Eaton Ellipse ECO 1200VA
Contents
1. 2 to cut the supply of power to the devices connected to the battery backup outlets e Lightning protection All outlets whether backed up or simply filtered include surge protection whatever the position of button e Shutdown of the battery backup outlets OD Press button for more than two seconds Ellipse 1200 1600 lt a 614 06803 00 Troubleshooting For further information visit the www powerquality eaton com site or contact after sales support Problem e The battery backup outlets are not supplied with power eThe connected devices are not supplied when AC power fails e AC power is available but the UPS operates on battery power eThe filtered outlets 8 are not supplied e Green button D flashes frequently and audio alarm beeps Green button a2 flashes and audio alarm beeps continuously e Red LED O is on and the audio alarm beeps every 30 seconds e Green LED O is off and the filtered outlets are supplied eThe telephone line is disturbed or modem access is not possible e Red LED OT flashes e EcoControl outlets keep powered when main application Master outlet is stopped Diagnostic e Button E is not lighted on eThe devices are not connected to the battery backup outlets EN e Circuit breaker E located under the UPS has been tripped by an overload on the UPS output e The wall outlet is not supplied e Circuit breaker EI located under the UPS ha
2. Vicroynnka Becnepe6o Horo Mutanna ASI npouwTa Te NHCTpPYKUNIO c npaBunamu MO TeEXHUKe 6esonacHoctu KoTOpbie Heo6xonwvo co6nionarTrb Satem cneny Te yYKa3aHNAM HacTOALYero pyKOBOACTBAa la isl g sal Ellipse Jas vi L deg aiil a ll LYI Li le dii s ll Q Ala Vas g 33 s gall kill zl e Innan installation av Ellipse las instruktionsmanualen inneh llande sakerhetsinstruktionerna och f lj sedan dem F lj sedan instruktionerna som ges i denna manual 2 e Lue n m ohjeet ennen Ellipse asennusta turvallisuusohjeet 3 ja k ytt ohjeet 614 06803 00 Quick start OD 4 4 1200 1600 D S EcoControl A FR DIN 500 650 800 are me d D 09 MMM EcoControl D USB models Quick start Battery disposal and safety e Caution Battery service life is reduced by 50 for every ten degrees above 25 C e The battery elements must be replaced exclusively by qualified personnel risk of electrocution with new elements approved by EATON to ensure correct operation of th
3. of the button LLI
4. e UPS Battery change F USB models ei Register warranty at powerquality eaton com eThe battery must be disposed of in accordance with applicable regulations To remove the battery elements shut down the UPS button OFF remove the power cord and proceed as indicated in page 4 Battery change Ellipse 500 650 800 e Warning take care not to inverse the polarity red and black when connecting the batteries as this will destroy the device 614 06803 00 Technical characteristics Ellipse ECO 500 650 800 1200 1600 e UPS power 500 VA 650 VA 800 VA 1200 VA 1600 VA 300 W 400 W 500 W 750 W 1000 W e Nominal input voltage 184 V 264 V adjustable to 161 V 284 V e Input frequency 50 60 Hz 46 70 Hz working range e Voltage frequency of battery backup 220 V 230 V 240 V 15 20 50 60 Hz 1 outlets in battery mode e Total output current for all outlets 10 A max e Output current of battery backup 2 3 A max 3 A max 3 6 A max 5 5 A max 7 3 A max outlets e Leakage current 0 4 mA e Input protection 10 A resettable circuit breaker e Transfer time 5 ms typical e Telephone surge protection Tel ISDN ADSL Ethernet e Sealed lead acid battery 12 V 4 5 Ah 12 V 7 Ah 12V 9 Ah 2x12V 7 Ah 2x12V 9 Ah e Automatic battery test Once a week e Average battery life 4 years typical depending on temp
5. erature and amount of discharge cycles e Operating temperature 0 to 35 C e Storage temperature 25 C to 55 C e Operating relative humidity 0 to 85 e Operating elevation 0 to 2000 m e Safety standards IEC 60950 1 IEC 62040 1 CE certified e Electromagnetic compatibility IEC 62040 2 C1 standards e Warranty 2 years e Dimensions mm 263 x 81 x 235 305x81x312 e Weigth Kg 2 9 3 6 6 7 78 Warning Output cables should not exceed 10m length Performances tested according to IEC 61643 1 class 3 standard for 8 20 us surge wave AC input source protection 500 650 800 1200 1600 Ellipse ECO e Uoc 6kV 2kV 6 kV 1 8 kV common mode differential mode e Up 1 8 kV 0 7 kV 1 5 kV 1 kV common mode differential mode eln 3kA Dielectric isolation e AC Ground 1500 Vac 50 Hz e AC TEL 3000 Vac 50 Hz eTel Ground 1000 Vac 50 Hz Temporary overvoltage TOV e Uc 250 Vac e Ut 430 Vac Energy dissipation 461 Joules 614 06803 00 ENGLISH Operating conditions e This product is an Uninterruptible Power Supply UPS for computers and their peripherals television sets stereo systems and video recorders It must not be used to supply other electrical equipment lighting heating household appliances etc e UPS can be installed in horizontal vertical position or placed in Rack 2U optional kit UPS connections e Connect the UPS WR to the AC power system via a wall outlet with an earth con
6. he Master outlet computer is shut down the EcoControl outlets are 6 automatically deactivated and the peripherals shut down This function deactivated by default is validated and configured using the configuration tool integrated in the software Note When the function is activated do not connect critical applications to EcoControl outlets Threshold setup A default setup ensures the correct operation of the EcoControl function However depending on the consumption of the main load the trigger threshold of the EcoControl function may have to be modified using the configuration software supplied with the UPS e First make sure that the function is activated in the EcoControl Function tab of the configuration tool e If the peripherals connected to the EcoControl outlets do not switch off when the main load is not in normal operation ex when in standby mode the detection threshold value must be set to High e If the rated consumption level of the main load is low and the EcoControl outlets shut down when the main load is operating normally the detection threshold value must be set to Low Operation Filtered outlets Battery backup outlets LED ON indicate that surge protection is active LED ON indicate a UPS fault ON OFF button for the battery backup outlets Protection circuit breaker e Battery charge The UPS charges the battery as soon as it is connected to the AC
7. nector using the supplied cord for a UPS with FR DIN sockets or with the supply cord of your computer for a UPS with IEC sockets see figure A e Plug critical equipment computer monitor modem etc into the outlets providing battery backup power and surge protection see figure B taking care not to exceed the rated current indicated in amperes e Other devices printer scanner fax etc can be connect to the filtered outlets 8 that provide surge protection see figure B The filtered outlets are not backed up by battery power in the event of a power outage e Optional Internet modem Network connection A modem or Ethernet data line can be protected against surges by connecting it via the UPS Connect the existing device cable between the wall outlet and the UPS and use a similar cable between the UPS and the device as indicated in figure C cable not supplied e Optional USB connection The UPS device can be connected to the computer using the USB cable 6 supplied The software is available on the CD ROM 5 or downloadable from powerquality eaton com see figures D and F Register for the warranty on powerquality eaton com Master and EcoControl outlets operating procedure In order to limit energy consumption of peripherals scanner printer in standby mode the Ellipse ECO is equipped with EcoControl outlets that are dependent on the Master outlet When the main application supplied by t
8. o the UPS battery due to large variations in the AC supply voltage e Accessing the programming mode with the device switched off press button for 6 s and release it once LEDs have come on e Display of the 3 possible voltage ranges according to the status of LEDs and z Normal mode Low range Low and high factory mode range mode configuration AC supply AC supply AC supply between 161V between 161V between 184V and 264V and 284V and 264V D oN 2 ON A oN 2 OFF 11 OFF 12 ON E CA mu gt CA zx I gt A zA l O OOE DOC Change from one mode to another by successively pressing button 3 e Memorizing the mode 10 s after the last press of the button 614 06803 00 Audio alarm e Possibility of deactivating the audio alarm when the UPS is operating on the battery e Accessing the programming mode with the device switched off press button for 11 s and release it when the audio alarm sounds e Display of the 2 possible audio alarm modes Silent mode the UPS emits a single beep when switching to battery operation and then remains silent Normal mode factory configuration the UPS emits a beep every 10 s when operating on its battery Normal mode Silent mode activated gt activated programming by programming by a continuous beep beep every second Change from one mode to another by successively pressing button e Memorizing the mode 5 s after the last press
9. outlet whether button is pressed or not When used for the first time the battery will only provide its maximum OOGO Ellipse 500 650 800 autonomy after it has been charged for 8 hours It is recommended that the UPS be permanently connected to the AC power supply to ensure the best possible autonomy e Switching on the UPS press button for about 1 second e Filtered outlets 8 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord is plugged in They are not affected by button EI e Battery backup outlets EN Equipment connected to these outlets is supplied as soon as button turns green see figure E These outlets can be turned on even if the UPS is not connected to AC power button flashes e AC power disturbance If AC power is disturbed or fails the UPS continues to operate on battery power Button a2 flashes green In normal mode the audio alarm beeps every ten seconds then every three seconds when the end of battery backup time is near In silent mode see the section on settings the audio alarm simply beeps once when the UPS transfers to battery power e If the power outage lasts longer than the battery backup time the UPS shuts down and automatically restarts when power is restored Following a complete discharge a few hours are required to recharge the battery back to full backup time e To save battery power it is possible to press button
10. pse ler o caderno onde constam as instru es de seguran a a respeitar Depois seguir as instru es do presente manual piv tnv eykat otaon Tou Ellipse dtaBdote TO PUAAGSIO HE TIG ouBouA c aoga sia mou rp rtgi va Tnpeite Zm ouv xeta AKOAOUGN TE Tic Odnyies Xprions autod tou puAAadiou 2 e Przed zainstalowaniem Ellipse nale y przeczyta instrukcj 3 kt ra zawiera niezb dne zalecenia bezpiecze stwa Nast pnie nale y zapozna si z zaleceniami zawartymi w niniejszej instrukcji e P ed instatac zdroje Ellipse si prostudujte p ru ku Gi kde najdete bezpe nostn p edpisy kter je t eba dodr ovat D le postupujte podle pokyn uveden ch v p ru ce e Pred in tal ciou v pustky si pre tajte kni ku v ktorej s uveden bezpe nostn pr kazy ktor je potrebn dodr a Potom postupujte pod a pokynov tejto pr ru ky 2 e Preden instalirate Ellipse preberite knji ico 3 v kateri so varnostna navodila ki jih je treba upo tevati Nato sledite navodilom tega priro nika e Az Ellipse telep t se el tt olvassa el a es k nyvet mely a betartand biztons gi eldirasokat tartalmazza Ezut n k vesse a jelen 2 s kezik nyv utas t sait e Ellipse in tesisatini yapmadan nce uyulacakg venliktalimatlarini g steren sayili kitap i i okuyunuz Dana sonra isbu sayili ei kitabindaki talimatlara uyunuz e lepen vcranopkon
11. s been tripped by an overload on the UPS output eThe UPS frequently operates on battery power because the AC power source is of poor quality eThe UPS battery backup outlets are overloaded e A fault has occurred on the UPS The battery backup outlets are no longer supplied e Surge protection is no longer provided e Surge protection on the telephone line is no longer provided eThe battery has reached the end of its service life e EcoControl function is not activated or not properly set Advanced customizing of your UPS Solution e Press button 02 and check that it turns green ag Kal e Connect the devices to the battery EI backup outlets 9 e Disconnect excess equipment and reset the circuit breaker E by pressing the corresponding button e Supply power to the wall outlet e Disconnect excess equipment and reset the circuit breaker by pressing the corresponding button e Have the electrical installation checked by a professional or use another wall outlet e Disconnect excess equipment connected to the battery backup outlets e Call after sales support e Call after sales support e Disconnect the telephone line from the wall outlet e Call after sales support e Have the battery replaced e Activate or set properly EcoControl function using the software provided with the product Sensitivity to variations of the AC power supply e Only to be used if frequent switching t
12. www eaton com Ellipse ECO 500 650 800 1200 1600 Installation and user manual English Frangais Deutsch Italiano Espanol Nederlands Portugu s EAAnvike Polski Cesky Solvencina Slovensko Magyar T rk e PYCCKMM gt Svenka Suomi 7 ECN Powering Business Worldwide Packaging FR DIN EC I models A Caution e Before installing the Ellipse read the booklet Si containing the safety instructions to be respected Then follow the instructions given in this manual e Avant l installation de Ellipse lire le livret qui pr sente les consignes de s curit respecter Suivre ensuite les instructions du pr sent manuel 2 e Vor Installation des Ellipse die im Heft GI genannten Sicherheitsvorschriften lesen AnschlieBend die Anweisungen im vorliegenden Handbuch befolgen e Prima dell installazione del Ellipse leggere attentamente le istruzioni di sicurezza riportate sul libretto In seguito attenersi alle istruzioni riportate sul presente manuale e Antes de la instalaci n del Ellipse leer el manual que presenta las instrucciones de seguridad a cumplir A continuaci n seguir las instrucciones del presente manual e Lees voordat u het Ellipse gaat installeren eerst de veiligheidsinstructies in boekje Volg daarna de instructies van deze handleiding 2 e Antes da instala o do Elli