Home
ASSMANN Electronic DN-650102 network switch
Contents
1. warn the user ex alarm sound or flash light L 12 Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Panel of the switch we r ee 1 Use the screws to screw the DIN Rail on the industrial switch 2 To remove the DIN Rail reverse the step 1 1 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To remove the industrial switch from the track reverse steps above Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse steps above Hardware Installation In this paragraph we are going to mention how to install the 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch and
2. 00 SFP Combo with 8 PoE Injectors Industrial Switch dimension W x D x H is 72mm x 105mm x 152mm Front Panel The Front Panel of the 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch is shown as below 8 10 100TX 2 10 100 1000T Mini GBIC Combo w 8 PoE Injector Industrial Switch 10001 001 01 d4S 0001 00 5 8 oa H Tl v Q a 8 Gam 101007X Front Panel of the PoE Injectors Industrial Switch Top View The top view of the 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch has one terminal block connector of two DC power inputs oe m en urn OORT LRM ELT EE OOO en EEA 0002 he AG Fautt PWR1 NEN N Top View of the PoE Injectors Industrial Switch LED Indicators The diagnostic LEDs located on the front panel of the industrial switch provide real time information of system and optional status The following table provides the description of the LED status and their meanings for the switch Ko os BE BE mo re me en Power input 1 or 2 is inactive OFF Power 1 amp Power 2 are both active or no power inputs Upper sne Blinking Networking is active Not connected to network The port is operating at speed of 1000M Lower LED OFE The port is disconnected or not operating at speed of 1000M Link Active Data is transmitting or receiving P9 P10 Not connecte
3. 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch 8 10 100TX 2 10 100 1000T Mini GBIC Combo w 8 PoE Injector Industrial Switch User Manual DN 650102 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver E Connect the equipment into an outlet on a circuit different from that to which the receiver is connected m Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequ
4. a of industrial switch application For a sample application of the industrial switch see the figures below Human Management Interface Data collect server Enterprise Switch PIFE 802GBTA PIFE 802GBTA Field Management Programmable e i ee II ur fi Field Automatic device Field Automatic device Field Automatic device PIFE 802GBTA Distribute I O control system 17 Uplink via Fiber sos Uplink via UTP STP Power over Ethemet PoE Splitter Power over Ethemet Ethemet Cable Power Cable N PoE Splitter Ethemet Cable Fower Cable Non PoE Devices PoE Industrial Switch Power over Ethemet Power over Ethemet Power over Ethemet VOIP Phone IP Camera Wireless AP IEEE 802 3af Compliant Powered Devices 18 Troubles shooting m Verify that is using the right power cord adapter DC 48V please don t use the power adapter with DC output voltage higher than 48V or it will burn this converter down m Select the proper UTP cable to construct user network Please check that is using the right cable Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections 100Q Category 5 cable for 100Mbps connections or 1000 Category 5e above cable for 1000Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet m Diagnosing LED Ind
5. ate measures Content INIFOQUC EI OU 44474444 1 FEatures rr rrarvarvarrarrarvarvarnannannannannannnrnnnnnnnnnnsnn 1 Package Content ccccccecceceseeeeeeseeeeeeseeeeeeeeeees 2 Hardware Description nrarnnvannnvnnnnnnnnnnnnnnnnnnnnnnnnnenen 3 Physical Dimension arrarnernernornernernernernennennennnnnn 3 Front Panel rarrarvarnornnvnnnernnvnnvnrnennnvnsnnenernsnnsnuenenne 3 Top View esvennernornnvernennnnnrnnrnennannenennennannsnuenennannsnnenere 4 LED Indicators 1 0 0 ccc ccc ccc ccc eeceeeeeee eee eeeeeeeeeeseeseeees 9 PONO vr 6 Cabling arrnnrnannnnrnannnnrnannnnrnannnnrnannnnrnannnernnenasnneeneee 8 Wiring the Power Inputs 0220220020220 sen eeneen 11 Wiring the Fault Alarm Contact 11 Mounting Installation nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnr 13 DIN Rail MOUNTING cccccc eee eeceeceeeeeeeeeeeeeeeees 13 Wall Mount Plate Mounting 15 Hardware Installation aan 16 Installation Steps rrrrannnnnrnnrnanvnnrnvnnernurnunnnnnnsnnee 16 Network ApplicatiOn rannanannnnnunnnnnnnnnnnnnnnnnnnnnnunnen 17 Troubles shooting zen 19 Technical SpecificatiOn rnrannaunannannunaunnunnnnunnunnunne 20 Introduction The 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch is a cost effective solution and meets the high reliability requirements
6. d to network P1 P8 Connected to network ergen Blinking Networking is active Connected to network LED P9 P10 RJ 45 Ethernet port full duplex P1 P8 Blinking Collision of packet occurs Yellow ae Ethernet port half duplex or not connected to network 2 A powered device is connected utilizing Power reen FWD P1 P8 over Ethernet on the port No device is connected or power forwarding fails Ports E RJ 45 ports The UTP RJ 45 Fast Ethernet ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the below figures for straight through and crossover cable schematic E RJ 45 Pin Assignments NOTE and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs 6 Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Transmit Data plus TD Receive Data plus RD Transmit Data
7. demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Features m System Interface Performance gt RJ 45 ports support Auto MDI MDI X Function Embedded 8 port PoE Injection SFP Mini GBIC supports 100 1000 Dual Mode Store and Forward Switching Architecture Back plane Switching Fabric 5 6Gbps 1Mbits Packet Buffer 8K MAC Address Table gt Supports Wide Operating Temperature 40 C 75 C m Power Supply Y VV V V WV gt Redundant Power Design m Case Installation gt IP 30 Protection gt DIN Rail and Wall Mount Design m Relay Alarm gt Relay output for port breakdown power fail and alarm Package Contents Please refer to the package contents list below to verify them against the checklist m 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch User manual Pluggable Terminal Block 2 wall mount plates and 6 screws One DIN Rail attached on the switch User Manual AA SY Wall Mount Plate Screws DIN Rail Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Hardware Description In this paragraph the Industrial switch s hardware spec port cabling information and wiring installation will be described Physical Dimension 8 10 100TX 2 10 100 1000T 100 10
8. icators the Switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying problems m lf the power indicator does not light on when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance m If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit Please check your system s Ethernet devices configuration or status Technical Specification 8 10 100TX 2 10 100 1000T 100 1000 SFP Combo with 8 PoE Injectors Industrial Switch technical specifications is shown as below IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX IEEE802 3ab 1000Base T Standard IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3af Power over Ethernet Protocol CSMA CD 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port 1 488 000 pps for Gigabit Fiber Ethernet port Packet Buffer 1Mbits MAC address 8K MAC address table 8 ports 10 100TX Link Activity Green Full duplex Collision Yellow Power Feeding Green LED Giga port Link Activity Green Per unit Power 1 Green Power 2 Green Fault Red 10Base T 2 pair UTP STP Ca
9. minus TD Receive Data minus RD Receive Data minus RD Transmit Data minus TD 6 Switch Router or PC 3 TD 3 RD 6 TD gt 06 RD 1 RD 4 1 TD 2 RD 2 TD Straight Through Cable Schematic Swi teh Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic m 2 Mini GBIC combo port 2 auto detect Giga port UTP or fiber The gigabit Ethernet ports are shared with the mini GBIC ports UTP Gigabit Ethernet ports can operate in half full duplex modes and work at speeds of 10 100 1000Mbps that support auto sensing technology to enable each port to detect the connecting speed The mini GBIC port is a joint for a mini GBIC SFP transceiver so the switch can be uplinked through fiber to another one Cabling m Use four twisted pair Category 5e or above cabling for RJ 45 port connection The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft long m Use the mini GBIC ports to uplink to another switch by inserting the mini GBIC SFP transceiver To connect the transceiver and LC cable please follow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Pom Mie teg NGS vege Triangle Mark x Line r hind a Figure 2 8 Transceiver to the SFP module Figure 2 9 Transceiver Inserted Second insert the fiber cable
10. of LC connector into the transceiver Figure 2 10 LC connector to the transceiver To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Figure 2 11 Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Figure 2 12 Pull out from the transceiver 10 Wiring the Power Inputs Please follow the steps below to insert the power wire V V V V Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form an open circuit An application example for the fault alarm contact is shown as below Insert the wires into the fault alarm contact Note The wire gauge for the terminal block should be in the range between 12 24 AWG Fault Alarm Contact TEEN patent to The open circuit will form when the i power falls Av DE Buzzer 24 Battery a EE ee EE EEE IE IM TE HN IN NEN BEE HEN BEE The fault alarm device will send a warning signal to
11. ration www assmann co ASSMANN Eon GmbH Auf dem Sch ffel 3 58513 Ludenscheid Germany 22
12. t 3 4 5 5e cable Transfer Rate EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5E cable EIA TIA 568 100 ohm 100m Network Cable 20 Distance Multi mode 0 to 5 km 1300 nm 50 125 um 800 MHz km 0 to 4 km 1300 nm 62 5 125 um 500 MHz km Single mode 0 to 40 km 1310 nm 9 125 um 3 5 PS nm km 0 to 80 km 1550 nm 9 125 um 19 PS nm km Min TX Output Optical cable Multi mode 20 dBm Single mode 0 to 40 km 5 dBm 0 to 80 km 5 dBm Max TX Output Multi mode 14 dBm Single mode 0 to 40 km 0 dBm 0 to 80 km 0 dBm Sensitivity 36 to 32 dBm Single mode 34 to 30 dBm Multi mode Back plane 5 6Gbps Switching Fabric Packet throughput 8 3Mpps at 64bytes ability External Power Supply DC 48V Power Supply Redundant power DC 48V with connective removable terminal block Power 140 Watts maximum Consumption DIN rail kit and wall mount ear for DIN type cabinet ett nn Operating 40 C 75 C Wide Operating Temperature model 10 C 60 C standard model Operating 5 to 95 Non condensing Humidity Storage 40 C to 85 C Temperature Case Dimension IP 30 72 mm W x 105 mm D x 152mm FCC Class A CE EN61000 4 2 3 4 5 6 8 11 12 CE EN61000 6 2 CE EN61000 6 4 UL cUL CE EN60950 1 IEC60068 2 32 Free fall Stability testing IEC60068 2 27 Shock IEC60068 2 6 Vib
13. the installation points to be attended to it Installation Steps 1 Unpack the Industrial switch packing 2 Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If user want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5e above cable for Ethernet connection 6 Insert one side of the RJ 45 cable into the Industrial switch Ethernet port and another side to the network device s Ethernet port e g Switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication 7 When all connections are set and LED lights all show in normal the installation is complete Network Application This segment provides the samples to help user have more actual ide