Home

Technoline WS 9251 weather station

image

Contents

1. press it to stop the current alarm and activate snooze 3 ALARM SET key Press it to display alarm time for 5 seconds During alarm time displayed press it to turn on off alarm function Press and hold it for 3 seconds to enter alarm setting mode In alarm setting mode press it to step the setting item and press it to save and exit the setting 4 CH key In normal mode press it to select channel 1 to channel 3 Press and hold it for 3 seconds to turn to channel auto change mode Press it again to return to normal mode In setting mode press it to adjust the value of the flashing digit upwards And press it without releasing to speed up the setting 5 MEM key In normal mode press it to check the max min indoor and outdoor temperature record for 5 seconds Press and hold it for 3 seconds to delete the max min temperature record In setting mode press it to adjust the value of the flashing digit downwards And press it without releasing to speed up the setting 6 DISPLAY SET key In normal mode press and hold it for 3 seconds to enter time setting mode In time setting mode press it to step the setting item and press and hold it for 3 seconds to save and exit the setting 7 C F slide switch Select temperature unit between C F 8 SENSOR key Press it to start 433 MHz channel test for main unit amp transmitter During the channel test press and hold it for 3 seconds to manual
2. turn off 9 RCC key Press it to manual receive RC signal During the RC reception press and hold it for 3 seconds to turn off synchronisation 10 RESET key In case of mal function press it by using a metal wire to reset all the values 11 Battery door TRANSMITTER 1 LED indicator Flashes when the remote unit transmitting a reading 2 CHANNEL slide switch Assign the transmitter to Channel 1 2 or 3 3 RESET key Press it to reset the transmitter 4 Wall mounting holder Use it to support the transmitter on the wall 5 Battery compartment SIGNAL STRENGTH INDICATOR The signal indicator flashing means time signals are being received If the RC weather station receives signal successfully a sync time symbol appears on the LCD The unit has already received the time signal Otherwise the signal strength symbol will disappear from the LCD display Note You may press RCC key to receive the time signal manually The receive mode will be off automatically after 6 16 minutes Receive mode consumes more battery power that may reduce battery lifetime DAYLIGHT SAVING TIME DST The weather station has been programmed to automatically switch when daylight saving time is in effect Your clock will display DST on the LCD during the summer TIME AND CALENDAR SETTING If the weather station does not receive the time signal successfully you can set the time manually As soon as the transmit
3. unit 40 0 70 0 C 40 0 158 0 F 0 45 0 C 32 0 113 0 F 0 1 C F DCF 7 7 40 0 70 0 C 40 0 158 0 F 20 0 55 0 C 4 0 131 0 F 0 1 C F 433 MHz Maximum 50 meters Up to 3 units Around 60 64seconds 3V use 2xAA 1 5V battery Remote sensor 3V use 2xAA 1 5V battery DIMENTION Main unit 84 W x141 H x47 D mm Remote sensor 65 W x100 H x35 D mm
4. WS9251 RADIO CONTROLLED WIRELESS WEATHER STATION USER S INSTRUCTION Please read the instructions carefully and keep the manual well for future reference GETTING START Before using the main unit and transmitter 1 Remove the battery door of the main unit and transmitter 2 Install 2 new AA size batteries for both main unit and transmitter according to the polarity mark on the battery compartment 3 Replace the battery door 4 After the batteries are installed all LCD segment will be shown 5 Press the RESET key of main unit first and press the RESET key of transmitter 6 It will automatically receive 433 MHz signal from transmitter for channel test in 8 seconds 7 After 5 minutes channel test it will turn to RC signal reception automatically 8 Radio Controlled function the current time amp date automatically synchronized with the time signal transmitted from Germany DCF77 Note 1 The unit can operate up to 3 remote transmitters 2 Position the unit and transmitter within the effective transmission range 50 meters in usual circumstances 3 In some cases you may not receive the signal immediately you can reset the unit and transmitter again as described above MAIN FEATURES MAIN UNIT 1 LCD display Display of the time alarm time outdoor amp indoor temperature and weather forecast 2 SNOOZE LIGHT key Press it to turn on backlight for 5 seconds When the alarm is sounding
5. eltinq Note 1 In alarm mode the AL icon will display on the LCD 2 The alarm function will turn on automatically once you set the alarm time USING ALARM AND SNOOZE FUNCTION 1 Set the desired alarm time as described in the above section 2 Or press ALARM SET key to display the alarm time press it again to turn on alarm function with the alarm icon displayed on the LCD 3 When clock reach the alarm time alarm sound will start Where it can be stopped by following operation a Auto stop after two minutes alarming if without any operation and it will re alarm by the next day b By pressing SNOOZE key to enter snooze that the alarm will sound again after 5 minutes C By pressing ALARM SET key to turn off the alarm function Note 1 The snooze could be used continuously in 24 hours 2 During the snooze the alarm icon will keep flashing ABOUT THE WEATHER INDICATOR The built in barometer can notice atmosphere pressure changes Based on the data collected it can predict the weather conditions in the forthcoming 12 24 hours Note 1 The accuracy of a general pressure based weather forecast is about 70 to 75 2 The weather forecast is meant for the forthcoming 12 24 hours It may not necessarily reflect the current situation VIEW THE CHANNEL 1 The default displayed channel is channel 1 In normal mode press CH key to check the outdoor temperature from channel 1 to channe
6. l 3 2 Press and hold CH key for 3 seconds to turn to channel auto change mode that the channels change automatically 3 Press CH key again to return to normal mode eb3r cim t nn 45 IC ai Note In channel auto change mode channels change automatically in every 4 second READING INDOOR amp OUTOOR TEMPERATURE RECORDS 1 Push C F switch to change the temperature unit to Celsius or Fahrenheit 2 Press CH key to change the channels among 3 channels and check their temperature Note 1 Once the channel is assigned to one transmitter you can only change it by removing the batteries or resetting the unit 2 If no signals are received or the transmission is interfered will appear on the LCD 3 Relocate the weather station or the transmitter in other positions and make sure the transmission is within the effective range of 50 meters approx 4 After several trials in vain please reset the weather station thoroughly Try out where your multifunctional weather station receives the signals best CHECKING AND DELETING MAX MIN TEMPERATURE REOCRDS 1 Press MEM key to check and keep the maximum minimum temperature record for 5 seconds 2 Press and hold the MEM key for 3 seconds to delete the maximum and minimum temperature records t gS5r abr e sho ag d eH3 7cHi5 00s Meos M200 Current temperature Max temperature Min tem
7. perature Note Once you reset or re install batteries for the main unit all the value will be defaulted ICE ALERT 1 When the outdoor temperature within the range of 2 C 3 C 28 F 37 F the Ice Alert icon UP will display on LCD amp flashing continuously 2 Ice Alert icon will disappear when outdoor temperature out of above temperature range IBN IUJ amp 1 Ice Alert icon BATTERY REPLACEMENT When the LCD becomes dim replace with 2 AA size batteries at once while if the low battery indicator 99 displays in the outdoor window it indicates that the battery power of the transmitter is not enough and you should replace with 2 AA size batteries at once SUGGESTION 1 Everyday the unit will automatically search for the time signal at 2 00 8 00 14 00 and 20 00 2 Always place the unit away from interfering sources such as TV set computer etc 3 Avoid placing the unit on or next to metal plate 4 Closed area such as airport basement tower block or factory is not recommended 5 Do not start reception on a moving article such as vehicle or train A plz we ett ari Ee Pa SPECIFICATION MAIN UNIT Measurement range Recommended operating range Resolution Radio Controlled signal REMOTE SENSOR Measurement range Recommended operating range Resolution RF transmission frequency RF transmission range No of remote sensor Temperature sensing cycle POWER Main
8. ter is received again the weather station will automatically synchronize with the received time 1 In normal mode press and hold DISPLAY SET key for 3 seconds until the Hour format digit flashing 2 Press key to select 12 24 hour format 3 Press DISPLAY SET key again to step the setting item to Hour with the Hour digit flashing 4 Press key to adjust the value of the flashing digit 5 Do the above operation in this sequence 12 24 Hr Hour Minute Second Time difference 6 Press and hold DISPLAY SET key for 3 seconds to save and exit the setting Norma mode 12 24 Hr setting Minute setting Time difference setting Note If your local time is different from the RC received time you can set the desired time difference The available time difference is from 23 hours to 23 hours After setting the desired time difference the weather station will show the time that RC received time plus minus the time difference ALARM TIME SETTING 1 In normal mode press and hold ALARM SET key for 3 seconds until the Hour digit flashing 2 Press key to adjust the value of the flashing digit 3 Press ALARM SET key again to step the setting value to Minute with the Minute digit flashing 4 Press key to adjust the value of the flashing digit 5 Press ALARM SET key to save and exit the setting Alarm time mode Hour setting Minute s

Download Pdf Manuals

image

Related Search

Related Contents

Halsey Taylor 8634088383 Use and Care Manual  156 ,426 156 ,426円 ワンプライス車    ソケットクランプ  Practice Management Face-Off - Time Matters vs. Amicus Attorney  Epson WF-5690 Notices and Warranty    LIMPIA PLANCHAS B.B.  Dossier sur l`éducation intégratrice: matériels de - unesdoc  Honeywell R7824 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file