Home

StarTech.com 2 Port Switched IP PDU - Single-Phase Remotely Managed IP Power Switch

image

Contents

1. gt Once the reboot is complete click the OK button StarTechy om 22 Hard to find made easy Instruction Manual Specifications 1 IEC 60320 C14 Power 1 IEC 60320 C14 Power Plug Plug 1 DB 9 9 pin D Sub Male Connectors 1 RJ 45 Female 2 RJ 45 Female 2 NEMA 5 15 Power North 2 NEMA 5 15 Power North America Receptacle America Receptacle Max Current load per Port uA Max Total Current Output Hen Power Consumption 4 5 W Enclosure Material Steel anke 0 C to 40 C 32 F to 104 F emperature storage 0 C to 70 C 32 F to 158 F emperature Humidity 0 85 RH Non Condensing Dimensions 182 x 125 x 44 mm Weight 780g 820g Cc P rr Instruction Manual ota rlechg dud 23 Hard to find made easy Technical Support StarTech com s lifetime technical support is an integral part of our commitment to provide industry leading solutions If you ever need help with your product visit www startech com support and access our comprehensive selection of online tools documentation and downloads For the latest drivers software please visit www startech com downloads Warranty Information This product is backed by a two year warranty In addition StarTech com warrants its products against defects in materials and workmanship for the periods noted following the initial date of purchase During this period the products may be returned for repair or replacement with equivalent products at our
2. modify the power state of each outlet individually or make global changes to both From the Monitor tab you can also Schedule events and configure the Auto Ping feature Monitor System Firewall Account TimeSync Event Upgrade Logout istOutet 2nd Outlet A Configuration B Schedule fe Network Start Shutdown Description Delay Time Delay Time a T eee Save Configuration Tab Click on the Set button located on the top corner of each outlet to modify an individual outlet When the Set button is orange the outlet is ready to be configured Description Allows you to give each outlet a more meaningful name if desired Start Delay Time Each outlet can be programmed to startup at different time intervals instead of both of them starting up at the same time Shutdown Delay Time Each outlet can be programmed to shutdown at different time intervals instead of shutting both of them down at the same time Save Saves all changes StarTechy om 7 Hard to find made easy Instruction Manual Schedule Tab Configure scheduled actions for each outlet Click on the Set button located on the top corner of each outlet to modify an individual outlet When the Set button is orange the outlet is ready to be configured IMConfig ration G2 Schedule feNelwork Recurrence Action SE E CNN HEELS a a ee Daily vV 10 v s9 v On v ADD Recurrence An Action can be scheduled to occur yearly
3. UE 2 Roser BUTON Me 2 lrtisll de e 3 Hardware Installati n anco bt tense ee ete ner rr BERUF p PERDU EDD DO RUD 3 Logging In for the First Time suus oves oriri n br d RARE ERE Ebr sienna re e ORG Pee pd 4 WED Console Operation n oxese seva nau PR org ERR KEPe Yee MA prre aka oso UN COH ER GERE 6 Power Switch ODBeES Obs ad Vini reed n UON R Dru dd in t E MOD BUR DOG ER RUE 6 Monitor Section eoo HD erp 7 UPS Status PDUO2IPSC Only eeessssssesseeeesssssssssseseersssssssssseseeosssssssssssreeesssssssssseereeesosssssseeeeeeeesssssssseeee 9 Dry Contact Input Indication PDUO2IPSC Only ceti tuat tipa inttr asbl te ne uias 10 System SEGUON ME Cc mH 10 Firewall ors e i o gU NR RR D PROIDENT 15 PECOUIESBELIOEE s nocet ceat Pr b REED pdt ee D or adr eee ene 17 TAMESYNC SECON op ioiii 18 mu eai RT 19 Starlechs i Hard to find made easy Instruction Manual Firmware Upgrade Procedure ccsscccsssscsssscssssccsssscssssscsssssccsssseees 22 SIQCINCAUIONS NEP m 23 Technical SUD DOF Us sicssscasesccxecnsnccnscasorseveacivessvaseuascaieeuneeis DF NA PEE EN E IURE 24 Warranty InformatiODi oc eec REOR RENI E ER FETIE DR ER A EERNSARU QUE 24 Starlechs ii Hard to find made easy Instruction Manual Product Diagram Rear View Front View PDUO2IP StarTechg om 2 Port IP PDU PDUO2IP Reset Button RJ45 LAN LED In
4. find made easy Instruction Manual Logging In for the First Time The minimum requirement to operate the PDU is to setup the IP Address subnet mask and default gateway which can be done through your web browser or using the IP Search Utility application on the CD Default Settings IP address 192 168 1 10 Subnet mask 255 255 255 0 Default Gateway 192 168 1 1 User name Password admin admin lower case Web Browser Method NOTE The workstation and the PDU must be on the same LAN 1 Open a web browser and input the default IP address 192 168 1 10 2 After the login screen appears enter admin admin for the User name and Password 2E Connect to 192 168 1 10 str name i wv a ia e Remember my password 3 Click on the System tab from the menu bar of the web interface and then click on Network to set the IP address and network info of this device Starlechcom 4 Hard to find made easy Instruction Manual Monitor System T Firewall Account TimeSync Event Upgrade Logout Network Network Setup o IP SET 6 DHCP SET Toss 255 255 0 192 168 1 1 Domai Name Sene Setup IP Search Utility NOTE The workstation and the PDU must be on the same LAN for the IP Search Utility to detect it and the Windows Firewall must also be turned off 1 Open the Windows Control Panel 2 Select Windows Firewall 3 Select Off and then click the OK button 4 5 6 7 Insert
5. following pages you will see a Normal or Abnormal indication Status Illustration B NN System Section Monitor System Firewall Account TimeSync Event Upgrade Network Tab Configure the PDU with a Static IP address or use DHCP Ta Network R4 Mail Server Fix IP Address DHCP Enabled 192 168 1 10 192 168 1 1 Domain Name Server Setup 168 95 1 1 Web Server Setup Starlechg om 10 Hard to find made easy Instruction Manual Http Port Assign the desired HTTP port default is port 80 for connecting to the PDU via a web browser If you change the HTTP port enter the IP address followed by the new HTTP port into your browser address bar e g http 192 168 1 10 8080 Save Saves all changes Mail Server Tab Configure the Mail Server settings to send notifications when an event has occurred Ta Network Y4 Mail Server E SMS Server SNMPISysLog lt gt Detectors Email Server Setup e dO CC Y E e NNNM SMTP Server Address Enter the Hostname or IP address of the SMTP Mail Server that will be used to send emails from the PDU If entering a Hostname you will also be required to enter the DNS Address on the Network tab SMTP Port Enter the port number for the SMTP server The default port is 25 Sender Mail Address This must be a legitimate email address Mail Subject Enter a subject line to easily identify the device SMTP Auth Check this box if the M
6. monthly weekly or daily at a specific time for each individual outlet Time Set the time hours and minutes when you want the action to occur Action Set the action you want the outlet to perform ON OFF or Reboot ADD Click the ADD button to add this action Delete To delete a scheduled action double click on the X Save Saves all changes Network Tab Configure the Auto PING feature to ping an IP addressable device and detect when that device has stopped communicating Click on the Set button located on the top corner of each outlet to modify an individual outlet When the Set button is orange the outlet is ready to be configured IWeonfiguration ES Schedule e Network Detect Equipment Network Address PING Interval Time Detect Times Reboot Re detect Time Save Detect Check this box to enable the Auto Ping function Equipment Network Address Enter the IP address of the connected equipment PING Interval Time Set the time Interval to PING the connected device Detect Times If a device fails to respond to a ping continuously and exceeds the specified amount of attempts the PDUO2IPxx can notify selected personnel via email or SMS Reboot Check this box to reboot the outlet for the failed connected device Re detect Time The time interval before restarting the Auto Ping function after the connected device has been rebooted Save Saves all changes StarTechg orn 8 Hard to find made easy Instru
7. Hard to find made easy Instruction Manual Firewall Section Monitor System Firewall Account TimeSync Event Upgrade Logout Y IP Filter This menu allows the administrator to configure user privileges and prevent unauthorized access to the device IP Filter Tab Configure the range of IP addresses that are able to access the PDU T IP Filter Y1 ilte IP Filter Setup Allow IP Address Delete 192 168 BE 207 207 ADD IP Filter Enable Check this box to enable the IP address filter Allow IP Address The first four sections are the beginning of the IP range The last section is the ending of the IP range that is being given access to the device E g To authorize the IP range from 192 168 1 110 192 168 1 120 input as shown in the image above ADD Click ADD to place the entered address range in the table Delete To delete a specific IP address range click on the X Save Saves all changes Starlechg om 15 Hard to find made easy Instruction Manual MAC Filter Tab Configure a specific list of MAC addresses that are able to access the PDU iP Filter Y MAC Filter NIAC Filter Enable MAC Filter Enable Check this box to enable the MAC address filter Allow MAC Address Enter the MAC address of the user s that you want to have access to the PDU The default MAC address is the MAC address of the computer that you initially used to setup the device ADD Click ADD to place the en
8. P Address a as SNMP Test Syslog Notification Syslog Server Address OOOO _ ee ee SYSLOG Test System Name Enter the name of the SNMP device System Contact Enter the name of the System Administrator System Location Enter the location of the SNMP device Receiver IP Address The IP Address of the NMS of where the Traps should be sent Receiver Port The port that will be used to receive the Traps The default value is 162 Community Low level password of the associated IP address with the access type set by the administrator Enabled Enables the SNMP Traps to be sent SNMP Test This is used to verify that the Trap notification works properly Syslog Server Address The IP Address of the Server to which the System Logs should be sent Syslog Server Port The port that will be used to receive the System Logs Save Saves all changes Starlechg om 13 Hard to find made easy Instruction Manual Detectors Tab PDUO2IPSC Only Other Tab Set the outlets on the main tab to default to a reboot action instead of ON OFF Reboot power switch Reboot Option E Reboot Device Reboot Option Check this box to default to rebooting the outlet instead of just turning the outlet ON OFF The Reboot check box on the Monitor screen will be checked when this option is selected Reboot Device Selecting this option will immediately reboot the outlets Save Saves all changes Starlechg om 14
9. Starlechs Hard to find made easy 2 Port Remote Power Control IP PDU Power Distribution Unit 2 Port Remote Power Control IP PDU with Console and Sensor Ports PDDUOZIPZ PDUOZIPSC PDUOZIP shown in photo DE Bedienungsanleitung de startech com FR Guide de l utilisateur frstartech com ES Gu a del usuario es startech com IT Guida per l uso it startech com NL Gebruiksaanwijzing nl startech com PT Guia do usu rio pt startech com For the most up to date information please visit www startech com Manual Revision 01 02 2014 FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the e
10. ail Server requires authentication to send emails SMTP Account Enter the account name if SMTP authentication is required SMTP Password Enter the password if SMTP authentication is required Mail Test This is used to verify that the email works properly Save Saves all changes StarTechy om 11 Hard to find made easy Instruction Manual SMS Server Tab Configure the SMS Server settings to send text notifications when an event has occurred SMS Server SNMP SysLog lt gt Detectors Message Server Setup pene aa ee eee Server Address Enter the SMS server address Port Enter the port number for the SMS server The default value is 2500 Equipment Name Enter a name subject to identify the device Account Enter the account name if required Password Enter the password if required Send SMS Check this box if SMS Server requires authentication to send messages SMS Test This is used to verify that the SMS works properly Save Saves all changes Starlechg om 12 Hard to find made easu Instruction Manual SNMP SysLog Tab Configure SNMP Traps and System Logs to be sent to different Network Management Stations NMS ic SNMP SysLog MIB System SNMP Enable o a 2 Community String public System Name SmartPower 2L Remote Power Coll System Contact Administrator System Location Office TRAP Notification Receiver IP Address ___Receiver I
11. ation on all StarTech com products and to access exclusive resources and time saving tools StarTech com is an ISO 9001 Registered manufacturer of connectivity and technology parts StarTech com was founded in 1985 and has operations in the United States Canada the United Kingdom and Taiwan servicing a worldwide market
12. ck the Browse button 2 Navigate to the location of your previously saved cfg bin file the click Open Choose file Look in E My Documents ex E3 ii My Music A My Pictures My Recent RS My Videos Documents B 3 SP V 1 0 060102 EN Desktop r My Documents J7 T My Computer My Network File name cig z Place Files of type Al Files Cancel 3 Click the Upload button to begin Once the upload is complete the PDU will restart automatically Starlechg om Instruction Manual 21 Hard to find made easu Firmware Upgrade Procedure murem Firmware Upgrade x 192 168 1 10 el r Praduction D ata Production N ame SP2S IP Address 2168110 Subnet Mask 255 255 2550 MAC Address 00 1F 36 BE 26 6F Current Firmware Version 2009130 r Firmware File Data File Type System Production N ame SP25 Firmware Version 201 30502 Firmware File ICAU sers T est Lab Desktop SP25_2 0 130502_Eh PassWord Reboot ya nce Open the firmware_upgrade exe program located on the included CD Input the IP Address of the PDU Click on the GetVersion button Click on the browse button to select the new firmware file bin Input the password default is admin Click on the Upgrade button to start the process Once the firmware upgrading process is complete the PDU will reboot CON OM d UL N
13. ction Manual UPS Status PDUO2IPSC Only The UPS Status information will display to the left of the power switches on the Monitor Tab If you have connected an APC Smart UPS series device to the RS232 port on the PDUOZ2IPSC you can monitor the following information about your UPS Replace Battery Alive Displays the state of the UPS device as either Normal 1 or Offline 0 Model Displays the connected UPS model AC Fault Displays if there is an AC fault causing the equipment to function on UPS battery power Normal 0 AC Fault 1 Output Overload Displays either Normal 0 or Overload 1 state Overload is shown if the power draw exceeds the output limit set by the UPS when operating on battery power Battery Level Displays the remaining battery capacity as a percent value Battery Run Time Min Displays the remaining battery capacity in minutes Battery Low Displays either Normal 0 or Low 1 state the Low state threshold is set by the UPS Replace Battery Displays either Normal 0 or Needs Replacement 1 the Needs Replacement state threshold is set by the UPS StarTechs 9 Hard to find made easy Instruction Manual Dry Contact Input Indication PDUO2IPSC Only The dry contact status information will display to the right of the power switches on the Monitor Tab If you have connected and configured the Detectors information located in System gt Detectors section explained in the
14. dicators PDUO2IPSC Starlechcom 2 Port IP PDU with Console and Sensor PDUO2IPSC Reset Button RJ45 LAN RS232 UPS Console LED Indicators Dry Contact Input StarTechg on 1 Hard to find made easy Instruction Manual Introduction Packaging Contents e 1x2 Port PDU e 1x Power Cable e 1x Instruction Manual CD LED Indicators Port Indicators LED 1 is illuminated when output receptacle 1 is ON Top Row LED 2 is illuminated when output receptacle 2 is ON aoe a s UE m P MR E mo Bottom Left performed Powerindicator Utility Power LED is illuminated when there is an acceptable Bottom Right AC voltage Present Reset Button If you need to reset the PDU back to factory defaults the Reset Button is located next to the LED panel Insert a paperclip to gently press and hold the Reset Button for at least 3 seconds then release Reset Button RJ45 LAN LED Indicators The IP address will be reset back to 192 168 1 10 The user name and password will be reset back to admin All other settings will be unchanged StarTech on 2 Hard to find made easy Instruction Manual Installation Hardware Installation 1 Connect the power cord to the power inlet and to a wall outlet 2 Plug your equipment into the two output receptacles 3 Connect an Ethernet cable from the PDU to your network 4 Turn the power switch to the ON position Optional connections PDUO2IPSC only Starlechg om 3 Hard to
15. discretion The warranty covers parts and labor costs only StarTech com does not warrant its products from defects or damages arising from misuse abuse alteration or normal wear and tear Limitation of Liability In no event shall the liability of StarTech com Ltd and StarTech com USA LLP or their officers directors employees or agents for any damages whether direct or indirect special punitive incidental consequential or otherwise loss of profits loss of business or any pecuniary loss arising out of or related to the use of the product exceed the actual price paid for the product Some states do not allow the exclusion or limitation of incidental or consequential damages If such laws apply the limitations or exclusions contained in this statement may not apply to you Starlechs 24 Hard to find made easy Instruction Manual StarTechg Hard to find made easy Hard to find made easy At StarTech com that isn t a slogan It s a promise StarTech com is your one stop source for every connectivity part you need From the latest technology to legacy products and all the parts that bridge the old and new we can help you find the parts that connect your solutions We make it easy to locate the parts and we quickly deliver them wherever they need to go Just talk to one of our tech advisors or visit our website You ll be connected to the products you need in no time Visit www startech com for complete inform
16. ime Zone Adjust the time difference between Greenwich Mean Time and your country into this format Save Saves all changes Event Section Monitor System Firewall Account TimeSync Event Upgrade Logout Time Kind Message VIGET SE O55 6 Port 2 2nd Outlet Power Off Operator Local User admin 192 168 1 9 control by owser This menu displays the events that have occurred with the PDU Refresh Check for new events Download Save the event log information csv format Delete Clear the event log Instruction Manual StarTechg om 19 Hard to find made easy To Download save the configuration file 1 Click the Download button then select Save from the window that pops up File Download x Do you want to save this file Name cfg bin Type Unknown File Type 768 KB From 192 168 1 21 While files from the Internet can be useful some files can potentially harm your computer If you do not trust the source do not save this file What s the risk 2 Select the location you would like to place the file bin format then click Save Save in My Documents My Music A 2 My Pictures My Recent COMy Videos Documents imjsPev 1 0 060102 EN 2 98 File name cfg My Network Save as type bin Document Starlechg om 20 Hard to find made easy Instruction Manual To upload a previously saved configuration file Download Reset Configuration 1 Cli
17. nt Date mm d yyyy Equipment Time hh mm ss 00 26 07 System Time O PC Date mm dd yyyy 104 22 113 PC Time mm ss o NTP Server Address time stdtime gov tw vl New El Date mm dd yyyy 04 22 113 Time hh mm ss 10 12 46 Time Zone Setup Time Zone GMT v 08 v 00 v Save This menu allows the administrator to set the date and time for the PDU Equipment Date Displays the date This field is not editable Equipment Time Displays the time in 24 hour format This field is not editable Sync with PC Check the Sync with PC button to synchronize the PDU s date and time with the PC PC Date The current PC system date PC Time The current PC system time Sync with NTP Server Check the Sync with NTP Server button to synchronize the PDU s date and time with an NTP server NTP Server Address There is a drop down list of some available NTP servers Select the desired NTP server and then click Save If your desired NTP server is not on the list Click on the New button and then enter your desired NTP server address then click OK StarTechy om 18 Hard to find made easy Instruction Manual Explorer User Prompt Script Prompt Cancel Please input NTP Server Address Cancel time xyz com Manual Setup Check the Manual Setup button to manually setup the date and time Date Please enter the date with correct format Time Please enter the time with correct format T
18. quipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Use of Trademarks Registered Trademarks and other Protected Names and Symbols This manual may make reference to trademarks registered trademarks and other protected names and or symbols of third party companies not related in any way to StarTech com Where they occur these references are for illustrative purposes only and do not represent an endorsement of a product or service by StarTech com or an endorsement of the product s to which this manual applies by the third party company in question Regardless of any direct acknowledgement elsewhere in the body of this document StarTech com hereby acknowledges that all trademarks registered trademarks service marks and other protected names and or symbols contained in this manual and related documents are the property of their respective holders Starlech Hard to find made easy Instruction Manual Table of Contents Product Dia ali xcejscaseessesnacaesecasnescsnsvecacspisenssaevnesceassnemanineaneneaereiannenses 1 hirci v o 1 pio pid dn er 1 Introduction Pe 2 Packaging CONTENTS uada tse etri en inten pei aet cidit E dauid de 2 LED IndICaEOFS securi dtu tiber Mi i SpeE a v yRRIVE Eder Ud RNV EIN IU UII DIR IR VEI R USE
19. tered address in the table Delete To delete a specific MAC address click on the xX Save Saves all changes Starlechg om Instruction Manual 16 Hard to find made easy Account Section Monitor System Firewall Account TimeSync Event Upgrade Logout ID Account Password EM one Mail Address 1 2 This menu allows the administrator to setup authorized user accounts and other privileges The administrator can assign specific access levels for each user account Example The administrator can assign user A to have access to outlet number 1 and receive email notifications when an event occurs to that specific outlet Smart Power 2S allows administrator to set up 2 accounts for management Account Enter the user id for each user account Password Enter the password for each user account Cell phone Enter the contact phone number of the user that will receive the SMS text message once an event has occurred Mail Address Enter the contact email address of the user that will receive the email notification once an event has occurred 1 2 Mark the outlet s that the account can control Del Column Check account s to be deleted Delete Button Delete checked account s Save Saves all changes StarTechy om 17 Hard to find made easy Instruction Manual TimeSync Section Monitor System Firewall Account TimeSync Event Upgrade Logout Equipment Time Equipme
20. the provided CD in the CD ROM drive Launch the IP Search Utility program Click on the Refresh button to search for all PDUO2IPxx units on the LAN Click on the detected PDU and configure the IP address Gateway and Net Mask then click the Configure button twice You will see the values you specified populate in the main window 8 Repeat step 7 for each device if you have multiple PDUO2IPxx units connected 9 Once all devices are configured close the IP Search Utility program and turn the Instruction Manual Windows Firewall back on Starlechg om 5 Hard to find made easy Web Console Operation Power Switch Operation The global outlet controls can be used to either turn all outlets on or all outlets off while each individual outlet allows for On Off Reboot controls All ON 2nd Outlet Double clicking the ALL ON button will turn ON both outlets Double clicking on the ALL OFF button will turn OFF all of the outlets Double clicking the switch for Port 1 or Port 2 will flip the switch to the opposite state ON OFF for that individual outlet If you want to Reboot cycle off then back on an individual outlet check the Reboot box and then double click on the switch Not Authorized ON OFF No Power User account Ir AO E l i m OFF Instruction Manual Sta rlechsom 6 Hard to find made easy Monitor Section The Monitor section shows you the current status of each outlet and allows you to

Download Pdf Manuals

image

Related Search

Related Contents

Intel DC P3600  Consultar Documentos Contables desde PSCD  RX2 AP: Ricevitore radio 2 canali  AVerMedia  取扱説明書  Service Manual  

Copyright © All rights reserved.
Failed to retrieve file