Home
Draper Ultimate Access/Series V
Contents
1. Suitable for use in environmental air space in accordance with Section 300 22 c of the National Electrical Code and Sections 2 128 12 010 3 and 12 100 of the Canadian Electrical Code Part 1 CSA C22 1 If you encounter any difficulties installing or servicing your Ultimate Access screen call your dealer or Draper Inc in Spiceland Indiana 765 987 7999 or fax 765 987 7142 Ultimate Access Series E amp V by Draper Motorized Roller Fabric Installation The bottom access panel trap door assembly must first be opened and placed in fully opened position The motor end mounting bracket has a metal bracket with snap ring for accepting motor head Back out the four set screws in bracket until they are flush with top side of bracket To engage the motor end bracket flange above the two channels in the top of the screen housing rotate the bracket approximately 45 counterclockwise to allow the top surface of the motor bracket to rest flat against the top inside of the housing Rotating the bracket clockwise until it is engaged with the channels slide it along the length of the housing against the electrical junction box Engage the idler end bracket rectangular mounting pad in the same manner as the motor end bracket and slide it toward the opposite end of the screen housing Do not tighten the set screws on the brackets until the roller fabric assembly is installed and centered in the case Locate the black washer and retainin
2. T Jacketed Motor Cable 5 Fa x L o s S g ml Wire connected with Quick Disconnect i i i i Built In LVC III Field Wiring J Box Normally on Audience Left 10 Ring Terminal on Ground Wire Riveted to J Box LVC III J Box Normally on Audience Right Strain Relief Bushing Draper P N C034 002 Green Green HEYCO 6N3 4 1 Per J Box White Brown Down A Red Up 5 Black Black Black 120V AC LVC3 Module 2 Black 0 i Z Jacketed Cable es 3 5 5 Draper P N C115 001 ER gooo Green Wire not Used Screen Motor Socket LVC S 24V DC Wall Switch Door Motor Socket 10 Ring Terminal on Ground Wire Riveted to J Box Page 4 of 4 Door Motor Socket Socket Screen Motor Field Wiring J Box Audience Left Location amp Orientation of Motor Sockets on J Box Screen Motor Plug Door Motor Plug 0o00 000o aala RE LLEE zj S z A UP Reap Es 22 E E 2 5g Stop kirn 8 z 8 83 8 868 3 Crimp on Wirenut by Draper White Com 9 re i sc 295 9 55 oO Wirenut by others 7 Down Kk 4 2388 8a Wiring by others Black Down D o a 120V AC Screen Motor 120V A
3. points apply Mounting brackets are packed separately in carton Engage each bracket with top of housing as shown below and tighten set screws Bracket should be within 8 from each end of screen case Brackets can be removed and case mounted with lag screws through top of case holes drilled on site Screen should be positively and securely supported so that vibration or even abusive pulling on viewing surface will not weaken installation Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen Entire bottom of case must be readily accessible after installation is complete The bottom access panel trap door and lower edge of the case are joined with continuous hinge joints and must operate freely Front and back of case must be straight not forced to warp or bow Hinge joints must be free of mastic or paint build up and trapdoor and access panel must be unobstructed by ceiling tiles If case is painted on location removal of roller fabric assembly is recommended prior to painting If not removed slots on bottom of case Remove shipping brackets before operating screen Slots along top of case permit brackets to be set at an angle Typical Installation Shipping Bracket Alternate Installation additional set of brackets required but not included 411 S Pearl St Spiceland IN 47385 USA I 765 987 7999 www draperinc com
4. After screen case has been mounted remove the dowel shipping brackets from dowel if provided A spring latch at each end of the trap door holds this assembly closed In some screens there will also be a spring latch near the center of the case To gain access to inside of screen case disengage spring latch at each end of the case and near the center of the case if applicable by sliding the latch lever towards the center of screen case then pull down slightly on the trap door assembly The latch levers are somewhat concealed from view Locate these with the trap door open by feeling for the vertical latch lever above the door about 3 from case endcaps and near the center of the case The assembly will swing down opening about 135 Pivot the prop arms at each end of the trap door assembly towards the ends of screen case Prop arms engage with a hole in each endcap to hold the trap door assembly fully open To close the trap door assembly disengage prop arms from endcaps and pivot these over the access panel Swing the trap door assembly upward stopping just before the latch levers hit the bottom flanges of the endcaps and center of case where appropriate Pull levers of latches towards center of screen case to allow the trap door assembly to be pivoted to its closed 2 position Make sure that the spring latch levers engage fully with case endcaps and center of case where appropriate Caution Beware of pinch points along closure
5. C Door Motor www draperinc com DRAPER 765 987 7999 Optional Radio Receiver or IR Sensor
6. I fax 765 987 7142 Copyright 2013 Draper Inc Form UltimateAccess_Inst13 Printed in U S A US Patent Nos 5 341 241 6 137 629 6 421 175 6 532 109 6 816 308 7 559 707 should be shielded to protect viewing surface from paint splatters or overspray Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully Electrical Connections Screen operates on 110 120V 60 Hz 1 1 amp current draw Junction box is located just above the bottom access panel at the left end of the screen Open the access panel trap door for access to the junction box cover See bottom access panel trap door opening and closing instructions below Remove two 2 hex head screws that secure the cover to the junction box to expose the red black and white pigtail leads and the green ground wire per wiring diagram on page 3 If optional low voltage control or video interface control is specified and factory installed please refer to wiring diagrams on page 4 Screen is shipped with internal wiring complete and control switch es fully boxed Wire to connect screen to switch es and switch es to power supply should be furnished by installer Connections should be made in accordance with attached wiring diagram and wiring should comply with national and local electrical codes All operating switches should be off before power is connected Bottom Access Panel Trap Door Opening amp Closing
7. Installation Operating Instructions Ultimate Access Series E amp V Electric Projection Screen by Draper A Caution Read instructions through completely before proceeding Follow instructions carefully Installation contrary to instructions invalidates warranty Entire bottom of screen case should be unobstructed to permit access to bottom panel for electrical connections or servicing Screen should be installed level using a carpenter s level Nothing should be fastened to screen dowel or viewing surface Operating switch es and mounting brackets are packed separately in screen carton Do not discard with packing material Screen operates on 110 120V 60 Hz AC 1 1 amp current draw NOTE Screen has been thoroughly inspected and tesied at factory and found to be operating properly prior to shipment These instructions are meant as a guide only They do not imply any responsibility on the part of the manufacturer for improper installation or faulty workmanship at the jobsite Hanging Screen When locating viewing surface and checking clearance for screen s operation remember surface is centered in the length of the case Screen is normally recessed above ceiling with the motor on the left as the audience sees the screen For reverse roll screens install headbox with motor on the right See typical installations detailed on page 3 of this sheet Regardless of mounting method used the following
8. e Port for IR Eye For RF Receiver or LED Two Way Serial Communication RS232 with MC1 Internal Screen Wiring White Common Red Up Black Down Green Yellow Gnd of 1 1 1 1 AREE Line ver Location of key operated on off switch if furnished fg Control Switches 24v DC See separate Serial Communication RS232 Instruction sheet for enabling RS232 with the MC1 www draperinc com DRAPER 765 987 7999 Ultimate Access Series E amp V by Draper Wiring Diagrams with Built In Controls Built In VIC 12 12 Volt VIC 12 or 6 Volt VIC 6 Relay L _ Ring Terminal on ground wire riveted to J Box with Star Washer Green 2 2 Green Ground Red i Red oja 2Up 110 120 VAC olg Black _l 4 Down Screen Motor z Black 2 2 i 3 x White Common oO Z K Jacketed Motor Cable D f g D c Wire soldered to terminal Wire connected with Quick Disconnect Built In VIC 115 115 Volt Relay LL L Ring Terminal on each Ground Wire with Star Washer screwed to Spine BE EZ Green Green 6cor ed o 9 Bad Ground 4S ed O a e 2Up 110 120 VAC 2 sax 2 2 Black 1 Down Screen Motor z tyr White _ Common D 8
9. ed from the switch in either on or off position A three position key switch permits screen to be operated directly by key In this case the screen s operator must always have a key RS232 Ethernet Serial communication and network communication optionally available with wall switches RF or IR remote Limit Adjustments Please Note Screen limits are factory set for optimum performance of the screen A procedure is outlined below for minor tweaks but any adjustment of these limits may negatively affect the flatness of the screen surface and could also void the warranty Please check with Draper prior to resetting screen limits A CAUTION Always be prepared to shut screen off manually when new adjustment is being tested Screen may be severely damaged if viewing surface is allowed to run too far up or too far down A CAUTION Be sure all switches are in off position before adjusting limit switches i motor limit screws are normally located on the audience left of screen roller DOWN LIMIT ADJUSTMENT To Reduce Screen Drop Raise screen surface about 1 above desired setting and turn off Turn the WHITE DOWN limit screw clockwise three screw turns roller revolution Test by running screen down and repeat steps 1 and 2 until desired position is reached To Increase Screen Drop Run screen to the down limit With the down switch on turn the WHITE DOWN limit screw counter clockwise 3 turns of screw equals r
10. firm satisfactory operation 110 120V SINGLE STATION CONTROL 3 position UP OFF DOWN switch permits operation to be stopped at any point Factory adjusted limit switches automatically stop screen when fully down or fully up 110 120V MULTIPLE STATION CONTROL Switches are similar in appearance to 110 120V Single Station Control Screen stops when switch is released and may be restarted in either direction Factory adjusted limit switches stop screen automatically when fully down or fully up 24V MULTIPLE STATION CONTROL Three button UP STOP DOWN switches stop at any point desired operate in any sequence Factory adjusted limit switches automatically stop screen when fully down or fully up 110 120V amp 12V VIDEO INTERFACE CONTROL Allows screen to be controlled by a trigger signal when signal comes on screen descends Page 2 of 4 automatically Two versions Model VIC 115 integrates screen operation with a DRAPER video projector lift or a video projector or tuner with a 110 120V switched outlet Model VIC 12 interfaces with 12V switched outlet Both available with override switch VIC OS permitting independent operation VIC OS not available with factory installed VIC 115 amp VIC 12 KEY OPERATED SWITCHING Two kinds of key operated switches are optionally available with this unit The key operated power supply switch controls power to screen and switches When it is off the switches will not operate screen Key may be remov
11. g clip Note This will require two people to perform safely Raise the roller fabric assembly up into the screen housing and engage the head of the motor completely into the motor mounting rie bracket making sure the snap ring engages with the motor and that the limit Motor roller Washer switch adjusting knobs are visible from the 4ssembly bottom of the screen housing While supporting the idler end of the roller slide the idler end mounting bracket toward the roller Insert the roller pin into the nylon bushing on the idler end mounting bracket The roller idler pin needs to go through the idler bracket far enough to allow the washer and retaining clip to be reinstalled on the pin Failure to replace the washer and retaining clip as shown could result in the separation of the roller from the brackets The roller fabric assembly and roller brackets may need to be slid left or right in mounting channel of case to center fabric within screen case Securely tighten the set screws on the roller mounting brackets Connect the electrical plug from the motor to the mating socket on the junction box Close the bottom access panel trap door as previously described Idler end roller mounting bracket Motorized Roller Fabric Removal Reverse the instructions above Motorized Roller Fabric Installation for removal of the unit Operation When screen is first operated be cautious Cycle unit down and up several times to con
12. oller revolution to increase drop Test by running screen up about 1 and back down to new down limit Repeat steps 2 and 3 until desired position is reached UP LIMIT ADJUSTMENT Screen is Running Too Far Up Lower screen surface about 1 below desired setting and turn off Turn the YELLOW UP limit screw clockwise three screw turns roller revolution Test by running screen up Repeat steps 1 through 3 until desired position is reached Screen Needs to Run Up More Run screen down about 1 and turn off With the up switch on turn the YELLOW UP limit screw counterclockwise three turns of screw 2 roller revolution Repeat steps 1 and 2 until desired position is reached CAUTION Do NOT allow the dowel to wrap up over the roller when the screen is running up This could damage the screen Tab Tension Adjustment Procedure for Ultimate Access Series V Determine which side requires adjustment Secure dowel with one hand Caution Do not touch or bend surface Using Phillips head screwdriver depress springloaded adjustment screw see drawing and slowly turn clockwise to tighten tension or counterclockwise to loosen tension The screw adjusts in 1 4 turn increments Adjust only one increment 4 turn If problem is not corrected leave screen in position for 24 Powel __ hours to allow surface material to stretch into position If problem still is not corrected repeat steps 2 and 3 Ten
13. shed wiring 1 i Cap off with wire these a splitter is required 1 i E i by electrician TE EE _nut and tape i a Button Wall Switch ra 1 LAR 1L COM White tory Control Single gang box by others k DH t UP Red r i Min 4 x 21 8 x 17 s dee oa l bu i 8 deep i Fen An Port for connecting additional LVC III boi D 1 modules up to six total can be linked n ai connect from Aux to Eye 1 o Red l Black i l Dashed wiring ye i by electrician i l J 1 1 1 1 1 1 To 110 120V Line Single gang box by others Min 4 x 21 s x 17 s deep 1 3 shown More or less equally 1 feasible Black _ H Red to Screen directional Brown to Screen directional gt Black Hot to 110 120V AC F Green Yellow Ground r47 Location of key 1 1 operated on off LY switch if furnished 1 Program LED Fuse ician AC Wiring by eleci RS232 Data FROM Control System S232 Data TO Control Syst Manual Switch Down Manual Switch Up MC1 Wall Switch a Splitter and a Power Supply is required Plug RF Receiver or LED Wall Switch and Power Supply into splitter then run cable from Splitter to MC1 Eye Port White Common to screen amp 110 120V AC Neutral Low Voltage wiring by others _ ri System Signal Ground amp Manual Switch Common Ey
14. sioning Cable Adjustment Screw ie www draperinc com DRAPER 765 987 7999 Ultimate Access Series E amp V by Draper Case Dimensions Mounting brackets slide left and right as needed mm 9 _ gt 10 99 16 Series V Viewing Surface Series E Ceiling tile Viewing Surface by others Series E Series V 83 16 Varies Alternative mounting configuration L Standard Wiring Diagrams Please Note Do not wire motors in parallel Single Station Control Multiple Station Control rin Location of key 1 Operated on off L switch if furnished 1 Page 3 of 4 Low Voltage and Remote Control Internal Screen Wiring White Common Red Up Black Down Green Ground To f o 1i0 120v g ine g n z Location of key operated on of a switch if furnished m Control Switches 24v DC White Common to screen amp 110 120V AC Neutral 5 AR F Red to screen directional Internal Screen Wiring Internal Screen Wiring Brown to screen directional jean E or Sg p Wit Common L eee 1 Black Down Ss a Black Down Green Ground 1 wil lo iggy lt a OO a a a sO Lee T PNE a ES he E EA vf T eS Green Ground De ie ae GreenitGround Eye Port for IR Eye RF Receiver or LED tay i Ul Wall Switch For more than one of ri EN Da
Download Pdf Manuals
Related Search
Related Contents
PEG Manual - Analogue Haven Specifications Genius ColorPage-HR8 LEVISTAGE 専用 オプションパーツ 「WORLD GLOBE」新発売! DE Montage- und Gebrauchsanweisung EN Instruction on mounting Copyright © All rights reserved.
Failed to retrieve file