1. CONSEQUENTAIL OR INDIRECT COSTS EXPENSES OR DAMAGES This warranty provides you with specific legal rights and you may have other rights that vary by jurisdiction Because of special local requirements some of the above limitations and exclusions may not apply to you FOR CUSTOMER SERVICE Visit our web site at www omronhealthcare com Call toll free 1 800 634 4350 293 SPECIFICATIONS Model BP742 HEM 7200 Z Display LCD Digital Display Measurement Range Pressure 0 to 299 mmHg Pulse 40 to 180 min Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Inflation Automatic by electric pump Deflation Automatic pressure release valve Rapid Air Release Automatic exhaust valve Measurement Method Oscillometric method Power Source 1 5V 4 AA batteries Battery Life Approx 300 uses with 4 new alkaline batteries Operating Temperature 50 F to 104 F 10 C to 40 C 15 to 90 RH Humidity Storage Temperature 4 F to 140 F 20 C to 60 C 10 to 95 RH Humidity Air Pressure 700 1060 hPa Main Unit Weight Approximately 12 oz 340g not including batteries Main Unit Dimensions Approx 5 1 2 1 x 4 7 8 w x 3 3 8 h 141 mm x 123 mm x 85 mm Cuff Size Approximately 5 3 4 w x 17 1 2 1 146 mm x 446 mm Cuff tube 23 5 8 600 mm Cuff Circumference Fits arm circumferences 9 to 13 220 mm to 320 mm Memory Up to 30 readings per user Contents Main Unit Standard Adult
2. the current month The day flashes on the display Press the Up button to advance by increments of one day Press the Date Time Setting button to set the current day The hour flashes on the display The time is set using AM or PM Press the Up button to advance by increments of one hour Press the Date Time Setting button to set the current hour The minute flashes on the display Press the Up button to advance by increments of one minute Press the Date Time Setting button O to set the minute setting TO TURN THE MONITOR OFF Press the START STOP button NOTE The monitor will automatically turn off five minutes after the minute has been set 13 APPLYING THE ARM CUFF A CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit A CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions APPLYING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper arm 14 APPLYING THE ARM CUFF 3 Apply the cuff to your left upper arm so Left Arm the arrow is centered on the inside of your arm A and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff sh
3. Arm Cuff 4 AA Alkaline Batteries Instruction Manual and Quick Start Guide 26 SPECIFICATIONS Optional Accessories Large Cuff 13 17 320 mm 420 mm AC Adapter Type B NOTE These specifications are subject to change without notice 2 Omron Healthcare Inc 1200 Lakeside Drive Bannockburn IL 60015 www omronhealthcare com Copyright 2010 Omron Healthcare Inc Made in China 5329417 5A
4. IN NO KNOW YOUR UNIT Main Unit Battery compartment Y o A START STOP button Display Air Jack 79 A USER ID SY ST ie Selection Switch AC adanter Jack Up Down Ca gt buttons i Date Time setting button Components GETTING STARTED Standard Adult Arm Cuff Instruction Quick Start Manual Guide UNIT DISPLAY Systolic blood pressure Diastolic blood pressure d z 113 Heartbeat symbol Memory symbol 4 Di IL Hypertension Indicator Displayed when viewing Ci Li I LI values stored in memory E 4P hd Pulse display Movement error symbol nm Deflation symbol z n Irregular Heartbeat symbol Baw User ID symbol A B Battery low indicator Date Time Display 7 DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL W When the monitor detects an irregular rhythm two or more times during the measurement the Irregular Heartbeat Symbol op will appear on the display with the measurement values An irregular heartbeat rhythm is defined Normal Henrtbeat as a rhythm that is more than 25 slower or 25 faster from the average Pulse AAAA rhythm detected while the monitor is Blood f AN KAS measuring the systolic and diastolic ee blood pressure Irregular Heartbeat If the irregular heartbeat symbol Short Long displays with your measurement results Pulse we recommend you consult your sisi physician Follow the directions o
5. OMRON INSTRUCTION MANUAL 5 series Blood Pressure Monitor Model BP742 pesi e Z a 7A LUI ENGLISH TABLE OF CONTENTS Before using the Monitor I ULI BO CG COI RR RR ital t i ul N I 3 Satety MEO sua n N RI RR RR RPR RI IRI RO RR RI RE Gove E EEs 4 Operating the Device sansa a ii altaice a e ad 4 Care and Mal Lena DOE criar 5 Operating Instructions Before Taking a Measurement siii 6 Kkoow Yonar Ba BARRE RR RI RR NT 7 Libia ri Display I III OLS noa ac Dati iad cot aie Dl de ENAA 8 Irregular Heartbeat Symbol cciecsccsssesecsnecessesssnensasesesecesesennsaneooses 8 Movement Error Symbol scossi 8 Heartbeat Symbol Hypertension Indicator 8 Battery Installation lla 10 Seting the Date and TM 12 Appin he Arm CUIT semnezi nete ie Ze ren da a taie biti 14 Taking a Measurement idonea 16 Special OMS serur ta ata aa iata aaa nf 18 Using the Memory Function criniera ris 19 To Display the Measurement Values 19 To Delete All Values Stored in the Memory 20 Care and Maintenance iii 21 FRI risa 22 Troubleshooting TIPS ernia 23 GSAS leleine 24 Limited Warranlies JJ 25 Be LIC A OIG APR RI PRR IRI RR AR RI N RR OSESE 26 INTRODUCTION Thank you for purchasing the OMRON BP742 IntelliSense Automatic Blood Pressure Monitor Fill in for future reference DATE PURCHASED SERIAL NUMBER Staple your purchase receip
6. deleted e When the batteries are replaced you may need to reset the date and time If appears on the display refer to Setting the Date and Time e The supplied batteries may have a shorter life A CAUTION Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution 11 SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time If the date and time has not been set the measurement values are stored without any date or time information 1 TO START THE SETTING Press the Date Time Setting button to adjust the date and time The year flashes on the display 2 SETTING THE YEAR The year can be set between 2010 and 2040 When the display reaches 2040 it will return to 2010 Press the Up button to advance by increments of one year Press the Date Time Setting button to set the current year The month flashes on the display NOTES Press the Down button Ca to decrease the date and time values by increments of one Press and hold the button to increase or decrease the date and time values faster 12 SETTING THE DATE AND TIME Pa SETTING THE DAY SETTING THE HOUR SETTING THE MINUTE SETTING THE MONTH Press the Up button to advance by increments of one month Press the Date Time Setting button to set
7. e device or any of the components in water A Store the device and the components in a clean safe location A Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations 1 Avoid eating drinking alcohol smoking exercising and bathing for 30 minutes before taking a measurement Rest for at least 15 minutes before taking the measurement Stress raises blood pressure Avoid taking measurements during stressful times Measurements should be taken in a quiet place Remove tight fitting clothing from your left arm Sit on a chair with your feet flat on the floor Rest your left arm on table so that the cuff is at the same level as your heart Remain still and do not talk during the measurement Wait 2 3 minutes between measurements The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement You may need to increase the wait time depending on your individual physiological characteristics 8 Keep a record of your blood pressure and pulse readings for your physician A single measurement does not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at the same time each day for consistency MA BW
8. e measurement is started As the cuff deflates decreasing numbers appear on the display and the Heartbeat Symbol 49 flashes deflates Your blood pressure and pulse rate are displayed NOTE The monitor will automatically turn off after five minutes 17 TAKING A MEASUREMENT SPECIAL CONDITIONS A CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied If your systolic pressure is known to be more than 220 mmHg press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure NOTES Do not apply more pressure than necessary e The monitor will not inflate above 299 mmHg When the measurement is complete the arm cuff completely deflates Your blood pressure and pulse rate are displayed 18 USING THE MEMORY FUNCTION The monitor is designed to store the blood pressure and the pulse rate in the memory for two people USER A and USER B every time a measurement is completed The monitor automatically stores up to 30 sets of measurement values blood pressure and pulse rate for each user A and B When 30 sets of measurement values are stored the oldest record is deleted to save the most recent values TO DISPLAY THE MEASUREMENT VALUES 1 Press the START STOP button to turn the monitor on 2 Select your USER ID A or B 3 Press the Up button L gt to display the most recent set of measurement values o
9. e provider A The monitor is not intended to be a diagnostic device A If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact a physician immediately A Read all of the information in the instruction manual and any other literature in the box before operating the unit A This device is intended for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions A Read the Special Conditions section of the instruction manual if your systolic pressure is known to be more than 220 mmHg Inflating to a higher pressure than necessary may result in bruising where the cuff is applied A Operate the device only as intended Do not use the device for any other purpose A Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution SAFETY INFORMATION A Do not use a cellular phone near the device It may result in an operational failure A Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit A Use only 1 5 V AA alkaline batteries with this device Do not use other types of batteries This may damage the unit CARE AND MAINTENANCE A Do not subject the monitor to strong shocks such as dropping the unit on the floor A Do not submerge th
10. es cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the product and the receiver e Connect the product into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Clase B prescrites dans la norme sur le materiel brouilleur Appareils Num riques ICES 003 dict e par le minister des communications Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 24 LIMITED WARRANTIES Your BP742 IntelliSense Automatic Blood Pressure Monitor excluding the arm cuff is warranted to be free from defects in materials and workmanship appearing within 2 years from the date of purchase when
11. f your pres fap n SISAL doctor MOVEMENT ERROR SYMBOL The Movement Error Symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes Reapply the arm cuff and take another measurement HEARTBEAT SYMBOL HYPERTENSION INDICATOR 4g TAKING A MEASUREMENT The Heartbeat Symbol 49 flashes on the display during the measurement The Heartbeat Symbol 42 flashes at every heartbeat When the measurement is complete the Heartbeat Symbol AR flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and or above 85 for the Diastolic Blood Pressure value USING THE MEMORY FUNCTION The Heartbeat Symbol 49 flashes when the blood pressure reading stored in the memory 1s above 135 for the Systolic Blood Pressure value and or above 85 for the Diastolic Blood Pressure value DISPLAY SYMBOLS The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity The AHA recommends a lower home blood pressure goal for certain patients including diabetic patients pregnant women and patients with renal failurel A WARNING The monitor is not intended to be a d
12. iagnostic device A WARNING Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider Omron Healthcare recommends you contact your physician if the Heartbeat Symbol 42 flashes on the display with your measurement values l American Heart Association Scientific Statement 2004 BATTERY INSTALLATION A CAUTION Use only 1 5V AA alkaline batteries with this device 1 Press the A indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover 10 BATTERY INSTALLATION BATTERY REPLACEMENT eX Low Battery Indicator When the Low Battery Indicator appears on the display turn the monitor off and remove all the batteries Replace with four new batteries at the same time Long life alkaline batteries are recommended A WARNING If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact a physician immediately NOTES Turn the unit off before replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results are not
13. n the screen Press the Down button Ca to display the oldest set of measurement values 19 USING THE MEMORY FUNCTION NOTES The measurement value number is displayed briefly in the Pulse Display area when you press the Up Down buttons C lt DD e The date and time are alternately displayed with the measurement values e If the date and time are not set is displayed with the measurement values e Press the button repeatedly to display the next values Alternating Press and hold the button to display the values g i amp Jdisplay faster TO DELETE ALL VALUES STORED IN THE MEMORY The values stored in the memory are deleted by USER ID You cannot partially delete values stored in the memory All values for the user you select will be deleted 1 Press the START STOP button to turn the monitor on 2 Select your USER ID A or B 3 While holding the Down button press the START STOP button down for more than five seconds until the display appears as it does in the following illustration 4 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after five minutes 20 CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below Do not forcefully bend the arm cuff or air tube Do not fold tightly Clean the monitor with a soft dry cloth Do no
14. ould be approximately 1 2 above your elbow 1 2 inch 1 2 cm 4 Wrap the cuff firmly in place around your arm using the cloth fastening N APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 3 Right Arm Apply the cuff to your right upper arm so the arrow and the air tube runs along the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow Arrow NOTE Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff 15 TAKING A MEASUREMENT 1 Press the START STOP button to turn the monitor on All symbols appear on the display Sit on a chair with your feet flat on the floor Place your arm on a table so the cuff is level with your heart Keep still and do not talk during measurement 4 Press the START STOP button The cuff starts to inflate automatically As the cuff inflates the monitor automatically determines your ideal inflation level Remain still and do not move your arm until the entire measurement process is completed NOTE To stop the inflation or measurement push the START STOP button The monitor will stop inflating start deflating and will turn off 16 TAKING A MEASUREMENT a When the measurement is complete the arm cuff completely Press the START STOP button to turn the monitor off Inflation stops automatically and th
15. surement measurement Remove the arm cuff Wait 2 3 minutes and then take another Irregular or weak measurement Repeat the steps in pulses are detected section Applying the Arm Cuff If this error continues to appear contact your doctor Replace the four batteries Batteries are exhausted Refer to Battery Installation 22 TROUBLESHOOTING TIPS No power Replace all four batteries with new ones No display appears on the unit Check the battery installation for proper placement of the battery polarities Blood pressure varies constantly Many factors including stress time of day how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement Measurement values appear too high or too low 23 FCC STATEMENT Note POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the product do
16. t here Register your product on line at www register omron com Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The BP742 comes with the following components e Monitor Standard Adult Arm Cuff e 4 AA Alkaline Batteries e Instruction Manual printed in English and Spanish Quick Start Guide The BP742 IntelliSense Automatic Blood Pressure Monitor is intended for home use SAVE THESE INSTRUCTIONS SAFETY INFORMATION To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potentially hazardous situation which if not avoided A WARNING could result in death or serious injury Indicates a potentially hazardous situation which if not avoided A CAUTION may result in minor or moderate injury to the user or patient or damage to the equipment or other property OPERATING THE DEVICE A Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcar
17. t use any abrasive or volatile cleaners Do not attempt to clean the cuff A CAUTION Do not submerge the device or any of the components in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct sunlight A CAUTION Store the device and the components in a clean safe location A CAUTION Do not subject the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will not be used for three months or longer Always replace all the batteries with new ones at the same time Use the unit consistent with the instruction provided in this manual Use only authorized parts and accessories Use the unit in a manner consistent with the instructions provided in this manual A CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit A CAUTION Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components 21 ERROR INDICATORS Take another measurement and remain still until the measurement is complete Monitor could not detect pulse wave Cuff under inflated Cuff not applied Remove the arm cuff correctly Read Taking a Measurement Wait 2 3 minutes Cuff over inflated Take another measurement EF Device error Contact Customer Service Movement during Keep still and take another mea
18. used in accordance with the instructions provided with the monitor The arm cuff is warranted to be free from defects in materials and workmanship appearing within one year from the date of purchase when the monitor is used in accordance with the instructions provided with the monitor The above warranties extend only to the original retail purchaser We will at our option repair or replace without charge any monitor or arm cuff covered by the above warranties Repair or replacement is our only responsibility and your only remedy under the above warranties To obtain warranty service contact Customer Service by calling 1 800 634 4350 for the address of the repair location and the return shipping and handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE IMPOSED BY LAW IF ANY ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL INCIDENTAL

Download Pdf Manuals