrect BIOS timing setting may cause the system to malfunction When this occurs restore the setting to the manufacture default setting gt Boot Feat
71. he computer using a device installed on the slot specified by the user The options are Legacy and EFI Onboard LAN1 Option ROM Onboard LAN2 Option ROM Use this option to select the type of device installed in LAN Port1 or LAN Port2 used for system boot The default setting for LAN1 Option ROM is PXE and the default setting for LAN2 Option ROM is Disabled VGA Priority Use this item to select the graphics device to be used as the primary video display for system boot The options are Onboard and Offboard Network Stack Select Enabled to enable PXE Preboot Execution Environment or UEFI Uni fied Extensible Firmware Interface for network stack support The options are Enabled and Disabled gt Super IO Configuration Super IO Chip AST2400 P Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 1 Serial Port 2 Select Enabled to enable the onboard serial port specified by the user The options are Enabled and Disabled Device Settings This item displays the base I O port address and the Interrupt Request address of a serial port specified by the user Change Port 1 Settings Change Port 2 Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 1 or Serial Port 2 Select Auto for the BIOS to automatically assign the base I O and IRQ address to a serial port specified The options for Serial Port 1 are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11
72. his LED will remain flashing or on as long as the indicated condition exists Information LED States State Indication Continuously On Red An overheat condition has occured Fast Blinking Red 1 Hz Fan Failure Slow Blinking Red 25 Hz Power Fail Solid Blue Local UID button has been activated Blinking Blue IPM Remote UID has been activated Note deactivating the UID LED must be performed in the same way it was activated If the UID LED was activated via IPMI you can only turn the LED off via IPMI and not with the UID button 3 2 Chapter 3 System Interface be NIC1 Indicates network activity on the LAN1 port when flashing f NIC2 Indicates network activity on the LAN2 port when flashing HDD This LED indicates hard drive and or DVD ROM drive activity when flashing a V Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating 3 4 Drive Carrier LEDs Each drive carrier has two LEDs Green When illuminated the green LED on the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Please refer to Chapter 6 for instructions on replacing failed SATA drives Red When this LED flashes it indicates the drive is rebuilding When solid on it indicates a SATA drive failu
73. his manual at any time and without notice This product including software and docu mentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ ment This equipment generates uses and
74. inner rail extension 2 4 Chapter 2 Server Installation Figure 2 1 Separating the Rack Rails e Rail Assembly Separating the Inner and Outer Rails 1 Locate the rail assembly in the chassis packaging Extending the Rails 2 Extend the rail assembly by pulling it Y SS outward N 3 Press the quick release tab Q Quick 4 Separate the inner rail extension from Release Tab the outer rail assembly Separating the Inner Rail Extension Warning do not pick up the server with the front handles They are de signed to pull the system from a rack only 2 5 SUPERSERVER 6028R TR TRT User s Manual A Figure 2 2 Assembling the Outer Rails Outer Rack Rails Outer rails attach to the rack and hold the chassis in place The outer rails for the SC825 chassis extend between 30 inches and 33 inches Installing the Outer Rails to the Rack 1 Secure the back end of the outer rail to the rack using the screws provided Press the button where the two outer rails are joined to retract the smaller outer rail Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack Repeat steps 1 3 for the remaining outer rail Stability hazard The rack stabilizing mechanism must be in place or the A rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to ti
75. ion for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the server was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install the system into the rack Follow the steps in the order given to complete the installation process in a minimum amount of time Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely 725 inches and approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing 2 1 SUPERSERVER 6028R TR TRT User s Manual This product is for installation only in a Restricted Access Location dedicated equipment rooms service closets and the like This product is not suitable for use with visual display work place devices acccording to 82 of the the German Ordinance for Work with Visual Display Units Warnings and Precautions Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully exten
76. isplay SSATA Port 0 Port 3 This item indicates that an sSATA port specified by the user is not installed or not detected Port 0 Port 3 sSATA Device Type Available when a SATA port is detected Use this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure sSATA as is set to RAID the following items will display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The options are Enabled and Disabled 7 17 SUPERSERVER 6028R TR TRT User s Manual SSATA RAID Option ROM UEFI Driver Select EFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot The options are Disabled EFI and Legacy SSATA Port 0 Port 3 This item displays the information detected on the installed sSATA drives on the particular sSATA port Model number of drive and capacity Software Preserve Support SSATA Port 0 Port 3 Select Enabled to enable an sSATA port specified by the user The options are Disabled and Enabled SSATA Port 0 Port 3 Hot Plug This feature designates this
77. le Device Tagging Select Enable to support device tagging The options are Disable and Enable gt South Bridge Configuration The following South Bridge information will display gt USB Configuration USB Configuration USB Module Version USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select Auto to disable legacy support if there are no legacy USB devices present Select Disable to have all USB devices available for EFI applications only The options are Enabled Disabled and Auto USB 3 0 Support Select Enabled for USB 3 0 support The options are Smart Auto Auto Enabled Disabled and Manual 7 12 Chapter 7 BIOS XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Ex tensible Host Controller Interface hand off The XHCI ownership change should be claimed by the XHCI driver The settings are Enabled and Disabled EHCI Hand Off This item is for operating systems that do not support Enhanced Host Controller Interface EHCI hand off When this item is enabled EHCI ownership change will be claimed by the EHCI driver The settings are Enabled and Disabled USB Mass Storage Driver Support Select Enabled for USB mass storage device support The options are Disabled and Enabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which in turn will provide complete legacy USB keyboard support for the
78. le Use JPL1 to enable disable the LAN ports 1 2 See the table on the right for jumper settings The default setting is Enabled Watch Dog Enable Disable Jumper JWD controls the Watch Dog function Watch Dog is a system moni tor that can reboot the system when a software application hangs Close pins 1 2 to to reset the system if an applica tion hangs Close pins 2 3 to generate a non maskable interrupt signal for the application that hangs See the table on the right for jumper settings Watch Dog must also be enabled in BIOS VGA Enable Disable JPG1 allows you to enable or disable the VGA port The default position is on pins 1 and 2 to enable VGA See the table on the right for jumper settings 5 21 LAN1 2 Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled default Pins 2 3 Disabled Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset default Pins 2 3 NMI Open Disabled VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled SUPERSERVER 6028R TR TRT User s Manual Manufacturer Mode Select Close pins 2 and 3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufac turer Mode which allows the user to flash the system firmware from a host server for system setting modifications See the table on the right for jumper settings B
79. min COM2 are located on the serverboard EE 7 Em COMI is located on the rear I O panel COM2 located next to PCI E Slot SIA is used to provide front access sup S SE S zu port See the table on the right for pin S S ia definitions paseo round WENA LAN Ports Ethernet Ports Pin Definitions Two Ethernet ports LAN1 2 are een located on the I O backplane These 1 PASO ES are 10 Gb ports on the 6028R TRT P 1 pare and 1 Gb ports on the 6028R TR In JD i rSUSSE addition a dedicated IPMI LAN port TDi 13 a e Yel located above the USB 0 1 ports on 5 aay m Em the backplane All these ports accept Yellow 3V3SB RJ45 type cables 6 TD2 15 Ground Note Please refer to the LED Indicator 7 THE i listo Section for LAN LED information 8 Us iid Ground 9 TD3 18 Ground 5 19 SUPERSERVER 6028R TR TRT User s Manual Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and an LED indicator are provided on the motherboard The rear UID switch is UID Switch located next to the VGA port on the Enc backplane The front UID switech is 7 EXE located on pin 13 of the JF1 header 3 rm The rear UID LED LE1 is located g Button next to the UID switch and the front UID LED is located on pin 7 on JF1 4_ Ground When you press the UID switch the UID LED UID LED will be turned on Press the Status UID switch again to turn off the LED Coloris Status indicator The U
80. mponents 1 Unplug the power cord from the power supply 1 Unscrew and remove the heatsink screws in the sequence shown in the picture below 2 Hold the heatsink and gently wiggle it to loosen it from the CPU Do not use excessive force when doing this 3 Once the heatsink is loosened remove it from the CPU 4 Clean the surface of the CPU and the heatsink to get rid of the old thermal grease Reapply the proper amount of thermal grease before you re install the heatsink 5 7 SUPERSERVER 6028R TR TRT User s Manual 5 5 Installing Memory Warning Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Memory Support The X10DRi X10DRi T supports up to 1 TB of DDR4 2133 1866 1600 1333 RDIMM ECC memory or 2 TB of LRDIMMs Use memory modules of the same type and speed See the following tables for memory installation Please refer to the Supermicro web site for possible updates to supported memory DIMM Installation Installing Memory Modules 1 Insert the desired number of DIMMs into the memory slots starting with DIMM P1 DIMMA1 When populating two DIMM modules within a channel always start with Bank1 first For optimal memory performance please install a pair or pairs of memory modules of the same type and speed with a maximum of 12 modules see the Memory Installation Table below 2 Insert each DIMM module vertically into its slot Pay attention to the notch alon
81. ncludes USB or PS 2 Con Out devices keyboard PCI or Serial Console Redirection IPMI KVM or SOL Con Out includes Video Con troller PCI or Serial Console Redirection IPMI SOL 1 beep per device Refresh 1 beep or each USB device detected IPMI Error Codes 1 Continuous Beep System OH System Overheat A 1 SUPERSERVER 6028R TR TRT User s Manual Notes Appendix B System Specifications Appendix B System Specifications Processors Single or dual Intel amp E5 2600 Series V3 Socket R3 processors in LGA 2011 Sockets both CPUs must be of the same type Note All PCI E slots will not be enabled when using only a single processor See the motherboard layout on page 5 11 for details Please refer to our web site for a complete listing of supported processors Chipset Intel C612 chipset BIOS 16 MB AMI SPI Flash ROM Memory Capacity Sixteen DIMM slots supporting up to 1 TB of ECC registered unbuffered DDR4 2133 1866 1600 1333 memory Note See Section 5 5 for details SATA Controller Intel chipset based SATA controller for 10 SATA 3 0 ports Expansion Slots Three PCI E 3 0 x16 and three PCI E 3 0 x8 expansion slots Drive Bays Eight hot swap drive bays to house eight 3 5 SATA drives Serverboard X10DRi X10DRi T Dimensions 12 1 x 13 05 in 307 x 331 mm B 1 SUPERSERVER 6028R TR TRT User s Manual Chassis SC825TQ R740LPB 2U rackmount Dimensions WxHxD 16 8 x 3 5 x 25 5 in
82. nd Disabled If the item above set to Enabled the following items will become available for user s configuration P SOL COM2 Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type Use this feature to select the target terminal emulation type for Console Redirec tion Select VT100 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to se
83. nd a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 7 24 Chapter 7 BIOS Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start data sending when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Dis abled and Enabled Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects Function Keys and
84. ng the setup navigation process These keys include F1 F4 Enter lt Esc gt arrow keys etc Note Options printed in Bold are default settings How To Change the Configuration Data The configuration data that determines the system parameters may be changed by entering the AMI BIOS setup utility This setup utility can be accessed by pressing Del at the appropriate time during system boot 7 1 SUPERSERVER 6028R TR TRT User s Manual How to Start the Setup Utility Normally the only visible Power On Self Test POST routine is the memory test As the memory is being tested press the Delete key to enter the main menu of the AMI BIOS setup utility From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your system has a BlOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special incidental or consequential dam ages arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boot failure 7 2 Main Setup When you first enter the AMI BIOS setup utility you will enter the Main setup screen You can always return to the Main setup screen by selecting the Main tab on t
85. nufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connec tions other than the direct connections to the branch circuit i e the use of power strips etc Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack f the rack is provided with stabilizing devi
86. number is separated by dots and it should not exceed 255 Station MAC Address This item displays the Station MAC address for this computer Mac addresses are 6 two digit hexadecimal numbers 7 32 Chapter 7 BIOS Gateway IP Address This item displays the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Router MAC Address This item displays the Router MAC address for this computer 7 33 SUPERSERVER 6028R TR TRT User s Manual 7 6 Security Settings This menu allows the user to configure the following security settings for the system Administrator Administrator Password Use this feature to set the administrator password which is required before entering the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 char acters long Password Check Select Setup for the system to prompt for a password at Setup Select Always for the system to prompt for a password at bootup and upon entering the BIOS Setup utility The options are Setup and Always 7 34 Chapter 7 BIOS 7 7 Boot Settings Use this feature to configure Boot Settings DUAL Boot Mode Select Use this item to select the type of device to be used for syst
87. o set this feature select Save as User Defaults from the Exit menu and press En ter gt This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press En ter Use this feature to retrieve user defined settings that were saved previously Boot Override This feature allows the user to override the Boot priorities sequence in the Boot menu and immediately boot the system with another device specified by the user This is a one time override 7 38 Appendix A BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST Power On Self Test routines which are performed at each System boot errors may occur Non fatal errors are those which in most cases allow the system to continue to boot The error messages normally appear on the screen Fatal errors will not allow the system to continue with bootup procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor responding error Motherboard BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Ready to boot 5 short beeps 1 long beep Memory error No memory detected in the system 5 beeps No Con In or No Con In i
88. on Make sure that the CPU is properly inserted into the socket before closing the load plate If it doesn t close properly do not force it as it may damage your CPU Instead open the load plate again and double check that the CPU is aligned properly 7 With the CPU in the socket in spect the four corners of the CPU Gently close the load plate to make sure that they are flush h with the socket Close the load plate Lock the lever labeled Close 1st then lock the lever labeled Open 1st Use your thumb to gently push the load levers down until the lever e locks Push down and lock the level labeled Close 1st Push down and lock the lever labeled Open ist 5 6 Chapter 5 Advanced Serverboard Setup Installing a CPU Heatsink 1 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism 2 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws which may damage the CPU 3 Finish the installation by fully tightening all four screws NO 1 SCREW 0 4 SCREW NO 3 SCREW 0 2 SCREW Removing the Heatsink Warning We do not recommend removing the CPU or the heatsink If you do need to remove the heatsink please follow the instructions below to prevent damage to the CPU or other co
89. ons are Disable and Enable Link L1 Enable Select Enable to enable Link L1 Level 1 link The options are Disable and Enable Isoc Mode Select Enabled to enable Isochronous support to meet QoS Quality of Service requirements This feature is especially important for Virtualization Technology The options are Enable and Disable 7 9 SUPERSERVER 6028R TR TRT User s Manual gt Memory Configuration Enforce POR Select Enable to enforce POR restrictions on DDR4 frequency and voltage pro gramming The options are Auto Enforce POR Disabled and Enforce Stretch Goals Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules The options are Auto 1333 1400 1600 1800 1867 2000 2133 2200 2400 2600 2667 and Reserved Do not select Reserved ECC Support Select Enable to enable Error Checking amp Correction ECC support for onboard memory modules The options are Auto Enable and Disable Data Scrambling Select Enabled to enable data scrambling to enhance system performance and data integrity The options are Auto Disabled and Enabled Enable ADR Select Enabled for ADR Automatic Diagnostic Repository support to enhance memory performance The options are Enabled and Disabled DRAM RAPL Running Average Power Limit Baseline Use this feature to set the run time power limit baseline for DRAM modules The options are Disable DRAM RAPL Mode 0 and DRAM RAPL Mode 1 S
90. or and Lockstep Mode Lockstep x4 DIMMs Select Enable to enable Lockstep support for x4 DIMM modules The options are Auto Disabled and Enabled Memory Rank Sparing Select Enable to enable memory sparing support for memory ranks to improve memory performance The options are Disabled and Enabled Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor the original source When this item is set to Enabled the IO hub will read and 7 11 SUPERSERVER 6028R TR TRT User s Manual write back one cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Enable and Disable Patrol Scrub Interval This feature allows you to decide how many hours the system should wait be fore the next complete patrol scrub is performed Use the keyboard to enter a value from 0 24 Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error is corrected and sent to the requestor the original Source Memory is updated as well Select Enable to use Demand Scrubbing for ECC memory correction The options are Enable and Disab
91. ort Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The options are Enabled and Disabled SSATA Port 0 Port 3 This item displays the information detected on the installed on the sSATA port specified by the user Model number of drive and capacity 7 16 Chapter 7 BIOS Software Preserve Support SSATA Port 0 Port 3 Select Enabled to enable an sSATA port specified by the user The options are Disabled and Enabled SSATA Port 0 Port 3 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to replace a sSATA disk drive installed on this port without shutting down the system The options are Enabled and Disabled sSATA Port 0 Port 3 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to start a COMRE SET initialization to the device The options are Enabled and Disabled Port 0 Port 3 sSATA Device Type Use this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure sSATA as is set to IDE the following items will d
92. othing and Erase Immediately Note After making changes on a setting be sure to reboot the system for the changes to take effect Log EFI Status Codes Select EFI Extensible Firmware Interface Status Codes to log EFI status codes Select Error Codes to log EFI error codes Select Progress Code to log the EFI progress code Select both to log both EFI error codes and progress codes The options are Disabled Both Error code and Progress code Note After making changes on a setting be sure to reboot the system for the changes to take effect BMC Network Configuration The following items will be displayed LAN Channel 1 Configuration Address Source Use this item to select the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dy namic Host Configuration Protocol server attached to the network and request the next available IP address for this computer The options are DHCP Unspecified and Static Current Configuration Address Source This item displays the current configuration address source Station IP Address This item displays the Station IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Subnet Mask This item displays the sub network that this computer belongs to The value of each three digit
93. p over 2 6 Chapter 2 Server Installation S LLL 3 A PEE PEE E E TEE E Figure 2 3 Installing the Rack Rails Note this figure is for illustrative purposes only Always install servers to the bot tom of a rack first Installing the Chassis into a Rack 1 Extend the outer rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used to secure the to hold the front of the chassis to the rack Note that the figure above is for illustration purposes only Always install servers to the bottom of the rack first A Slide rail mounted equipment is not to be used as a shelf or a work space 2 7 SUPERSERVER 6028R TR TRT User s Manual Notes Chapter 3 System Interface Chapter 3 System Interface 3 1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system and the activ ity and health of specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off button RESET Reset Use the reset button to
94. ply with Local and National Electrical Codes seseeeeeeeeeeereeeeee 4 14 leie gl Eet 4 15 Hot Swap Fari Watrrlhg orien i eroi ia ra ita ir eee 4 16 Power Cable and AC Adapter soe tre tbt cR be rH EROR d 4 18 Chapter 5 Advanced Serverboard Setup 5 1 Handling the ServerbOard t tpe i deni leases 5 1 PRECAUTIONS e 5 1 WM PACKING EE 5 2 5 2 Connecting Cables eic iex on REPRE nausea E ERR dU IE dud 5 2 Connecting Data Cables ro te tipp te etre ree engan 5 2 Connecting Power Cables sss nennen nennen 5 2 Connecting the Control Panel voor ise 5 2 Melo ME 5 3 5 4 Installing the Processor and Heatsink nessieira 5 4 listalling anEGA2011 Process EE 5 4 Installing a CPU Heatsink ege iioii eae eite de ctc rehenes 5 7 Removing the HeatsilK or cada 5 7 5 o Installirig Memofy itinere etm eet Pee ire care bte ee reote ed 5 8 Memory SUP DOM scar EE 5 8 DIMM Installati ni i orent ica Crate et erae nre rre 5 8 Processor amp Memory Module Population Configuration 5 9 5 6 Adding PCI Add On GC rds cente He He refe eig 5 10 b Sermenboard DetallS uso creer eor tancia Onda 5 11 X10DRi X10DRi T Quick Reierence siiirisririisissiserisesiesiisdrerin nira 5 12 vii SUPERSERVER 6028R TR TRT User s Manual 5 8 Connector Definitioris soon een n ren recs 5 14 5 9 Jumper Settings creep coerente ta 5 20 5 10 Onboard Miete ee 5 23
95. prise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro Web site at http www supermicro com products nfo files storage SAS 1 Com pList 110909 pdf 6 4 Chapter 6 Advanced Chassis Setup SATA Drive Installation These drives are mounted in carriers to simplify their installation and removal from the chassis The carriers also help promote proper airflow for the drives For this reason even empty carriers without hard drives installed must remain in the chassis Removing a Drive Carrier 1 Push the release button located beside the drive s LEDs 2 Swing the handle fully out and use it to pull the drive carrier straight out see Figure 6 3 Mounting a Drive in a Drive Carrier 1 To add a new SATA drive install the drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier 2 Secure the drive to the carrier with four screws as shown in Figure 6 4 Note Your operating system must have RAID support to enable the hot plug ca pability of the drives Figure 6 3 Removing a Drive Carrier Release Button 6 5 SUPERSERVER 6028R TR TRT User s Manual Figure 6 4 Mounting a Drive in a Carrier e Caution Regardless of how many hard drives are installed all drive carriers must remain in the drive bays to maintain proper airflow Use caution when workin
96. processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to the Supermicro web site for updates on CPU support Installing an LGA2011 Processor Press down on the lever labeled Close 1st There are two levers on the LGA2011 socket First press and release the load lever labeled Open 1st Press the second load lever labeled Close 1st to release the load plate from its locked position Pull lever away from the socket 5 4 Chapter 5 Advanced Serverboard Setup 3 With the lever labeled Close 1st fully retracted gently push down on the Open ist lever to open the load plate Lift the load plate to open it completely a Gently push down to pop the load plate open 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned carefully lower the CPU straight down into the socket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically and do not rub the CPU against any pins of the socket which may damage the CPU or the socket 5 5 SUPERSERVER 6028R TR TRT User s Manual Warning You can only install the CPU to the socket in one directi
97. re If a drive fails you should be notified by your System management software Please refer to Chapter 6 for instructions on replacing failed drives 3 3 SUPERSERVER 6028R TR TRT User s Manual Notes Chapter 4 Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements The following statements are industry standard warnings provided to warn the user of situations which have the potential for bodily injury Should you have questions or experience difficulty contact Supermicro s Technical Support department for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety information cfm Warning Definition A Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents we oy sie a WET v Af PVE RELET ARCOD RIED BO 370 C d TUO MER C GB E llc SACA EEE C BREN EDS RIOT FEU TS ARE gt T 1EJA T BY RE E ER D SEES PE FERC UE 5 LE Z BE IMITAN SUUS E AER ELEY HIE ES A FEY FHA E TX BUI
98. re is set to Enable the EV DFX Lock Bits that are located on a processor will always remain clear during electric tuning The options are Dis able and Enable kO Configuration 10U2 IIO PCle Port 1 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4 x8 and Auto IOUO 00 PCle Port 2 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto 10U1 IIO PCle Port 3 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto No PCle Port Active ECO Use this feature to select a workaround setting to implement the engineering change order ECO on the system when the PCI ports specified by the user are not active The options are PCU Squelch exit ignore option and Reset the SQ FLOP by CSR option P Socket 0 PCIeDOOFO Port 0 DMI Link Speed This item configures the link speed of a PCI E port specified by the user The options are Gen 1 Generation 1 2 5 GT s and Gen 2 Generation 2 PCI E Port DeEmphasis This item configures the De Emphasis Control LANKCON2 6 setting for this computer The options are 6 0 dB and 3 5 dB 7 6 Chapter 7 BIOS The following items will be display PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI
99. reboot the system Power This is the main power button which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplied to the system 3 1 SUPERSERVER 6028R TR TRT User s Manual 3 3 Control Panel LEDs The control panel located on the front of the chassis has several LEDs These LEDs provide you with critical information related to different parts of the system This section explains what each LED indicates when illuminated and any corrective action you may need to take 20 s Power Fail Indicates a power supply module has failed The second power supply module will take the load and keep the system running but the failed module will need to be replaced Refer to Chapter 6 for details on replacing the power supply This LED should be off when the system is operating normally O 7 Information LED This LED will be solid blue when the UID function has been activated When this LED flashes red it indicates a fan failure When red continuously it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are installed properly see Chapter 5 T
100. rmal 5 11 SATA Ports SATA 3 0 Ports There are ten Serial ATA Ports which include six SATA supported by the PCH C612 I SATAO 5 and four SATA supportd by the Intel SCU S SATAO 3 See the table on the right for pin definitions The 6028R TR TRT supports a total of eight 3 5 hot swap hard drives SUPERSERVER 6028R TR TRT User s Manual SATA Port Pin Definitions Pin Definition Pin Definition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground 5 24 Chapter 5 Advanced Serverboard Setup 5 12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp ftp supermicro com Some of these must be installed such as the chipset driver After accessing the ftp site go into the CDR Images directory and locate the ISO file for your motherboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown in Figure 5 5 should appear SUPERMICRO X1ODRi T Motherboard Drivers amp Tools Win7 X Intel Chipset INF files Y al SUPE
101. ro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma gsupermicro nl Customer Support Web Site www supermicro nl Asia Pacific Address Super Micro Computer Inc SF No 150 Jian ist Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3992 Email support supermicro com tw Web Site www supermicro com tw 1 5 SUPERSERVER 6028R TR TRT User s Manual Notes Chapter 2 Server Installation Chapter 2 Server Installation 2 1 Overview This chapter provides a quick setup checklist to get your SuperServer 6028R TR TRT up and running Following these steps in the order given should enable you to have the system operational within a minimum amount of time This quick setup assumes that your system has come to you with the processors and memory prein stalled If your system is not already fully integrated with a serverboard processors System memory etc please turn to the chapter or section noted in each step for details on installing specific components 2 2 Unpacking the System You should inspect the box the 6028R TR TRT was shipped in and note if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable locat
102. s in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Man agement Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SD5 Manage ment Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Note The default User Name and Password for SuperDoctor 5 is admin admin Figure 5 6 SuperDoctor 5 Interface Display Screen Health Information SuperDoctor 5 Select Language English El admin Health Info SS Motherboard ED TU LNA 9 Status A E Fan Speed 1 126 126 126 w D 5 a D ao 80 Laos D E 20 je E Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms sd5 cfm 5 26 Chapter 5 Advanced Serverboard Setup 5 13 Onboard Battery Please handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Figure 5 7 Installing the Onboard Battery LITHIUM BATTER
103. se this item to configure the PCI latency timer for a device installed on a PCI bus Select 32 to set the PCI latency timer to 32 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 PCI Bus Clocks VGA Palette Snoop Select Enabled to support VGA palette register snooping which will allow a PCI card that does not contain its own VGA color palette to examine a video card pal ette and mimic it for proper color display The options are Disabled and Enabled PERR Generation Select Enabled to allow a PCI device to generate a PERR PCI PCI E Parity Error number for a PCI bus error event The options are Enabled and Disabled SERR Generation Select Enabled to allow a PCI device to generate an SERR System Error number for a PCI bus error event The options are Enabled and Disabled 7 19 SUPERSERVER 6028R TR TRT User s Manual Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address The options are Enabled and Disabled SR IOV Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are Enabled and Disabled Maximum Payload Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 40
104. st Delete Driver Option Select the target driver to delete gt Hard Disk Driver BBS Priorities This item sets the boot sequence of available hard disk drives 7 36 Chapter 7 BIOS 7 8 Save amp Exit Select the Save amp Exit tab from the BIOS setup screen to configure the settings below Restore Defaults Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press lt Enter gt Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion parameters can take effect Select Save Changes and Exit from the Exit menu and press lt Enter gt Save Options Save Changes When you have completed the system configuration changes select this option to save all changes made This will not reset reboot the system Discard Changes Select this option and press lt Enter gt to discard all the changes and return to the AMI BIOS Utility Program 7 37 SUPERSERVER 6028R TR TRT User s Manual Restore Defaults To set this feature select Restore Defaults from the Exit menu and press Enter These are manufacture default settings designed for maximum system performance but not for maximum stability Save As User Defaults T
105. standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES 4 3 SUPERSERVER 6028R TR TRT User s Manual Installation Instructions A Warning Read the installation instructions before connecting the system to the power source eue TS VAT LATIN CAS SHC RPMS wie FEO THEE Za ERE LIA HC BTA gt Hi A ES CT kt ACA EE NERO GTC ea AA o Warnung Vor dem AnschlieRen des Systems an die Stromquelle die Installationsanweisungen lesen jAdvertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation nna pn nayan mmn 7159 nona nmm nx RP v AGUA jaa col pil do gi Ud cas jill cul il x NAGS Ado Ads Ao 24 ez erred filo Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit 4 4 Chapter 4 Warning Statements for AC Systems Circuit Breaker A Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 250 V 20 A poy hI COD LS RARE QI EURO LETTS o EM CO RE HTL UC ed PRETO ENGAN250 V 20 AZERA CE Ze life FEO Ir Ej CHE UTC RAP LY Ut PRU S RA PRP
106. t for pin definitions T SGPIO I SATA Ports Supported T SGPIO1 I SATA Ports 0 1 2 3 Supported T SGPIO2 I SATA Ports 4 5 Supported T SGPIO3 S SATA Ports 0 1 2 3 Supported 5 16 Chapter 5 Advanced Serverboard Setup Internal Buzzer SP1 Pin Definition Internal Speaker Pin Definitions Pin 1 Pos Beep In The Internal Speaker located at SP1 can be used to provide audible indica ei MSBP SC tions for various beep codes See the m table on the right for pin definitions BEP IN Zoe ALARM SP NEG Overheat LED Pin Definitions Overheat Fan Fail LED Pins Definition The JOH1 header may be connected i BS to an LED indicator to provide warn e ings of chassis overheating or fan mE um LED atus failure Refer to the table on right for pin definitions State Message Solid Overheat Blinking Fan Fail DOM Power Connectors DOM PWR Pin Definitions Two power connectors for DOM Disk On Module devices are located at JSD1 JSD2 Connect appropriate cables here to provide power support for your Serial Link DOM devices Pin Definition 1 5V 2 Ground 3 Ground TPM Port 80 Header Pin Definitions Pin Definition Pin Definition TPM Header Port 80 Header 1 LCLK 2 GND A Trusted Platform Module Port 80 io A a header is located at JTPM1 to provide x SESE IMOS e 7 LAD 3 8 LAD 2 TPM support and
107. tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enable and Disable Interrupt Remapping Select Enable for Interrupt Remapping support to enhance system performance The options are Enable and Disable Coherency Support Non Isoch Select Enable for the Non Iscoh VT d engine to pass through DMA Direct Memory Access to enhance system performance The options are Enable and Disable 7 8 Chapter 7 BIOS Coherency Support Isoch Select Enable for the Iscoh VT d engine to pass through ATS to enhance system performance The options are Enable and Disable gt QPI Quick Path Interconnect Configuration The following QPI information will be displayed Number of CPU Number of IIO Current QPI Link Speed This item displays the current QPI Link speed Current QPI Link Frequency This item displays the frequency of the QPI Link QPI Global MMIO Low Base Limit QPI Global MMIO High Base Limit e QPI PCI E Configuration Base Siz Size Link Speed Mode Use this feature to select data transfer speed for QPI Link connections The op tions are Fast and Slow Link Frequency Select Use this feature to select the desired QPI frequency The options are 6 4 GT s 8 0 GT s 9 6 GT s Auto and Auto Limited Link LOp Enable Select Enable to enable Link LOp The opti
108. the installation and use of the SuperServer 6028R TR TRT Installation and maintainance should be performed by experienced technicians only The SuperServer 6028R TR TRT is a high end server based on the SC825TQ R740LPB 2U rackmountable chassis and the X10DRi X10DRi T dual processor serverboard Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the serv er system and describes the main features of the X10DRi X10DRi T serverboard and the SC825TQ R740LPB chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6028R TR TRT into a rack and check out the server configuration prior to powering up the System If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer here for details on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system Chapter 4 Standardized Warning Statements You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6028R TR TRT SUPERSERVER 6028R TR TRT User s Manual Chapter 5 Advanced Serverboard Setup Chapter 5 provides d
109. the top chassis cover while the system is still running to determine which of the fans has failed Replacing System Fans Removing a Fan 1 Remove the chassis cover 2 Press the tabs on the sides of the fan to unlock and remove the fan and its housing The fan s power connections will automatically detach 3 System power does not need to be shut down since the fans are hot plug gable Installing a New Fan 1 Replace the failed fan with an identical 8 cm 12 volt fan available from Supermicro 2 Position the new fan into the space vacated by the failed fan previously re moved A click can be heard when the fan is fully installed in place and the power connections are made 3 If the system power is on the hot plug feature will cause the fan to start im mediately upon being connected to its header on the serverboard 6 3 SUPERSERVER 6028R TR TRT User s Manual Figure 6 2 Removing System Cooling Fans 6 4 Drive Bay Installation Removal Accessing the Drive Bays You do not need to access the inside of the chassis or remove power to replace or swap SATA drives Proceed to the next step for instructions You must use standard 1 high SATA drives in the system DVD ROM For installing removing the DVD ROM drive you will need to gain ac cess to the inside of the server by removing the top cover of the chassis Proceed to the DVD ROM Installation section later in this chapter for instructions Note Enter
110. tions are Hard Disk Drive and Solid State Drive If the item above Configure SATA as is set to IDE the following items will display Serial ATA Port 0 Port 5 This item indicates that a SATA port specified by the user is not installed or not present Port 0 Port 5 SATA Device Type Available when a SATA port is detected Use this item to specify if the SATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure SATA as is set to RAID the following items will display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The options are Enabled and Disabled SATA RAID Option ROM UEFI Driver Select EFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot The options are Disabled EFI and Legacy Serial ATA Port 0 Port 5 This item displays the information detected on the installed SATA drives on the particular SATA port Model number of drive and capacity Software Preserve Support Port 0 Port 5 Select Enabled to enable a SATA port specified by the user The options are Disabled and Enabled
111. unction or a fire Electrical Appliance and Material Safety Law prohibits the use of UL or CSA certified cables that have UL CSA shown on the code for any other electrical devices than products designated by Supermicro only WPI KRLACT RFA BUNS SAA BEER Pe SHE SET 7 V EI REACT NI BLA PEW LOT T IPT 27 SALH TSOP Old SC tin DES SEUB Mea ULE Ze IRAN D7 7 JW UL CSEv 775 a Rica nt Supermicro fH FS ADU MEETS STL SL TOES SERIE nalts AAS pe DE RENE BA ca EA TA Pac as REO REIKO gt ERY Supermi c roffa EAI am BSH All TEE ELIE TS IE BE FHZRZEULERCSATA TEMA gt CRA E Se RUL CSARFS e Ee zi H Bie Ae E SEAS IL GEAR as HE DI D EA GH EA ERE E M s ROSSI BE ers HEERKE gt ER T Supe rmi cropa EHA m BIA moe PEA E EE ARE UL OSA Jon gt SUN Leger CAE be DL Hr EF D BS i Y Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen elektrischen Ger te als Produkte
112. ure Quiet Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM display setting Select Force BIOS to use the Option ROM display mode set by the system BIOS The options are Force BIOS and Keep Current Bootup Num Lock Use this feature to set the Power on state for the Numlock key The options are Off and On Chapter 7 BIOS Wait For F1 If Error Select Enabled to force the system to wait until the F1 key is pressed if an error occurs The options are Disabled and Enabled Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Immediate the ROM BIOS of the host adaptors will capture Inter rupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Postponed the ROM BIOS of the host adaptors will not capture Interrupt 19 immediately and allow the drives attached to these adaptors to function as bootable devices at bootup The options are Immediate and Postponed Re try Boot When EFI Boot is selected the system BIOS will automatically
113. ve Runtime Error Logging Support is set to Enable Select Enabled for the BIOS to correct a memory error if it is correctable The op tions are Enabled and Disabled PCI Ex PCI Express Error Enable Select Enabled for the BIOS to correct errors occurred in the PCI E slots The op tions are Enabled and Disabled 7 29 SUPERSERVER 6028R TR TRT User s Manual Memory Correctable Error Threshold Use this item to enter the threshold value for correctable memory errors The default setting is 10 Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are No and Yes When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full Select Do Nothing for the system to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used to determine how long in minutes should the multiple event counter wait before generating a new event log Enter a number between 0 to 99
Download Pdf Manuals