1. Repair and Return Warranty FCC Class B Looking for New Ideas Contact Ugron GETTING STARTED Key Definitions Operation Keys ON CLEAR On Clear Turns power on Press once to clear the display This will not clear the last rolled measurement as it is a permanent value and can be recalled to the main display at any time by pressing RCL RCL SET ON CLEAR Off Turns power off Turning power off clears the display and semi permanent values length width count All permanent values and settings such as modes scales and units remain intact Holding down the ON CLEAR key for 2 seconds also powers the unit off ON CLEAR MODE Clear All Clears all values including memory Resets all permanent settings except Preferences SET ON CLEAR to turn the device off then MODE ON CLEAR Software Reset Clears all values including memory Resets all permanent settings including Preferences 1 Scale Master Pro RESET Hardware Reset If your Scale Master Pro should ever lock up use a paperclip or similar size object to press the RESET hole Clears all values including memory All permanent settings including Preferences remain intact SET Set Key Used with other keys to access second functions and place the Scale Master Pro into programming mode If in programming mode already pressing SET will store the displayed value and exit programming mo
2. 885 4949 E mail techsup calculated com lal World Wide Web www calculated com 31 Scale Master Pro CALCULATED Jj 71 7 INDUSTRIES Software copyrighted and licensed to Calculated Industries by Scale Master Technologies LLC 2009 User s Guide copyrighted by Calculated Industries 2009 Scale Master and Calculated Industries are registered trademarks of Calculated Industries Inc ALL RIGHTS RESERVED CALCULATED INDUSTRIES 4840 Hytech Drive Carson City NV 89706 U S A 1 800 854 8075 or 1 775 885 4900 Fax 1 775 885 4949 E mail info calculated com www calculated com Designed in the U S A Printed in China 10 08 XK ee UG6025E A
3. Holding SUB and repeated presses of SCALE will scroll backward through the available scales 3 Scale Master Pro UNITS Unit Selection Repeated presses of UNITS will scroll through the available units of measurement See Imperial Units and Metric Units sections SUB UNITS Scroll Back Units Holding SUB and repeated presses of UNITS will scroll backward through the available units SET MODE Preferences Accesses the preference settings See Preferences section lt LxW Left Arrow Moves to the left when setting values for custom scales and height Will scroll back through available settings within the preferences gt M Right Arrow Moves to the right when setting values for custom scales and height Will scroll forward through available settings within the preferences Y RCL Down Arrow Decreases the number when setting values for custom scales and height Will scroll down through the preferences A COUNT Up Arrow Increases the number when setting values for custom scales and height Will scroll up through the preferences User s Guide 4 Measuring Keys LxW Length Width Area Enters the displayed measurement as length Once a length is entered enters a second measurement as width and displays the total area Repeated presses will scroll through the following results 1 Area 2 Volume if Height is entered 3 Store
4. conserve battery power the unit will shut itself off if it is not used for 4 6 minutes Press the ON CLEAR key to restore power All registers and settings remain intact including all temporary registers Battery Replacement To replace the batteries 1 To remove battery door release snap lock in N slot and lift 2 Remove batteries and replace with new batteries 4 positive side up 3 To replace the door slide it at an angle and x push down 25 Scale Master Pro Default Settings The following are the factory defaults of the Scale Master Pro Default Default Settings Imperial Metric Mode ARCH ARCH Scale 1 4 1 50 Custom Scales gl 1 1 Linear FT IN MM Area SQ FT SQ M Volume CUYD CUM Length 0 0 0 00 Width 0 0 0 00 Height 0 0 0 00 Count 0 0 Subtract Mode Off Off Preferences Default Button Beep On Rolling Click On Stored Value Display Clear LCD User s Guide 26 Specifications Power Source Two 3 Volt CR 2032 lithium batteries Approximately 400 hours normal use Display Method LCD with commas annunciators and zero suppression Display Capacity Main Display 9 999 999 7 digits Resolution Accuracy 025 Inch 99 75 Note Based on start stop point and scale magnitude users typically experience 2 3 rolling error Dimensions 7 2 x 1 8 x 0 4 182mm x 45mm x 10mm 27 Scale Master Pro Repair and Return Warranty Repair
5. and Return Information Return Guidelines 1 Please read the Warranty in this User s Guide to determine if your Calculated ndustries product remains under warranty before calling or returning any device for evaluation or repairs f your product won t turn on check the atteries as outlined in the User s Guide f you need more assistance please go to our website listed below f you believe you need to return your product please call a Calculated ndustries representative between the hours of 7 00am to 4 30pm Pacific Time for additional information and a Return Merchandise Authorization RMA Call Toll Free 1 800 854 8075 Outside USA 1 775 885 4900 www calculated com warranty User s Guide 28 Warranty Warranty Repair Service USA Calculated Industries CI warrants this product against defects in materials and workmanship for a period of one ar from the date of original consumer purchase in the Ifa defect e during the warranty period CI at its etion will either repair using new or remanufactured parts or replace with a new or remanufactured unit the product at no charge THE WARRANTY WILL NOT APPLY TO THE PRODUCT IF IT HAS BEEN DAMAGED BY MISUSE ALTERATION ACCIDENT IMPROPER HANDLING OR OPERATION OR IF UNAUTHORIZED REPAIRS ARE ATTEMPTED OR MADE SOME EXAMPLES OF DAMAGES NOT COVERED BY WARRANTY INCLUDE BUT ARE NOT LIMITED TO BATTERY LEAKAGE BENDING A BLACK INKSPOT OR VIS
6. entries in Memory ON CLEAR M Clears the Memory register User s Guide 16 Programming Mode The Scale Master Pro allows you to pre set frequently used values including e Custom Scales 3 Imp 3 Met e Height value To begin setting values press the SET key and then the desired key to be programmed The following keys are used in programming mode UNITS Toggles through available units M gt Advances the cursor to the next place to the right LxW Moves the cursor back to the next place to the left COUNT A Increases the selected value RCL V Decreases the selected value ON CLEAR Exits without saving any changes SET Exits and saves changes 17 Scale Master Pro Setting Custom Scales You can store six Custom Scales three in Imperial Mode and three in Metric Mode You can set a custom scale two ways by rolling in a known distance or by entering the exact distance Rolling a Custom Scale 1 Press MODE until OPEN being a number 1 3 appears in the scale box display 2 Press SET SCALE ROLL will appear in the main display 3 Roll desired distance ROLLING now appears in the main display 4 Press SCALE The annunciator will begin flashing FT IN for Imperial Mode M for Metric Mode 5 To change the units of measurement press UNITS until your desired units appear Press the M gt or th
7. to move forward or the LxW key to move backward through the settings for the selected preference Once the desired setting is displayed press the COUNT A or RCL V key to move to another preference or press SET to save and exit 9 Scale Master Pro Imperial Metric Modes The Scale Master Pro is set up to use Imperial Standard dimensional units by default The Scale Master Pro can be set to Metric Mode by switching the IMP MET switch to MET While in Metric mode MET will remain lit in the display Built In Scales Imperial Standard Units Architect Engineer Engineer Il ARCH ENGI ENGII 1 foot 1 inch 1 inch 1 4 10 0 300 0 3 8 20 0 333 3 1 2 30 0 400 0 3 4 40 0 416 6 1 1 1 50 0 500 0 3 2 1 2 60 0 583 3 2 1 2 83 3 600 0 3 1 3 100 0 625 0 4 1 4 166 6 666 6 1 32 200 0 750 0 1 16 250 0 1 000 0 3 32 1 200 0 1 8 2 000 0 3 16 3 000 0 User s Guide 10 Metric Units Architect Engineer l Engineer Il ARCH ENGI ENGII 1 50 1 100 0 1 1 000 1 75 1 125 0 1 1 250 1 1 1 150 0 1 1 500 1 2 1 200 0 1 1 625 1 3 1 250 0 1 2 000 1 4 1 300 0 1 2 500 1 5 1 400 0 1 5 000 1 10 1 500 0 1 6 000 1 20 1 10k 1 25 1 12 5k 1 30 1 20k 1 40 1 25k 1 50k Changing Modes Repeated presses of the MODE key will scroll through the list of available modes Holding SUB when pres
8. IBLE CRACKING OF THE LCD WHICH ARE PRESUMED TO BE DAMAGES RESULTING FROM MISUSE OR ABUSE To obtain warranty service in the U S please go to the website A repaired or replacement product assumes the remaining warranty of the original product or 90 days whichever is longer Non warranty Repair Service USA Non warranty repair covers service beyond the warranty period or service requested due to damage resulting from misuse or abuse Contact Calculated Industries at the number listed above to obtain current product repair information and charges Repairs are guaranteed for 90 days Repair Service Outside the USA To obtain warranty or non warranty repair service for goods purchased outside the U S contact the dealer through which you initially purchased the product If you cannot reasonably have the product repaired in your area you may contact CI to obtain current product repair information and charges including freight and duties 29 Scale Master Pro Disclaimer CIMAKES NO WARRANTY OR REPRESENTATION EITHER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCT S QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AS A RESULT THIS PRODUCT INCLUDING BUT NOT LIMITED TO KEYSTROKE PROCEDURES MATHEMATICAL ACCURACY AND PREPROGRAMMED MATERIAL IS SOLD AS IS AND YOU THE PURCHASER ASSUME THE ENTIRE RISK AS TO ITS QUALITY AND PERFORMANCE IN NO EVENT WILL CI BE LIAB
9. LE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM NY DEFECT IN THE PRODUCT OR ITS DOCUMENTATION The warranty disclaimer and remedies set forth above are exclusive and replace all others oral or written expressed or implied No CI dealer agent or employee is authorized to make any modification extension or addition to this warranty Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may also have other rights which y from state to state FCC Class B va This equipment has been tested and found to comply with the limits for a Class B calculating device pursuant to Part 15 of the FCC Rules Looking for New Ideas Calculated Industries a leading manufacturer of special function calculators and digital measuring instruments is ys interested in new product ideas in these areas If you have a new product idea please visit our Bright Idea page at www calculated com brightidea asp For suggestions about improving this product or other products please visit us at www calculated com under Contact Us Thank You alwa User s Guide 30 Contact Us Mail Calculated Industries Inc 4840 Hytech Drive Carson City NV 89706 U S A Cm Phone 775 885 4900 Fax 775
10. MASTER PRO Rotate to Adjust Wheel Adjusting the Wheel The Celcon polymer wheel can be adjusted for each user s preference To adjust the wheel take a small flat head jeweler s screwdriver and slightly rotate the screw located near the wheel tip Rotating the screw about 1 4 to 1 3 turn should be sufficient Rotating the screw within those two values should adjust the wheel between free spinning which is too loose to skidding which is too tight 7 Scale Master Pro Preferences Preferences allow customization of how the Scale Master Pro functions during certain operations The following preferences are available Button Beep butn Toggles on or off the beep sound that occurs at the press of a button or during auto count Beep On Button beep on Beep Off Button beep off Rolling Click roll Toggles on or off the clicking sound that occurs while rolling Clic On Rolling click on Clic Off Rolling click off Stored Value Display Stor Toggles whether the value remains displayed or is cleared after being stored Clr Led Display cleared No Cir Display not cleared User s Guide 8 Setting Preferences 1 2 3 4 Press SET MODE to access the preferences Press the COUNT A key to move up or the RCL V key to move down through the list of preferences When the preference to be changed is displayed press the M gt key
11. ScaLE MASTER Pro ADVANCED DIGITAL PLAN MEASURE Model 6025 User s Guide Weer EE Ido INDUSTRIES FAST ACCURATE RELIABLE Scale MASTER Pro Introduction The Scale Master Pro Multi Scale Digital Plan Measure has been specifically designed to simplify takeoffs from architectural and engineering drawings Finds linear measurements of any shape Finds rectangular areas and volumes Converts between scales and dimensions Built in push button counter e Subtract function Six Custom Scales that let you define and roll in any scale TABLE OF CONTENTS Getting Started Key Definitions Setup Keys Measuring Keys Function Keys Using the Scale Master Pro Adjusting the Wheel Preferences Imperial Metric Modes Built In Scales Imperial Standard U Metric Units Changing Modes Changing Scales Changing Units Locking Modes Scales and Units Operation cece Rolling a Measurement Using the Memory Function Additional Memory Functions Programming Mode Setting Custom Scales Rolling a Custom Scale Entering a Custom Scale Setting a Height Finding Area and Volume Finding Area Finding Volume Additional Area Volume Functions Appendix Error Auto Range Function Interference Battery Automatic Shut Off Battery Replacement Default Settings Specifications
12. d Height if Height is entered 4 Stored length 5 Stored width RCL LxW Length Width Recall Displays the length value Additional presses of LxW will display the width area and volume values On a clear display LxW can be pressed without RCL ON CLEAR LxW Length Width Clear Clears the length and width SET LxW H Height Set Enters the height setting mode See the Setting a Height section RCL SET LxW Height Recall Displays the stored height value 5 Scale Master Pro Function Keys M Memory Plus Adds the displayed value to the accumulative value RCL M Memory Recall Displays the value stored in accumulative memoty ON CLEAR M Memory Clear Clears the accumulative memory value SET M M Memory Minus Subtracts the displayed value from the accumulative memory SUB M will perform the same function COUNT Count Increases the count value by one y SUB COUNT Count Subtract Decreases the count value by one RCL COUNT Count Recall Displays the count value in the main display ON CLEAR COUNT Count Clear Clears the count value SUB Subtract Mode Toggles subtract mode on and off When subtract mode is on rolling forward or backward will subtract from the displayed measurement Press SUB a second time or press ON CLEAR to turn subtract mode off User s Guide 6 USING THE SCALE
13. de A press of SET after rolling locks the measurement While locked the displayed value will not be affected by rolling the Scale Master Pro A second press of SET will unlock the measurement RCL Recall Key Used to recall stored values When you press RCL RCL the last value rolled is displayed allowing roll to continue from this value Recalling any other value disables measuring until the recalled value is cleared with a press of ON CLEAR IMP MET Imperial Metric Switch Toggles between Imperial and Metric modes User s Guide 2 LOCK Lock Switch The Lock Switch is located on the side of the unit When the lock is activated a lock symbol will be displayed in the LCD While active you cannot alter Scales Modes Units Preferences or the IMP MET Imperial Mettic switch You also cannot perform a Cleat All or a Software Reset It is advised to use the Scale Master Pro in the locked position unless you ate specifically setting or changing a setting Setup Keys MODE Mode Selection Repeated presses of MODE will scroll through the available modes See Changing Modes section SUB MODE Scroll Back Modes Holding SUB and repeated presses of MODE will scroll backward through the available modes SCALE Scale Selection Repeated presses of SCALE will scroll through the available scales See Changing Scales section SUB SCALE Scroll Back Scales
14. e LxW key to begin setting the distance The selected digit will start flashing cont d User s Guide 18 contd 6 Press COUNT A to increase or RCL V to decrease the selected digit Press the M P key to move to the next digit to the right or the LxW key to move back to the left Once the desired value has been entered press SET to store value and exit the programming mode Note Pressing ON CLEAR will exit the programming mode without saving any value as the Custom Scale Entering a Custom Scale 1 2 Press MODE until OPEN being a number 1 3 appears in the scale box display Press SET SCALE ROLL will appear in the main display Press SCALE again The annunciator will begin flashing FT IN for Imperial Mode The left most digit flashes for Metric Mode Note If in Metric Mode skip to Step 5 19 Scale Master Pro To change the units of measurement press UNITS until your desired units appear Press the M gt or the LxW key to begin setting the distance The selected digit will start flashing In Imperial mode the scale will be one inch equals the distance you entered In Metric mode entered scales are direct ratios Press COUNT A to increase or RCL V to decrease the selected digit Press the M gt key to move to the next digit to the right or the LxW key to move back to the left Onc
15. e the desired value has been entered press SET to store value and exit the programming mode Press RCL SCALE while in custom mode to display the current custom scale User s Guide 20 Setting a Height The height function is used to enter a height value for finding volume To set a height 1 Press SET LxW to access the height function The appropriate annunciator will begin flashing FT IN for Imperial mode or M for Metric mode An H will appear in the display To change the units of measurement press UNITS until your desired units appear Press the M gt or the LxW key to begin setting the distance The selected digit will start flashing Press COUNT A to increase or RCL WV to decrease the selected digit Press the M P key to move to the next digit to the right or the LxW key to move back to the left Once the desired value has been entered press the SET key to save and exit 21 Scale Master Pro Finding Area and Volume The Scale Master Pro can calculate Area and Volume once you have your values set for Length Width and for Volume Height Finding Area 1 Roll the first side and press the LxW key to store as Length 2 Roll the second side and press LxW to store as Width The main display will show the calculated Area Finding Volume To access Volume after you have your values set for Length Width and Height
16. repeatedly press the LxW key The following results will display 1 Stored Length 2 Stored Width 3 Area 4 Volume 5 Height Volume and Height do not display if a Height has not been set 22 User s Guide Additional Area Volume Functions RCL LxW Displays the value stored in the Length register Repeated presses of the LxW key will toggle through additional outputs including Width Area and if Height is stored Height and Volume ON CLEAR LxW Clears the values stored as Length and Width 23 Scale Master Pro APPENDIX Error Auto Range Function Error Message If you make an incorrect entry such as trying to add dimensioned and non dimensioned values together the Scale Master Pro will display the word ERROR Press ON CLEAR to cleat Auto Range Function If the value is too large to display in the selected units of measurement the answer will be displayed in the next larger measurement units instead of showing an error for example 10 000 000 MM cannot be displayed so 10 000 M will be displayed instead Interference Exposure to direct light or close proximity to cell phones and other electronic devices may cause interference with the Scale Master Pro device and result in erroneous measurements User s Guide 24 Battery Automatic Shut Off The Scale Master Pro is powered by two 3 Volt CR 2032 Lithium batteries 6 volts total To
17. sing MODE will scroll backward through the list of available modes 11 Scale Master Pro Changing Scales Repeated presses of the SCALE key will scroll through the list of available scales Holding SUB when pressing SCALE will scroll backward through the list of available scales Changing Units Repeated presses of the UNITS key will scroll through the list of available units Holding SUB when pressing UNITS will scroll backward through the list of available units Locking Modes Scales and Units Your Scale Master Pro comes equipped with a lock switch that prevents inadvertently changing drawing scales When the lock is activated a lock symbol will be displayed in the LCD While active the Mode Scale and Units cannot be revised User s Guide 12 Operation Do not rotate W Try to ke p the unit in the same upright position while you roll Rotating the unit while rolling will add or subtract distance Begin and end measurements from this point 13 Scale Master Pro Rolling a Measurement To take a measurement with the Sca e Master Pro 1 Turn the unit on If the display does not show zero 0 press the ON CLEAR key to clear the display 2 Select your type of scale by pressing the MODE key Then press the SCALE key to select your scale 3 Begin rolling The display will register your measutements When you roll the unit be sure to hold
18. the unit upright see the first picture in the Operation section Also make sure you start and stop at the exact points you are measuring Otherwise your roll may not be accurate see the second picture in the Operation section 4 Press the ON CLEAR key to clear the display and begin a new measurement User s Guide 14 Using the Memory Function The Memory function allows you to add rolled or counted values However you cannot add dimensioned rolled and non dimensioned counted values together To add rolled values 1 Roll the first value Press M The Memory indicator M appears and the value is added to Memory 2 Roll the next value Press M This value is added to your previous value stored in Memory 3 You can continue to add values using the M key Press RCL M to review the total in Memory Note For count values you must press the COUNT key to count your value Then press RCL COUNT 0 move the count value to the main display Press M to add this value to Memory See the Function Keys section for additional memory functions 15 Scale Master Pro Additional Memory Functions SET M Subtracts the value in the main display from the value stored in Memory RCL M Displays the total accumulated value in Memory Repeated presses of M will toggle between total accumulated value number of entries in Memory and average value of all