Home

Lumiscope 1143 blood pressure unit

image

Contents

1. aiga elite OM Ea e E AT 3 About Blood Pressure ccccccecessseseeeeeseeeseeeeeeeanees 4 5 Pans Identificati cessisse 6 Display Symbols amp Explanations 7 Installing the Batteries oecrcresanininanne nesis 8 Correct Measuring Posture eseese 9 Applying the Cuffs esarion 10 11 PSI TUN TPS aia EAE 12 Measurement Procedures ccccccesssseeeeeeseenees 13 14 Memory ReCalll sissrssiisenrsei ace Ea E 15 Deleting the Memory cceceeeeeteeeeeeeenneeeeeeeenteeeeenens 16 CIO CK Settings ics secs sceind daseey ceasnedix e auies ant 17 Care amp Maintenance cccceeeeceeeeeeeeeneeeeetaeeeeeeeeeaaes 18 TROUDIGSMOOUIAG iaai a 19 Specification S sr a a S 20 Wal enoii eaaa E ERRAT 21 Introduction Specifications gS SSS SSS a a ae Congratulations on your purchase of the new Lumiscope Model 1143 Model 1143 This automatic wrist blood pressure monitor is both easy to use and ideally suited for daily measurements The large display includes systolic blood pressure reading Power source 2 AAA Alkaline batteries diastolic blood pressure reading and the pulse rate all clearly shown at the completion of each reading Display System Liquid Crystal Display Measurement Method Oscillometric Measurement Range Pressure 20 300 mmHg You can store up to 85 measurements ideal for users who Pulse 40 200 beats minute want to monitor and track their blood preseureran a regular Accuracy Pressure 3 mmHg
2. 3 Battery Compartment 4 Wrist Cuff 17 6 Display Symbols amp Explanations Deleting the Memory Display Symbols DATE M D TIME MEMORY an BAN Systolic Pressure W C Diastolic Pressure Pulse Rate Display Explanations a9 Low Battery Indicator Appears when the batteries are low or need replacement amp Pulse Symbol Shows the pulse rate per minute MEMORY Memory Holds the memory for up to 85 readings pare Date and Time Shows the exact date month and M D TIME day and time of each reading Quick Read Technology Detects your blood M__ Pressure with the touch of a button To delete the memory 1 To delete one memory A Press the MEMORY button to display the record that you wish to delete A B Press and hold the START STOP button until the display shows DEL MEMORY d EL C Once the DEL has been displayed press and hold the START STOP button again After 3 beeps the selected record has been deleted 2 To delete all memories Follow steps A and B above C Press the MEMORY button until the display shows DEL ALL MEMORY dELRLL D Once the DEL ALL has been displayed press and hold the START STOP button again After 3 beeps all records have been deleted 16 Memory Recall Installing the Batteries To see the previously measured values A Press the MEMORY butt
3. co Grade 2 Hypertension Moderate fo Grade 1 Hypertension Mild D High Normal Systolic Pressure mmHg w Normal N K Optimal 80 85 90 100 110 Diastolic Pressure mmHg Care amp Maintenance Do not drop the unit It s not shock proof Do not modify or disassemble the unit or the arm cuff Use a cloth moistened with water or neutral detergent to clean the body of the unit Then wipe it dry Avoid thinner benzene and other harsh cleaners Keep the unit in a suitable place Avoid high temperature direct sunlight high moisture and dust Remove the batteries if the unit will not be used for a long time Clock Settings Parts Identification Setting the Clock Date amp Time A Press and hold the MEMORY button for over 3 seconds The display will show a blinking year Press the START STOP button to adjust the year when it s blinking B Press the MEMORY button again The MONTH will appear and blink to be adjusted the DATE HOUR and wo MINUTE will follow as you press and ii release the MEMORY button C Press the START STOP button to adjust the values of the MONTH 1 00 DATE HOUR and MINUTE when they are blinking 1 START STOP 2 Memory Select
4. etc prior to attaching the wrist monitor Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements B Apply cuff to left wrist with palm facing up as Fig A C Make sure the edge of the cuff is about 1 cm 1 2 an inch from the palm as Fig B D In order to insure accurate measurements fasten the velcro strap securely around your wrist so there is no extra space between the cuff and the wrist Fig B Note If the cuff is not wrapped tight enough the measurement values will be inaccurate Applying the Cuff Helpful Tips E If it is not possible to Here are a few helpful tips to help you obtain a more accurate reading measure on the left wrist Q attach the cuff on the right A Do not measure your blood pressure immediately after wrist as shown in Fig C consuming a large meal To obtain more accurate readings please wait one hour before measuring B Do not smoke or drink alcohol before measuring your W blood pressure C You should not be physically tired or exhausted while Fig C taking a measurement D It is important that you relax during measurement Take a 15 minute rest before a reading E Do not take measurements if you are under stress or feeling tense F Take your blood pressure at normal body temperature If you are feeling cold or hot wait a while before taking a measurement G If the monitor is stored at very low
5. basis The 1143 is compact and portable making it perfect Pulse within 5 of reading for home use and travel Inflation Electrical Rolling Pump Blood pressure measurements determined with your 1143 Pressure Exhaust Solenoid Valve are equivalent to those obtained by a trained observer Memory 85 sets using cuff stethoscope auscultation method within the limits prescribed by the American National Standard Electronic or Low Battery Indicator Yes Automated Sphygmomanometers Auto shut off 2 5 minutes after last key operation Please read this manual carefully before use For specific Battery Life Around 250 operations information on your own blood pressure contact your n physician Please be sure to keep this manual Sa ba pace 50 F 104 F Storage Environment 20 C 50 C 4 F 122 F lt 85 RH Weight Approximately 150g w batteries Dimensions 2 8 L x 2 9 W x 1 5 H Specifications are subject to change without notice Troubleshooting Message ey aoe II LII Z Correction The pressure measured was lower than 20 mmHg Solution Please measure again The pressure measured was higher than 300 mmHg Solution Please measure again Pumping error Solution Please check cuff and try again The pressure can not be measured due to signal noise Solution Please measure again The pumping pressure is higher than 300 mmHg Sol
6. temperature near freezing place it in a warm location for at least one hour before using it H Wait about 5 minutes before taking the next pressure measurement
7. 6 deep breaths Note Avoid leaning back or crossing your legs while the measurement is being taken Fig C Fig C Measurement Procedures C Quick Read Technology detects your blood pressure with the touch of a button which reduces measurement time significantly and decreases patient discomfort TIME ci TIME 2 8 i 4 ied yJ gt JJC AG De Ii l Inflating Measuring e Note It is important to remain still and quiet TIME during measurement Any 2 0 I2 5 significant movement may aos 5 mn affect measurement results IT L Results D Once the measurements have been displayed press the START STOP button to turn off the unit or it will automatically shut off after 150 seconds Start Stop Measurement Procedures To start the measurement Note In order to get your correct measurement result and to avoid erroneous measurements you should be seated quietly Your arm hand and fingers should be still during the measurement procedure A Press the START STOP button The display will initially show a flashing O I I_ Flashing 0 PER Start Stop Initial Display B After the 0 stops blinking the unit will automatically inflate to the appropriate inflation level based on the user s pulse oscillations Measurement will then begin Applying the Cuff To apply the cuff A Remove all watches jewelry
8. LUMISCOPE A Graham Field Brand Quick Read Technology Automatic Wrist Blood Pressure Monitor Model 1143 GF Health Products Inc Atlanta Georgia 30360 Made and Printed In China User Manual 1143 INS LAB RevAA08 Two Year Limited Warranty GF Health Products Inc guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase except as noted below This product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized acces sory alteration to the product or any other conditions what soever that are beyond the control of GF Health Products Inc GF Health Products Inc shall not be responsible for any type of incidental consequential or special damage All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited to the total duration of two years from the original date of purchase To obtain warranty service on your Blood Pressure Monitor please contact the Repair Department at 1 800 672 8293 There is a 15 fee for return shipping and handling Please make checks payable to GF Health Products Inc Upon receipt we will repair or replace as appropriate this blood pressure monitor and return it to you Warranty is solely through the Repair Department Service of this product by anyone other than the Repair Department voids warranty Table of Contents
9. on to recall the last reading The LCD display will show the memory number actual date and time simultaneously of the measurement Memory MEMORY Memory Number NO 4i i20 Be 8 Time gt 1 1 2G Be id B To view additional readings push the MEMORY button successively to go through the various readings 1 85 MEMORY MEMORY not ii To insert the batteries A Lift the cover towards you to open the battery compartment B Insert 2 AAA batteries as indicated Make sure to match polarities on the batteries C Replace the battery cover by inserting the two hooks at the bottom into the slot then push on the top area Note Please remove batteries when not in use for an extended period of time Do not dispose batteries with household garbage Correct Measuring Posture A Place your elbow on a table so that the cuff is at the same level as your heart Fig A Note The level of your heart is slightly below your armpit Relax your entire body especially Fig A the area between your elbow and fingers B If the cuff is not at the same level as your heart or if you can not keep your arm completely still throughout the reading use a soft object such as a folded towel to support your arm Fig B Do not allow hard objects to come in contact with the wrist cuff C Turn your palm upwards D Sit upright in a chair and take 5
10. ution Please measure again Low battery Solution Check and replace the batteries if necessary About Blood Pressure What is Blood Pressure Blood pressure is the pressure exerted on the artery tube while blood flows through the arteries The pressure measured when the heart contracts and sends blood out of the heart is systolic highest blood pressure The pressure measured when the heart dilates with blood flowing back into the heart is called diastolic lowest blood pressure Why Measure Your Blood Pressure Among the various health problems afflicting people today problems associated with high blood pressure are by far the most common High blood pressure s dangerously strong correlation with cardiovascular disease has made measuring blood pressure a necessity for identifying those at risk About Blood Pressure Blood Pressure Standard The World Health Organization WHO and National High Blood Pressure Education Program Coordinating Committee have developed a blood pressure standard according to which areas of low and high risk blood pressure are identified This standard however is a general guideline and blood pressures vary between different people age groups etc It is important that you consult with your physician regularly Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk Grade 3 Hypertension Severe