Home

Grundig Sh 24

image

Contents

1. STOP Recording Start stop voice activated Voice Activation During speech pauses when recording more than 4 seconds the device stops Recording resumes when you speak otherwise like Recording You can set different sensitivity levels for Voice Activation OFF VA off LOW VA for dictation HIGH VA for conference recording Erasing recordings Erasing words or text passages Press and hold down the a DICTATE button Keep slide switch in 4d REWIND position for duration of erasure DICT indication lights up Release a DICTATE button locks in The tape is rewound and is erased Erasure of a steno cassette outside the unit With instant eraser 616 accessories Text Marks End mark During recording it is possible to mark the dicta tions by end marks At the end of the letter briefly press e the INDEX button to record an end mark These end marks are recognized by all GRUNDIG dictation machines provided with the search func tion See chapter Fast Forward Rewind Info mark Record spontaneous ideas information or advice even within a dictation Use messages to communicate with staff Press the INDEX button for a longer time to record an info mark and T release the button to record an end mark The desktop dictation and transcription machine Dt 3230 has special functions for the indication playback and search of text passages whic
2. ENGLISH GRUNDIG Business Systems _______Stenorette Sh 24 Steno Cassette 30 www grundig gbs com CE Die Konformit t mit den f r das Ger t relevanten EU Richtlinien wird durch das CE Zeichen best tigt CE The CE mark confirms that the device corresponds to the relevant guidelines of the European Union CE La conformit con le direttive EU rilevanti per questo dispositivo sono confermate con il simbolo CE CE Le marque CE indique que l appareil est en conformit avec les normes applicables de l Union europ enne CE Het voldoen aan de voor het apparaat relevante EU richtlijnen wordt door het CE teken bevestigd CE CE market inneb r att apparaten uppfyller kraven i relevanta EU riktlinjer CE CE meerket er vores tilkendegivelse om at apparatet er i overensstemmelse med de relevante EU retningslinjer CE La conformidad con los par metros de la UE relevantes para el equipo se confirma con el signo CE INDEX VOL MIC NO OK QW Batterien Batterijen Batteries Batterier Pile Batterierne Piles Pilas Akkuset 462 Rechargeable batteries 462 Accumulatori 462 Accumulateurs 462 Akku s 462 Ackumulator 462 Akkumulator 462 Baterias 462 4 Netzbetrieb Mains operation Funzionamento con la rete Fonctionnament sur secteur Gebruik met de adapter N tdrift Netdrift Funcionamiento a red S
3. can vertically be placed on a table Dictation Ce BE Speak over the dictation machine The figure shows the optimum position of the dictation machine The high quality microphone allows also for recordings over greater distances Microphone position see Fig 1 DICT Indication plus battery rechargeable battery indicator Ligths up during recording Goes out when the batteries rechargeable batteries are exhausted mme Recording Press a DICTATE button locks in Set slide switch to START DICT lights up tape runs Awarning signal sounds if no cassette is fitted and at tape end Recording pause Set the slide switch to D STOP DICT goes out Recording button a DICTATE remains locked in Set slide switch to START DICT lights up tape runs Text correction Switch the slide switch to 44 REWIND The a DICTATE button disengages The tape rewinds until you release the slide switch gt START Please note Atend marks or info marks the unit stops for approx 1 s see Fast forward wind rewind Resuming dictation During START press a DICTATE button locks in at desired text passage DICT indication lights up tape runs Concluding recording Briefly move slide switch to 44 REWIND or gt gt FFWD The a DICTATE button unlocks Set slide switch to
4. charged Controls and Sockets Please open folder at beginning of booklet 1 Playback volume control tum DICT indication Lights up during recording Microphone 4 Recording button Press the a DICTATE button locks in 5 Loudspeaker 6 Switch on lock red gt green Prevents accidental switching on 7 Slide switch Fast forward search O Stop gt Start playback Start recording Press a DICTATE button beforehand locks in Stop recording Set sliding switch briefly to 4d REWIND or gt gt FFWD 44 Rewind search 8 Sliding cover 9 LID LOCK button Press and slide cover down 10 Mains charging unit 679 connection 11 VA switch for voice activated start stop during recording 12 INDEX button end mark Press the button briefly during recording Info mark Press the button longer during recording Index mark Press the button during playback 13 Microphone connection O 14 Earphone connection O 15 Cover Press and slide down ow Do not expose the unit and the steno cassettes to temperatures above 55 C Note on Environmental Protection Do not throw exhausted batteries in the household refuse Hand over the old batteries to your dealer or public collecting points when buying new ones Low energy consumption environment friendly materials environment compliant packing Grundig dictation machines are conceived and fabricated according to the highest environmenta
5. h have been recorded with the info marks Note The recording time between the text marks should be at least 10 seconds to make sure that the search function finds the marks Text Marks Recording brief messages during a dictation You wish to record a brief message during the dictation 1 Press and hold down the INDEX button 2 Speak your message after the info mark 3 Release the INDEX button after your message The end mark sounds You can resume the dictation Recording longer messages You wish to record a longer message or you wish to interrupt a dication by stopping the tape to prepare a message Recording is still switched on 1 Set the slide switch to START 2 Press and hold down the INDEX button This records the info mark 3 After the info mark signal set the slide switch to O STOP 4 Release the INDEX button 5 Set the slide switch to START 6 Dictate your message You can interrupt recording as often as you wish 7 Terminate your message by briefly pressing the INDEX button When releasing the button an end mark will be recorded Text Marks Index mark g ac Note Examples Press the INDEX button during playback when the text passage to be marked is reached The machine records the index mark additionaly without erasing the text Let the person who will do your typing know what to do when an index mark is heard on the tape insert cor
6. l requirements Accessories indicated in the text are not supplied with the unit Please make sure to choose only genuine acces sories from Grundig Product liability and warranty service are provided only in this case The use of non Grundig accessories or those which are not recommended and approved by Grundig automati cally void any warranty claims towards Grundig Switch on lock Switch on lock red gt green Red visible Unit protected against inadverten Switch on Automatic switch off If the machine remains switched on inadvertently the current function is continued till the end of the cassette After emitting several sound signals the machine switches off To put the machine into operation again set the slide switch to STOP then select the desired function Cassette compartment Inserting removing steno cassette accessories Press and hold down the lt 4 LID LOCK button and pull off the sliding cover Remove steno cassette by tilting it out sideways For inserting the steno cassette see figure 1 at the beginning of booklet Close sliding cover Steno cassettes Store steno cassettes in their Multibox transport precaution accessories For dispatch correspondence folder 741 accessories for two steno cas settes and dictation documents DIN A4 Microphone and recording indicator Conference recordings The housing base is designed so that the dictation machine
7. ontamination by tape abrasion see illustration at the end of this booklet If cleaning should be necessary use a cotton wrapround soaked in cleaning benzine Never use a metallic or other hard object Remove the steno cassette from the cassette compartment Switch on device a DICTATE START Warning signal because there is no steno cas sette in the cassette compartment The device switches off Press one of the two bolts A in direction of the cassette compartment Clean the tape contacting parts Rubber pinch roller B capstan C sound head D and erase head E In the event of malfunctions contact your specialised dealer Subject to technical alterations and alterations in styling E and O E 13 Abbildung zum Text Bandber hrende Teile Seite 13 Figure to text tape contacting parts page 13 Figura riferita al capitolo Parti a contatto con il nastro pagina 13 Figure au text El ments au contact avec la bande page 13 Afbeelding bij de tekst Delen die de band aanraken pagina 13 Bild till texten Bandber rande delar sidan 13 Illustration til teksten Bandbergrende dele side 13 llustraci n para el texto Piezas en contacto con la cinta pagina 13 A GRUNDIG Business Systems Grundig Business Systems GmbH Weiherstra e 10 D 95448 Bayreuth Germany 36177 941 0202 02 2015
8. rection tape read enclosed index note call back for consultation 10 Playback Playback Starting playback Set slide switch to START Awarning signal sounds if no steno cassette is fitted Adjust desired volume tum Concluding playback Set slide switch to O STOP 11 Fast Forward Rewind Rewind and fast forward without search Move the slide switch briefly to the desired function gt gt FFWD or 44 REWIND let go of it and then move the slide switch immediately to the desired function again Rewind with search function Set the slide switch to 44 REWIND and hold in place The tape winds backwards and stops when you release the slide switch gt START At end marks or info marks the unit stops for approx 1 s in front of the marking release slide switch START or if you wish to continue rewinding keep slide switch in 44 REWIND position Fast forward with search Keep slide switch in gt FFWD position At end marks or info marks the unit stops for approx 1 s after the marking Release slide switch or if you wish to continue fast forward winding keep slide switch in gt FFWD position 12 Care and Maintenance The housing should only be cleaned with a soft cloth which picks up dust Polishing or cleaning agents may damage the surface Parts contacting the tape should be checked from time to time for c
9. upply Voltage Battery rechargeable battery mains operation Battery rechargeable battery condition indicator plus recording indicator Lights up when recording Goes out when the batteries rechargeable batteries are weak Recording is still possible until the motor stops sound signal Battery operation with two 1 5V LR6 AA batteries alkaline manganese leak proof Remove batteries from the unit when they are exhausted or if the unit is not to be used for a long period of time No responsibility will be accepted for damage caused by leaking batteries Rechargeable battery operation with recharge able batteries 462 Charge the rechargeable batteries in the unit with the power supply charging unit 679 Charging time approx 22 hours During charging the unit can be used with all functions Battery rechargeable battery compartment Press and hold down the AI LID LOCK button then remove sliding cover from the unit Inserting batteries Ensure correct polarity see figure 2 Inserting rechargeable batteries Observe correct polarity and position Insert the rechargea ble battery with the removed sheathing into the compartment with the lateral charging contact see fig 3 Refit and close sliding cover Mains operation with the power supply charging unit 679 see figure 4 Slide the plug till the end stop into the portable dictation machine Inserted batteries are disconnected the rechargeable batteries 462 is

Download Pdf Manuals

image

Related Search

Related Contents

Guia do usuário do sistema MiSeq - Support    manual leahua  Conditions de Participation et le Règlement  Manuale d`uso del Nokia 6280 - Migros    Manual de Instruções UT325  取扱説明書    OPERATION MANUAL Walk behind power trowels Type  

Copyright © All rights reserved.
Failed to retrieve file