Home

Paxton Net2 RS485 TCP/IP Ethernet

image

Contents

1. 29 06 2011 Ins 30001 Net2 485 TCP IP Ethernet interface Rev4 J Paxton Technical Support 01273 811011 Support paxton co uk Technical help is available Monday Friday from 07 00 19 00 GMT Saturday from 09 00 13 00 GMT Documentation on all Paxton products can be found on our website http www paxton co uk fixed IP recommended Suitability DHCP compatible Connect over LAN WAN or VPN TMPORTANT THIS IS A NETWORK DEVICE Please contact your IT Administrator before installing this product Switchable 120 ohm resistors Fitting VQIVIVIVIVGIVIVIVIVIVOIG http paxton info 107 UL Oooooe otras BDO OOOO OOOCCO To next ACU The interface plugs directly To reset the unit to DHCP power up with into the TCP IP Ethernet the reset button held down until the unit network via a standard beeps The interface is now fully reset RJ45 connection box and will now operate in DHCP mode Unswitched fused spur LED indications 1 Power Green 12V power LED 2 Termination Red The on board resistors are in place across the RS485 data pairs 3 RX Red The interface is receiving data RS485 4 Tx Green The interface is sending data RS485 5 Server Connected Green The TCP IP interface is communicating with the PC Net2 server 6 Server Link Green 100 Mbit s Orange 10 Mbit s TCP IP speed This device requires Net2 v4 07 or later to operate KK XK eae en Ear
2. CSS Dimensions This product is not suitable for retail sale All warranties are invalid if this product is not installed by a competent person Page 4
3. ame IP range Some firewall virus protection software and other wireless hardware can block the IP detection process Disable these and try to detect the device again Please contact Technical Support if you require further advice G Net2 Server Configuration Utility General Database Wiegand Dial up nodes TCP IP nodes Net2Air Bridge Paths System Features Diagnosti_4 gt m TCP IP nodes 00 0D 44 69 3F 64 00 0E D6 0D CF 0B 00 0D D6 0E 49 79 00 0D D6 0D F 0 87 00 0D D6 0D F 0 88 00 0D D6 0D F 0 89 00 0D D6 0D F0 8B 00 F0 D6 0D F0 8C m Use the following IP address New IP address MAC address 00 0D 44 69 3F 64 00 0E D6 0D CF 06 00 0D D6 0E 49 79 00 0D D6 0D F 0 87 00 0D D6 0D F 0 88 00 0D D6 0D F 0 89 00 0D D6 0D F0 8B 00 FO D6 0D F0 8C Configuration IP address configuration Advanced Obtain an IP address automatically use DHCP UDS10 UDS10 Net2 plus Net2 plus Net2 plus Net2 plus Net2 plus Net2 plus Click Detect to automatically find any TCP IP nodes on your network fou can get an IP address assigned automatically if pour network supports this capability Otherwise you need to ask your network administrator for an IP address Delete E Rename Detect Subnet mask optional Default gateway optional TB p a PT S es Ping 255 255 0 0 v Cancel Apply Page 3 If you detect the MAC address but the device now shows Not Respondi
4. between Net2 software and the device Run the Net2 Server Configuration Utility Start Programs Net2 and Click on TCP IP nodes i Net2 Server Configuration Utility General Database Wiegand Dialup nges TCP IP nodes TCP IP nodes et2Air Bridge Paths System Features Diagnosti_4 00 0D 44 69 3F 64 00 0E D6 0D CF 0B 00 0D D6 0E 49 79 00 0D D6 0D F0 87 00 0D D6 0D F0 88 00 0D D6 0D F0 89 00 0D D6 0D F0 88 00 F0 D6 0D F0 8C IP ddress Download events Firmware version MAC address Interface mode Port number 00 00 44 69 3F 64 00 0E D6 0D CF 0B 00 0D D6 0E 43 79 00 0D D6 0D F0 87 00 0D D6 0D F0 88 00 0D D6 0D F0 89 00 0D D6 0D F0 8B 00 F0 D6 0D F0 8C Configuration P address configuration Advanced fi 0 10 7 190 Ping Iv 6 50 Name MAC address UDS10 UDS10 Net2 plus Net2 plus Net2 plus Net2 plus Net2 plus Net2 plus Click Detect to automatically find any TCP IP nodes on your network 00 0D 44 69 3F 64 C RS 232 fi 0001 RS 485 a E Rename D Cancel Apply Click on Detect and the MAC address of the device s will appear in the table You must then use the IP address configuration tab to manually assign the IP address subnet mask and gateway Be aware that if the IP address that you give the device is not in the same IP range as the PC the device will no longer respond until you connect to it with a PC that is in the s
5. by entering the IP address in the Configuration screen Ping box Naming TCP IP Ethernet interfaces The rename button can be used to give an interface a meaningful name in the system This can be especially useful when more than one interface is used The name will appear in the doors screen within Net2 showing which ACU s are connected to which data line helping in any future fault finding process TCP IP Loopback test The following test should be run if there are problems setting up the IP configuration of the interface This test sends data to the device and checks this against the data it receives back This confirms that the network is working correctly The Net2 server program must be shut down during this test Remove any wires from the RS485 data line connector and create a hardwired data loop as follows Connect the Orange to White Green and Green to White Orange To run the test go to Net2 Server Config Utility TCP IP Nodes Advanced and click on Loopback test If the test fails connect the unit directly to the PC with an RJ45 patch cable and test it again Should this still fail please call Technical Support for further advice dala ee Electrical Tote O N o ie a SS r Environment Reu per gata Ime O TT ba amespere ooo o o O e O ethemet network spee omu woms OP ethernet bandwidth requirement O OOOO Sts dP DHCP support fixed IP recommendea O T w o Tasasi network speed OOOO o e operano temperature 0 se
6. lier Net2 software is not compatible with this unit If your PC can only support Net2 v3 software please contact Technical Support for further advice Apply power to the unit after connecting the RJ45 plug to a network point Page 1 The Net2 TCP IP Ethernet Interface allows a Net2 data line to be controlled from a PC running the Net2 Server across a TCP IP Ethernet network There is a 1 km maximum length for a data line This can be increased by using Net2 RS485 high speed repeaters 477 836 or by creating multiple data lines using several Ethernet connections controlled from the one PC The data line must be wired in a single daisy chain The data converter may be located anywhere along the data line 120 ohm terminating resistors must be linked across each data pair at the beginning AND end of the line This can be done on many units with a switch or jumpers If not free resistors are provided with the converter This unit has termination resistors that may be brought in circuit by means of a slide switch Termination switch ON Termination TCP IP Network LAN WAN PC running Net2 software og on 2 7 Termination Termination Page 2 When connecting to a LAN The IP address should be assigned a fixed value or should be given a DHCP reservation Unreserved IP addresses issued by DHCP servers are not guaranteed to be constant leading to potential failure of communication
7. ng you must check the IP address to make sure it is still in range with the PC or network If it is not you should either change the IP address of the PC or the IP address of the device so they are both again in the same range Our Technical team can talk you through this if you need help If the MAC address does not appear when you click Detect ensure that the following ports are open on all devices between this unit and the Net2 PC If you still cannot detect the MAC address of the device call our Technical Support Help line Connecting to a WAN or different subnet mask If you are connecting this device to a remote subnet which is different from the Net2 software PC the standard detect mechanism cannot work across the network routers between them The IP address along with the correct Subnet mask and gateway for the remote subnet have to be set Either do this on the local subnet with the existing Net2 PC or use a PC on the remote subnet once the device is installed The PC that has the Net2 server installed must be able to access the IP address range on the WAN remote site This may require the routers and gateways to be configured between the networks Again this would be done by the Network administrator of that site Make sure the ports listed above are open on all intermediate routers Once installed create a record with the Add button if none was created during initial set up and you should then be able to detect its MAC