Home

Hunter Sonora - 52"

image

Contents

1. For Your Records and o Warranty Assistance 10 e VA S For reference also attach your receipt or a copy J j INA e J F E TAT A M a of your receipt to the manual Owner s Guide and Installation Manual SINCE 1886 a Form 42650 01 20090817 2009 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING Table Of Contents INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the 1 Getting Ready support structure of the building according to these instructions 2 Installing the Ceiling Plate and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock 5 e
2. Cleaning Your Ceiling Fan Turn on electrical power to the fan 8 2 The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off 8 3 8 4 8 5 e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish To Change Airflow Direction Turn the fan off and let it come to a complete stop Slide the reversing
3. Installing the Canopy and Canopy the circuit breakers in the off position securely fasten a prominent Trim Ring warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a Solid state speed control with this fan Use only Hunter speed controls Welcome 3 e Assembling and Hanging the Fan 6 4 Wiring the Fan 6 Assembling the Blades 7 Completing Your Installation With or Without a Light Fixture 8 Operating and Cleaning Your Ceiling 2009 Hunter Fan Company 2 42650 01 08 17 09 Hunter Fan Company K2 Installer s Choice and Optional Accessories Understanding Mounting and Installers Choice Hunter s patented 3 position mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of three ways depending on ceiling height and your preference Low Profile Standard or Angle mounting The steps in this manual include Support Brace Ceili f i Standard m Box instructions for all three Installer s Choice mounting method
4. swinging the canopy for alignment Holding the canopy up with the screw holes aligned partially install two canopy screws into the holes opposite the ceiling plate tabs Partially install a canopy screw between the slots in the canopy When all the holes are properly aligned securely tighten all three canopy screws Verify that the tabs in the canopy are still in the grooves of the hanger ball Align the tabs on the trim ring opposite the grooves in the hanger ball Using both hands push the canopy trim ring up to the top of the canopy The canopy trim ring will snap and lock into place Note Should you need to remove the trim ring press firmly on opposite sides of the trim ring directly above the groove in the hanger ball The tabs will flex out releasing the canopy trim ring Step 5 1 Step 5 2 Step 5 3 Canopy gt Canopy Trim Canopy Screw 8 42650 01 08 17 09 Hunter Fan Company K2 6 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 Your fan may include blade grommets If your fan has grommets Step 6 1 Detail insert them by hand into the holes on the blades 6 2 Attach each blade to a blade iron using three blade assembly screws If you used grommets the blades may appear slightly loose after screws are tightened This is normal 6 3 Remove the blade moun
5. switch on the fan to the opposite position Restart fan 42650 01 08 17 09 Hunter Fan Company 14 a J Reversing Switch In warm weather use downward air flow pattern In cold weather use upward air flow pattern j o ENERGY SAVINGS Hunter fans have the power to cut your cooling costs up to 40 d A Beat the High Cost of Cooling The air movement created by a Hunter ceiling fan lets you set your thermostat higher and still stay comfortable Every degree you raise the thermostat saves up to 7 on energy costs So you can cut back on expensive air conditioning and save up to 40 on cooling In winter your Hunter fan recirculates warm air and saves up to 10 on heating bills On average at low speed settings Your savings may vary based on climate building type and thermostat setting Save Energy and Money While Protecting the Environment Congratulations You re saving energy and money while protecting the environment by purchasing this ENERGY STAR qualified Hunter ceiling fan With this purchase you are doing your part to protect the environment In 2010 ENERGY STAR qualified ceiling fans are projected to cut air pollution by more than 500 million pounds Your new ceiling fan has earned the ENERGY STAR label because it meets high energy efficiency specifications set by the Environmental Protection Agency EPA ENERGY STAR labeled ceiling fans save energy because they have
6. d Hanging the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 3 1 Unbundle the wires from the fan For Standard or Angle mounting 3 2 Insert the downrod through the canopy and canopy trim ring Feed the wires from the fan through the downrod on one side of the pin in the ball 3 3 Loosen the square head set screw on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the set screw with a wrench or pliers Skip to step 3 7 A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the set screw from the adapter 3 5 Place the low profile washer into the canopy with the lip down 3 6 Align the holes in the washer with the holes in the adapter Assemble securely with three low profile screws Hanging the Fan Note To hang the fan you must tilt the canopy to an almost vertical position so that the canopy slots sit on the ceiling plate hooks 3 7 Raise the fan and align the slots in the canopy with the hooks on the ceiling plate 3 8 Place the slots over the hooks to hang the fan 6 Stan
7. dard or Angle Mounting Steps 3 2 3 3 9 mm Downrod lt Canopy lt Canopy Trim Ring Set Screw d Low Profile Mounting Steps 3 5 3 6 Low Profile Screws E T Fa nA Ground aster Wire Canopy Trim Ring a in Low Profile Screw Step 3 6 Detail Adapter Low Profile Screw Low Profile Washer 42650 01 08 17 09 Hunter Fan Company K2 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 1999 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes 4 1 Before attempting installation make sure the power is still off 4 2 To connect the wires hold the bare metal leads together and place a wire nut over them then twist clockwise until tight For all these connections use the wire connectors provided 4 3 Connect the bare or green ground wire grounding from the ceiling to the green ground wire grounding from the ceiling plate and the green ground wire from the fan 4 4 Connect the white wire grounded from the ceiling to the white wire grounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring e The black wire ungrounded from the ceiling to the black wire ungrounded from t
8. er or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 1 866 268 1936 Preparing the Fan Site Before you begin installing the fan follow all the instructions in the pullout sheet called Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 4 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 42650 01 08 17 09 Hunter Fan Company K2 2 Installing the Ceiling Plate A CAUTION To avoid possible electrical shock before installing your fan Towards disconnect the power by turning off the circuit breakers to the outlet box Ceiling Peak and associated wall switch location If you cannot lock the circuit breakers in the o
9. ff position securely fasten a prominent warning device such as a tag to the service panel 2 1 Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 in diameter For Angled Ceilings Be sure to orient the ceiling plate so that the two tabs are pointing towards the ceiling peak For Angled Ceilings Be sure to orient es the ceiling plate so that the two tabs 2 2 Your fan comes with four preinstalled noise isolators Check to are pointing towards the ceiling peak make sure all four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the hole in the center of the ceiling plate 2 5 Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure For proper alignment use slotted holes directly across from each other Note The isolators should be flush against the ceiling 2 6 Pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Flat Washer 3 Wood Steps 2 3 2 6 Screw eee FU VUEUUUNUEEEEDD OU Nias 5 42650 01 08 17 09 Hunter Fan Company K2 3 Assembling an
10. he fan e The black white wire ungrounded from the fan to the wire ungrounded for the wall switch Single Switch Wiring e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections 4 6 Turn the splices upward and push them carefully back through the ceiling plate into the outlet box 4 7 Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 7 a mix Wire Connector Dual Switch Wiring S Le il Wo nem Single Switch Wiring gt i 42650 01 08 17 09 Hunter Fan Company K2 5 Installing the Canopy and Canopy Trim Ring A WARNING Failure to complete the following steps could cause the fan to fall Note It is recommended you use a magnetic tip screwdriver for the following steps 5 1 5 4 D2 Rotate the hanger ball so the tab in the canopy is secure in the hanger ball groove Note Your fan may have multiple tabs and grooves that must be aligned Swing the fan up to align the canopy screw holes with the mounting holes on the ceiling plate A WARNING The slots in the canopy must remain engaged while
11. more efficient fan motors and air delivery due to more aerodynamic blade configurations Ceiling fan models bearing the ENERGY STAR label move air 14 20 more efficiently than typical ceiling fan models For more information on ENERGY STAR visit www energystar gov 15 42650 01 08 17 09 Hunter Fan Company oy 9 Troubleshooting Problem Nothing happens fan does not move 1 2 5 6 Problem Noisy operation Turn power on replace fuse or reset breaker Loosen canopy check all connections according to the wiring the Check the plug connection in the switch housing Push motor reversing switch firmly left or right to ensure that the switch is engaged Pull the pull chain to ensure it is on Remove the shipping bumpers 1 Tighten the blade assembly screws and blade iron armature screws 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit 2 Tighten all blade iron screws and instructions to balance the fan 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights dim when turned on or do not turn on 1 Check to make sure wattage of light bulbs installed match the specifications on the light socket Problem If the light on this fan shuts off suddenly 1 Turn the power to the fan off at the wall swi
12. n Finial 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 7 14 7 15 7 16 7 17 7 18 7 19 7 20 7 21 7 22 Remove the lower switch housing screws then remove the lower switch housing Lower Switch To uninstall the light fixture first disconnect the 9 pin plug Housing connectors between the black wire and the black white wire Lower Switch Housing Disconnect the plug connectors between the two white wires Screw Uninstall the nut and washer from the end of the light fixture inside the lower switch housing Unscrew the threaded rod of the light fixture from the lower switch housing Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector female through the hole Steps 7 14 7 19 Install the switch housing cap and plug button to the lower switch Threaded Rod housing Once you have uninstalled the light fixture continue with step 7 6 Re attach the lower switch housing back to the fan and reinstall the lower switch housing screws Plug Button _ Step 7 20 13 42650 01 08 17 09 Hunter Fan Company K2 8 1 8 Operating and
13. nergy regulations this ceiling fan contains a device that restricts the light kit toa Plug T maximum of 190 Watts Exceeding that limit or the marked A limit on this product may result in fire hazard or improper operation Housing _ Assembly Screw lI 42650 01 08 17 09 Hunter Fan Company oy 7 Completing Your Installation With or Without a Bowl Light Fixture Installing the Glass Bowl Step 7 10 7 8 If you want to install the light fixture proceed with Step 7 9 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture in Step 7 14 Once you have uninstalled the light fixture continue with step 7 6 7 9 Attach the extra pull chain included Fan to the fan pull chain using the plastic Pull Chain breakaway connector You may find the plastic breakaway connector on the end Grommet Hole of the extra chain Metal Disk 7 10 Feed the fan and light pull chains as shown in Step 7 10 illustration 7 11 Install the Pin Base CFL 26 Watt Maximum into the socket 7 12 Place the cover plate up against the glass bowl Align the holes in the cover plate with the grommet hole of the metal disk it Chain 7 13 Screw the finial onto the threaded rod end until tight Hole Cover Plate Breakaway Connector 12 42650 01 08 17 09 Hunter Fan Company Light Bulb Pin Base CFL Light Pull Chain Light Pull Chai
14. s Mounting gt Style Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum Standard Mounting hangs from the performance of your Hunter fan use only Hunter speed controls ceiling by a downrod included For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance Support Brace A CAUTION To reduce the risk of personal injury attach the fan directly to the Mounting Low Profile _ support structure of oe Outlet Box the building according SY 7 to these instructions and use only the yY a Voo hardware supplied Angle Mounting recommended for a Low Profile Mounting fits close to the vaulted or angled ceiling ceiling recommended for ceilings less than 8 feet high 3 42650 01 08 17 09 Hunter Fan Company K2 l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed install
15. tch Wait 30 seconds then resume power to the fan If you need parts or service assistance please call 888 830 1326 In Canada call 1 866 268 1936 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Pkwy 400 Memphis Tennessee 38016 16 42650 01 08 17 09 Hunter Fan Company K2
16. three screws firmly A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling 7 5 If you want to install the light fixture proceed with step 7 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture on step 7 15 Once you have uninstalled the light fixture continue with step 7 6 10 42650 01 08 17 09 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued 7 6 To attach the lower switch housing connect the upper plug Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product lt _ ___ Plug Connector Steps 7 6 7 7 Lower Switch Housing Note In compliance with US federal e
17. ting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to secure shipping blocks 6 4 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet screws Use without grommet Blade Mounting Screw 42650 01 08 17 09 Hunter Fan Company K2 7 Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button This feature gives you the option of installing the fan with OR without the included light fixture The steps below direct you whether or not you are installing a light fixture A WARNING Use only the light fixture supplied with this fan model 7 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 7 2 Feed the upper plug connector through the center opening of the housing 7 3 Align the keyhole slots in the housing with the housing assembly screws Steps 7 1 7 3 Housing 7 4 Turn the housing counterclockwise until the housing assembly Assembly a screws are firmly situated in the narrow end of the keyhole slots Screw n r Install the remaining screw into the housing Tighten all

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE USUARIO portal - Centro Universitario UTEG    Baseboarders BB001-36 Installation Guide : Free Download, Borrow, and Streaming : Internet Archive  Intel Xeon E5-1428L  Targus TST234CA  

Copyright © All rights reserved.
Failed to retrieve file