Home
AMX MSD-701
Contents
1. af EX Overview The Modero S Series is a beautiful touch panel family sophisticated enough for room control yet priced right for the most cost sensitive installations including small huddle spaces and dedicated room scheduling The MSD 701 L 7 Wall Flush Mount Touch Panel FG2265 02 features brilliant 24 bit color depth PoE connectivity and streaming video Sleep Button Microphone Front RJ 45 Micro A B Port USB Port Rear FIG 1 MSD 701 L Product Specifications MSD 701 L Specifications PoE Power over Ethernet 802 3af class 0 Power Consumption Maximum 11W Standby 4 5W Shutdown 1W Startup Inrush Current Not Applicable due to PoE standard Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 140 F 20 C to 60 C Humidity Operating 20 to 85 RH Humidity Storage 5 to 85 RH Power Heat Dissipation 37 5 BTU hr Standby 15 4 BTU hr Operating Environment Dimensions HWD With Back Box 4 88 x 7 40 x 2 30 123 95 mm x 187 96 mm x 58 42 mm Weight e Without Back Box 0 80 lbs 0 22 Kg e With Back Box 1 05 lbs 0 36 Kg UL FCC Part 15 Class B C Tick CISPR 22 Class B CE EN 55022 Class B and EN 55024 CE EN 60950 1 IC CISPR 22 Class B VCCI CISPR 22 Class B RoHS WEEE compliant Included Accessories e MSD 701 L Wall Mounting Template 68 2265 02 Note Optimal performance requires use of one of the following AMX PoE power sup
2. 8 and select OK to access the page Connecting to a Master The panel requires that you establish the type of connection you want to make between it and your Master In the Connection amp Networks page 1 Select Master Connection to open the Master Connection page FIG 4 amp Master Connection FIG 4 Master Connection page 2 Press Mode to toggle through the available connection modes Connection Modes Moge Desorption Procedures Auto The device connects to the first Setting the System Number master that responds 1 Select Master System Number to open This setting requires that you set the keypad the System Number 2 Set your Master System Number and select OK URL The device connects to the Setting the Master IP specific IP of a master viaa TCP 1 Select the Master IP number to the connection keyboard This setting requires that you set the Master s IP 2 Set your Master IP and select OK Confirm device IP is on the Master URL list You can set the Host Name on the device and use it to locate the device on the master Host Name is particularly useful in the DHCP scenario where the IP address can change Listen The device listens for the Master to initiate contact This setting requires you provide the master with the device s IP 3 If you have enabled password security on your Master you need to set the username and password within the device a Select Username to open the Ma
3. ack box The back box FIG 2 is designed to attach the panel to most standard wall and solid surface materials This back box has two locking tabs one on the top and one at the bottom to help lock the back box to the wall These locking tabs are only extended AFTER the back box is inserted into the wall Using the locking tabs is highly recommended for standard mounting surfaces such as walls For thin walls and solid surfaces use 4 mounting screws not included Knockout Locking Tab q MSD 701 L Back Box P Knockout FIG 2 MSD 701 L Back Box Side View WARNING When installing the back box make sure that the assembly is in the correct position and in the correct place Once the locking tabs are extended and locked into place removing the back box may be difficult without having access to the back of the wall or causing damage to the wall Note In order to guarantee a stable installation of the MSD 701 L the thickness of the wall material must be a minimum of 50 inches 1 27cm and a maximum of 875 inches 2 22cm The surface should also be smooth and flat WARNING The maximum recommended torque to screw in the locking tabs on the plastic back box is 5 IN LB 56 N CM Applying excessive torque while tightening the tab screws such as with powered screwdrivers can strip out the locking tabs or damage the plastic back box 1 After ensuring proper placement cut out the mounting surface Use the included
4. essing the Settings Pages To access the Settings Pages on the MSD 701 L press and hold the Sleep Button FIG 1 on the top of the panel for 3 seconds The user will be prompted to release the button to enter the Settings page FIG 3 FIG 3 Settings page Accessing the Configuration Page 1 From the Settings Page select Configuration f the Configuration page is password protected this opens a password keypad 2 Enter the panel password into the keypad the default is 1988 and select OK to access the page Setting the Panel s Device Number and Device Name In the Configuration page 1 Press Panel to open the Panel Configuration page 2 Ensure that the Synchronize Device Names button is not selected and Click it to deselect it if it is Press Device Number to open the Device Number keypad Enter a unique Device Number assignment for the panel and press OK Press the Device Name field to open the Device Name keypad Enter a unique Device Name assignment for the panel and press OK oo Se For full warranty information refer to the AMX Instruction Manual s associated with your Product s 8 13 2013 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX Accessing the Connection amp Networks Page 1 From the Settings Page select Connection amp Networks If the page is password protected this opens a password keypad 2 Enter the panel password into the keypad the default is 198
5. g inserted into the drywall 7 Latch the panel onto the top hooks on the back box and rotate it down Press gently but firmly and evenly on the surface of the glass until the top panel snap clicks to lock it down WARNING if you see a gap between the panel and the back box or feel any binding while locking down the panel stop immediately and verify that no cables or other items are in the way Do not force the panel into position as this can cause damage to the touch screen or the panel electronics 8 Reconnect the terminal Ethernet to its respective locations on either the Ethernet port or NetLinx Master Uninstalling the MSD 701 L In order to access the back of the MSD 701 L such as to install a USB connection for firmware upgrades the device may need to be uninstalled from the back box To uninstall the MSD 701 L 9 From the bottom pull gently outward from the back box Gently rock the panel back and forth to free the bottom from the back box 10 Rotate it up to release the top latch hooks and carefully pull the device free from the back box Take care not to damage or pull the connections on the back of the device Configuring the MSD 701 L The MSD 701 L is equipped with Settings Pages that allow you to set and configure various features on the panel For more information on connecting and configuring the MSD 701 L to a network please refer to the Modero S Series Programming Guide available at www amx com Acc
6. mounting template 68 2265 02 or refer to the dimensions in the MSD T 701 Operation Reference Guide available from www amx com for more information CAUTION Making sure the actual cutout opening is slightly smaller than the provided dimensions is highly recommended This action provides the installer with a margin for error if the opening needs to be expanded Too little wall material removed is always better than too much 2 Remove either the top or the bottom knockout from the back box depending upon the required installation Thread the incoming wiring through the hole in the rear of the back box 3 Thread the incoming Ethernet wiring from their terminal locations through the surface opening and through the access slot 4 Push the back box flat into the mounting surface and secure with either the locking tabs or 4 mounting screws not included In order to prevent damage to the touch panel make sure that any screws used are flush with the back box and the back box goes freely into the opening 5 Insert each connector into its corresponding location along the back of the MSD 701 L 6 Test the incoming wiring by attaching the panel connections to their terminal locations and applying power Verify that the panel is receiving power and functioning properly to prevent repetition of the installation Note Do not disconnect the connectors from the touch panel The unit must be installed with the attached connectors before bein
7. plies not included e PS POE AF TC PoE Injector 802 3AF Compliant FG423 83 e NXA ENET8 2POE Gigabit PoE Ethernet Switch FG2178 63 Note AMX does not support the use of non AMX power supplies Note For more information on installation and configuration as well as complete specifications on this device please refer to the MSD T 701 Operation Reference Guide available at www amx com Certifications Quick Start Guide MSD 701 L 7 Modero S Series Wall Touch Panel Panel Connectors and Wiring FIG 1 shows the connectors located on the back of the MSD 701 L Power for the MSD 701 L via Power Over Ethernet Power for the MSD 701 L is supplied via Power Over Ethernet PoE utilizing an AMx certified PoE injector such as the PS POE AF TC PoE Injector FG423 83 or other approved AMX PoE power source The incoming Ethernet cable should be connected to the RJ 45 port on the MSD 701 L Note The Micro A B USB port is used only for firmware uploads as it is inaccessible when the device is installed within its back box Installing the MSD 701 L The MSD 701 L can be installed either directly into a solid surface environment using either solid surface screws or the included locking tabs for different mounting options For more information please refer to the MSD T 701 Operation Reference Guide available at www amx com Installing the MSD 701 L into a wall The MSD 701 L is contained within a clear outer housing known as the b
8. ster User keyboard b Set your Username and select OK c Select the Password to open the Master Password keyboard d Set your Master Password and select OK e Press the Back button twice to return to the Settings page Configuring the Panel to a Network The first step is to configure the panel s communication parameters This only configures the panel to communicate with a network and it is still necessary to tell the panel with which Master it should be communicating Network Communication With a DHCP Address In the Connection amp Networks page 1 Select Network Connection to open the Network Connection page 2 Toggle the DHCP Static field until the choice cycles to DHCP This action causes all fields on the page other than Host Name to be greyed out 3 Select Host Name to open the Host Name keyboard Enter the new host name and click OK 93 2265 02 REVE AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com BP
Download Pdf Manuals
Related Search
Related Contents
6 Rainbow Mobile Phones with Docking Station USER GUIDE Samsung CP1370EST Manuel de l'utilisateur 1 Indicaciones de seguridad 2 Estructura del mecanismo 3 Función AerPOS User`s Manual CX612 - Busy Bee Tools OS 2.1 - Wikango AMX SP-16-AX-TR-UK XP1000.5 E-SCAN ES610 User's Manual Copyright © All rights reserved.
Failed to retrieve file