Home
ARGO Over
Contents
1. Remove the drainage hole cap at the bottom on the right and connect a little tube through which drain the condensate place the other end on top of a normal reservoir Ensure that the tube is not twisted or bent The tube must slope downwards Close the drain again with the cap and restart using the air conditioner Dehumidification ATTENTION When using the air conditioner in Dehumidification mode we recommend always ensuring continuous drainage in order to guarantee maximum dehumidification efficiency To empty the tank switch the air conditioner off and unplug it Remove the drainage hole cap below the filter on the side and connect a little tube through which drain the condensate place the other end on top of a normal reservoir a LED a Dehumidification gt a n EESE EE 1 ON OFF BUTTON POWER Signal receiver 2 COOLING MODE SELECTION BUTTON 3 DEHUMIDIFICATION MODE SELECTION BUTTON 4 FAN MODE SELECTION BUTTON amp 5 LOW FAN SPEED SELECTION BUTTON 6 MEDIUM FAN SPEED SELECTION BUTTON 7 HIGH FAN SPEED SELECTION BUTTON FOR OPTIMAL REMOTE CONTROL FUNCTION POINT IT TO THE RECEIVER ON THE AIR CONDITIONER PLACED ON THE RIGHT OF THE LEDS HIDDEN UNDER THE TOP RING V 03 14 16 REMOTE CONTROL BATTERY Insert the battery into the remote control respecting polarities specified Only use type CR2025 batteries 3 V Li in accordance with European Dir
2. disposal of an electrical appliance prevents potential negative effects on the environment and human health resulting from inadequate disposal and also allows the materials from which it is made to be recovered and recycled in order to achieve significant savings in terms of energy and resources The separate disposal obligation is underlined by the crossed out dustbin symbol appearing on the product Illegal disposal of the product by the user shall result in the application of administrative sanctions as defined by current regulations improve your life www argoclima com V 03 14 18
3. to a window as possible keeping a minimum distance of 50 cm from walls or other nearby obstacles FITTING HOSE FOR AIR EXPULSION Insert the terminal connector to be placed between the window leafs on the hose rotating the connector counter clockwise according to the arrow 1 Then connect the air discharge hose complete of the terminal connector to the connector with the magnet that must be placed to the hot air outlet on the unit always turning it counter clockwise according to the arrow 2 Connect the hose complete with connectors to the unit 3 To remove the hose turn it clockwise V 03 14 13 USE WITH TERMINAL CONNECTION FOR WINDOW Connect the end part of the flexible hose 5 to the flat connector 4 Open the windows and block one of the two leafs with the handle Rest the terminal connection on the fixed leaf bring the other leaf of the window close antl Avoid tight curves and folds in the flexible hose Connect the power cord to a suitable electrical socket 220 240V HOW TO USE THE APPLIANCE This appliance can be used to Cool Dehumidify and Ventilate In changing from one mode to another the fan continues to operate but the compressor stops the compressor starts up again 3 and a half minutes later This delay in start up protects the compressor from any damages HMI Hl A Using it as room air conditioner Using it as Spot Cooler or Dehumidifier with flexib
4. CE LOCAL AIR CONDITIONER OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference V 03 14 GENERAL OPERATING AND SAFETY INSTRUCTIONS e This appliance is a portable air conditioner designed for domestic use Only use this air conditioner as described in this manual Ensure that the required voltage and frequency 220 240V 50Hz match the available power supply Ensure that the electricity system is able to deliver the operating current needed by the air conditioner in addition to that normally absorbed by other appliances electrical appliances lighting etc Please refer to the maximum absorption data given on the air conditioner data plate e Connection to the electricity supply must take place in accordance with current installation standards Ensure that the automatic switches and system protection valves are able to withstand a start up current of 7A normally for less than 1 second e The system socket must always be grounded e Make sure the plug is inserted properly Do not use multiple sockets Do not touch the plug with wet hands Make sure the plug is clean e Do not use the pl
5. bjects on the top and if possible protect the air conditioner with a sheet of plastic 4 Transport If not possible lie it on its right side when you reach your ih destination immediately return the appliance If possible transport the air conditioner in a vertical position to a vertical position and wait at least 4 hours before using it Me 5 For complete safety regularly check the condition of the power cord if it should be damaged through use to replace it contact the Service Centre ADVICE FOR MAXIMUM COMFORT AND MINIMUM CONSUMPTION CHECK that e the unit suction and delivery grilles are always free e the air filters are always clean a dirty filter will decrease the passage of air and reduce the unit performance e doors and windows are closed to avoid the infiltration of unconditioned air e the flexible hose is correctly positioned without sharp bends or curves F GAS REGULATION EC no 842 2006 Do not release R410A into the atmosphere R410A is a fluorinated greenhouse gas covered by the Kyoto protocol with a global warming potential GWP of 1975 INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2012 19 EU When this appliance reaches the end of its useful life it must not be disposed of with household waste It must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service Separate waste
6. ective 2006 66 EC supplied with the remote control Remove the battery if the remote control is not used for a month or longer Do not attempt to recharge the battery Do not throw the battery onto a fire it may explode HOW TO INSERT REMOVE THE REMOTE CONTROL BATTERIES refer to the diagram below Open the battery cover at the rear of the remote control press and pull the cover Place the battery into the cover observing the correct polarity Insert the cover on to the remote control Coa INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN waste It must be must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service Separate waste disposal of batteries prevents potential negative effects on the environment and human health resulting from inadequate disposal and also allows the materials from which it is made to be recovered and recycled in order to achieve significant savings in terms of energy and resources The separate disposal obligation is underlined by the crossed out dustbin symbol appearing on the battery Illegal disposal of the product by the user shall result in the application of administrative sanctions as defined by current regulations DIRECTIVE 2006 66 EC Please replace batteries when flat at the end of their useful life batteries must not be disposed of with unsorted maa CARE AND MAINTENANCE WARNING Before carrying out any c
7. ing on remote control keys corresponding to the low Q medium ul or high speed NOTE The air conditioner does not cool the environment when operating as a dehumidifier Dehumidification mode is recommended in autumn and winter If used in summer it is better to leave the flexible hose attached in order to send the hot air outside rather than releasing it into the environment During dehumidification it is better to ensure continuous drainage see paragraph entitled HOW TO ELIMINATE CONDENSATE IMPORTANT When the LED Ventilation far right flashes slowly 1 on 1 off the unit is in DEFROST mode It can happen when operating in cooling and dehumidification the unit stops and resumes operation just ended up defrosting HOW TO ELIMINATE CONDENSATE This equipment automatically vaporises the condensation in Cooling mode Ensure that when the unit operates as Cooling the rubber caps that close the discharge holes on the sides and the rear are correctly positioned When the air conditioner works in Cooling there is no need to arrange for continuous drainage of condensate only in specific weather conditions where air humidity levels are very high may water deposit within the unit When the internal tank is full the three white LEDs positioned on the top ring will light up simultaneously to warn that it is full and the unit stops working V 03 14 15 Cooling To empty the tank switch the air conditioner off and unplug it
8. is 2 3 4 D Upper air filter Cold air inlet Bottom air filter Hot air inlet Horizontal motorized flaps SIDE VIEW Upper air filter Cold air inlet Condensate drain hole Dehumidification Bottom air filter 0 Hot air inlet Fa es a a REAR VIEW 11 Control panel button for operation without remote control POWER 12 Cool and or dehumidified air outlet 13 Hot air outlet 14 Connector with hooks and magnet to be placed on the unit on the hot air outlet 15 Air expulsion hose 16 Terminal connector a b pb a4 17 Small door to be kept open in Cooling mode to be closed in Dehumidification mode only Operation limits min max indoor temperature 18 Condensate drain hole Cooling Cooling 17 C D B 13 C W B 32 C D B 23 W B Dehumidifying 5 C D B 32 C D B V 03 14 hose the terminal connector divided in two parts a 12 APPLIANCE START UP Elements supplied with the unit shown in the box here below Slim Remote control Battery for remote control Type CR2025 3V Lithium Connector with magnet to be Flexible hose for hot air expulsion Terminal flat connector to be placed on the hot air outlet on connected to the flexible hose the unit after having connected and to be placed between the the flexible hose complete of window leafs the terminal flat connector a b 3 S Place the product vertically on a stable flat surface as close
9. le hose connected without flexible hose THE DISCHARGE TUBE MUST BE CONNECTED to the unit when it is used as ROOM AIR CONDITIONER IMPORTANT When using it as SPOT COOLER or as DEHUMIDIFIER the hose must not be connected in the specific case of use as a dehumidifier you must also close the door at the outlet of the hot air in this way the hot air is ducted upwards and mixes with cool air thus increasing the effectiveness of dehumidification Clean the air filters under the side flaps regularly to keep the air conditioner working efficiently V 03 14 14 OPERATING MODES amp MODE SELECTION 1 COOLING MODE Press the key Power on the control panel or on the remote control to enter into Cooling mode the white LED at the far left on the upper ring of the unit will light indicating Cooling mode operation Then select the ventilation speed pressing on remote control keys corresponding to the low Q medium ul or high speed 2 DEHUMIDIFICATION MODE Select Dehumidification mode on the remote control the white LED in the centre on the upper ring of the unit will light indicating Dehumidification mode operation Fan speed is fixed to low and cannot be adjusted 3 FAN MODE Select Fan mode on the remote control the white LED at the far right on the upper ring of the unit will light indicating Fan mode operation Then select the ventilation speed press
10. leaning or maintenance unplug from the electric socket 1 Cleaning the air filters The air filters must be checked at least once every two weeks of use Operating with dirty or blocked filters will decrease the effectiveness of the air conditioner and can cause serious problems To remove the filters open the flaps without forcing them and pull them delicately upwards Use a vacuum cleaner to remove dust If this should not sufficient wash the filters with warm water and a neutral detergent if necessary Rinse with cold water and leave to air dry before replacing Once the two filters have been replaced close the grilles once again and return to use the air conditioner Ce 2 Cleaning the casing RY Use a damp and soft cloth to clean the exterior surface of the air conditioner rll Do not use water that is too hot solvents petrol or other aggressive chemical Ig ne compounds talcum powder or brushes these may damage the surface or colour EE of the casing To remove stains use warm water with a little neutral detergent Do not pour water onto the air conditioner to clean it this may damage the internal components or cause a short circuit NO E V 03 14 17 3 Storage When you do not envisage using the air conditioner for a long time before storing it away clean the filters Keep the appliance in a vertical position at all times Do not rest heavy o
11. tarts once 3 5 minutes have passed from its previous stop Please wait at least 3 5 minutes before starting the unit This helps prevent the compressor from being damaged WARNING In the event of an anomaly switch the appliance off and unplug from the socket Do not dismantle or attempt to repair or modify the product In the event of a malfunction contact the after sales service centre directly WARNING e Do not expose the air conditioner to direct sunlight as the colour of the materials may change and if the appliance overheats this may activate the protection mechanism causing it to switch off e Do not use insecticides oils detergents or spray paints near the appliance do not use aggressive chemical detergents to clean the casing this may damage the finish and colour e Close all open windows to maximise air conditioning efficiency The manufacturer will not be held liable if safety and accident prevention rules are not observed V 03 14 11 INSTRUCTIONS TO REMOVE THE PACKAGING 1 Place the unit in the correct upright position before unpacking 2 Cut the two packing straps 3 Slide the carton upwards and remove the product from the base 4 Pull from the bottom of the package the flexible and b and the connector with the magnet to be placed on the unit to connect the hose 5 Install the exhaust hose on the unit before operating the unit in Cooling mode DESCRIPTION OF THE APPLIANC a FRONT VIEW
12. ug to start stop the air conditioner use the power button on the remote control or on the control panel e Do not install the air conditioner in rooms that may be subject to water sprays e g laundries e This appliance is not suitable for people including children with reduced physical sensory or mental abilities unless they are adequately supervised by a person responsible for their safety e Before moving or cleaning ensure that the device is unplugged from the socket e Do not move the air conditioner while it is operating first turn the appliance off check and remove any condensation that may have formed e To turn the appliance off set the remote control to OFF and remove the plug from the socket Only pull on the plug Do not pull the cord e Do not use the appliance if the cord or plug are damaged If the power supply cord is damaged it must be replaced by the service centre in order to avoid any safety risks PRECAUTION e Do not insert any objects into the air conditioner this is very dangerous as the fan turns very quickly e Ensure that air circulates freely around the unit Do not cover the air intake and delivery grilles with drapes or in any way WARNING e The air conditioner must be positioned at least 50 cm from the wall and any other obstacles on a firm flat surface to avoid water leaks e The air conditioner is fitted with a system to protect the compressor from overload This means that the compressor only s
Download Pdf Manuals
Related Search
Related Contents
Alcatel-Lucent OmniPCX Enterprise Communication Cybex® Plate Loaded Seated Calf Owner`s and Service Manual CODIX 529 Operating instructions Digital display with analogue inputs Senseo Senseo HD7854 J:COM 緊急地震速報サービス利用規約 株式会社ジェイコムさいたま 目 OK - Brother Manuel d`installation Fujitsu PRIMERGY TX300 S7 Copyright © All rights reserved.