Home
Chief PDC2000B flat panel ceiling mount
Contents
1. Q A padlock or bolt may placed through latch holes Figure 3 WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT Ensure mounting buttons are completely engaged in mounting holes NOTE Holes are provided in the faceplate for use with a padlock or similar locking device if desired In addition the pin and nut may be removed from the upper holes and moved to the lower holes for use as a more permanent locking device See Figure 3 Connect and secure power audio and video cables Removing Displays from PDC 1 Disconnect all power audio video cables 2 Remove bolt or padlock from faceplate if used See Figure 4 NOTE The pin may have been used as a more permanent locking device If so remove nut and pin and move from the lower holes to the upper holes 3 Pull back on flags on upper mounting holes and press pins down into Open position See Figure 4 Remove bolt or padlock if used Pins in Closed position move to Open position to remove display Pins in Open position move to Closed position after display is removed 4 5 Figure 4 WARNING EACH DISPLAY MAY WEIGH IN EXCESS OF 40 LBS EACH Always use two people and proper lifting techniques when installing or positioning displays on PDC Carefully lift displays from PDC Lift up on pins and place flags back a
2. Bevestiging losdraaien Desserrez les fixations N Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Installation Instructions PDC Series TOOLS REQUIRED FOR INSTALLATION e 9 16 5 32 included B 1 5 32 C 1 5 16 18 x 3 8 Installation Instructions PDC Series INSTALLATION WARNING FAILURE TO PROVIDE ADEQUATE STRUCTURAL STRENGTH FOR THIS COMPONENT CAN RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component Attaching PDC to Extension Column CAUTION Watch for pinch points Do not place fingers between movable parts IMPORTANT These installation instructions assume that a 1 1 2 NPT or NPSM Schedule 40 0 154 minimum thickness steel or aluminum ASTM B221 extension column not included has been properly installed and is in place 1 Thread the PCD mount A onto the existing 1 1 2 NPT or NPSM extension column not included until tight with a minimum
3. INSTALLATION INSTRUCTIONS Large Dual Ceiling Mount CHIEF PDC Series Our Mounts Your Vision PDC Series Installation Instructions DISCLAIMER Milestone AV Technologies Inc and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document A IMPORTANT SAFETY INSTRUCTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components
4. are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located between the supporting structure and the PDC does not exceed 400 Ibs 181 44 kg 200 lbs 90 72 kg each faceplate The weight capacity of the PDC may be LIMITED to the lowest weight capacity of any other component located between the PDC and the supporting structure WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING Never operate this mounting system if it is damaged Return the mounting system to a service center for examination and repair WARNING Do not use this product outdoors IMPORTANT The PDC Series mounts are designed to be mounted to a 1 1 2 or NPSM following ANSI ASME B1 20 1 Schedule 40 0 154 minimum thickness steel or aluminum ASTM B221 threaded extension colum
5. gainst faceplate to return it to Closed position See Figure 4 Installation Instructions PDC Series Adjustments Roll Adjustment 1 Loosen two Nylock nuts inside the PDC See Figure 5 2 Using the slotted holes adjust the roll or horizontal movement 3 Tighten two Nylock nuts x2 SS Display and faceplate removed for clarity Figure 5 Pitch Adjustment 4 Loosen two screws on side of PDC See Figure 5 5 Adjust to desired pitch or vertical movement 6 Tighten the screws on side of PDC PDC Series Installation Instructions USA International CHIEF Our Mounts Your Vision Europe Chief a products division of Milestone AV Technologies Asia Pacific 8800 002607 Rev00 2014 Milestone AV Technologies www chiefmfg com 05 14 gt 6436 City West Parkway Eden Prairie MN 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580 845 Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477
6. n not included NOTE The PDC Series includes e Accessory Model PDC2000 to be used with two Listed Chief accessory PSBU interface brackets not included SAVE THESE INSTRUCTIONS Installation Instructions PDC Series DIMENSIONS 0 TE PSBU INTERFACE BRAC KETS NOTSHOWN THE PSBU INTERFACE BRACKET WILL ADD 1 IN DEPTH AND MAY AFFECTTHE LOCATIO N OF THE DISPLAY ON THE MOUNT TOP MOUNTING BUTTON ON PSBU GOES HERE 1627 413 Ki E 78 a 1 1 2 NPSM 17 20 mtu X Y e US a 16 28 FACE TILTS UP 5 414 178 DOWN 25 BOTH SIDES L 3 23 i ox J S 82 5 PATENT 4905101 e 4 06 But Youd L WE 103 APPROXIMATE C ENTER OF DISPLAY 11 42 DIMENSIONS INGHES 290 MILLIMETERS LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio
7. of four threads engaged See Figure 1 Figure 1 2 Install and tighten the 5 16 18 x 3 8 set screw C See Figure Attaching Interface Bracket to Displays 1 Attach PSBU interface brackets to displays following instructions included with interface brackets Installing Displays on PDC WARNING EXCEEDING MAXIMUM WEIGHT CAPACITY CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installers responsibility to ensure the total amount of weight placed on the mount does not exceed 400 Ibs 181 44 kg 200 165 90 72 kg each faceplate WARNING DISPLAY MAY WEIGH IN EXCESS OF 40 LBS 18 14 KG Always use two people and proper lifting techniques when installing or positioning display Mounting button Ww 9 ASKS Display Figure 2 1 While supporting each side of display align four mounting buttons on interface bracket with four mounting holes on PDC See Figure 2 and See Figure 3 PDC Series Installation Instructions 2 Lower each display into place listening for audible click to ensure recessed area of mounting buttons are properly seated in lower area of mounting holes See Figure 2 and See Figure 3 May remove 4 move to lower holes
Download Pdf Manuals
Related Search
Related Contents
talento 371/372 pro talento 751/752 pro Gräs slin Gm bH Consignes 4PAK-D Operating Manual Samsung SGH-C120 Instrukcja obsługi Manuale di Installazione, Funzionamento e Manutenzione per le Rheem Uncased_N_Coil - Gas & Oil Furnace Specification Sheet DEPARTAMENTO PASTORAL COLEGIO SAN NICOLAS DE MYRA GCP 10000 CR POWER Outdoor Unit - daikin tech.co. uk Copyright © All rights reserved.
Failed to retrieve file