ADDER ADDERView RDX 5000IP
Contents
1. Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le r glement sur le brouillage radio lectrigues publi par le minist re des Communications du Canada ADDER WELCOME CONTENTS INSTALLATION Z S gt 2 aa 2 O FURTHER INFORMATION 13 2011 Adder Technology Limited All trademarks are acknowledged Release 1 0d April 2011 Part No MAN RACKDRAWER ADDER Adder Technology Limited Technology House Trafalgar Way Bar Hill Cambridge CB23 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 ra Seems Www ctxd com TEXTS DOLON Adder Corporation 350R Merrimac Street Newburyport MA 01950 United States of America Tel 1 888 932 3337 Fax 1 888 275 1117 Adder Asia Pacific 6 New Industrial Road Hoe Huat Industrial Building 07 01 Singapore 536199 Tel 65 6288 5767 Fax 65 6284 1150 ADDER WELCOME CONTENTS INSTALLATION Z S gt 2 aa 2 O FURTHER INFORMATION 14
2. Display area 338 x 270mm 17 model or 376 x 301mm 19 model Getting assistance If you are still experiencing problems after checking the list of solutions in the Troubleshooting section then we provide a number of other solutions e Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files e Email support adder com e Fax in the UK 01954 780081 in the US 1 888 275 1117 e Phone in the UK 01954 780044 in the US 1 888 932 3337 ADDER WELCOME CONTENTS INSTALLATION Z S gt 2 aa 2 O FURTHER INFORMATION 11 Safety information For use in dry oil free indoor environments only Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth The unit is heavy Therefore when installing place the rack drawer on a sturdy level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby Both the AdderView RDX Rack Drawer and its power supply generate heat when in operation and will become warm to the touch Do not enclose them or place them locations where air cannot circulate to cool the equipment Do not operate the equipment in ambient temperatures exceeding 35 Celcius 95 Fahrenheit Do not place the products in contact with equipment whose surface temperature exceeds 35 C 95 F Ensure that the power adaptor is mounted so
3. fix the bracket to the rear rack rail e Use one M6 screw and cup washer only in the lower hole of the bracket to fix the bracket to the front rack rail Leave all screws loose until the rack drawer assembly has been put into place 4 FURTHER INFORMATION 7 Tighten all eight M6 screws to complete the installation Connecting the rack drawer All server network and power connections are located at the rear of the unit The EXTernal link network or remote user The single RJ 45 socket labelled as EXT is used to allow either global or remote users to login and control connected servers The EXT port provides one of the following links dependant on the model of rack drawer e An ethernet network link labelled or e A remote extender link to attach an Adder X200 labelled A Note This port is NOT a network port To connect the external link 1 Wherever possible ensure that power is disconnected from the rack drawer 2 Connect a CAT 5 5e or 6 link cable to the port labelled EXT Link cable from either a network connection or a remote extender 3 Connect the other end of the cable as follows e f the EXT port label shows connect the link cable to a network switch router e If the EXT port label shows connect the link cable to an Adder X200 unit Computer access module links There are sixteen RJ 45 sockets labelled as COMPUTER CONNECTIONS on the rear panel Each socket supports a CAT 5 5e or 6 l
4. AdderView RDX Rack Drawer ADpDER User Guide CONTENTS Contents ADDER Welcome Operation Mirodenii aE E eves tunedin sane 2 Opening and closing the rack Crawel ccccccsseseeeeeeeeseeeeneees 8 p e E NAS ING E E E E ETE EE E E EA 3 Operating the rack drawer cccccccsssseeceeeeseeceseeseeeeeeaeseeseaeaes 9 p AddiUonal TEMS spese i meansnd wtaraccennenetiniiaionte 3 Thescoeen CONOIS erre E 9 S Using the OSD MENU vx cancnssacarsesonscranssner krani Err ien NENESE EET RNE 9 Installation Selecting server channels ccccccccsccccsessssecseseeeseseeseseeeeenens 10 Suitable mounting IO CANONS wiixinwscixincdaidansxriewesssnandeianiesdandunsmnness 4 5 Mounting the rack draWefr s esesssseesenenereennrnsrnererinrernnrerrnrnrrerene 4 Further information z Connecting the rack drawer cccccssseeeeceeseeeeceeseeeeseaeeeeeenaaes 5 a sstesterssntoncecissndurce ses cunduniesnrepenntansnmnedthseesentienessrsat 11 s The EXTernal link network or remote user 5 Sereen specificatiONS aeaii 11 Computer access module links sssececcessseeeeeeseeeeeeeeeeess 5 Genna osin ane A 11 Power Connection act pacar tras sietnininsctneeniasonslnesiatch a uated daweimanxtadscetuaains 6 WEE OI a ANEA NEN ENAA A E peste 12 6 miualcon noura liOn een emeee meen a ee meee E eee 7 Safety information ascsiccsitsssecaton satsswtsinsadsednnsdaientabaninernaoetaurstineccsaiaes 12 Radio frequency energy sina cassiaciicr
5. dder user guide as appropriate to the rack drawer model being used e RDxx16yy gt use AdderView CATx 1000 user guide e RDxx16lPyy gt use AdderView CATxIP 1000 user guide e RDxx16QIPyy gt use AdderView CATxIP 5000 user guide where xx is either 17 or 19 denoting the LCD screen size yy is the country code e g UK US etc ADDER WELCOME CONTENTS Z E i r 7p OPERATION FURTHER INFORMATION 10 Further information Troubleshooting Interference signal appears on the screen when shutting down the system e In rare cases interference may appear on the screen This may be caused by Signal rate of the video card and is considered normal The image quality can be improved by adjusting the phase or pixel rate The membrane power light is not ON e Press the Power On Off button on display membrane to check whether the monitor is switched on e Check the power cord is properly connected to the rack drawer and power outlet Screen image is not centered or sized properly e Press the button for five seconds to automatically adjust the image Auto adjust can also be initiated within the geometry section of the OSD menu e Adjust the H position and V position settings via the OSD menu Screen specifications The following specifications apply to both screen sizes unless indicated otherwise Maximum resolution 1280x 1024 Brightness 300 Cd m Contrast ratio 1000 1 Viewing angle 160 x 160
6. directly trom the use of this product Adder s total liability under the terms of this warranty shall in all circumstances be limited to the replacement value of this product If any difficulty is experienced in the installation or use of this product that you are unable to resolve please contact your supplier A ADDER WELCOME CONTENTS INSTALLATION Z S gt 2 aa 2 O FURTHER INFORMATION 12 Radio frequency energy All interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission regulations and ensure a Suitably high level of immunity to electromagnetic disturbances European EMC directive 89 336 EEC This equipment has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in the European standard EN55022 These limits are designed to provide reasonable protection against harmful interference This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception However there is no guarantee that harmful interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to correct the interference with one or mo
7. e Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock ADDER WELCOME CONTENTS INSTALLATION Z z 2 z 5 3 O FURTHER INFORMATION Operating the rack drawer The screen controls Using the OSD menu acme The screen controls are located at the base of the screen Press the M button to display the OSD menu Ver G56SN20SSTD701 1024 x 768 59 8Hz i Image 5 fle Brightness z S Contrast Color Temp Red i LD Green z 5 Blue 3 Select 4 Set E The various sections within the menu are as follows 3 z Image z Controls for brightness contrast colour temp red 2 green and blue Power indicator Geometry green on orange power saving mode Controls for auto adjust H position V position Z O hase and clock z Power button for the screen p 5 as Not used z M Display the OSD menu z DIVES Scroll buttons to control OSD menus Z To auto adjust screen press and hold K for 5 seconds MorUZER e st screen p F mN Exit the OSD menu 2 Also used to toggle digital DVI D and analog SVGA inputs Misc Z Controls tor language OSD position graphic mode OSD time ratio reset and timer where appropriate Selecting server channels In operation you can select server channels in two main ways including e On screen menu or e Keyboard hotkeys For more information please refer to the Operation section of the appropriate A
8. ink to an individual server system Note The maximum length of the CAM cable can be up to 10 metres 32 feet For models RD1716 and RD1916 also ensure that the overall distance between a remote user connected to a remote extender and any CAM unit server does not exceed 300 metres 980 feet 1 Wherever possible ensure that power is disconnected from the rack drawer 2 Connect a CAT 5 5e or 6 link cable to one of the COMPUTER CONNECTIONS ports Link cable to a Computer Access Module 3 Connect the other end of the cable to the Computer Access Module CAM that is linked to the required server system For more information about connecting CAMs please refer to the appropriate Adder user guide as appropriate to the rack drawer model being used e RDxx16yy gt use AdderView CATx 1000 user guide e RDxx16lPyy gt use AdderView CATxIP 1000 user guide e RDxx16QI Pyy gt use AdderView CATxIP 5000 user guide where xx is either 17 or 19 denoting the LCD screen size yy is the country code e g UK US etc 4 Repeat steps 2 and 3 for each server system ADDER WELCOME CONTENTS INSTALLATION Z S p 2 a z e FURTHER INFORMATION Power connection The rack drawer is provided with a power adapter capable of supplying the display monitor keyboard and in built KVM module ADDER IMPORTANT You must only use the manufacturer approved power adapter with the rack drawer IMPORTANT Due t
9. nections to each server Options port Used for firmware upgrades ol ae 16 15 14 13 8 7 6 5 4 3 2 1 12 11 10 9 tass COMPUTER CONNECTIONS 253 COMPUTER CONNECTIONS Power Network or remote extender port input Function is determined by the socket model of KVM module The green indicator is on when power is applied The amber indicator is reserved for future use Reserved ADDER WELCOME CONTENTS INSTALLATION Z z p 2 a z O FURTHER INFORMATION Standard items Additional items ADDER AdderView RDX Rack Drawer assembly CONTENTS Computer Access Modules One required per connected computer There are four different formats depending on the required computer connections PS 2 style Connectors Analog video PS 2 style keyboard and PS 2 style mouse Part number CATX PS2 USB Connectors Analog video and USB keyboard mouse Part number CATX USB Sun Connectors Analog video Sun keyboard mouse and 3 5mm audio jack Part number CATX SUNA Console CAM for RD1716QIP and RD1916QIP only Connectors D Sub 9 way female Part number CATX CONSOLE WELCOME Z z E i r z i Left and right mounting brackets OPERATION Z nE T lt mf P 8 x screws 8 x cup M6 x 15mm washers cage nuts Installation ADDER Suitable mounting locations e It is very imp
10. o the length of the power cable if the rack drawer Is mounted high in the rack it may not be possible to place the power adapter at floor level In this case it is important to mount it securely and in such a manner that it is not suspended from its output cable CONTENTS To connect the power adapter To disconnect the power adapter 1 Attach the output lead from the power adapter to the 12v socket on the When removing the power connection be aware that the plug has a locking rear panel of the rack drawer mechanism to prevent accidental disconnects To remove pull back the flat top segment of the plug body to disengage the lock and gently pull the whole plug trom the power socket WELCOME Connecting the power adapter to the rear panel power socket Disconnecting the power adapter INSTALLATION 2 Connect the IEC connector of the supplied country specific power lead to the socket of the power adapter 3 Connect the power cord to a nearby power outlet Note Both the rack drawer and the power adapter generate heat when in operation and will become warm to the touch Do not enclose them or place them in locations where air cannot circulate to cool the equipment Do not operate the equipment in ambient temperatures exceeding 35 C Do not place the products in contact with equipment whose surface temperature exceeds 35 C Z z p 2 za z O FURTHER INFORMATION Initial configuration The precise details for c
11. onfiguration of the rack drawer will depend on the model being used For more information please refer to the Configuration section of the appropriate Adder user guide as appropriate to the rack drawer model being used e RDxx16yy gt use AdderView CATx 1000 user guide e RDxx16lPyy gt use AdderView CATxIP 1000 user guide e RDxx16QIPyy gt use AdderView CATxIP 5000 user guide where xx is either 17 or 19 denoting the LCD screen size yy is the country code e g UK US etc ADDER WELCOME CONTENTS INSTALLATION Z z p 2 za z O FURTHER INFORMATION Operation Opening and closing the rack drawer The compact rack drawer is easy to open and close when required To open the rack drawer To close the rack drawer 1 Press the button on the carry handle at the front of the rack drawer unit and 1 Fold down the screen and locate the black arrow release button on each gently pull the carry handle towards you side of the drawer slider 2 Pull forward and hold the two black arrow buttons while slightly pushing the drawer slider in to release the locks 2 Once the drawer is fully extended lift up the carry handle to reveal the 3 Gently push the drawer slider all the way into the rack using the carry screen and keyboard handle Take care to keep your fingers away from the sliders x 3 Note for safe use e Keep all liquids away from the equipment to minimise the risk of accidental spillag
12. ortant to locate the AdderView RDX Rack Drawer in a suitable 3 Insert the rack drawer assembly into the mounting brackets environment e The surtace for placing and fixing the rack drawer should be stable and level or mounted into a suitable cabinet e Make sure the place has good ventilation is out of direct sunlight away from sources of excessive dust dirt heat water moisture and vibration CONTENTS e Position the rack drawer with respect to related facilities Mounting the rack drawer 1 Determine the appropriate position for the rack drawer within your rack frame Insert two of the supplied cage nuts in each of the rear vertical rack rails and one cage nut in the lower position of each front rack rail WELCOME Black arrow button A The unit is heavy Ua aa 4 Pull and hold the left and right black arrow buttons on the rails s erakin 5 Return the LCD keyboard drawer to park position 2 on a sturdy level 6 Use the remaining two M6 screws and cup washers to fix the front B surface to prevent mounting ears of the rack drawer assembly to rack rails it from accidentally falling and causing damage to other equipment or injury to persons nearby OPERATION Left front 2 Attach the supplied left and right mounting brackets to the positions in your rack frame where the cage nuts are located and adjust the bracket depths to suit the depth of the rack For each mounting bracket e Use two M6 screws and cup washers to
13. re of the following measures a Reorient or relocate the receiving antenna b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different trom that to which the receiver is connected d Consult the supplier or an experienced radio TV technician for help FCC compliance statement United States This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in Subpart J of part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Canadian department of communications RFI statement This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications
14. rin staswnoerserelasedinncensemtonagtinks 13 x Z Z z p 2 za z O FURTHER INFORMATION Welcome Introduction Thank you for choosing the AdderView RDX Rack Drawer which combines screen keyboard mouse and sixteen port KVM switching while occupying only a single rack slot The screen and keyboard slide out to provide quick access to all systems when working in the server room All models also facilitate either remote or global access for authorised users who are away from the server room All KVM links to servers are made using Adder Computer Access Modules CAMs that attach to the rack drawer rear panel via standard CATx cables These make installation straightforward while ensuring that all cabling remains neat and uncluttered Carry handle to release the two point lock Clear LCD display screen Display control panel Keyboard and mouse touchpad KVM switch with connections at the rear Switch for screen auto power off Certain sections of this manual refer to other Adder user guides for details about the KVM module fitted within your rack drawer These other guides are stored on the CD ROM supplied with your rack drawer and are also available on the Adder website Config switches Reserved for future use ensure that both are in the up off position Computer Connection ports 16 ports to which CAT 5 5e or 6 link cables are used to connect Computer Access Modules CAMs which provide the con
15. that neither its cables nor connectors are stressed Observe all precautions and warnings attached to the equipment Warning live parts contained within power adapter No user serviceable parts within power adapter do not dismantle Plug the power adapter into a socket outlet close to the rack drawer Replace the power adapter with a manufacturer approved type only Do not use the power adapter if the power adapter case becomes damaged cracked or broken or if you suspect that it is not operating properly Do not attempt to service the unit yourself Not suitable for use in hazardous or explosive environments or next to highly flammable materials If you use a power extension cable make sure the total ampere rating of the devices plugged into the extension cable do not exceed the cable s ampere rating Also make sure that the total ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet s ampere rating Warranty Adder Technology Ltd warrants that this product shall be free from defects in workmanship and materials for a period of two years from the date of original purchase If the product should fail to operate correctly in normal use during the warranty period Adder will replace or repair it free of charge No liability can be accepted tor damage due to misuse or circumstances outside Adder s control Also Adder will not be responsible for any loss damage or injury arising directly or in