1. position See Figure 20 cable management cover 14 Figure 18 Figure 20 Installation Instructions K1 Series Figure 21 3 Route cables through cable management channels See Figure 21 IMPORTANT Be sure to leave enough slack in the cables near display and arm joint to allow for full arm articulation 4 Close cable management covers on monitor arm See Figure 21 5 Repeat Steps 1 4 for lower arm Display Removal WARNING Only remove display from mount when the display can be lifted up from the mount DO NOT remove display unless the display is in the upright position See Figure 22 1 Make sure display is in the upright position 2 Remove quick release faceplate from mount by pressing quick release tab and sliding faceplate off mount See Figure 22 quick release tab Figure 22 15 K1 Series Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8800 002059 Rev06 2013 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 01 13 USA International Europe Asia Pacific p TI U gt TI U gt TU 6436 City West Parkway Eden Prairie MN 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580
2. 10 DOWN 75 CH MANUAL HEIGHT ADJUSTMENT RANGE 273 1 1075 CABLE MANAGEMENT COVER 13 LIFT ARM HEIGHT ADJUSIMENT TOTALHEIGHT ADJUSIMENT 9 11 231 4 ANI o MAX HEIGHT 32 86 834 6 U CABLE MANAGEMEN Cover HEIGHT ADJUSTMENT KNOB DESKTO P THICKNESS RANG E 12 7 50 MAX 3 25 82 6 K1 Series Installation Instructions DIMENSIONS CONTINUED K1P100 POLE CLAMP RANGE 1 50 1 90 38 1 50 8 2 297 MAX 19 12 QUICK RELEASE ne VESA INTERFACE a gol 75 90 INTERFACE 02 95 ROTATION GH MANGEMENT E COVER PITCH TENSON ADJ USIMENT e o 13 6046 50 HEIGHTADJ USTMENT CABLE MANGEMENT COVER a 2 50 PLEO E 190 748 26 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 34 92 887 2 172 MAX 19 00 03 937 02 953 90 INTERFACE ROTATION QUICK RELEASE SE Ae VESA INTERFACE 75 R N CABLE MANAGEMENT COVER 13 LIFT ARM HEIG HT ADJ USMENT 519 4 MAX 20 45 nye TH 176 517 6 95 CABLE MANAGEMENT COVER a N d Installation Instructions K1 Series LEGEND Tight
3. 845 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 SCH K d D O S consumer
4. of desk or wall face r top view 90 degrees range of motion Figure 16 Dual Arm Models K1D200 K1C200 K1W200 AND K1P200 1 Adjust arm angles as desired within a 90 degree range from the edge of desk or wall and a perpendicular centerline of mount See Figure 17 WARNING Swinging the arm beyond this range may result in the mount slipping of the desk causing serious injury 13 K1 Series Installation Instructions Portrait Adjustment to 1 The monitor may be adjusted 90 degrees in either direction in order to provide a portrait view of the monitor See Figure 19 edge of desk or wall face p view 90 degrees range i perpendicular centerline Co 1 2 3 Figure 17 lumn Height Adjustment K1C Series only Loosen column adjustment knob See Figure 18 Adjust height to desired level See Figure 18 Figure 19 Tighten column adjustment knob See Figure 18 WARNING Only remove display from mount when the display can be lifted up from the mount DO NOT remove display unless the display is in the upright position See Display Removal section for details Cable Management 1 Use screwdriver to unhinge tab on either end of cable management cover on upper arm See Figure 20 2 Slide screwdriver along edge of cover until remaining tabs are unhinged and cover is in the open
5. 5 MANAGEMENT COVER l 1 SCH K1 200 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 34 92 887 H 03 937 02 953 EXTENSION ETNE MIN 2 09 53 2 MAX 19 9 505 ROTATION QUICK RELEASE le VESA INTERFACE 75 5 q CABLE MANAG EMENT COVER Installation Instructions K1 Series K1C100 DIMENSIONS CONTINUED 188 1 741 8 85 224 7 FOR LOWER PROFILE INSTALL LOWER PRO FILE INSTALL EXTENSION 100 MIN 2 13 54 0 LOWER PROFILE INSTALL MAX 21 7 551 2 90 INTERFACE Ri QUICK RELEASE ROTATION VESA INTERFACE CABLE MANAG EMENT PITCH RANGE COVER 10 DOWN 13 UFTARM HEIGHT 75 UP PITCH TENSION ADJ USTMENT s ga ADJ USIMENT Lis TOTAL HEIGHT ADJ USTMENT MN HEIGHT MANUAL HEIGHT 9 11 231 4 ADJUSTMENT RANGE LOWER MAX HEIGHT 273 1 PROFILE 32 86 834 6 10 75 INSTALL CABLE MANAGEMENT COVER A D eeh 1 bei HEIGHT ADJ USTMENT KNOB DESKTOP THICKNESS RANGE q 127 j 50 z MAX 3 25 82 6 bel Leg 38 1 3 00 1 50 K1C200 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 36 5 927 1 90 INTERFACE ROTATION EXTENSION QUICK RELEASE MIN 2 13 54 0 VESA INTERFACE MAX 19 5 495 3 PITCH RANGE
6. INSTALLATION INSTRUCTIONS K1C100 oF Height adjustable Monitor Arm Series i CHIEF K1 Series Our Mounts Your Vision K1 Series Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved A IMPORTANT SAFETY INSTRUCTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of
7. ctions K1 Series DIMENSIONS K1D100 MIN 2 09 53 14 MAX 19 9 505 5 90 INTERFACE ROTATION PIICHRANGE QUICK RELEASE 10 DOWN VESA INTERFACE 75 UP PICH TENSION ADJUSTMENT d HEIGHT ADJUSTMENT 14 7036 5 373 4 165 10 CABLE MANAGEMENT COVER L2 D H DESKTOP THICKNESS RANGE 5 19 05 ae MAX 2 50 63 5 R 8 118 3 K1D200 MAXIMUM WIDTH OF 2 PARALLEL FORWARD FACING DISPLAYS 34 92 887 EXTENSON MIN 2 09 53 2 MAX 19 9 505 90 INTERFACE ROTATION QUICK RELEASE 10 DOWN VESA INTERFACE 75 UP CABLE MANAGEMENT COVER CABLE MANAGEMENT COVER DESKTOP THICKNESS RANG E 19 1 75 MIN 2 50 MAX 63 5 4 65 K1 Series Installation Instructions DIMENSIONS CONTINUED K1W100 13 LIFT ARM HEIG HT ADJ USTMENT CABLE MANAGEMENT COVER QUICK RELEASE 100 VESA INTERFACE D 3 94 EXTENSION MIN 2 09 53 2 90 INTERFACE 75 MAX 19 9 505 ROTATION 92 PITCH RANGE ABLE 10 DOWN MANAGEMENT a j l VER PITCH TENSION ADJ USTMENT GHT ADJ USTMENT 39 399 165 1 15 CABLE 15 7136
8. en Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con lapiz Stiftmarkierung Marcar com lapis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis a pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschlussel Chave de bocas Chiave a punte aperte Steeksleutel Cl a fourche Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez By Hand A mano Von Hand Com a mao A mano Met de hand A la main Optional Opcional Optional Opcional Opzionale Optie En option e y V 2 Hex Head Wrench Llave de cabeza
9. f display See Figure 13 Using Phillips screwdriver carefully install four M4x25mm screws C through corresponding holes on faceplate spacers D and into the mounting mounting holes on the display See Figure 13 Z E G L NE ei X o an release tab Wi Figure 11 WARNING Only remove display from mount when the display can be lifted up from the mount DO NOT remove display unless the display is in the upright position See Display Removal section for details 2 Carefully place display face down on protective surface 3 Connect faceplate to display For flush mounting hole installation Using Phillips screwdriver carefully install four M4x14mm screws B through corresponding holes on faceplate and into the mounting holes on the display See Figure 12 for recessed mounting holes quick release faceplate Figure 13 4 Position display with faceplate attached above mount See Figure 14 5 Slide faceplate onto mounting head until quick release tab clicks into place See Figure 14 for flush mounting holes e quick release faceplate pg Figure 12 12 Figure 14 Installation Instructions K1 Series Adjustments Head Tilt Adjustment 1 Adjust head tilt to desired tilt position See Figure 15 2 Adjust head tilt tension screw to change the adjustment
10. factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located between the K1 Series Monitor Arm up to and including the display does not exceed 25 Ibs 11 34 kg per arm Use with products heavier than the maximum weight indicated may result in collapse of the mount and its accessories causing possible injury WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING Never operate this mounting system if it is damaged Return the mounting system to a service center for examination and repair WARNING Do not use this product outdoors SAVE THESE INSTRUCTIONS Installation Instru
11. hexagonal Sechskantschl ssel Chave de cabeca sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale s GI YD Security Wrench Llave de seguridad Sicherheitsschl ssel Chave de seguran a Chiave di sicurezza Veiligheidssleutel Cl de s curit K1 Series Installation Instructions TOOLS REQUIRED FOR INSTALLATION e 12 345 3 16 included t 1 8 included 5 32 included with K1P Series only PARTS monitor arm K1D100 shown x 8 screws and spacers B 4 or 8 C 4 or 8 D 4 or 8 included with dual arm mounts M4x14mm M4x25mm M10x5 3x10 N included with K1W Series wall mount only S F 2 1 4 x 2 1 2 1 4 J 4 K 4 1 4 20x 1 1 2 1 4 20 x 1 1 g lamp L 1 1 pole c 5 32 M 1 N 1 3 16 1 8 Installation Instructions K1 Series Assembly And Installation Connecting K1C Series column mount to Desk Standard Installation 1 Loosen clamp screw until enough space is created between clamp and mount to allow for desk mounting See Figure 1 NOTE If space is limited behind desk i e against wall etc remove clamp screw and attachment entirely and reattach clamp screw prior to Step 3 See Figure 2 2 Place mount on top of desk at desired mounting location See Figure 1 3 Tighten clamp using cla
12. ll wall bracket onto wall See Figure 9 IMPORTANT Overtightening screws F may cause bracket to compress into soft wall surface resulting in difficult mount installation or improper engaging of set screw in Step 6 5 6 Hang monitor arm A over wall bracket See Figure 9 Secure monitor arm to wall bracket by tightening set screw Ensure set screw engages back side of wall bracket E to properly secure mount See Figure 9 Connecting K1P Series to Pole 1 Determine approximate location for mount keeping in mind display size extension height adjustment requirements Place mount A against pole with clamp H on opposite side of pole See Figure 10 K1P assembly 3 Figure 10 Using 5 32 hex key L and appropriate length screws loosely attach K1P assembly to pole clamp H If installing to 1 1 2 NPT pipe use 1 4 20 x 1 1 2 button head cap screws J If installing to 1 1 2 diameter pipe use 1 4 20 x 1 button head cap screws K See Figure 10 Position mount at desired height and orientation Equally tighten screws against mount and the pole clamp 11 K1 Series Installation Instructions Display Installation 1 Remove quick release faceplate from mount by pressing quick release tab and sliding faceplate off mount See Figure 11 Zei EWA For recessed mounting hole installation Place four spacers D on top of mounting holes on back o
13. mp screw until mount is securely fastened to desk See Figure 1 Figure 1 Figure 2 Low Profile Installation K1C Series Only 1 Remove top cap from column See Figure 3 2 Slide mount assembly off of column See Figure 3 Figure 3 3 Rotate mount in 90 degrees in either direction prior to reinstalling onto column See Figure 4 4 Reinstall onto column and adjust to desired height See Figure 4 5 Reinstall top cap to column See Figure 4 Figure 4 6 Proceed with standard installation to desk as shown in Standard Installation section K1 Series Installation Instructions Connecting K1D Series desk mount to Desk 1 Loosen clamp screw until enough space is created between clamp and mount to allow for desk mounting See Figure 5 NOTE If space is limited behind desk i e against wall etc remove clamp entirely in Step 1 and reattach clamp prior to Step 3 2 Place mount on top of desk at desired mounting location See Figure 5 3 Tighten clamp using clamp screw until mount is securely fastened to desk See Figure 5 desk 9 Figure 5 Grommet Hole Option NOTE While the K1D Series mounts may be installed directly to grommet holes as detailed here it is recommended that Chief s KRA202 grommet accessory be used for a more secu
14. re mount NOTE Depending on the depth and size of the grommet hole the clamp may not need to be totally removed from the clamp but just loosened enough to manuever through the hole See Figure 6 1 Remove desk clamp from mount by loosening button head cap screw until clamp is completely disengaged from the bolt See Figure 7 Manuever clamp so that it is totally removed from desk mount See Figure 7 Figure 7 3 Locate a flat surface thickness of 3 4 minimum to 3 1 2 maximum on which to mount the column plate 4 If mounting hole does not already exist on desk drill mounting hole in desk at desired mounting location IMPORTANT Mounting hole must be a minimum of 5 16 in diameter 5 Place mount on desk over grommet hole See Figure 8 6 Manuever desk clamp through grommet hole and into mount See Figure 8 7 Reinstall button head cap screw into clamp and tighten until secure See Figure 8 Figure 6 10 Figure 8 Installation Instructions K1 Series Figure 9 Connecting K1W Series wall mount to Wall 1 2 3 Determine mounting location on wall Use a stud finder to locate 2 x 4 wood stud Use wall bracket to mark and drill two 3 16 x 2 1 2 holes in wall at desired mounting location See Figure 9 Use two 1 4 2 1 2 hex head lag screws F and two 1 4 washers G to insta
15. tension See Figure 15 Height Adjustment CAUTION OVERTENSIONING THE HEIGHT ADJUSTMENT TENSION SCREW MAY CAUSE DAMAGE Do NOT overtighten height adjustment tension screw when adjusting tension for lighter or heavier displays 1 Adjust arm height to desired level See Figure 15 2 Open cable management cover on upper arm to expose height adjustment tension screw See Cable Management section for details 3 Use 1 8 hex key J to adjust height adjustment tension screw to change adjustment tension See Figure 15 NOTE Turn clockwise to reduce tension for lighter displays and counter clockwise to increase tension for heavier displays 4 Close cable management cover on upper arm See Cable Management section for details Pivot Adjustment 1 Adjust pivot position as desired See Figure 15 2 Use 3 16 hex key H to adjust pivot point tension screws to change pivot adjustment tension See Figure 15 Reduce tension lighter display e gt ncrease tension heavier display 62 Do NOT overtension A adjustment tension screw head tilt tension pivot point tension Figure 15 Pivot Adjustment Range Single Arm Models K1D100 K1C100 K1W100 and K1P100 1 Adjust arm angle as desired up to 90 degrees in either direction See Figure 16 WARNING Swinging the arm beyond 90 degrees may result in the mount slipping off the desk causing serious injury edge