1. OPERATING INSTRUCTIONS Please read the instructions carefully before operating the appliance or carrying out maintenance operations Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference V 02 13 GENERAL OPERATING AND SAFETY INSTRUCTIONS This appliance is a highly efficient dehumidifier designed for domestic use only Use this dehumidifier only as outlined in this manual Any other use not recommended by the manufacturer may cause fire electric shock or malfunctions Ensure that the required voltage and frequency 220 240V 50Hz match the available power source Make sure the plug Is inserted fully Do not use multiple adapters Do not touch the plug with wet hands Make sure the plug 5 clean This product is not a toy Children should be adequately supervised to ensure that they do not play with the appliance This appliance is not suitable for use by persons including children with reduced physical sensory or mental abilities or persons without the necessary experience and knowledge unless they have been adequately supervised and instructed concerning the use of the appliance by a person responsible for their safety Disconnect the mains power when the appliance is not in use or during cleaning operations Keeping the appliance plugged in may cause electric shocks or accidents To disconnect the appliance s
2. o ANANA 5606000600006 amp DESCRIPTION OF PARTS 4 5 6 7 FRONT VIEW 1 3 gt 72 LL a 02 13 OPERATING INSTRUCTIONS APPLIANCE STARTUP Place the product on a flat and stable heat resistant surface at least 1 metre away from flammable or heat sensitive materials and 50 cm away from walls or other obstructions Make sure the water tank Is in the correct position Connect the power cord to a suitable electric socket 230V Press the button ON OFF on the control panel The OPERATION LED C which indicates dehumidifier operation will light up OPERATING PRECAUTIONS The dehumidifier adjusts the humidity level automatically and stops working only when the tank Is full and you have not set the continuous condensate drainage In this case empty the tank and reposition correctly the dehumidifier will start running again WARNING After every interruption in operation at least 3 minutes must pass before the dehumidifier s
3. other liquids Do not expose the dehumidifier to direct sunlight Keep the appliance well away from sources of heat which could cause plastic parts to become warped Do not spray insecticides oils or paints near the appliance this could damage the plastic or start fire Keep flammable gases and oils away from the appliance Do not move the appliance during operation as water leakages or malfunctions may result V 02 13 8 1 CONTROL PANEL 2 HANDLES FOR TRANSPORTATION 3 FRONT PANEL 2 LLI O lt 5 A zZz 26 02 1 lt lt q 2 amp lt ac l2 2 2 oc 40 gt T zt Gwe lt A gt 40 qt 8 LLI Or LL gt 05 lt 2 a gt G eW N gt lt UU z 5 Lu 2 lt 2Ou OZ 1 ue O lt lt x wt gt lt st ln l LLJ gt a 2 02 5 e e lt 300000000000 AA O O a ae a a LL ONS Sw IONS et ae
4. an the exterior surface of the dehumidifier Do not use solvents petrol xylene talcum powder or brushes these products may damage the surface or alter the casing colour CLEANING THE AIR FILTER The filter is designed to remove dust or dirt from the air If the filter is clogged by dust electricity consumption will be higher than normal To optimise humidity removal efficiency clean the filter once a fortnight Cleaning instructions 1 Remove the tank grip the lower part of the filter and pull downwards to remove it completely 2 Clean the filter Using a vacuum cleaner or wash it with clean water at a temperature below 40 C DO NOT USE ALCOHOL BENZENE OR OTHER AGGRESSIVE PRODUCTS 3 Leave the filter to dry naturally then reposition it in the relevant slot V 02 13 1 TECHNICAL DATA MODEL DEOLO BABY 11 POWER SUPPLY VOLTAGE 220 240V 50 Hz 11 L 24h MOISTURE 32 C 80 RH REMOVAL 10 L 24h 30 C 80 RH 250 W DIMENSIONS Height Width Depth mm WEIGHT Kg 10 1 417x312x235 OPERATING LIMITS 5 C 32 C F GAS REGULATION EC no 842 2006 Do not release R 134a into the atmosphere R 134a is a fluorinated greenhouse gas covered by the Kyoto protocol with a global warming potential GWP of 1300 INFORMATION ON PROPER DISPOSAL OF THE APPLIANCE IN COMPLIANCE WITH EUROPEAN DIRECTIVE 2002 96 EC When this appliance reaches the end of its useful life it must b
5. e disposed of together with household waste but must be delivered to appropriate separate waste disposal plants or to dealers that provide a X similar service Separate waste disposal of electrical and electronic appliances prevents possible negative effects on the environment and human health resulting from inadequate disposal and also allows for recovering and recycling the materials comprising the appliances to ensure significant savings in terms of energy and resources The separate disposal obligation is underlined by the crossed out dustbin symbol appearing on the product Illegal disposal of the product by the user shall determine the application of the administrative sanctions defined by the regulations in force improve your life www argoclima com V 02 13 12
6. et the switch to OFF and remove the plug from the socket Only pull on the plug Do pull the cord Do not bend drag or twist the cord or apply force to remove it Do not use the appliance if the cord or plug are damaged this may cause the risk of fire or electric shock If the power supply cord is damaged it must be replaced by the manufacturer dealer or a similarly qualified person so as avoid any safety risks Do not place heavy objects on top of the appliance To prevent water spills empty the water tank before moving the appliance Do not tilt the dehumidifier onto one side or turn it upside down as the water which runs out could damage the appliance Do not use the appliance on unstable or sloping surfaces water spills could cause malfunctioning or unusual vibrations resulting in noisy operation The dehumidifier must be positioned at least 50 away from the wall or other obstacles so that the heat can dissipate correctly Close all open windows to maximise dehumidification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles in any way WARNING In the event of an anomaly switch the appliance off and unplug it immediately Do not dismantle repair or modify this product freely In the event of a malfunction contact the after sales service centre directly Do not immerse the power cord plug or any other appliance element in water or
7. ot used if the room temperature is lower than 5 C SWITCHING THE APPLIANCE OFF To switch the dehumidifier off press the button OFF on the control panel again The power supply is cut off and the appliance stops running Unplug the appliance if you do not intend use for some time V 02 13 10 CONTINUOUS CONDENSATE DRAINAGE The water removed from the air be collected in the special tank on the lef side of the appliance to empty the tank when full follow the instructions in the paragraph TANK FULL ALARM LED or it can be drained continuously using a PVC hose not supplied When you wish 10 use this function remove the water tank and connect the PVC hose to the continuous drainage opening The PVC hose should be positioned horizontally under the level of the drainage opening Avoid uneven floors and bending the hose Next reposition the tank Connect the hose to a continuous drainage channel LA PVC HOSE FOR CONNECTION TO THE OPENING not Ya CONTINUOUS DRAINAGE OPENING N supplied CLEANING AND MAINTENANCE MAINTENANCE FOR THE EXTERIOR SURFACE OF THE DEHUMIDIFIER A Warning Always unplug the appliance before cleaning it otherwise electric shocks and malfunctions may occur A Warning Do not wet the appliance or immerse it in water otherwise electric shocks may occur Use a damp soft cloth to cle
8. tarts running again this delay in start up protects the compressor from potential damage If after following the appliance start up instructions the dehumidifier does not start and the operating light does come on or if dehumidifier stops for no reason make sure the plug and power cord are good working order After doing so wait for 10 minutes and then restart the appliance If the dehumidifier still does not start after 10 minutes or if either the power cord or plug is damaged switch off the appliance and contact an after sales service centre WARNING When the dehumidifier is running the compressor produces heat and the appliance emits warm air into the room The room temperature will therefore tend to increase This is completely normal TANK FULL ALARM LED A When the tank is full of condensate the TANK FULL alarm LED A turns on and the appliance stops running Remove the tank and empty 1 then reposition it correctly the appliance will resume operation Use both hands when emptying the water tank DEFROST LED B The appliance can operate correctly room temperature between 5 C and 32 C When the appliance is operating at a low room temperature Under 12 ice may start to form on the surface of the evaporator this could reduce overall dehumidifier efficiency When this occurs the appliance switches to defrost mode and the DEFROST LED B comes on We recommend the dehumidifier is n