1. UI RA TRIPPLITE ST or T7 a E Instrucciones Importantes de Seguridad 14 Caracteristicas 20 Instalaci n R pida 15 Reemplazo de Bater a 21 Operaci n B sica 16 Almacenamiento y Servicio 22 Encendido Apagado del UPS 16 Registro de Garant a 23 Pantalla LCD 17 Informa de las Condiciones de English 1 Energia UPS 18 Fran ais 25 Activar Desactivar Alarma 18 Auto diagn stico 19 Mensajes de Error 19 E C e POWER PROTECTION Ex lendaen 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2012 Tripp Lite Todos los derechos reservados SmartPro es una marca registrada de Tripp Lite 12 12 069 93 327C indb 13 12 6 2012 9 28 47 AM Instrucciones Importantes de Seguridad GUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones y advertencias que deben seguirse durante la instalaci n operaci n y almacenamiento de este producto La omisi n en la o
2. RN NM Ts AMA 5 Branchez les nouvelles batteries exactement de la m me 6 R installez la barre de support des batteries et remontez le mani re que les vieilles connecteurs positifs rouges ensemble panneau avant et connecteurs n gatifs noirs ensemble Glissez les batteries avec soin dans le syst me d alimentation sans coupure UPS Ts AAR 12 12 069 93 327C indb 33 12 6 2012 9 29 13 AM Entreposage et entretien Entreposage Pour viter la d charge des batteries tout l quipement branch devrait tre commut hors tension OFF et d branch du syst me d alimentation sans coupure UPS Pressez et maintenir le bouton POWER ALIMENTATION pendant une seconde et d branchez l unit de l alimentation CA Votre syst me d alimentation sans coupure UPS sera compl tement d sactiv et sera pr t pour l entreposage Si vous planifiez entreposer votre
3. CR po 4 6 Reinstall the battery support bar and replace the front panel 5 Connect the new batteries in exactly the same manner as the old ones positive red connectors together and negative black connectors together Carefully push the batteries back into the UPS St AR 12 6 2012 9 28 42 AM 12 12 069 93 327C indb 9 Storage and Service Storage To avoid battery drain all connected equipment should be turned off and disconnected from the UPS Press and hold the POWER QD BUTTON for one second and disconnect the unit from AC power Your UPS will be completely turned off deactivated and will be ready for storage If you plan on storing your UPS for an extended period fully recharge the UPS batteries every three months Plug the UPS into a live AC outlet turn it on by pressing and holding the POWER 0 BUTTON for one second and allow the batteries to recharge for 4 to 6 hours If you leave your UPS batteries discharged for a long period of time they will suffer a permanent loss of capacity Service A variety of Extended Warranty and On Site Service Programs are available f
4. LT je J E AAA le gt __ EZ EEE gt gt gt UA gt gt gt ES EEE a EEE EES SSE 2 EE EE 2 gt ES EEF Ml SS Saque con cuidado las bater as viejas del UPS y descon ctelas AY AN JE E Q AAA TE CR A
5. 6 Reinstale la barra de soporte de la bater a y recoloque el panel 5 Conecte las bater as nuevas exactamente en la misma forma en que estaban las anteriores conectores positivos rojo frontal juntos y conectores negativos negro juntos Empuje con cuidado las bater as dentro del UPS St AR 21 12 6 2012 9 28 59 AM 12 12 069 93 327C indb 21 Almacenamiento y Servicio Almacenamiento Para evitar descarga de la bateria todo el equipo conectado debe apagarse y desconectarse del UPS Oprima y mantenga el BOTON POWER durante un segundo y desconecte la unidad de la energia de CA Su UPS se apagara completamente desactivado y estara listo para almacenamiento Si planea almacenar su UPS por un periodo prolongado recargue completamente las baterias del UPS cada tres meses Enchufe el UPS en un tomacorriente activo de CA enci ndalo oprimiendo y manteniendo el BOTON POWER y durante un segundo y permita que las bater as recarguen por 4 a 6 horas Si deja las bater as de su UPS descargadas por un per odo prolongado de tiempo sufrir n una p rdida permanente de capacidad Servicio Tripp Lite tiene disponible una variedad de Programas de Garant a Extendida y Servicio En Sitio Para informaci n adicional acerca del servicio visite www tripplite com
6. Optional Installation All models include USB communication ports tel DSL Ethernet Not compatible with PoE applications surge protection jacks and coaxial line protection jacks These connections are optional the UPS will work properly without these connections See the connector s description in the Basic Operation section for connection instructions If the LINE POWER icon does not illuminate when the UPS is turned ON try the following 1 Make sure that the UPS is plugged into a live AC outlet 2 Press and hold the POWER BUTTON for one second to turn on the UPS A beep should sound when the UPS starts 3 Ifthe UPS still does not start contact Tripp Lite Tech Support for assistance 12 12 069 93 327C indb 3 i NO T N S jun PR l Ty Uii lA FAX PHONE LA SURGE PROTECT AA KOSS Q _ 12 6 2012 9 28 35 AM Basic Operation UPS ON OFF e Plug the UPS into a live grounded outlet The LCD display will illuminate the battery charger will engage as necessary and the SURGE PROTECTED outlets will begin passing power e Plug equipment into the UPS Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment you connect to the Battery Surge and Noise Protected outlets exceed the UPS s Output Capacity To estimate your
7. F LCDT Series UPS Systems Models SMART1500LCDT OMNI1500LCDT SMART1300LCDT AG 0066 AG 0067 AG 0068 HANNA RA TRIPPLITE ST TT ATA Important Safety Instructions 2 Features 8 Quick Installation 3 Battery Replacement 9 Basic Operation a Storage and Service 10 UPS On Off Warranty Registration 11 LCD Display 5 Display UPS Power Conditions 6 Espanol 13 Enable Disable Alarm 6 mangas 25 Self Test T Error Messages POWER PROTECTION Manufacturing Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2012 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite 12 12 069 93 327C indb 1 12 6 2012 9 28 34 AM Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the install
8. 1 800 822 8837 www rbrc com Tripp Lite ofrece una l nea completa de Cartuchos de reemplazo de bater a para UPS R B C Visite Tripp Lite en la web en www tripplite com support battery index cfm para localizar la bater a de reemplazo espec fica para su UPS 14 12 12 069 93 327C indb 14 12 6 2012 9 28 48 AM Instalacion Rapida PASO 1 Conecte el UPS en un tomacorriente correctamente conectado a tierra Despu s de enchufar el UPS en un tomacorriente de pared oprima y mantenga el BOTON POWER W durante un segundo para encender el UPS Ver la Secci n de Operaci n Basica Nota El UPS no encender autom ticamente en presencia de energ a activa de alimentaci n de la red PASO 2 Enchufe su equipo en el UPS Existen dos juegos de tomacorrientes en la parte posterior de su UPS Los tomacorrientes marcados SURGE PROTECTED no proporcionan energ a respaldada por bater a durante apagones Conecte a estos tomacorrientes los aparatos comunes de escritorio como impresoras esc neres y otros accesorios que no requieran Per por bateria Los tomacorrientes marcados BATTERY SURGE PROTECTED 5 ofrecen respaldo por bater a durante fallas de energ a Conecte sus equipos vitales de computo en estos tomacorrientes Su UPS est dise ado para respaldar solamente equipo electr nico Usted sobrecargar el C FARPHONEICA UPS si las especificaciones totales de VA para todo e
9. Le num ro de s rie ne doit pas tre confondu avec le nom de la marque ou le num ro de mod le du produit Tripp Lite respecte une politique d am lioration constante Les sp cifications du produit sont sujettes changement sans pr avis TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Droits d auteur 2012 Tripp Lite Tous droits r serv s _ SmartPro est une marque d pos e de Tripp Lite 12 10 241 93 327C_revC 12 12 069 93 327C indb 36 12 6 2012 9 29 14 AM
10. tre remplac es 12 12 069 93 327C indb 29 E lt BOOST ON LINE AVR bl Uh l i II i A 1080 amp tons RUNTIME ESTIMATE FAULT INDICATEURS DES BATTERIES Lindicateur BATTERY CHARGE CHARGE DES BATTERIES rapporte continuellement le niveau de la charge des batteries Lindicateur LOAD LEVEL NIVEAU DE LA CHARGE rapporte continuellement le niveau de la charge branch e aux prises support es du systeme d alimentation sans coupure UPS Lic ne OVERLOAD SURCHARGE s allume pour rapporter que les prises support es du syst me d alimentation sans coupure UPS sont surcharg es AUTRES AFFICHAGES Affichage a 3 chiffres s allume avec l tiquetage et les ic nes associ s pour rapporter une vari t de conditions reli es au syst me d alimentation sans coupure UPS et l alimentation du site Affichage a 3 chiffres suffixe tiquettes de l affichage s allume de mani re s lective pour d crire l unit de mesure de l affichage 3 chiffres pr sentement rapport V volts pourcentage amp res KW kilowatts Hz fr quence Min minutes Affichage 3 chiffres pr fixes Les voyants lumineux INPUT ENTR E s allument pour indiquer que l affichage 3 chiffres rapporte une condition de l alimentation d entr e tension de l entr e fr quence de l entr e Les voyants lumineux OUTPUT SORTIE s allum
11. REEMPLAZO DE BATER A PANTALLA LCD DE SOBRECARGA gt BATTERY sa ON LINE p ni V ON LINE Ba CE our REPLACE D BATTERY LOAD BATTERY LOAD 29 CARD En el caso de que la bater a del UPS requiera reemplazo se Si existe una sobrecarga se encender n los conos Loan Y y la encender e cono 2 Reemplace la bater a del UPS para pantalla LCD informar el porcentaje de carga de salida restablecer el indicador de reemplazo de bater a PANTALLAS DE FALLA CR TICA Algunas condiciones de falla m s severas haran que el UPS corte la energ a a los tomacorrientes soportados por el UPS En este punto la pantalla LCD informar cualquiera de 5 c digos de falla en pantalla Algunas fallas como un corto circuito en la salida sobrecarga y bater a mala pueden ser corregidas por el usuario eliminando el corto reduciendo la carga o reemplazando la bater a Algunas condiciones de falla que involucren al cargador de la bater a y al voltaje de salida pueden requerir reparaci n o reemplazo a fin de restablecer la operaci n normal Si ocurre una falla cr tica la pantalla LCD mostrar los siguientes c digos de error 1 OUTPUT SHORT CIRCUIT OUTPUT CUTOFF corto circuito de 3 BATTERY OVERCHARGE sobrecarga de la bater a salida corte de salida e Consulte con Tripp Lite las opciones de soluci n de e Para borrar desconecte el origen del corto circuito de la problemas y reparaciones salida y r
12. TENSION DES BATTERIES Po ouput El 7 fo outeuT 8 7 BATTERY e 7 Ef 0 LO OL Oe O ca OO gt li VD E Jf 110 Activer d sactiver l alarme Pour passer en mode silence appuyez sur le bouton note _ jusqu l audition d un signal sonore Lic ne MUTE sera affich e l cran ACL pour indiquer que l appareil est en mode silence Pour quitter le mode silence appuyez sur le bouton me jusqu a l audition d un signal sonore l ic ne sez disparaitra de l cran ACL pour indiquer que l appareil n est plus en mode silence Remarque Le mode silence ne peut tre s lectionn que lorsque l appareil est en ligne Le mode silence d sactive compl tement l avertisseur Pour passer temporairement en mode silence lorsque l appareil fonctionne sur piles appuyer et maintenir enfonc le bouton nite jusqu a ce Af 7 Y yA que sr clignote a l cran ACL pour indiquer que l avertisseur est temporairement d sactiv Remarque L avertisseur de faiblesse des piles se fera entendre m me si l avertisseur a t temporairement d sactiv 12 12 069 93 327C indb 30 12 6 2012 9 29 07 AM Fonctionnement de base sut Autotest Pressez et retenez le rsr bouton pour initier le test Le test durera environ 10 secondes pendant que le syst me d alimentation sans coupure UPS commute aux batteries pour v rifier leur capacit sous charge la fin du test le syst me d
13. alimentation sans coupure UPS retournera au mode d alimentation du secteur Si le test choue l cran affichera l ic ne BI et l alarme se fera entendre Si ceci REPLACE survient chargez les batteries pendant 12 heures et r p tez l autotest Si une autre panne existe contactez Tripp Lite pour conna tre les options de remplacement des batteries Si le syst me d alimentation sans coupure UPS r ussit l autotest ACL affichera PAS l quipement peut demeurer branch pendant l autotest Ne d branchez pas votre syst me d alimentation sans coupure UPS puisque ceci couperait la mise au sol s curitaire Messages d erreurs Le syst me d alimentation sans coupure UPS rapporte les tats BATTERY REPLACEMENT REMPLACEMENT DES BATTERIES et OVERLOAD SURCHARGE au moyen de les ic nes lt et Le 5 CRAN BATTERY REPLACEMENT REMPLACEMENT DES CRAN OVERLOAD SURCHARGE DE LACL BATTERIES DE LACL OUTPUT Seen rI ON LINE gt m V gt 101 lt i Li o Bo LL SS ee BATTERY Loan LO Pore BATTERY LOAD S a Si une surcharge existe les ic nes toad Et S allumeront et Dans le cas o les batteries du syst me d alimentation sans coupure ACL rapportera le pourcentage de charge de la sortie UPS n cessitent d tre remplac es l ic n s allumeront Remplacez les batteries du syst me d alimentation sans coupure UPS pour r initialiser l indicateur du remplacement d
14. d alimentation sans coupure UPS offre la compatibilit de base avec la plupart des applications de gestion d alimentation int gr es Windows Macintosh et Linux 7 Prises SURGE SUPPRESSION ONLY SUPPRESSION DE SURTENSION SEULEMENT Ces prises de courant offrent une suppression de surtension de haute qualit pour les accessoires qui ne requi rent pas le support de l alimentation de secours des batteries Ces prises de courant sont toujours actives lorsque le syst me d alimentation sans coupure UPS est branch a une prise sous tension m me si le syst me d alimentation sans coupure UPS est arr t OFF 8 Prises de courant BATTERY BACKUP ALIMENTATION DE SECOURS BATTERIES Ces prises offrent l alimentation de secours partir des batteries et une suppression des surtensions de haute qualit pour les appareils critiques n cessitant le support de l alimentation de secours des batteries Remarque Ne branchez pas les imprimantes laser ces prises 9 Disjoncteur r armable du circuit d entr e Prot ge votre circuit lectrique des surintensit s caus es par la charge du syst me d alimentation sans coupure UPS Si ce disjoncteur est d clench d branchez une partie de la charge puis r armez le en le pressant sa position normale 32 12 12 069 93 327Cindb 32 12 6 2012 9 29 09 AM Remplacement des batteries Dans des conditions normales les batteries originales de votre syst me d alimentation sans coup
15. des deux conditions suivantes 1 Cet appareil ne peut causer aucune perturbation dommageable et 2 cet appareil doit accepter toute perturbation re ue incluant la perturbation pouvant causer un fonctionnement non souhaite Remarque Cet quipement a t test et trouv conforme aux restrictions applicables un appareil num rique de classe A conform ment la partie 15 des r glements de la FCC Ces restrictions sont con ues pour assurer une protection raisonnable contre les perturbations nuisibles dans une installation r sidentielle Cet quipement g n re utilise et peut radier de l nergie radiofr quence et s il n est pas install et utilis en conformit avec les instructions peut causer des perturbations nuisibles aux communications radio Cependant aucune garantie n existe que des perturbations ne surviendront pas dans une installation donn e Si cet quipement cause des perturbations nuisibles la r ception des signaux radio et de t l vision ce qui peut tre d termin en fermant et en ouvrant ON OFF l quipement nous recommandons l utilisateur de tenter d liminer les perturbations en prenant une et plusieurs des mesures suivantes e R orientez ou repositionnez l antenne r ceptrice e Augmentez la distance entre l quipement et le r cepteur e Branchez l quipement une prise sur un circuit diff rent de celui sur lequel le r cepteur est branch e Consultez votre fournisseur ou un techn
16. equipment s power requirements look on the nameplate If the equipment is listed in amps multiply the number of amps by 120 to determine VA Example 1 amp x 120 120 VA Your UPS is fully loaded when the display indicates 100 load e Turn the UPS on Press and hold the POWER BUTTON for one second The UPS alarm will beep once briefly The BATTERY SURGE PROTECTED outlets will begin passing AC line power The UPS will automatically recharge internal batteries as needed Once turned on your UPS is ready to protect connected equipment from blackouts brownouts overvoltages and transient surges e Turn the UPS off Press and hold the POWER O BUTTON for one second 12 12 069 93 327C indb 4 12 6 2012 9 28 35 AM Basic Operation continues LCD Display The LCD Display indicates a variety of UPS modes and operating conditions To view the various screens press the wore button while the UPS is operating in line or battery power mode The LCD DISPLAY is shown here fully illuminated to identify all available icons and labels This is for explanation only there are no operating modes where the screen is fully illuminated like this except for a few seconds as the UPS is first plugged in OPERATING MODE INDICATORS ON LINE MODE ICON indicates that AC power is present and the UPS is running from an input line power source AVR BUCK amp AVR BOOST ICONS will selectively illuminate during line power mode to indicate Autom
17. me d alimentation sans coupure UPS 5 OUTPUT VOLTAGE HIGH IN BATTERY MODE TENSION DE SORTIE ELEVEE DANS LE MODE BATTERIES e Contactez Tripp Lite pour conna tre les options ded pannage et de r paration 31 12 12 069 93 327C indb 31 12 6 2012 9 29 09 AM Caract ristiques Caract ristiques du syst me d alimentation sans coupure UPS AANA SURGE PUAPTECTED liiy ij FAX PHONE LAN SURGE PROTECTION N 4 YO eO OUT VA CABLE VIDEO Ma SURGE PROTECTION E 1 Bouton ON OFF MARCHE ARR T Pressez et maintenir pendant une seconde pour mettre le syst me d alimentation sans coupure UPS en marche presses et maintenir de nouveau pour l arr ter Si l alimentation du secteur n est pas disponible la pression de ce bouton activera le d marrage froid du syst me d alimentation sans coupure UPS c est dire le mettra en marche et fournira l alimentation aux prises de sortie partir des batteries 2 Bouton MUTE Select Utilisez ce bouton pour permuter l affichage des tats de l alimentation R f rez vous la section Affichage des tats de l alimentation pour une description d taill e Ce bouton peut aussi tre utilis pour mettre l appareil en mode silence d sactiver compl tement l avertisseur ou pour mettre temporairement en sourdine une alarme active en pressant et en retenant le bouton l ic ne de sourdine clignotera l cran ACL pour indiquer que l avertisseur es
18. n siempre energizados cuando el UPS est conectado a un tomacorrientes activo a n si el UPS est apagado 8 Tomacorrientes etiquetados BATTERY BACKUP Estos tomacorrientes ofrecen soporte de respaldo por bater a y supresi n premium de sobretensiones para dispositivos cr ticos que requieran soporte de respaldo por bater a Nota No enchufe impresoras l ser en los tomacorrientes respaldados por bater a 9 Braker del Circuito de Alimentaci n Protege su circuito el ctrico contra demanda de sobrecorriente de la carga del UPS Si este breaker se dispara retire algo de la carga despu s reestabl zcalo oprimi ndolo 20 12 12 069 93 327C indb 20 12 6 2012 9 28 54 AM Reemplazo de la Bateria Bajo condiciones normales la bater a original en su UPS durar varios a os El reemplazo de la bater a deber realizarlo s lo personal calificado Para informaci n completa de seguridad de las bater as consulte Advertencias de Bater a en la secci n de Seguridad Su UPS requiere dos cartuchos de bater a de repuesto RBC51 de Tripp Lite Para informaci n adicional acerca de compatibilidad y compra de repuestos visite Tripp Lite en la Web en www tripplite con support battery index cfm Para Reemplazar las bater as 1 Retire el tornillo en la parte inferior del panel frontal de la unidad Jale con cuidado el panel frontal del UPS a WK
19. ne fournissent pas l alimentation de secours des batteries lors des pannes d lectricit Branchez les p riph riques informatiques ordinaires comme les imprimantes les numeriseurs et les autres accessoires ne n cessitant pas l alimentation de secours des batteries ces prises de courant Ca O AN LU I NN SER Les prises de courant identifiees BATTERY SURGE PROTECTED BATTERIE PROTEGEES ea CTO Cae NL X gt CONTRE LES SURTENSIONS 7 offrent le soutien des batteries du syst me d alimentation oN P sans coupure UPS lors des coupures de courant Branchez votre quipement informatique vital ces prises de courant Ai FAX PHONE LA SURGE PROTECT Votre syst me d alimentation sans coupure UPS est con u pour supporter uniquement l quipement lectronique Vous surchargerez le syst me d alimentation sans coupure UPS si la valeur VA nominale de tous les quipements branch s aux prises de courant identifi es BATTERY SURGE PROTECTED BATTERIE PROT G ES CONTRE LES SURTENSIONS exc de la capacit de sortie du syst me d alimentation sans coupure UPS Pour conna tre la valeur VA nominale de vos quipements v rifiez leurs plaques signal tiques Si la seule valeur indiqu e est en amperes multipliez le nombre d amp res par 120 pour d terminer la valeur VA Par exemple 1 ampere x 120 120 VA Si vous croyez que vous avez surcharg les prises de courant v rifiez les crans Lo
20. para proteger el equipo conectado contra apagones reducciones de voltaje sobrevoltajes y sobretensiones transitorias e Apague el UPS Oprima y mantenga el BOT N POWER durante un segundo nuevamente 16 12 12 069 93 327C indb 16 12 6 2012 9 28 49 AM Operacion Basica continuacion Pantalla LCD La pantalla LCD indica una variedad de modos y condiciones de operaci n del UPS Para ver las diversas pantallas oprima el bot n sit mientras el UPS est operando en modo en l nea o respaldado por bater a Aqui se muestra la PANTALLA LCD completamente iluminada para identificar todos los conos y etiquetas disponibles Esto es s lo para explicaci n no existen modos de operaci n en que la pantalla est completamente iluminada como esta excepto por algunos segundos cuando se enchufa inicialmente el UPS INDICADORES DE MODO DE OPERACI N CONO DE MODO EN L NEA indica que hay alimentaci n de CA y el UPS est funcionando desde una entrada de energ a de l nea CONOS AVR BUCK Y AVR BOOST se iluminaran selectivamente durante el modo de alimentaci n de l nea para indicar que est activa la Regulaci n Autom tica de Voltaje AVR AVR y BUCK indica una condici n de sobrevoltaje y la salida se reduce para regresarla a niveles utilizables AVR y BOOST indica condiciones de voltaje reducido y la salida es reforzada para regresarla a niveles utilizables CONO ON BATT indica que el UP
21. s de las medidas siguientes e Reoriente o reubique la antena receptora e Aumente la separaci n entre el equipo y el receptor e Conecte el equipo en un tomacorriente de un circuito diferente del que tiene conectado al receptor e Consulte al distribuidor o un t cnico experimentado en radio TV Cualquier cambio o modificaci n a este equipo que no est aprobado expresamente por Tripp Lite podr a invalidad la autoridad del usuario para operar este equipo 23 12 12 069 93 327C indb 23 12 6 2012 9 29 00 AM Registro de Garant a continuaci n Limitaciones de Acoplamiento del Equipo modelos con la etiqueta de Industry Canada solamente en Canad AVISO La etiqueta Industry Canada identifica un equipo certificado Esta certificaci n significa que el equipo cumple los requerimientos de protecci n de red de telecomunicaciones de operaci n y seguridad seg n est prescrito en el los Documento s adecuado s de Requerimientos T cnicos de Equipo Terminal El Departamento no garantiza que el equipo trabajar a satisfacci n del usuario Antes de instalar este equipo los usuarios deben garantizar que est permitido conectarse a las instalaciones de la compa a local de telecomunicaciones El equipo debe adem s instalarse usando un m todo de conexi n aceptable El usuario debe estar advertido de que el cumplimiento de las condiciones anteriores puede no evitar la degradaci n del servicio en algunas situaciones Las reparaciones
22. support Antes de regresar su producto para servicio siga estos pasos 1 Revise los procedimientos de instalaci n y operaci n descritos en este manual para asegurarse de que el problema de servicio no se origina por una mala lectura de las instrucciones 2 Si el problema contin a no se ponga en contacto ni regrese el producto al distribuidor En vez de eso visite www tripplite com support Si el problema requiere servicio visite www tripplite com support y haga click en el enlace Product Returns devoluciones de producto Desde aqu puede solicitar un n mero de Autorizaci n para Devoluci n de Mercanc a RMA que es necesario para servicio Este sencillo formato en l nea le solicitar los n meros de modelo y serie de su unidad junto con otra informaci n general del comprador Se enviar n a su correo electr nico el n mero RMA y las instrucciones de embarque Cualquier da o directo indirecto especial o consecuente al producto ocurrido durante el embarque a Tripp Lite o un centro de servicio autorizado de Tripp Lite no est cubierto por la garant a Los productos embarcados a Tripp Lite o un centro de servicio autorizado de Tripp Lite deben tener los gastos de transportaci n prepagados Marque el n mero RMA en el exterior del paquete Si el producto est dentro del per odo de garant a incluya una copia de su comprobante de compra Regrese el producto para servicio usando un transportador aseguradio a la direcci n proporcio
23. 3 Siel UPS a n no arranca p ngase en contacto con Soporte T cnico de Tripp Lite para solicitar ayuda 15 12 12 069 93 327C indb 15 12 6 2012 9 28 49 AM Operacion Basica Encendido Apagado del UPS e Enchufe el UPS en un tomacorriente activo conectado a tierra Se encender la pantalla LCD el cargador de la bater a se activar seg n se necesite y los tomacorrientes protegidos contra sobretensiones SURGE PROTECTED empezar n a conducir energ a e Enchufe el equipo en el UPS Su UPS est dise ado para respaldar solamente equipo electr nico Usted sobrecargar el UPS si las especificaciones totales de VA para todo el equipo que conecte a los tomacorrientes marcados BATTERY SURGE PROTECTED respaldados por bater a protegidos contra ruido y sobretensiones exceden la capacidad de salida del UPS Para estimar los requerimientos de potencia de su equipo consulte la placa de identificaci n Si el equipo est especificado en amperes multiplique el n mero de amperes por 120 para determinar los VA Ejemplo 1 amp x 120 120 VA Su UPS est totalmente cargado cuando la pantalla indique 100 de carga e Encienda el UPS Oprima y mantenga el BOT N POWER durante un segundo La alarma del UPS emitir un breve bip Los tomacorrientes marcados BATTERY SURGE PROTECTED empezar n a conducir energ a de CA El UPS empezar a recargar autom ticamente las bater as internas seg n sea necesario Una vez encendido su UPS est listo
24. ER A Ar Sr O eh ON LINE L tp 6 r TO ON LINE l 6 j TiO ON LINE l l TiO O p aa pe Informaci n del LCD del Modo de Alimentaci n de Bater a La pantalla LCD ofrece 6 pantallas de informaci n del UPS y energ a del sitio mientras el UPS est operando en modo de alimentaci n por bater a Cuando el UPS conmute al MODO POR BATER A el LCD conmutar autom ticamente para informar la AUTONOM A ESTIMADA Para avanzar a la pantalla siguiente oprima el bot n woe Las pantallas se muestran en este orden 1 AUTONOMIA ESTIMADA 2 VOLTAJE DE SALIDA 3 FRECUENCIA DE SALIDA Poo ourrur MN 7 __oureur FE 7 f __oureur EN 7 E jz cay Mos te IO ss EE OU BATTERY LOAD BATTERY LOAD BATTERY LOAD NTE ss A O PORCIENTO DE CARGA DE SALIDA 5 POTENCIA EN WATTS DE CARGA DE SALIDA 6 VOLTAJE DE BATER A Po ouput El E Po outeur E Po BATTERY Gi a Zo oO EQU O LS TC ap a e ua as am 23 ou gt SB Jat VE CIO 12 12 069 93 327C indb 18 Activar Desactivar Alarma Para ingresar al modo silencioso oprima y sostenga el bot n we hasta que escuche un bip El cono mr aparecer en la pantalla LCD para indicar que la unidad est en modo silencioso Para salir del modo silencioso oprima y sostenga el bot n we hasta que escuche un bip El icono mz desaparecer de la pantalla LCD pa
25. IL BATTERY LOAD ma 5 INPUT VOLTAGE a INPUT 1 101 JL Lol p _ _ AAA oureur MM ort ET j OLS 4 OUTPUT LOAD PERCENTAGE Po OUTPUT 4 D DL Enable Disable Alarm 2 OUPUT VOLTAGE E II IL Li BATTERY LOAD a 5 OUTPUT LOAD WATTS Tos Gr all gt DL LY BATTERY LOAD aa a _ MUTE 1 MUTE 3 OUTPUT LOAD PERCENT a iL 01 A Li Ld BATTERY aa LOAD a OUTPUT E 6 BATTERY VOLTAGE gt gt y onLine 6 BATTERY anal LOAD a 3 OUTPUT FREQUENCY ES gt y Er amp j 4 BATTERY aa IL LOAD a OUTPUT 2 6 BATTERY VOLTAGE BATTERY JLo j CAC LOAD U ON BATT GD BATTERY aa a To enter silent mode press and hold the we button until you hear an audible beep The icon will appear on the LCD screen to indicate the unit is in silent mode To exit silent mode press and hold the button until you hear an audible beep The icon will disappear from the LCD screen to indicate it s no longerin silent mode Note Silent mode can only be selected while the unit is in online mode Silent mode will deactivate the beeper completely To temporarily mute the alarm while the unit is in batte
26. LCD el icono mute Bot n TEST Oprima y sostenga este bot n y el UPS empezar un Auto diagn stico que dura unos 10 segundos 4 Enchufes de Protecci n de L nea de Tel DSL RED Estos enchufes protegen el equipo contra sobretensiones sobre a una sola l nea telef nica o conexi n de red La conexi n de sus equipos a estos conectores es opcional Su UPS trabajar correctamente sin esta conexi n 5 Enchufes de Protecci n de Linea Coaxial Estos enchufes protegen al equipo contra sobretensiones sobre linea coaxial La conexi n de sus equipos a estos enchufes es opcional Su UPS trabajar correctamente sin esta conexi n 6 Puerto de Comunicaci n USB Este puerto puede conectar su UPS a cualquier computadora para el guardado autom tico de archivos y apagado sin supervisi n en caso de una falla de energ a Use con el Software PowerAlert de Tripp Lite disponible como descarga GRATUITA en www tripplite com y un cable USB adecuado Se incluye un cable USB con su UPS Esta conexi n es opcional Su UPS trabajar correctamente sin esta conexi n Nota Este Sistema UPS proporciona compatibilidad de comunicaci n b sica con la mayor a de las aplicaciones de administraci n de energ a integradas de Windows Macintosh y Linux 7 Tomacorrientes etiquetados SURGE SUPPRESSION ONLY Estos tomacorrientes ofrecen supresi n premium de sobretensiones para accesorios que no requieran soporte de respaldo por bater a Estos tomacorrientes est
27. N OFF Button Press and hold the POWER BUTTON for one second to turn the UPS on and off If utility power is not available pressing this button will cold start the UPS i e turn it on and supply battery derived power to the outlets 2 MUTE Select Button Use this button to toggle power condition displays Refer to Display UPS Power Conditions section for details This button can also be used to place the unit in silent mode mute the beeper completely or to temporarily mute an active alarm by pressing and holding the button until the mute icon flashes on the LCD screen 3 TEST Button Press and hold this button and the UPS will begin a self test lasting about 10 seconds 4 Tel DSL NETWORK Line Protection Jacks These jacks protect equipment against surges over a single phone line or network connection Connecting your equipment to these jacks is optional Your UPS will work properly withoutthis connection 5 Coaxial Line Protection Jacks These jacks protect equipment against surges over coaxial line Connecting your equipment to these jacks is optional Your UPS will work properly withoutthis connection 6 USB Communication Port This port can connect your UPS to any computer for automatic file saves and unattended shutdown in the event of a power failure Use with Tripp Lite s PowerAlert Software available as a FREE download at www tripplite com and appropriate USB cable A USB cable is included with your UPS This connection is op
28. S est funcionando en modo de bater a debido a falla de energ a o fluctuaci n severa del voltaje de entrada CONO REPLACE BATTERY se encender para informar a los usuarios que la bater a est d bil y requiere reemplazo 12 12 069 93 327C indb 17 E lt BOOST ON LINE AVR OVER DA LOAD 209 LOAD RUNTIME ESTIMATE FAULT MTT INDICADORES DE BATER A MEDIDOR DE CARGA DE BATER A informa continuamente el nivel de carga de la bater a MEDIDOR DE NIVEL DE CARGA informa continuamente el nivel de carga en los tomacorrientes respaldados por el UPS CONO DE SOBRECARGA se enciende para informar que los tomacorrientes respaldados del UPS est n sobrecargados PUNTOS ADICIONALES EN PANTALLA PANTALLA DE 3 D GITOS se ilumina junto con el etiquetado e conos asociados para informar una variedad de condiciones relativas al UPS y la energ a del sitio SUFIJO DE LA PANTALLA DE 3 D GITOS las etiquetas de la pantalla se iluminar n selectivamente para describir la unidad de medici n que la pantalla de 3 d gitos est mostrando actualmente V volts porcentaje A amperes kW kilowatts Hz frecuencia Min minutos PREFIJOS DE LA PANTALLA DE 3 D GITOS e INPUT entrada se enciende para indicar que la pantalla de 3 d gitos est informando una condici n de entrada voltaje de entrada frecuencia de entrada OUTPUT salida se enciende para indica
29. a gt y dual gt y ON LINE l 6 MUTE ON LINE ER 6 MUTE O ON LINE L 6 7 MUTE peu LU LS E IL aa a aa ue mal 4 WATTAGE DE LA CHARGE DE LA SORTIE 5 TENSION D ENTR E 6 TENSION DES BATTERIES a OUTPUT E a INPUT s gt BATTERY Gi ON LINE QQ E w TE O ON LINE 6 1 ro Y MUTE O ON LINE 1 1 m v MUTE O Da E g gt bE US Z LO aa aa mal p Donn es de l ACL dans le mode Battery Power Alimentation batteries L cran de l ACL offre 6 crans d information sur les alimentations du syst me d alimentation sans coupure UPS et du site lorsque le syst me d alimentation sans coupure UPS fonctionne dans le mode Battery Power Alimentation batteries Lorsque le syst me d alimentation sans coupure UPS commute au BATTERY MODE BATTERIES il passe automatiquement au rapport ESTIMATED RUNTIME TEMPS APPROX DE FONCTIONNEMENT Pour passer l cran suivant pressez le se _ bouton Les crans sont affich s dans l ordre suivant 1 TEMPS APPROXIMATIF DE FONCTIONNEMENT 2 TENSION DE SORTIE 4 DE LA CHARGE DE LA SORTIE 5 WATTAGE DE LA CHARGE DE LA SORTIE 3 FREQUENCE DE LA SORTIE QuTeUT Em 7 OUTPUT A E A OUTPUT E Ed ll Min gt E l LL os ER js BATTERY LOAD BATTERY LOAD BATTERY LOAD a nas aa ET 6
30. aciones que pueda hacer el usuario en la Protecci n de M dem Fax Este equipo no puede usarse en tel fonos de monedas proporcionados por la compa a telef nica La conexi n a l neas de terceros est sujeta a tarifas estatales Para informaci n p ngase en contacto con su comisi n estatal o corporaci n de servicios p blicos Aviso de FCC Clase A Este dispositivo es compatible con la parte 15 del reglamento de FCC La operaci n est sujeta a las dos condiciones siguientes 1 Este dispositivo puede causar interferencia da ina y 2 este dispositivo debe aceptar cualquier interferencia recibida incluyendo interferencia que pueda causar una operaci n indeseable Nota Este equipo ha sido probado y cumple con los l mites para un dispositivo digital clase A de acuerdo a la parte 15 del reglamento de FCC Estos l mites est n dise ados para proporcionar una protecci n razonable contra interferencia da ina en una instalaci n residencial Este equipo genera usa y puede radiar energ a de radiofrecuencia y si no se instala y usa de acuerdo con las instrucciones puede causar interferencia da ina a las radiocomunicaciones De cualquier modo no se garantiza que no ocurra esa interferencia en una instalaci n en particular Si este equipo causa interferencia da ina a la recepci n de radio o televisi n que pueda determinarse apagando y encendiendo el equipo se recomienda al usuario intentar corregir la interferencia mediante una o m
31. ad Percentage de charge et le Load Meter Indicateur de charge Voyez les descriptions de l affichage des conditions du syst me d alimentation sans coupure UPS de l alimentation dans la section Fonctionnement de base Si vous n tes toujours pas s r effectuez un autotest voyez la description de l autotest dans la section Fonctionnement de base Installation optionnelle Tous les mod les comportent des ports de communications USB des connecteurs prot g s contre les surtensions transitoires pour t l phone DSL Ethernet incompatibles pour les applications n cessitant l alimentation lectrique par les c bles Ethernet PoE et des connecteurs de protection pour c bles coaxiaux Ces connexions sont optionnelles le syst me d alimentation sans coupure UPS fonctionnera correctement sans ces connexions Voyez la description des connecteurs dans la section Fonctionnement de base pour les instructions pour les connections Si l ic ne LINE POWER ALIMENTATION DU SECTEUR ne s allume pas lorsque le syst me d alimentation sans coupure UPS est commut sous tension ON essayez ce qui suit 1 Assurez vous que le syst me d alimentation sans coupure UPS soit branch dans un prise de courant CA sous tension 2 Pressez et maintenir le bouton POWER ALIMENTATION pendant une seconde pour d marrer le syst me d alimentation sans coupure UPS Un bip devrait se faire entendre lorsque le syst me d alimentation s
32. al equipo certificado deben ser coordinadas por un representante designado por el proveedor Cualquier reparaci n o alteraci n hecha por el usuario a este equipo o mal funcionamiento del equipo pueden dar motivo a la compa a de telecomunicaciones para solicitar al usuario desconectar el equipo Los usuarios deben asegurar por su propia protecci n que s existe una conexi n el ctrica a tierra de las l neas de suministro el ctrico telefon a y la instalaci n hidr ulica met lica est n conectadas entre s Esta precauci n es particularmente importante en reas rurales Precauci n Los usuarios no deben intentar hacer las conexiones por s mismos pero deben ponerse en contacto con la autoridad el ctrica apropiada o un electricista seg n convenga No compatible con aplicaciones PoE Energ a sobre Ethernet Nota sobre el Etiquetado En la etiqueta se usan dos s mbolos V Voltaje de CA V Voltaje de CD N meros de Identificaci n de Compatibilidad con Reglamentos Para los fines de certificaciones e identificaci n de compatibilidad con reglamentos su producto Tripp Lite ha recibido un n mero de serie nico Se puede encontrar el n mero de serie en la etiqueta de identificaci n del producto junto con todas las marcas e informaci n requeridas Al solicitar informaci n de conformidad para este producto refiera siempre el n mero de serie El n mero de serie no debe confundirse con el nombre de marca o el n mero d
33. ans coupure UPS d marre 3 Si le syst me d alimentation sans coupure UPS ne d marre toujours pas communiquez avec les services techniques de Tripp Lite pour obtenir de l aide 27 12 12 069 93 327C indb 27 12 6 2012 9 29 05 AM Fonctionnement de base Commutation en hors tension On Off du syst me d alimentation sans coupure UPS e Branchez le syst me d alimentation sans coupure UPS a une prise de courant correctement mis la terre L ACLs allumera le chargeur de batterie s activera au besoin et les prises de courants identifi es SURGE PROTECTED PROTEGEES CONTRE LES SURTENSIONS seront sous tension e Branchez l quipement au syst me d alimentation sans coupure UPS Votre syst me d alimentation sans coupure UPS est con u pour supporter uniquement l quipement lectronique Vous surchargerez le syst me d alimentation sans coupure UPS si la valeur VA nominale de tous les quipements branch s aux prises de courant identifi es BATTERY SURGE PROTECTED BATTERIES PROTEGEES CONTRE LES SURTENSIONS exc de la capacit de sortie du syst me d alimentation sans coupure UPS Pour valuer les besoins en puissance voyez la plaque signal tique Si la seule valeur indiqu e sur l quipement est en amp res multipliez le nombre d amp res par 120 pour d terminer la valeur VA Exemple 1 ampere x 120 120 VA Votre syst me d alimentation sans coupure UPS est totalement charg lorsque
34. atic Voltage Regulation AVR is engaged AVR amp BUCK indicates an overvoltage condition and output is reduced back to usable levels AVR amp BOOST indicates brownout undervoltage conditions and output is boosted back to usable levels ON BATT ICON indicates that the UPS is running in battery mode due to power failure or severe input voltage fluctuation REPLACE BATTERY ICON will illuminate to inform users that the UPS battery is weak and requires replacement 12 12 069 93 327C indb 5 E lt BOOST ON LINE AVR A Loan LO RUNTIME ESTIMATE FAULT BATTERY INDICATORS BATTERY CHARGE METER continuously reports battery charge level LOAD LEVEL METER continuously reports load level on UPS supported outlets OVERLOAD ICON comes on to report that UPS supported outlets are overloaded ADDITIONAL DISPLAY ITEMS 3 DIGIT DISPLAY lights along with associated labeling and icons to report a variety of UPS and site power related conditions 3 DIGIT DISPLAY SUFFIX display labels will selectively illuminate to describe the unit of measurement the 3 digit display is currently reporting V volts percent A amps kW kilowatts Hz frequency Min minutes 3 DIGIT DISPLAY PREFIXES INPUT lights to indicate the 3 digit display is reporting an input condition input voltage input frequency OUTPUT lights to indicat
35. ation operation and storage of this product Failure to heed these warnings may affect the warranty UPS Location Warnings e Install your UPS indoors away from excess moisture or heat conductive contaminants dust or direct sunlight e For best performance keep the indoor temperature between 32 F and 104 F 0 C and 40 C e Leave adequate space around all sides of the UPS for proper ventilation e Only set the UPS upright on a sturdy flat surface Do not block fans or ventilation holes as this will seriously inhibit the unit s internal cooling and cause product damage not covered under warranty UPS Connection Warnings e Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS e Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection e Do not use extension cords to connect the UPS to an AC outlet e If the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output e The mains socket outlet that supplies the UPS should be easily accessible and located near the UPS Equipment Connection Warnings e Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equ
36. bservancia de estas advertencia puede afectar la garant a Advertencias de Ubicaci n de UPS e Instale su UPS en interiores alejado de humedad o calor excesivo contaminantes conductores polvo o luz solar directa e Para un mejor desempe o mantenga la temperatura interior entre 32 F y 104 F 0 C y 40 C e Para una ventilaci n adecuada deje un espacio adecuado alrededor de todos los lados del UPS e Coloque solamente al UPS en posici n vertical sobre una superficie plana y firme No bloquee los ventiladores u orificios de ventilaci n ya que eso inhibir seriamente el enfriamiento interno de la unidad y causar da o al producto no amparado por la garant a Advertencias de Conexi n del UPS e Conecte su UPS directamente a un tomacorrientes de pared de CA adecuadamente conectado a tierra No enchufe el UPS a si mismo esto da ar el UPS e No modifique la clavija del UPS y no use un adaptador que elimine la conexi n a tierra del UPS e No use cables de extensi n para conectar el UPS a un tomacorrientes de CA e Si el UPS recibe energ a de un generador de CA activado por un motor el generador debe proporcionar una salida limpia y filtrada de grado de computadora e El tomacorriente principal que alimenta al UPS debe ser f cilmente accesible y estar localizado pr ximo al UPS Advertencias de Conexi n del Equipo e No se recomienda el uso de este equipo en aplicaciones de soporte de vida en donde puede pensarse q
37. corporation commission for information FCC Notice Class A This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Any changes or modifications to this equipment not express
38. discontinuer temporairement ses services Si possible elle vous avisera l avance Si le pr avis n est pas possible vous serez avis le plus rapidement possible Vous serez avis de votre droit de porter plainte aupr s de la FCC Votre compagnie de t l phone peut apporter des changements ses installations exploitation ou proc dures pouvant affecter le fonctionnement normal de votre quipement Si tel est le cas vous serez avis l avance pour vous fournir l occasion de maintenir un service ininterrompu Si vous avez des troubles avec le syst me de protection du modem ou du t l copieur cet quipement veuillez visiter www tripplite com support pour obtenir des renseignements sur la r paration et la garantie La compagnie de t l phone peut vous demander de d brancher cet quipement du r seau jusqu ce que le probl me soit corrig ou que vous soyez convaincu que l quipement fonctionne correctement Aucune r paration ne peut tre effectu e par le client au syst me de protection du modem ou du t l copieur Cet quipement ne peut pas tre utilis sur le service payant offert par la compagnie de t l phone La connexion aux lignes partag es sous r serve des tarifs de l tat Contactez la Public Utility Commission ou la Corporation Commission de votre Ftat pour obtenir plus de renseignements Avis de la FCC classe A Ce dispositif est conforme la partie 15 des R glements de la FCC L utilisation sous r serve
39. e modelo del producto Tripp Lite sigue una pol tica de mejora continua Las especificaciones del producto est n sujetas a cambio sin previo aviso TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2012 Tripp Lite Todos los derechos reservados SmartPro es una marca registrada de Tripp Lite 12 12 069 93 327C indb 24 12 6 2012 9 29 00 AM Manuel de utilisateur Syst mes d alimentation sans coupure UPS de la s rie LCDT Mod les SMART1500LCDT OMNI1500LCDT SMART1300LCDT AG 0066 AG 0067 AG 0068 RARE A Consignes de s curit importantes 26 Activer d sactiver l alarme 30 Installation rapide 27 Autotest 31 Fonctionnement de base 28 Messages d erreurs 31 Commutation en hors tension On Off Caract ristiques 32 du syst me d alimentation sans Remplace
40. e the 3 digit display is reporting an output condition output voltage output Hz etc BATTERY lights to indicate the 3 digit display is reporting a battery related condition battery voltage ESTIMATED RUNTIME lights to indicate that the 3 digit display is currently reporting estimated runtime in minutes section for information on other reported faults FAULT ICON lights to indicate a variety of possible UPS fault conditions see Error Messages 12 6 2012 9 28 35 AM Basic Operation Display UPS Power Conditions Line Power Mode LCD Data The LCD screen offers 6 screens of UPS and site powerinformation as the UPS is operating in line power mode To advance to the next screen press the O button The screens are displayed in this order 1 OUTPUT VOLTAGE S _ oe ON LINE tt ILL a a 4 OUTPUT LOAD WATTAGE a OUTPUT EJ on LINE LL E 6 r IL ne Battery Power Mode LCD Data The LCD screen offers 6 screens of UPS and site power information as the UPS is operating in battery power mode When the UPS switches to BATTERY MODE the UPS will automatically switch to report ESTIMATED RUNTIME To advance to the next screen press the wie button The screens are displayed in this order 1 ESTIMATED RUNTIME BATTERY LOAD i NE El ESTIMATE 2 INPUT OUTPUT FREQUENCY OUTPUT 2 LA 35 INPUT ON LINE
41. ected together This precaution may be particularly important in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Not compatible with PoE Power over Ethernet applications Note on Labeling Two symbols are used on the label V AC Voltage V DC Voltage Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product Tripp Lite follows a policy of continuous improvement Product specifications are subject to change without notice TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2012 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite 12 12 069 93 327C indb 12 12 6 2012 9 28 43 AM Manual del Propietario Sistemas UPS Serie LCDT Modelos SMART1500LCDT OMNI1500LCDT SMART1300LCDT AG 0066 AG 0067 AG 0068
42. einicie el UPS 4 BAD AND SEVERELY DISCHARGED BATTERY bater a en mal 2 OUTPUT OVERLOAD OUTPUT CUTOFF sobrecarga de la salida estado y severamente descargada corte de la salida e Para borrar reemplace la bater a del UPS e Para borrar desconecte el origen de la sobrecarga y 5 OUTPUT VOLTAGE HIGH IN BATTERY MODE voltaje de salida reinicie el UPS alto en modo de bater a e Consulte con Tripp Lite las opciones de soluci n de problemas y reparaciones 19 12 12 069 93 327C indb 19 12 6 2012 9 28 53 AM Caracteristicas Caracteristicas del UPS BATTERY SURGE Y PROTECTED SURGE PO TECTED LEDS lt A LZ FAX PHONE LAN SURGE PROTECTION _ W IN K N OUT Z O CABLE VIDEO SURGE PROTECTION pH 1 Bot n ON OFF Oprima y mantenga durante un segundo para encender el UPS y oprima y mantenga nuevamente para apagarlo Si no hay disponible energ a de la red p blica al oprimir este bot n arrancar en fr o el UPS es decir enciende y suministra energ a derivada de la bater a a los tomacorrientes 2 Bot n MUTE Select Use este bot n para cambiar las pantallas de condiciones de energ a Para detalles refi rase a al secci n de Mostrar Condiciones de UPS Energ a Este bot n puede usarse tambi n para poner la unidad en modo silencioso silenciar completamente el biper o para silenciar temporalmente una alarma activa oprima y sostenga hasta que se destelle en la pantalla
43. ent pour indiquer que l affichage 3 chiffres rapporte une condition de l alimentation de sortie tension de sortie fr quence de sortie etc Le voyant lumineux BATTERY BATTERIES s allume pour indiquer que l affichage a 3 chiffres rapporte une condition reli e aux batteries tension des batteries Le voyant lumineux ESTIMATED RUNTIME TEMPS APPROXIMATIF DE FONCTIONNEMENT s allume pour indiquer que l affichage a 3 chiffres rapporte le temps approximatif de fonctionnement en minutes Lic ne FAULT PANNE s allume pour indiquer une vari t de conditions de pannes possibles voyez la section Messages d erreurs pour plus de renseignements sur d autres pannes rapport es 12 6 2012 9 29 06 AM Fonctionnement de base sut Affichez les tats du syst me d alimentation sans coupure UPS des alimentations Donn es de l ACL du mode Line Power Alimentation secteur ACL offre 6 crans d information sur les alimentations du syst me d alimentation sans coupure UPS et du site lorsque le syst me d alimentation sans coupure UPS fonctionne dans le mode Line Power Alimentation secteur Pour passer l cran suivant pressez le sw bouton Les crans sont affich s dans l ordre suivant 1 TENSION DE SORTIE 2 FR QUENCE ENTR E SORTIE 3 DE LA CHARGE DE LA SORTIE gt a OUTPUT Et sa INPUT OUTPUT 2 sa OUTPUT E E gt y
44. es batteries CRANS DES PANNES CRITIQUES Certains tats de pannes plus s v res causeront la coupure de l alimentation aux prises de courant support es par le syst me d alimentation sans coupure UPS Dans ce cas l cran de l ACL affichera un des 5 codes d erreurs possibles Certaines pannes comme un court circuit de la sortie la surcharge et de mauvaises batteries peuvent tre corrig es par l utilisateur en liminant le court circuit en r duisant la charge ou en rempla ant les batteries Certaines conditions de panne impliquant le chargeur de batteries et la tension de sortie peuvent n cessiter des r parations ou des changements pour r tablir le fonctionnement normal Si une panne critique survient l ACL affichera les codes d erreurs suivants 1 OUTPUT SHORT CIRCUIT OUTPUT CUTOFF SORTIE COURT CIRCUITEE SORTIE DESACTIVEE e Pour corriger d branchez la source du court circuit de la sortie et red marrez le syst me d alimentation sans coupure UPS 2 OUTPUT OVERLOAD OUTPUT CUTOFF SURCHARGE DE LA SORTIE SORTIE DESACTIVEE e Pour corriger d branchez la source de la surcharge et red marrez le syst me d alimentation sans coupure UPS 3 BATTERY OVERCHARGE SURCHARGE DES BATTERIES e Contactez Tripp Lite pour conna tre les options de d pannage et de r paration 4 BAD AND SEVERELY DISCHARGED BATTERY BATTERIES DEFECTUEUSE OU SEVEREMENT DECHARGEES e Pour corriger remplacez les batteries du syst
45. icien radio TV pour obtenir de l aide Tout changement ou modification apport s cet quipement sans l autorisation expresse de Tripp Lite peuvent annuler le droit de l utilisateur d utiliser cet quipement 35 12 12 069 93 327C indb 35 12 6 2012 9 29 14 AM Enregistrement de la garantie ui Restrictions portant sur les accessoires de l quipement Mod les portant l tiquette d Industrie Canada au Canada seulement AVIS L tiquette d Industrie Canada identifie l quipement certifi Cette certification signifie que l quipement r pond aux exigences de protection de fonctionnement et de s curit du r seau de t l communications tel que prescrit dans le s document s des exigences techniques de l quipement terminal appropri s Le Minist re ne garantit pas que l quipement fonctionnera la satisfaction de l utilisateur Avant d installer cet quipement les utilisateurs devraient s assurer que l quipement est autoris tre branch aux installations de la compagnie de t l communications locale De plus l quipement doit tre install en utilisant une m thode de connexion acceptable Le client devrait tre au courant que la conformit aux conditions qui pr c dent peuvent ne pas pr venir la d gradation du service dans certaines situations Les r parations effectu es l quipement certifi devrait tre coordonn es par une repr sentant d sign par le fournisseur Toutes r parations o
46. ipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide e Do not connect surge suppressors or extension cords to the output of your UPS This might damage the UPS and may affect the surge Suppressor and UPS warranties e Connect the UPS to an outlet that is adequately protected against excess currents short circuits and earth faults as part of the building installation Battery Warnings e Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions There are no user serviceable parts inside the UPS Do not open the UPS except to perform battery replacement Do not open batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles Battery replacement should be performed only by authorized service personnel using the same number and type of batteries Sealed Lead Acid Do not dispose of the batteries in a fire The batteries are recyclable Refer to your local codes for disposal requirements or in the USA only call 1 800 SAV LEAD or 1 800 8 BATTERY 1 800 822 8837 or visit www rbrc com for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the Web at www tripplite com support battery index cfm to locate the specific replacement battery for your UPS 12 12 069 93 327C i
47. it s front panel 2 Carefully pull the front panel away from the UPS WAN N ME LY __ FE EEE SEE EEE ag 7 gt NUIT gt gt gt gt gt a SS S EZ EEE SSS FEE EEE _ gt gt gt SA ES gt TAZA EA gt 4 Carefully pull the old batteries from the UPS and disconnect them AA AN JE E Q AAA TE
48. l affichage indique 100 e D marrez le syst me d alimentation sans coupure UPS ON Pressez et maintenir le bouton POWER ALIMENTATION pendant une seconde Lalarme du syst me d alimentation sans coupure UPS se fera entendre bri vement une fois Les prises de courant identifiges BATTERY SURGE PROTECTED BATTERIES PROTEGEES CONTRE LES SURTENSIONS seront sous tension Le systeme d alimentation sans coupure UPS rechargera automatiquement les batteries internes au besoin Une fois en marche ON votre syst me d alimentation sans coupure UPS est pr t a prot ger l quipement branche contre les coupures de courant les sous tensions les surtensions et les pointes al atoires e Commutez le syst me d alimentation sans coupure UPS hors tension OFF Pressez et maintenir nouveau le bouton POWER ALIMENTATION pendant une seconde 28 12 12 069 93 327C indb 28 12 6 2012 9 29 05 AM Fonctionnement de base suite Affichage cristaux liquides ACL LACL indique une vari t de modes du syst me d alimentation sans coupure UPS et d tats de fonctionnement Pour visualiser les diff rents crans pressez le ut bouton lorsque le syst me d alimentation sans coupure UPS fonctionne aliment la tension du secteur ou dans le mode aliment par les batteries VACL est illustr ici totalement illumin pour identifier toutes les ic nes et les tiquettes disponibles Ceci est des fins d explication seule
49. l equipo conectado a los tomacorrientes An marcados BATTERY SURGE PROTECTED exceden la capacidad de salida del UPS Para encontrar la especificaci n de VA de sus equipos consulte sus placas de identificaci n Si el equipo est especificado en amperes multiplique el n mero de amperes por 120 para determinar los VA Por ejemplo 1 amp x 120 120 VA Si sospecha que ha sobrecargado los tomacorrientes compruebe las pantallas de Porcentaje de Carga y Medidor de Carga Vea las descripciones de Mostrar Condiciones de UPS Energia en la Secci n de Operaci n B sica Si aun no esta seguro ejecute un auto diagn stico Vea la descripci n de Autodiagn stico en la Secci n de Operaci n B sica Instalaci n Opcional Todos los modelos incluyen puertos de comunicaci n USB conectores con protecci n contra sobretensiones de tel DSL Ethernet No compatibles con aplicaciones PoE y enchufes de protecci n de linea coaxial Estas conexiones son opcionales el UPS trabajar correctamente sin estas conexiones Vea la descripci n de los conectores en la secci n de Operaci n B sica para consultar las instrucciones de conexi n Si el cono LINE POWER no se enciende cuando se enciende el UPS intente lo siguiente 1 Cerci rese de que el UPS est enchufado en un tomacorriente de CA activo 2 Oprima y mantenga el BOTON POWER durante un segundo arrancar el UPS Sonara un bip Cuando arranque el UPS
50. ly approved by Tripp Lite could void the user s authority to operate this equipment 11 12 12 069 93 327C indb 11 12 6 2012 9 28 43 AM Warranty Registration continues Equipment Attachment Limitations models with the Industry Canada label in Canada only NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are conn
51. ment il n existe aucun mode de fonctionnement o l cran sera illumin totalement comme ceci exception faite pendant quelques secondes lorsque le syst me d alimentation sans coupure UPS est branch la prise de courant INDICATEURS DES MODES DE FONCTIONNEMENT L ic ne ON LINE MODE EN LIGNE indique que l alimentation CA est pr sente et que le syst me d alimentation sans coupure UPS fonctionne partir d une source d alimentation du secteur Les ic nes AVR amp BUCK R G TENS AUTOM amp R D et AVR amp BOOST R G TENS AUTOM amp AUGM s allumeront s lectivement pendant le mode d alimentation partir du secteur pour indiquer que la r gulation de la tension automatique AVR est active Licone AVR amp BUCK REG TENS AUTOM amp RED indique les conditions de surtension et l alimentation de sortie est r duite a un niveau utilisable L ic ne AVR amp BOOST REG TENS AUTOM amp AUGM indique les conditions de soustension et l alimentation de sortie est augment e un niveau utilisable L ic ne ON BATT BATTERIES indique que le syst me d alimentation sans coupure UPS fonctionne dans le mode Batteries cause d une panne d lectricit ou d une fluctuation s v re de l alimentation d entr e L ic ne REPLACE BATTERY REMPL BATTERIES s allumera pour aviser les utilisateurs que les batteries du systeme d alimentation sans coupure UPS sont faibles et doivent
52. ment des batteries 33 LS seta si Entreposage et entretien 34 Affichage cristaux liquides ACL 29 Enregistrement de la garantie 35 Affichez les tats du systeme Te y Engish 1 Espanol 13 POWER PROTECTION Manufacturing Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Droits d auteur 2012 Tripp Lite Tous droits r serv s SmartPro est une marque d pos e de Tripp Lite 12 12 069 93 327C indb 25 12 6 2012 9 29 04 AM Consignes de s curit importantes CONSERVEZ CES INSTRUCTIONS Ce manuel contient des instructions et des avertissements qui devraient tre respect s pendant l installation l utilisation et l entreposage de ce produit Les manquements ces avertissements ou directives peuvent affecter la garantie Avertissements reli s l emplacement du syst me d alimentation sans coupure UPS e Installez votre syst me d alimentation sans coupure UPS l int rieur loign de l humidit et de la chaleur excessives des contaminants conducteurs de la poussi re et de la lumi re solaire directe e Pour une performance optimale maintenez la temp rature int rieure entre 32 F et 104 F 0 C et 40 C e Maintenez un espacement ad quat tout autour du syst me d alimentation sans coupure UPS pour assurer une ventilation ad quate e N installez le syst me d alimentation sans coupure UPS qu la verticale sur une surface plane robuste Ne bloque
53. nada a usted cuando solicit el RMA 22 12 12 069 93 327C indb 22 12 6 2012 9 29 00 AM Registro de Garantia Visite hoy mismo www tripplite com warranty para registrar la garant a de su nuevo producto Tripp Lite Usted ingresar autom ticamente a un sorteo para tener una oportunidad de ganar un producto Tripp Lite GRATIS No se requiere compra Inv lido en donde est prohibido Aplican algunas restricciones Para detalles consulte el sitio Web Aviso de FCC Parte 68 S lo en los Estados Unidos Si su Protecci n de M dem Fax perjudica la red telef nica la compa a de tel fonos puede suspender temporalmente su servicio Si es posible le notificar n con anticipaci n Si no es pr ctica la notificaci n anticipada se le notificar tan pronto sea posible Estar notificado de su derecho a exponer una queja con la FCC Su compa a telef nica puede hacer cambios en las instalaciones equipo operaciones y procedimientos que puedan afectar la correcta operaci n de su equipo Si esto pasa tendr un aviso anticipado para darle oportunidad de mantener su servicio sin interrupci n Si tiene problemas con esta protecci n de equipos de M dem Fax visite por favor a www tripplite com support para obtener informaci n sobre reparaci n garant a La compa a telef nica pude solicitarle desconectar este equipo de la red hasta haber corregido el problema o usted est seguro que el equipo no est funcionando mal No hay repar
54. ndb 2 12 6 2012 9 28 34 AM Quick Installation STEP 1 Plug the UPS into a properly grounded outlet After plugging the UPS into a wall outlet press and hold the POWER D BUTTON for one second to turn on the UPS See Basic Operation Section Note The UPS will not turn on automatically in the presence of live utility power STEP 2 Plug your equipment into the UPS There are two sets of outlets on the back of your UPS Outlets marked SURGE PROTECTED 5 do not provide battery backup power during power outages Connect common desktop items like printers scanners and other accessories not requiring battery support to these outlets T Outlets marked BATTERY SURGE PROTECTED 5 offer UPS battery backup support during power failures Connect your vital computer equipment into these outlets Your UPS is designed to support electronic equipment only You will overload the UPS if the total VA ratings for all the equipment connected to the BATTERY SURGE PROTECTED outlets exceed the UPS output capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps multiply the number of amps by 120 to determine VA For example 1 amp x 120 120 VA If you suspect you have overloaded the outlets check the Load Percentage and Load Meter screens See Display UPS Power Conditions descriptions in Basic Operation Section If you are still unsure run a self test See Self Test description in Basic Operation Section
55. r que la pantalla de 3 d gitos est informando una condici n de salida voltaje de salida Hz de salida etc BATTERY bater a se enciende para indicar que la pantalla de 3 d gitos est informando una condici n de la bater a voltaje de la bater a ESTIMATED RUNTIME Autonom a Estimada se enciende para indicar que la pantalla de 3 d gitos est informando actualmente el tiempo estimado de autonom a en minutos 11 CONO FAULT se enciende para indicar una variedad de posibles condiciones de falla del UPS para la informaci n acerca de otras fallas informadas vea la secci n de Mensajes de Error 17 12 6 2012 9 28 50 AM Operacion Basica continuacion Informa de las Condiciones de Energia UPS Informacion del LCD del Modo de Alimentacion de Linea La pantalla LCD ofrece 6 pantallas de informaci n del UPS y energ a del sitio mientras el UPS est operando en modo de alimentaci n de l nea Para avanzar a la pantalla siguiente oprima el bot n wove Las pantallas se muestran en este orden 1 VOLTAJE DE SALIDA 2 FRECUENCIA DE ENTRADA SALIDA 3 PORCIENTO DE CARGA DE SALIDA sa z QUEPLT EN 5 sa INPUT oureuT EA 7 a outeur E e on LINE l 6 Vv MUTE on LINE L MUTE OoN LINE L 6 TiO ICL OL OL O a a pa A POTENCIA EN WATTS DE CARGA DE SALIDA 5 VOLTAJE DE ENTRADA 6 VOLTAJE DE BAT
56. ra indicar que la unidad ya no est en modo silencioso Nota Solo puede seleccionarse el modo silencioso mientras la unidad est en l nea El modo silencioso desactivar completamente el biper Para silenciar temporalmente la alarma mientras la unidad est en modo de bater a oprima y sostenga el bot n me hasta que se 7 iA E E E 7 destelle en la pantalla LCD el icono para indicar que la alarma ha sido silenciada temporalmente Nota La alarma de bateria baja sonara aun si la alarma de bateria est silenciada temporalmente 18 12 6 2012 9 28 52 AM Operacion Basica continuacion Auto diagnostico Oprima y mantenga el Ors bot n para iniciar el diagn stico El diagn stico dura aproximadamente 10 segundos y el UPS conmuta a bater a para probar la capacidad con una carga Una vez terminada la prueba el UPS regresar al modo en l nea Si la prueba falla la pantalla indicar un cono Bel y sonara una alarma Si esto ocurre cargue las baterias por 12 horas y repita el Auto diagnostico Si existe otra falla p ngase en contacto con Tripp Lite para consultar opciones de reemplazo de la bater a Si el UPS aprueba el Auto diagn stico la pantalla LCD indicar PAS El equipo conectado puede permanecer encendido durante la prueba No desenchufe su UPS esto eliminar la conexi n segura a tierra Mensajes de Error 7 El UPS informa el estado de REEMPLAZO DE BATERIA y SOBRECARGA usando B y LOAD PANTALLA LCD DE
57. ries UPS sont recyclables Consultez les codes locaux concernant les exigences d limination des d chets ou au E U seulement consultez ces sources pour des renseignements concernant le recyclage 1 800 SAV LEAD 1 800 728 5323 1 800 8 BATTERY 1 800 822 8837 www rbrc com Tripp Lite offre une gamme compl te decartouches de batterie de remplacement de syst me UPS R B C Rendez visite a Tripp Lite sur le Web www tripplite com support battery index cfm pour trouver la batterie de remplacement sp cifique a votre UPS 26 12 12 069 93 327C indb 26 12 6 2012 9 29 04 AM Installation rapide TAPE 1 Branchez le systeme d alimentation sans coupure UPS a une prise de courant correctement mise a la terre Apr s avoir branch le syst me d alimentation sans coupure UPS la la prise de courant murale pressez et maintenir le bouton POWER ALIMENTATION Y pendant une seconde pour le mettre en marche Voyez la section Fonctionnement de base Remarque Le syst me d alimentation sans coupure UPS ne se mettra pas en marche automatiquement l application de la tension du secteur TAPE 2 Branchez votre quipement au syst me d alimentation sans coupure UPS Il existe deux ensembles de prises de courant l arri re de votre syst me d alimentation sans coupure UPS Les prises de courant identifi es SURGE PROTECTED PROTEGEES CONTRE LES SURTENSIONS 5
58. rom Tripp Lite For more information on service visit www tripplite com support Before returning your product for service follow these steps 1 Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit www tripplite com support If the problem requires service visit www tripplite com support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service This simple on line form will ask for your unit s model and serial numbers along with other general purchaser information The RMA number along with shipping instructions will be emailed to you Any damages direct indirect special or consequential to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Products shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the product is within its warranty period enclose a copy of your sales receipt Return the product for service using an insured carrier to the address given to you when you request the RMA 10 12 12 069 93 327C indb 10 12 6 2012 9 28 43 AM Warranty Registration Visit www trippli
59. ry mode press and hold the screen to indicate that the alarm has been temporarily muted temporarily muted 12 12 069 93 327C indb 6 6 se button until the amp icon flashes on the LCD Note The low battery alarm will still sound even if the battery alarm is 12 6 2012 9 28 36 AM Basic Operation continues Self Test Press and hold the Or button to initiate the test The test will last approximately 10 seconds as the UPS switches to battery to test the capacity with a load Upon completion of the test UPS will return to line mode If test fails the display will indicate icon Bel and an alarm will sound If this occurs charge the batteries for 12 hours and repeat the self test If there is another failure contact Tripp Lite for battery replacement options If the UPS passes the self test the LCD screen will read PAS Connected equipment can remain on during the test Do not unplug your UPS this will remove safe electrical grounding Error Messages The UPS reports BATTERY REPLACEMENT and OVERLOAD STATUS using the Bs and the amp icons REPLACE BATTERY LCD SCREEN OVERLOAD LCD SCREEN sa BATTERY ON LINE p I Vv ON LINE HC LL REPLACE lt gt a lt BATTERY LOAD BATTERY In the event that the UPS battery requires replacement the icon If there is an overload the amp amp and icons will light and the will light Replace the UPS battery to reset the replace bat
60. son efficacit n est pas recommand e N utilisez pas cet quipement dans un milieu o il existe un m lange anesth sique inflammable avec de l air de l oxyg ne ou de l oxyde nitreux e Ne branchez pas de suppresseurs de surtensions al atoires ou de cordons prolongateurs la sortie de votre syst me d alimentation sans coupure UPS Ceci pourrait endommager le syst me d alimentation sans coupure UPS et pourrait affecter les garanties des suppresseurs de surtensions al atoires et du syst me d alimentation sans coupure UPS e Branchez le syst me d alimentation sans coupure UPS une prise de courant qui est d ment prot g e contre les courants excessifs les courts circuits et les d fauts la terre faisant partie de l installation lectrique du b timent Avertissements portant sur les batteries e Parce que les batteries pr sentent un risque de choc lectrique et de courant de court circuit lev prenez les pr cautions n cessaires Ne pas jeter les batteries au feu Ne pas ouvrir les batteries Ne pas tablir de court circuit ou de pont entre les bornes de la batterie avec un quelqconque objet D brancher et teindre UPS avant de remplacer la batterie Le remplacement de la batterie doit tre confi du personnel de service qualifi Utiliser des outils ayant des poign es isol es et remplacer les batteries existantes par des batteries neuves du m me num ro et du m me type batterie sans entretien Les batte
61. syst me d alimentation sans coupure UPS pendant une p riode de temps prolong e rechargez les batteries fond tous les trois mois Branchez le syst me d alimentation sans coupure UPS une prise de courant CA du secteur mettez le en marche en pressant et maintien le bouton POWER ALIMENTATION Y et permettez aux batteries de se recharger pendant 4 a 6 heures Si vous laissez les batteries de votre syst me d alimentation sans coupure UPS d charg es pendant une longue p riode de temps leur capacit sera affect e de facon permanente Entretien Une gamme de garanties prolong es et de programmes d entretien sur place sont disponibles chez Tripp Lite Pour plus de renseignements relatifs a l entretien visitez www tripplite com support Avant de retourner votre produit pour la r paration proc dez comme suit 1 Passez en revue les proc dures d installation et de fonctionnement de ce manuel afin de vous assurer que le probl me ne provient pas d une mauvaise interpr tation des instructions 2 Si le probl me persiste ne communiquez pas et ne renvoyez pas le produit chez votre fournisseur Visitez plut t le site www tripplite com support 3 Si le probl me n cessite une r paration visitez www tripplite com support et cliquez sur le lien des retours De la vous pouvez demander une autorisation de retour de mat riel RMA qui est requise pour le service d entretien Ce simple formulaire en ligne vous demandera d indiq
62. t temporairement d sactiv Bouton TEST Pressez et retenez ce bouton le syst me d alimentation sans coupure UPS lancera un autotest qui durera environ 10 secondes 4 Connecteurs de protection de ligne Tel DSL NETWORK T l DSL R SEAU Ces connecteurs prot gent contre les surtensions une ligne t l phonique ou une connexion de r seau individuellede l quipement Le branchement de votre quipement ces connecteurs est optionnel Votre syst me d alimentation sans coupure UPS fonctionnera correctement sans ces connexions 5 Connecteurs de protection de cable coaxial Ces connecteurs prot gent contre les surtensions la ligne coaxiale de l quipement Le branchement de votre quipement a ces connecteurs est optionnel Votre syst me d alimentation sans coupure UPS fonctionnera correctement sans ces connexions 6 Port de communication USB Ce port peut brancher votre syst me d alimentation sans coupure UPS n importe quel ordinateur pour la sauvegarde automatique de fichiers et la commutation hors tension sans surveillance dans le cas d une coupure de courant Utilisez avec le logiciel PowerAlert de Tripp Lite offert GRATUITEMENT en t l chargement www tripplite com et un cable USB appropri Un cable USB est inclus avec votre syst me d alimentation sans coupure UPS Cette connexionest optionnelle Votre syst me d alimentation sans coupure UPS fonctionnera correctement sans cette connexion Remarque Ce syst me
63. te com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC Part 68 Notice United States Only If your Modem Fax Protection causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If it does you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this equipment s Modem Fax Protection please visit www tripplite com support for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning There are no repairs that can be made by the customer to the Modem Fax Protection This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or
64. tery indicator LCD screen will report the output load percentage CRITICAL FAULT SCREENS Some more severe fault conditions will result in the UPS shutting off power to the UPS supported output receptacles At this point the LCD screen will report any one of 5 possible on screen fault codes Some faults such as output short circuit overload and bad battery can be user corrected by removing the short reducing the load or replacing the battery Some fault conditions involving the battery charger and output voltage may require repair or replacement in order to restore normal operation If a critical fault occurs the LCD display will show the following error codes 1 OUTPUT SHORT CIRCUIT OUTPUT CUTOFF 3 BATTERY OVERCHARGE e To clear disconnect the source of the output short circuit e Contact Tripp Lite for troubleshooting and repair options and restart the UPS 4 BAD AND SEVERELY DISCHARGED BATTERY 2 OUTPUT OVERLOAD OUTPUT CUTOFF e To clear replace the UPS battery e To clear disconnect the source of the overload and restart the UPS 5 OUTPUT VOLTAGE HIGH IN BATTERY MODE e Contact Tripp Lite for troubleshooting and repair options 12 12 069 93 327C indb 7 12 6 2012 9 28 38 AM Features UPS Features BATTERY SURGE Y PROTECTED SURGE PO TECTED SID LPS FAX PHONE LAN SURGE PROTECTION _ A IN K OUT O O CABLE VIDEO 7 SURGE PROTECTION TRIPP LITE 1 O
65. tional Your UPS will work properly without this connection Note This UPS System provides basic communication compatibility with most integrated Windows Macintosh and Linux power management applications 7 SURGE SUPPRESSION ONLY Outlets These outlets offer premium surge suppression for accessories not requiring battery backup support These outlets are always energized when the UPS is connected to a live outlet even if the UPS is turned off 8 BATTERY BACKUP Outlets These outlets offer battery backup support and premium surge suppression for critical devices requiring battery backup support Note Do not plug laser printers into the battery backup outlets 9 Resettable Input Circuit Breaker Protects your electrical circuit from over current draw from the UPS load If this breaker trips remove some of the load then reset it by pressing it in 12 12 069 93 327Cindb 8 12 6 2012 9 28 38 AM Battery Replacement Under normal conditions the original battery in your UPS will last several years Battery replacement should only be performed by qualified personnel Refer to Battery Warnings in the Safety section for complete battery safety information Your UPS requires two Tripp Lite RBC51 replacement battery cartridges For further information about replacement compatibility and ordering visit Tripp Lite on the Web at www tripplite com support battery index cfm To Replace the Batteries 1 Remove screw at the bottom of the un
66. u modifications effectu es par l utilisateur cet quipement ou pour corriger les pannes de l quipement peuvent avoir comme r sultat que la compagnie de t l communications demande l usager de d brancher l quipement Les utilisateurs devraient s assurer pour leur propre protection que les connexions lectriques la terre de l alimentation du secteur de lignes t l phoniques et le syst me de tuyauterie m tallique interne pour l eau s il en existe soient bien reli s ensemble Cette pr caution peut tre particuli rement importante dans les secteurs ruraux Avertissement Les utilisateurs ne devraient pas tenter d effectuer les connexions eux m mes ils devraient contacter l agence d inspection lectrique ou un lectricien selon le cas Non compatible pour les applications n cessitant l alimentation lectrique par c bles Ethernet PoE Remarque sur l tiquetage Deux symboles sont utilis s sur l tiquette V Tension CA V Tension CC Num ros d identification la conformit r glementaire des fins de certification de conformit r glementaire et d identification un num ro de s rie unique a t attribu votre produit Tripp Lite Le num ro de s rie ainsi que toutes les marques d homologation et les informations requises se trouvent sur la plaque signal tique du produit Lorsque vous demandez des informations sur la conformit de ce produit reportez vous toujours au num ro de s rie
67. ue la falla de este equipo cause la falla de del equipo de soporte de vida o afecte significativamente su seguridad o efectividad No use este equipo en presencia de mezcla anest sica inflamable con aire ox geno u xido nitroso e No conecte supresores de sobretensiones o cables de extensi n a la salida de su UPS Esto puede da ar el UPS y pude afectar las garant as del supresor de sobretensiones y del UPS e Conecte el UPS a un tomacorriente que tenga la protecci n adecuada contra corrientes excesivas cortocircuitos y fallas de conexi n a tierra como parte de la instalaci n del edificio Advertencias de la Bater a e Debido a que las bater as presentan un peligro de choque el ctrico y quemaduras por las altas corrientes de cortocircuito tome las precauciones adecuadas No deseche las bater as en un incinerador No abra las bater as No ponga los terminales de la bater a en corto o en puente con ning n objeto Apague y desconecte el UPS antes de reemplazar la bater a S lo debe cambiar las bater as personal t cnico debidamente capacitado Use herramientas con mangos aislados y reemplace las bater as existentes con el mismo n mero y tipo de bater as nuevas plomo cido selladas Las bater as del UPS son reciclables Consulte la reglamentaci n local para los requisitos de disposici n de desechos para los EE UU solamente consulte estas fuentes para informaci n sobre reciclaje 1 800 SAV LEAD 1 800 728 5323 1 800 8 BATTERY
68. uer le mod le de votre appareil son num ro de s rie ainsi que d autres renseignements g n raux Le num ro RMA ainsi que des instructions d exp dition vous seront transmis Les dommages directs indirects particuliers ou cons cutifs encourus par le produit lors du transport vers Tripp Lite ou vers un centre de service autoris Tripp Lite ne sont pas couverts par la garantie Les frais li s au transport des produits exp di s a Tripp Lite ou a un centre de service autoris Tripp Lite doivent tre enti rement pay s d avance Inscrivez le num ro de RMA l ext rieur de l emballage Si le produit est dans sa p riode de garantie joignez une copie de votre recu de caisse Retournez le produit pour r paration par un transporteur assur l adresse qui vous est donn e lorsque vous demandez le RMA 34 12 12 069 93 327C indb 34 12 6 2012 9 29 14 AM Enregistrement de la garantie Visitez www tripplite com garantie aujourd hui pour enregistrer la garantie de votre nouveau produit Tripp Lite Vous serez automatiquement inscrit un tirage vous offrant la chance de gagner un produit Tripp Lite Aucun achat requis Nul o interdit Certaines restrictions s appliquent Visitez le site Web pour obtenir plus de renseignements Avis de la FCC section 68 tats Unis seulement Si le modem ou le t l copieur de votre syst me de protection endommage le r seau t l phonique la compagnie de t l phone peut
69. ure UPS dureront plusieurs ann es Le remplacement des batteries ne devrait tre effectu que par du personnel qualifi R f rez vous aux avertissements portant sur les batteries de la section S curit pour tous les renseignements portant sur la s curit reli e aux batteries Votre syst me d alimentation sans coupure UPS requiert deux cartouches de batteries de rechange RBC51 de Tripp Lite Pour plus de renseignements relatifs la compatibilit des unit s de rechange et pour commander visitez le site Web de Tripp Lite www tripplite com support battery index cfm Pour remplacer les batteries 1 Retirez la vis au bas du panneau avant de l unit 2 Retirez avec soin le panneau avant du syst me d alimentation sans coupure UPS AY S gt LEE st TRIPP LITE 4 Retirez avec soin les vieilles batteries du syst me d alimentation sans coupure UPS et d branchez les N
70. z pas les ouvertures des ventilateurs ou de ventilation puisque cela pourrait limiter le refroidissement interne de l unit et causer des dommages mat riels non couverts par la garantie Avertissements reli s aux connexions du syst me d alimentation sans coupure UPS e Branchez votre syst me d alimentation sans coupure UPS directement une prise de courant CA mise la terre correctement Ne branchez pas le syst me d alimentation sans coupure UPS lui m me ceci l endommagera e Ne modifiez pas la fiche du syst me d alimentation sans coupure UPS et n utilisez pas d adaptateur qui liminerait la mise la terre e N utilisez pas de cordons prolongateurs pour brancher le syst me d alimentation sans coupure UPS a une prise de courant CA e Si le syst me d alimentation sans coupure UPS est aliment a partir d une g n ratrice entra n e par un moteur la g n ratrice doit fournir une tension de sortie propre filtr e et adapt e aux quipements informatiques e La prise de courant du secteur alimentant le syst me d alimentation sans coupure UPS devrait facilement accessible et situ e pr s de l appareil Avertissements reli s aux connexions de l quipement e __ l utilisation de ce syst me d alimentation sans coupure UPS dans les applications de soutien vital ou une panne de cet quipement est susceptible de causer une panne de l quipement de soutien vital ou d affecter s rieusement sa s curit ou