Home
HoMedics USL-1000-EU
Contents
1. Assembly First remove all components from the box and unwrap from the protective polybags 1 Take the applicator storage bracket and fix to the back of the main unit by locating the two pins into the holes on the unit and pushing firmly downwards to lock into place fig 2 0 2 Connect the ultrasonic applicator to the main unit taking the metal connector for the applicator and insert into the socket on right side of the main unit fig 2 1 Ensure that the plug is the correct way up To store the applicator ready for use place into the storage bracket with the metal plate facing upwards fig 2 2 a q awi b A Fig 2 0 Fig 2 1 Fig 2 2 3 Take the povver cord and connect to the socket on the machine Plug the unit into the mains to protect the device vve recommend using a surge protected socket The device is novv ready to use IMPORTANT PLEASE READ PRECAUTIONS ON PAGE 4 BEFORE USE Before Beginning Your Treatment For best results it is highly recommended to increase your hydration levels by drinking up to 2 litres of vvater in the two hours before use This will increase your body s ability to process the metabolise fats released during treatment vvithin the liver and effectively flush it from the body t is essential that the product is used in conjunction with HoMedics UltraSlim Pro Gel The gel helps to conduct the ultrasound waves into the body Without the gel the device will not function corr
2. 2
3. Excessive heating can occur and cause fire electrocution or injury to persons DO NOT carry this appliance by the cord or use cord as a handle DO NOT use outdoors This product requires a 220 240 V AC power supply DO NOT attempt to repair the appliance There are no user serviceable parts For service send to a HoMedics Service Centre All servicing of this appliance must be performed by authorised HoMedics service personnel only Never block the air openings of the appliance or place it on a soft surface such as a bed or couch Keep air openings free of lint hair etc Do not place or store appliance where it can fall or be pulled into a bath or sink Do not place in or drop into water or other liquid Failure to follow the above may result in the risk of fire or injury Burns can result from improper use Never use accessories that are not recommended by the manufacturer SAFETY CAUTIONS PLEASE READ THIS SECTION CAREFULLY BEFORE USING THE APPLIANCE It is advisable to consult your doctor before using this product in particular if you suffer with any pre existing health conditions see below It is not recommended for treatment of those under the age of 18 Keep this appliance out of the reach of children Do not use for longer than the recommended time It is not recommended to use this device if you suffer from any of the following conditions If you are pregnant or think you might be e Ifyou a
4. HOMEDICS UltraSlim Pro iy nstruction Manual USL 1000 EU year guarantee Thank you for purchasing HoMedics UltraSlim Pro UltraSlim Pro is an innovative device using salon technology for use in the comfort of your own home It improves body shape by reducing body circumference measurements and treats unwanted fatty deposits under the surface of the skin that cause cellulite We strongly recommend that you read this User Manual thoroughly before use to ensure you use the product effectively and safely NB Best results are achieved when UltraSlim Pro is used in conjunction with a healthy diet and regular exercise Top Tips For Safe And Succesful Treatments Drink plenty of water to help the body process and remove resulting toxins from the body It is recommended to perform treatment during the morning as this provides more time for your body to process the fats released Perform 20 30 mins of light exercise after the treatment to stimulate lymph movement Total treatment times should never exceed 40 mins in a single 24 hour period Maximum treatment time for a single area is 20 mins e g one thigh or abdomen area Always leave at least 72 hours between treatments Avoid alcohol and caffeine for 48 hours whilst the body processes toxins released during treatment Please refer to page 6 before treatment this section outline what to expect during treatment For more information about UltraSlim Pro including a demo video visit us a
5. a beep and enter standby mode To reactivate press to recall the session and to continue treatment Once the timer reaches zero the treatment will stop and the unit will emit a double beep Customising your treatments The preset time and intensity levels take into account the amount and depth of fat normally located in the specific treatment areas and are therefore recommended for normal use The table below provides guidelines for the pre set treatment times levels Treatment area Pre set time Power level Abdomen lower back 15 mins 4 Thighs Legs 10 mins 3 Buttocks 12 mins 4 Upper arm 8 mins 3 If you find the treatment uncomfortable buzzing noise or pins and needles you may wish to reduce the intesity duration Increasing the intensity or duration of treatment from the preset will have a greater impact on fat cells but the pins and needles sensation and the buzzing noise will be greater To change treatment time from the preset use the arrows Range 1 20 minutes oo To change intensity level from the preset use the arrovvs Range 1 5 o N B Never exceed the recommended treatment times Treatment guidelines for optimum use Key things to remember Never apply USL 1000 EU to the navel breasts the thorax area genitals knee joints lower leg elbow forearm wrists or hands as this will cause discomfort Ensure you have liberally applied UltraSlim Pro gel For best results it is recommended to combine diff
6. before cleaning To disconnect turn all controls to the OFF position then remove plug from outlet NEVER leave an appliance unattended when plugged in Unplug from the mains outlet when not in use and before putting on or taking off parts or attachments This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance DO NOT reach for an appliance that has fallen in water or other liquids Switch off at the mains and unplug it immediately Keep dry DO NOT operate in wet or moist conditions NEVER insert pins or other metallic fasteners into the appliance Use this appliance for the intended use as described in this booklet DO NOT use attachments not recommended by HoMedics NEVER operate the appliance if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return it to the HoMedics Service Centre for examination and repair Keep cord away from heated surfaces NEVER drop or insert any object into any opening DO NOT operate where aerosol spray products are being used or where oxygen is being administered DO NOT operate under a blanket or pillow
7. ectly and the ultrasound applicator may be damaged Ensure the treatment area is clean and dry and remove any items of clothing covering the skin in the area to be treated Before commencing treatment apply the UltraSlim Pro Gel liberally to the treatment area What to expect during treatment 1 It is normal to experience a buzzing noise in the ears as the operating frequency is close to the lowest frequency audible by the human ear This will not damage the ear but may cause some discomfort Be mindful if using the device around animals with sensitive hearing NB In areas with less fat the noise is louder Additionally treatment areas that are closer to the ears e g arms will result in a louder buzzing noise than areas further from the ears e g thighs The sound should stop when treatment is finished 2 You will feel a sensation similar to pins and needles as the fat cells become impacted by the treatment This is perfectly normal and indicates the device is successfully treating the fat cells 3 The metal plate on the handle will become warm during use especially if used for 30 40 minutes If you are sensitive to heat you may wish to stop using the device until the handset cools down 4 Some users experience a reddening of the skin during use which can remain for up to 2 hours after use 5 Very occasionally mild side effects may occur such as excessive thirst or nausea immediately after the treatment This can be resolved by drinkin
8. erent massage techniques spiral crossways circular during different sessions Slide the handset slowly over the skin without pressing ensuring an even contact between the metal surface and the skin a a 2 e bag im om Abdomen Lower back Sides Circular and longitudinal massage movements should be applied from top to bottom as shown in the diagrams Combine the various massage techniques during different sessions Thighs Hips Circular and longitudinal massage movements should be applied from the bottom upward as shown in the diagrams During treatment concentrate on the area with the most fat Buttocks Longitudinal and circular massage should be done in the direction of the arrows shown in the diagrams Arms Massaging this area should be applied toward the body as shown in the diagram 10 After Treatment Care After you have finished your treatment clean any gel from the handset using a damp but not wet cloth Return the handle to the cradle Switch off the unit using the switch at the back of the machine and unplug from the mains Remove any excess gel from the skin with a damp cloth If you wish to apply anti cellulite or toning creams gels after treatment is a good time to do this For best results it is recommended to take 20 30 minutes of light exercise e g walking cycling swimming etc to assist with drainage of the lymphatic system Ultrasound Re Calibration Process To prolong t
9. g water NB If you feel excessive discomfort due to noise or other sensations during treatment it is possible to manually adjust the intensity see page 8 and 9 Treatment Zones And Areas To Avoid EN gt 1 Areas to avoid Safe treatment zones 4 4 FRONT BACK Maximum Recommended Treatment Frequency And Duration Recommended Treatment Schedule For correct and safe usage please follow the below guidelines Per Treatment Zone 20 minutes maximum per session Treatment Zone refers to the area of the body selected for treatment Example It is OK to treat the abdomen for 15 minutes and then the thighs for 15 minutes but NEVER perform a 30 minute application on only your abdomen in the same day Each upper leg or arm should be considered a separate treatment area Per Session 40 minutes maximum per treatment session Session refers to the total treatment time in one day NEVER exceed 40 minutes per session Example This could be 20 minutes over 2 Treatment Areas or 10 minutes over 4 Treatment Areas for example Between Sessions Minimum 72 hours It is important to leave at least 72 hours between sessions to allow the body to eliminate all the fat released during the session It is OK to leave a slightly longer time between treatments but a gap of more than one week for a particular treatment area may reduce the efficacy Example in one week the MAXIMUM Schedule would be Monday Thursday Sunday It is recommended to re
10. he life of the unit it is necessary to periodically re calibrate the frequency This ensures that the applicator and main unit are operating at the same frequency to deliver the best treatment results It is recommended to carry out this process at least every 100 working hours but it does not matter how often you check the calibration If the tingling sensation felt during use reduces in intensity over time this may indicate that the unit requires recalibration Calibration process 1 To enter calibration mode first turn the unit on Select a treatment mode and press Di activate the ultrasound Press and hold both up and down arrows Level o The frequency will display on the screen 2 The frequency should be set to 40 to maximise the performance of the device Use oo to change the frequency if it is above or belovv 40 3 After changing the frequency press to save the changes If freguency is already at 40 go to the next step 4 Press oo together to exit the frequency calibration interface then the device will go to the standby status Measurement Chart Use the below table to keep track of your treatments and record circumference reduction Either complete the table on this page or photocopy Treatment Treatment Area Circumference Notes Measurement Date 11 HOMEDICS Register your product today at http www homedicsgroup com register IB USL 1000EU 0413 0
11. re breast feeding Undergoing fertility treatments If you have any kind of heart disease Ifyou suffer from skin problems Osteoporosis Fibromyalgia Malignant tumours Hypertension High cholesterol levels kidney problems Metal implants or prostheses Hearing implants Physical deformity Epilepsy Long term treatment with medications anti inflammatories anticoagulants antibiotics or antihistamines Depression Psychiatric or psychological treatment Liver problems fatty liver Irritable bowel syndrome Diabetes Avoid using the device to treat areas where the bone is close to the skin and there is very little fat as this can cause discomfort Under no circumstances should the USL 1000 EU be used on head neck breasts the thorax navel forearm joints genitals back or lymph glands see diagram on page 7 treatment of these areas is likely to cause discomfort and this is not where fat deposits are located Avoid passing the handset over tattooed areas This appliance should NEVER be used by any individual suffering from any physical ailment that would limit the user s capacity to operate the controls NEVER use directly on swollen or inflamed areas or skin eruptions DO NOT use on an infant invalid or on a sleeping or unconscious person DO NOT use on insensitive skin or on a person with poor blood circulation Upon opening the UltraSlimPro package you will find the following part
12. s UltraSlim Pro device Ultrasonic Applicator Electrical power cords 1 x UK 1 x EU UltraSlim Pro gel 500ml Applicator storage bracket assembly required User manual Warranty card Additional accessories sold separately UltraSlim Pro Gel 500ml i S Plug Model USL1000 GB ONLY yi If the plug on this appliance is damaged it can be replaced with a BS 1363 plug H N ODE fitted with a 3A BS 1362 fuse Only use a 3amp fuse with this appliance Care must 5 be taken vvhen changing the plug If in doubt contact a qualified electrician D RE Battery directive This symbol indicates that batteries must not be disposed of in the domestic waste as they contain K substances which can be damaging to the environment and health Please dispose of batteries in designated collection points WEEE explanation This marking indicates that this product should not be disposed with other household wastes x throughout the EU To prevent possible harm to the environment or human health from uncontrolled mm waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling 5 ASSEMBLY AND PREPARATION FOR USE
13. st from treatment for 3 weeks after 20 sessions Once you reach your target it is recommended to carry out approximately 2 maintenance sessions per month although this may vary according to the individual USING YOUR ULTRASLIM PRO UltraSlim Pro Control Panel and Functions Treatment zone Indicators MODE Select preset treatment zone ultraslim i a Start Pause treatment Timer Display 60 6 Intensity Display Level Increase or decrease Increase or decrease treatment time intensity level Beginning a treatment session Once you have plugged the machine into the mains supply and turned on the power switch reverse of unit the following default settings will appear on the monitor Treatment Zone Abdomen Time 15 minutes Intensity Level 4 To scroll through the different treatment zone press The LED for the selected zone will illuminate N B The treatment zone cannot be changed once treatment starts With the required Treatment Zone Level and Time selected you are ready to begin First ensure sufficient gel has been applied to the treatment area remove the Ultrasound applicator from the bracket and press to start treatment With the metal surface of the Ultrasound applicator massage the area using the techniques shown on the next page To pause treatment press and simply press again to restart the treatment If the session is not restarted within 5 minutes the device will emit
14. t www homedics co uk Benefits How Does Ultrasonic Slimming Work Ultrasonic slimming works by delivering a low frequency Ultrasound 40Khz to a targeted area of the body This specific wavelength of ultrasound causes the fat cell membrane to vibrate and subsequently breakdown The body then processes the released triglycerides fatty acids by either converting it to energy or metabolising via the liver for disposal Benefits UltraSlim Pro provides the following benefits UltraSlim Pro is a salon grade device that can effectively treat the unwanted localised build up of fat cells including cellulite in the body The treatment is non invasive and provides a more attractive alternative to cosmetic surgery with no recovery time required Features Pre set treatments the product includes four preset treatment modes 1 Abdomen including fatty deposits at the sides of the lower back 2 Thighs upper leg 3 Hips buttocks 4 Arms Fully Programmable it is also possible to manually override according to personal preference 1 Treatment Time from 1 to 20 minutes 2 Treatment Intensity Levels 1 5 READ ALL INSTRUCTIONS BEFORE USE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL PRODUCTS ESPECIALLY WHEN CHILDREN ARE PRESENT BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING ALWAYS unplug the appliance from the electrical outlet immediately after using and