Aten AT-VM0808H

image

Contents

1. Long Distance Transmission supports up to 20 meters 24 AWG HDMI standard cable HDMI 3D Deep Color and HDCP compatible Easily switch between multiple sources and multiple displays Local Operation Front panel LCD display Tuner Dials and Pushbuttons IR Remote Control Serial controller Remote Operation Browser Graphical User Interface GUI Superior video quality HDTV resolution of 480p 720p 10801 and 1080p 1920 x 1080 VGA SVGA SXGA UXGA and WUXGA 1920 x 1200 Supports Dolby True HD and DTS HD Master audio Signaling rates up to 2 25 Gbits in support of 1080p display Feature EDID Expert technology to set up different configurations via different EDID modes Power on Detection If an HDMI source is powered off the VM0808H can automatically switch to the next powered on source Firmware upgradeable Rack Mountable Chapter 1 Introduction Requirements The following equipment is required for a complete VMO808H installation Source Devices HDMI Type A output connector s Note A DVI HDMI adapter is required when connecting a DVI source device Display Devices Display devices or receivers with an HDMI Type A input connector Cables 1 HDMI cable for each source device you will be connecting HDMI cable for each display device you will be connecting Note No cables are included in this package We strongly recommend that you purchase
2. 4 Press the OUT IN or ENTER pushbutton to confirm the Subnet Mask 5 Press ESC to return to the previous step without change Note The default Subnet Mask is 255 255 255 0 Gateway To set the VM0808H s Gateway do the following 1 Select Gateway from the Set IP Port submenu The cursor flashes on the first number ESC OUT IN MENU 0 Gateway 192 168 0 1 1 o C NIEN Default IP Setting No a C C PROFILE ENTER 2 Turn the front panel IN dial left or right to cycle through and change each number 3 Turn the front panel OUT dial left or right to move the cursor to each position 20 Chapter 3 Local Operation 4 Press the OUT IN or ENTER pushbutton to confirm the Gateway 5 Press ESC to return to the previous step without change Note The default Gateway is 192 168 0 1 Default IP Settings To use not use the VM0808H s Default IP Settings do the following 1 Select Default IP Settings from the Set IP Port submenu The cursor flashes on the entry ESC OUT IN MENU om Gateway 192 168 0 1 A C c Bo b Default IP Setting NO CC CO PROFILE ENTER 2 Turn the front panel IN dial left or right to select Yes or No 3 Press and Release the OUT IN or ENTER pushbutton to confirm the change Save and Reset Exit After each operation you can either PROFILE ENTER EN and ResettheDevice NIEN Exit without Save
3. The following tables show the possible values for the Power on Detection commands Command Description pod Power On Detection function Control Description on Enable power on detection function off Disable power on detection function 51 VMO0808H User Manual Power on Detection Command Table Command Control Enter Description pod on Enter Turn on power on detection default pod off Enter Turn on power off detection Acknowledge Ack Description Command OK Command is correct and function executed Command Incorrect Unavailable command or parameters After commands are sent acknowledge messages are returned Appendix Safety Instructions General Read all of these instructions Save them for future reference Follow all warnings and instructions marked on the device Do not place the device on any unstable surface cart stand table etc If the device falls serious damage will result Do not use the device near water Do not place the device near or over radiators or heat registers The device cabinet is provided with slots and openings to allow for adequate ventilation To ensure reliable operation and to protect against overheating these openings must never be blocked or covered The device should never be placed on a soft surface bed sofa rug etc as this will block its ventilation openings Likewis
4. To prevent damage to your installation it is important that all devices are Use a grounding wire to ground the VMO0808H by connecting one end of the wire to the grounding terminal and the other end of the wire to a suitable grounded object le d d d d d d d d Bg 2 Make sure that all devices in your VM0808H installation are properly grounded VMO808H User Manual Cable Connection Installation of the VMO808H is simply a matter of connecting the appropriate cables Refer to the installation diagram on the following page the numbers in the diagram correspond to the steps below and do the following 1 Moo If using Remote Operation features plug Cat 5e cable from the LAN into the VM0808H s Ethernet port If you are using the serial control function use an appropriate RS 232 serial cable to connect the computer or serial controller to the VM0808H s female RS 232 port Usea grounding wire to ground the unit by connecting one end of the wire to the grounding terminal and the other end of the wire to a suitable grounded object Note Do not omit this step Proper grounding helps to prevent damage to the unit from surges or static electricity Connect up to 8 HDMI video sources to the HDMI Input ports Connect up to 8 HDMI display
5. Username Please enter 5 16 characters only 0 9 a z Password Please enter 5 16 characters only 0 9 a z Confirm Password Please enter 5 16 characters only 0 9 a z Description Max 16 characters only 0 9 a z A Z Status O Administrator Add Edit Delete all users full rights Super User Full rights User Basic rights make ties save and recall the Profiles Click Add to add a user fill in the username password description select the appropriate privileges see Privileges page 44 and click Submit Edit User Username user_1 Please enter 5 16 characters only 0 9 a z _ Password c Please enter 5 16 characters only 0 9 a z _ Confirm Password 999999999 Please enter 5 16 characters only 0 9 a z Description user profile 1 Max 16 characters only 0 9 a z A Z Status O Administrator Add Edit Delete all users full rights Super User Full rights o User Basic rights make ties save and recall the Profiles Use this page to rename a user set reset a user s password add a description of a user and to set a user s privileges for accessing the VM0808H s GUI Usernames and passwords are case sensitive and must be 5 16 alphanumeric characters If a user is logged into the VM0808H s GUI their user settings can t be edited and the boxes will be grayed out 43 VMO0808H User Manual Privileges Use the Edit User function to set a user s privileges The
6. serial number and date of purchase Your computer configuration including operating system revision level expansion cards and software Any error messages displayed at the time the error occurred The sequence of operations that led up to the error Any other information you feel may be of help 56 Appendix Specifications Function VM0808H Connectors HDMI In 8 x HDMI Type A Female Black HDMI Out 8 x HDMI Type A Female Black Ethernet 1 x RJ 45 Female RS 232 1 x DB 9 Female Black IR Input Port 1 x Mini Stereo Jack Female Black Power 1 x 3 prong AC Socket Switches In 1 x Tuner Button Out 1 x Tuner Button Esc 1 x Pushbutton Menu 1 x Pushbutton Profile 1 x Pushbutton Enter 1 x Pushbutton Power 1 x Rocker LEDs Menu 1 Green Profile 1 Green I P Rating 100 240VAC 50 60Hz 1A Power Consumption 120V 32W 230V 34W Environment Operating Temp 0 50 C Storage Temp 20 60 C Humidity 0 80 RH Non condensing Physical Housing Metal Properties Weight 4 01 kg Dimensions L x W x H 43 24 x 27 12 x 4 40 cm 57 VMO808H User Manual Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMENTATI
7. 08 sw o yy Enter Switch Next Input to _ Output Port yy Switch Previous Input to Output Port yy yy 01 08 Acknowledge Ack Description Command OK Command is correct and function executed Command Incorrect Unavailable command or parameters After commands are sent acknowledge messages are returned Note 1 Each command string can be separated with a space 2 The Port Number command string can be skipped and the default value will be used 47 VMO808H User Manual EDID Commands The formulas for EDID commands are as follows 1 EDID Command Control Enter For example to change EDID to use the port setting type the following edid port1 Enter Possible Values The following table shows the possible values for switch commands EDID Command Description edid EDID mode selection Control Description port The EDID from port1 will be passed to all video Sources remix Uses the EDID of each connected display according to its connection when the VM0808H is first powered on or immediately after pressing ENTER to select the Remix option default The default EDID will be passed to all video sources Enter Description Enter Key Send out command EDID Command Table Command Control Enter Description edid porti Enter Key The EDID from port1 will be passed to all video sources edid remix Enter Key Uses
8. C C Save and Reset the Device to save all changes and restart the VM0808H Exit without Save to ignore changes and return to the Menu or Press ESC to return to the previous step without change 21 VMO808H User Manual Set Serial Port To configure the VM0808H s serial port settings select Set Serial Port from the Menu page Set IP Port Ud set Serial Port Y C PROFILE ENTER The sub menu provides two options Default Serial Settings and Baud Rate as follows Default Serial Settings To use not use the VM0808H s Default Serial Settings do the following 1 Select Default Serial Settings from the Set Serial Port submenu The cursor flashes on the entry OUT IN z MENU ESC gt Default Serial Setting NO 1 C NIEN Baud Rate 19200 1G PROFILE ENTER 2 Turn the front panel IN OUT dial left or right to select Yes or No 3 Press and Release the OUT IN or ENTER pushbutton to confirm the change Note The default serial setting is No 22 Chapter 3 Local Operation Baud Rate To set the VM0808H s baud rate do the following 1 Select Baud Rate from the Set Serial Port submenu The cursor flashes on the first number OUT IN MENU ESC Default Serial Setting NO of C WAN Baud Rate 19200 gun C PROFILE ENTER Turn the front panel IN OUT dial to cycle through the options Baud Rate options
9. devices to the HDMI Output ports Connect the IR Receiver into the External IR Receiver Input Port Plug the power cord supplied with the package into the VM0808H s 3 prong AC socket and then into an AC power source Power on the VM0808H and all devices in the installation Continues on next page Chapter 2 Hardware Setup Installation Diagram VMO808H User Manual This Page Intentionally Left Blank Chapter 3 Local Operation Overview The VMO808H can be configured and operated locally on the front panel LCD via tuner dials pushbuttons and IR Remote Control remotely over a standard TCP IP connection via graphical user interface GUI using a web browser or by a RS 232 serial controller The local front panel operation is discussed in this chapter Over IP operation is discussed in Chapter 4 and RS 232 serial control is discussed in Chapter 5 Front Panel Operation The VM0808H front panel features pushbuttons tuner dials and an LCD display panel for convenient configuration and operation locally This allows you to perform operations such as selecting which source displays on which display configuring the IP port configuring the serial port setting Power On Detection and EDID modes selecting security settings and loading saving connection profiles Basic Navigation The VM0808H s front panel display operation is easy and convenient
10. off all Output displays To power on off all Output displays simultaneously with the remote control do the following 1 Press the ON or OFF pushbutton 2 Repeatstep 1 to simultaneously change back the power status of all Output ports to on or off respectively The ON or OFF pushbuttons bring all displays to the same power status regardless of the individual power statuses 30 Chapter 4 Remote Operation Overview The VM0808H 8x8 HDMI Matrix Switch can be configured and controlled over a standard TCP IP connection via its own Browser Graphical User Interface GUI Because the VM0808H can be accessed from anywhere on the LAN WAN or Internet remote operators can log in via Web browsers using IE 7 and above Security is ensured by password protection and user configurable time out The VMOSOSH supports three levels of remote users with various operational privileges and up to 32 users can log into the GUl at one time For full details see the sections that follow Logging In To access the Browser GUI type the VM0808H s IP address into the address bar of any browser If a Security Alert dialog box appears accept the certificate it can be trusted The welcome screen appears VMO808H Login Username Password The VMO808H s default IP address is http 192 168 0 60 See Setup page 36 for further information The default username and password are administrator password See User Manageme
11. 000 aa eee tice hates ee het RIAM an ii User Information 0 llle eee eee ena iii Online Registration iii Telephone 5 iii User Notices sh a wikia neces Pre CC eels Rr e wad rls Aca iii Package Contents iv Gontentsxs ice eiu oe ee caged eie skr CHUA E RO sac eu V About this Manual viii Conventions ees erii aL eee Rp E LLL de ix Product Information uuu e em ix 1 Introduction GOVerVIGWa tna Ge ti pel d eet M ons En 1 5 idee lee e doa nee DOM 2 Requirements lee duc a eee oops gen ORE 3 Source Devices Sess Sos ce new en 3 Display Devices ra i an 3 Gables 2 crure ca uua beheben poke a malate ei 3 Source Device Operating Systems 4 Components 21 3 4 Pe cle eae wee oan eae eee 5 Front View ucc name ate ewes ae 5 Bear VIGW s re ue Baw ee goa he Be lee 6 IR Remote Gontiol Ill nt 7 2 Hardware Setup Rack Mounting fio pyle tha a aaa aaa REIP ROUES 9 Grotindilig 2 Ira peur b AMPH dete iad 11 Cable 12 Installation Diagram 13 3 Local Operation OvervieW Be dan PA RU ER
12. 8H User Manual Save Load Profile The VMO0808H allows you to store up to 32 numbered 0 31 different connection profiles that can be saved and recalled later When profiles are saved they are saved according to the current connection configuration on the Main page When you load a profile the change is immediate and the profile number is shown in the lower right corner of the LCD display To save load profiles from the Main page do the following 1 Use the MENU button to access the Menu page turn the OUT IN dial to scroll down and select ENTER Save Load Profile MENU ESC TEN Save Load Profile E a c PROFILE ENTER 2 save the current connection configuration as a profile select ENTER Save to a Profile No turn the IN OUT dial to cycle through the numbers 0 31 and press the OUT IN or ENTER pushbutton to save the profile as the number you select MENU ESC AN ATEN Save to a Profile No 00 s f EN Call a saved Profile No 00 J WY A PROFILE ENTER 3 To load a saved Profile select ENTER Call a Saved Profile No turn the IN OUT dial to cycle through the profiles 0 31 and press the OUT IN or ENTER pushbutton to select the profile to load Save to a Profile No 00 TEN Call a Saved Profile No 00 co PROFILE ENTER 28 Chapter 3 Local Operation IR Remote Control Operation The remote control allows you to change the Out
13. 8x8 HDMI Matrix Switch VM0808H User Manual www aten com VMO0808H User Manual FCC Information This is an FCC Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense RoHS This product is RoHS compliant Safety This product has been classified as Information Technology Equipment SJ T 11364 2006 The following contains information that relates to China ADR FB BER BE 8 1 3 RRR SEE DREAMY Best 11363 200638 xERS IR SERS To RTHAMHMRRAR H E MAEDA 3E 15 RoE A SU T 11363 2006 RO RR EER x RRKASA EUER 15 BS ER ER HHSJ T 11363 20069 BR R Se Ko co I V
14. 8x8 HDMI Matrix Switch is a distinct HDMI solution that offers an easy and affordable way to route any of 8 HDMI video sources to any of 8 HDMI displays and view them in any arrangement As a matrix switch the VM0808H allows eight HDMI source devices to cross connect to eight HDMI displays at the same time while giving you independent input output control of each in any array possible The VM0808H gives the ultimate flexibility and control for any HDMI multi display installation Convenient configuration and operation is done via Graphical User Interface GUD using any web browser locally by front panel LCD display with easy to use tuner dials pushbuttons and IR Remote Control or via high end system controllers using the built in RS 232 serial controller The VMO808H unit can be controlled over a standard TCP IP connection and seamlessly integrates with any existing network for easy remote access Furthermore for complete system integration RS 232 control is standard with the VM0808H s built in bi directional RS 232 serial port that allows the switch to be controlled through a high end controller PC and or home automation home theater software package With easy operation simple setup dynamic display and convenient control features the VMO808H is the only HDMI solution that gives a multi display installation everything it needs VMO0808H User Manual Features Connects any of 8 HDMI sources to any of 8 HDMI displays
15. EDID Default Port1 Remix Security Mode Password Required Yes No Change Password Old Password New Password Save Load Profile Save to a Profile No 0 31 Call a Saved Profile No 16 Chapter 3 Local Operation Enter Password If the VM0808H has been configured to require a password for local operation see Security Mode page 26 the password screen appears when the VMO808H is powered on and the cursor flashes on the first digit Enter a 4 digit password to continue to the Main Screen Note If you are accessing the VMO808H for the first time the default password is 1234 OUT MENU ESC Enter Password 0000 C NEN 0000 a C PROFILE ENTER To enter a password do the following 1 Turn the front panel OUT dial left or right to move the cursor position 2 Turn the front panel IN dial left or right to cycle through the numbers 3 Press and Release the OUT IN or ENTER pushbutton to confirm the password and continue to the Main Screen Note 1 If you enter an incorrect password re enter the correct password over the incorrect string 2 If Password Required see Security Mode page 26 is enabled the LCD displays time out is 5 minutes VMO0808H User Manual Main Page The Main screen displays Output Ports 1 8 in sequential order across the top The Input source displaying on each Output port is shown directly ben
16. IN dial to scroll down and select ENTER Operation Mode ESC am Operation Mode oc ATEN Mod 2 a 2 Turn the IN OUT dial to move the arrow to the EDID position and press the OUT IN or ENTER pushbutton to select EDID ESC OUT IN MENU Power on Detection ON c3 TEN Bo EDID Default gt PROFILE ENTER 3 Turn the front panel OUT IN dial to cycle through the options Default Portl or Remix 4 Press and Release the OUT IN or ENTER pushbutton to confirm the change EDID Option Description Default The default EDID will be passed to all video sources Port1 The EDID from port1 will be passed to all video sources Remix Uses the EDID of each connected display according to its connection when the VM0808H is first powered on or immediately after pressing ENTER to select the Remix option Note The default EDID setting is Default 25 VMO808H User Manual Security Mode The Security Mode page allows you to configure the VM0808H s password related settings Password Required and Change Password The Password Required option sets the VMO808H to require a password for local operation after the units LCD display times out default 5 minutes or is powered off on The Change Password option allows you to set a new password for the VMO808H Password Settings To configure the VM0808H s password settings from the Main screen do the following 1 Use the
17. Load Profile 50 Power On Detection 51 Appendix Safety 5 5 53 Generali dci pae ubi s RT s 53 Rack Mounting mmc REIR IET E ER ix 55 Technical Support tee ae 56 International 2 2 euren nn 56 North AMETIGA unse ara ang 56 Specifications 2 eher Ree ne Web pad ern 57 Limited Warranty 2 a E a EE ERR 58 vii VMO808H User Manual About this Manual This User Manual is provided to help you get the most from your VM0808H system It covers all aspects of installation configuration and operation An overview of the information found in the manual is provided below Chapter 1 Introduction introduces you to the VM0808H system Its purpose features and benefits are presented and its front and back panel components are described Chapter 2 Hardware Setup describes how to set up your VM0808H installation Chapter 3 Local Operation explains the fundamental concepts involved in operating the VM0808H at the local site via the front panel LCD display using tuner dials pushbuttons and the IR remote control Chapter 4 Remote Operation provides a complete description of the VM0808H s Browser Graphical User Interface GUI and how to use it to remotely configure and operate VM0808H Chapte
18. MENU button to access the Menu page turn the OUT IN dial to scroll down and select ENTER Security Mode Operation Mode ATEN b Security Mode PROFILE ENTER 2 To set the 808 to require a password for local operation select ENTER Password Required and turn the IN OUT dial to select Yes or No and press the OUT IN or ENTER pushbutton to confirm MENU ESC Bub a Password Required YES ATEN Change Password of C PROFILE ENTER 3 To change the password use the IN OUT dial to move the arrow to Change Password and press the OUT IN or ENTER pushbutton to select Continues on next page 26 Chapter 3 Local Operation Continued from previous page PROFILE ENTER MENU ESC OUT IN Password Required YES 709 C4 MEN e Change Password 4 Enter the old password see Enter Password page 17 Then press the OUT IN or ENTER pushbutton to create a New Password and enter the new password in the same way OUT IN MENU ESC ATEN Old Password 1234 c New P d 0000 lew Passwor a Cc ca PROFILE ENTER 5 Press and Release the OUT IN or ENTER pushbutton to confirm the password and continue to the Main Screen Note 1 If you enter an incorrect password re enter the correct password over the incorrect string 2 If Password Required see Security Mode page 26 is enabled the LCD displays time out is 5 minutes 27 VMO080
19. MO808H User Manual User Information Online Registration Be sure to register your product at our online support center International http support aten com North America http www aten usa com product_registration Telephone Support For telephone support call this number International 886 2 8692 6959 China 86 10 5255 0110 Japan 81 3 5615 5811 Korea 82 2 467 6789 North America 1 888 999 ATEN ext 4988 United Kingdom 44 8 4481 58923 User Notice All information documentation and specifications contained in this manual are subject to change without prior notification by the manufacturer The manufacturer makes no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose Any of the manufacturer s software described in this manual is sold or licensed as is Should the programs prove defective following their purchase the buyer and not the manufacturer its distributor or its dealer assumes the entire cost ofall necessary servicing repair and any incidental or consequential damages resulting from any defect in the software The manufacturer of this system is not responsible for any radio and or TV interference caused by unauthorized modifications to this device It is the responsibility of the user to correct such interference The manufacturer is
20. ON The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or update For further inquiries please contact your direct vendor 58
21. OR ed 15 Front Panel 15 Basic Navigation llle 15 Menu Organization 16 Enter Password x 2p RAV ECTS 17 Malti Page ege RE eR ER eed e o es Kr 18 Profiles nct ee Ame edt tea idus 18 Video In 18 Pott iudi rer e e n Ee EE YR 19 VMO808H User Manual IP Address xine ees 19 subnet Mask oe ie a0 ag EN 20 GaleWady coe e Ert n Mind Roe needed pad 20 Default IP 21 Save and Reset 21 Set Serial e an a AS eu 22 Default Serial 22 Baud Rate ii rel ne Bir lad 23 Operation Mode sex pera eben d Xo RE Romi ee 24 Power on 24 cae AEN fend ocn dig 25 Security Mode a ce ne Ri TIG eI 26 Password Settings 00 0 eese eere 26 Save Load 28 IR Remote Control Operation 29 Change the Input source of an Output display 29 Power on off individual Output displays 29 Power on off all Output displays 30 4 Remote Operation
22. OvervieW ios nen TV ANDER a 31 Logging Ip se are ed er aa oem arto Yoda ge e p de Ro eed 31 Connections Page 32 LE tee 33 Configuring Connections 34 Status Me oe ke epee A E 34 Save Load Connection Profiles 35 Viewing Port Information 35 Imc IEEE 36 IP cuis t E Aretes OE Net orar she ss koe ua 36 Serial Set p ux ire oe ex EE DER De E E D RR EAT 37 Port RE eer s eA Ro RE do eR 38 Firmwares us uaa eder uper Seal EE danken dcr PA eur Edd 39 Profile Selection EP VULG ee 40 Add Delete Selection 40 Profile Selection 41 User Management ee I nen 42 Add User seta einiger a Au uis 43 Edit 7 ru ces ee ees e AL had 43 Privileges i gd irum eed PI monde beled wire 44 5 RS 232 Commands Serial Control Protocol Commands 45 Configuring the Serial Port 45 Switch Port 45 EDID C ommandSi edsa a e 48 vi VMO808H User Manual Mute Commands ee eee een ee 49 Save
23. Please note the following front panel button and dial operations Use the MENU pushbutton to access the Menu page options Set IP Port Set Serial Port Operation Mode Security Mode and Save Load Profile Use the PROFILE pushbutton to switch between the connection profiles which have been added to the Profile Selection list see Profile Selection page 40 Use the ESC pushbutton to go back a level return to the Main page or exit Use the ENTER or tuner dial pushbuttons to select options and confirm operations Use the tuner IN and OUT dials to cycle forward or backward through the menus or options VMO808H User Manual Menu Organization Use the MENU pushbutton to switch between the Main Screen and Menu page From the Main screen press the MENU pushbutton to access the Menu page and cycle through the menu options using the tuner dials starting from Set IP Port in the order show in the table below Menu Page Sub Menu Page s Password Main Page Select Video IN 1 8 or N A Profile Pressing the front panel PROFILE pushbutton cycles through the connection Profiles added to the Profile Selection list See Profile Selection page 40 Set IP Port IP Address Subnet Mask Save and Reset Exit Gateway Default IP Settings Yes No Set Serial Port Default Serial Setting Yes No Baud Rate 9600 19200 38400 115200 Operation Mode Power On Detection Off On
24. UT IN dial to move the cursor to the Set IP Port position and use the OUT IN or ENTER pushbutton to select Set IP Port MENU Esc en WM Bet IP Port ees ju Set Serial Port PROFILE ENTER The sub menu provides four options IP Address Subnet Mask Gateway and Default IP Settings as follows IP Address To set the VM0808H s IP address do the following 1 Select IP Address from the Set IP Port submenu The cursor flashes on the first number ESC OUT IN MENU We IP Address 192 168 0 60 5 NIEN Subnet Mask 255 255 255 0 j Ca ca PROFILE ENTER 2 Turn the front panel IN dial left or right to cycle through and change each number 3 Turn the front panel OUT dial left or right to move the cursor to each position 4 Press the OUT IN or ENTER pushbutton to confirm the IP address 5 Press ESC to return to the previous step without change Note The default IP address is 192 168 0 60 VMO808H User Manual Subnet Mask To set the VM0808H s Subnet Mask do the following 1 Select Subnet Mask from the Set IP Port submenu The cursor flashes on the first number ESC OUT IN MENU IP Address 192 168 0 60 s C subnet Mask 255 255 255 0 YJ omc PROFILE ENTER 2 Turn the front panel IN dial left or right to cycle through and change each number 3 Turn the front panel OUT dial left or right to move the cursor to each position
25. are 9600 19200 38400 and 115200 Press and release the OUT IN or ENTER pushbutton to confirm the Baud Rate Note The default baud rate is 19200 23 VMO808H User Manual Operation Mode The Power On Detection and EDID features are adjusted from the Operation Mode menu The Power on Detection mode automatically switches an Output port to the next powered on source if its video source is powered off EDID extended display identification data is used to automatically or manually setup different video configurations via EDID modes to utilize the best resolution across different monitors To adjust the Power On Detection or EDID mode from the Main page do the following Power on Detection 1 Use the MENU button to access the Menu page turn the OUT IN dial to scroll down and select ENTER Operation Mode MENU ESC fs gt operation Mode Cc Co PROFILE ENTER 2 With the arrow on Power On Detection press and release the OUT IN or ENTER pushbutton to access the Power On Detection options MENU ESC EUM Power On Detection ON 769 4 N EDID Default CI NL PROFILE ENTER 3 Turn the front panel OUT IN dial to cycle through On or Off 4 Press and Release the OUT IN or ENTER pushbutton to confirm the change 24 Chapter 3 Local Operation EDID 1 Use the MENU button to access the Menu page turn the OUT
26. e the device should not be placed in a built in enclosure unless adequate ventilation has been provided Never spill liquid of any kind on the device Unplug the device from the wall outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning The device should be operated from the type of power source indicated on the marking label If you are not sure of the type of power available consult your dealer or local power company The device is designed for IT power distribution systems with 230V phase to phase voltage To prevent damage to your installation it is important that all devices are properly grounded The device is equipped with a 3 wire grounding type plug This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not attempt to defeat the purpose of the grounding type plug Always follow your local national wiring codes Do not allow anything to rest on the power cord or cables Route the power cord and cables so that they cannot be stepped on or tripped over 53 VMO808H User Manual If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes To help protect your system from sudden trans
27. e connections can be changed simultaneously simply select all the connections you want to configure 2 Click the Submit button The display reloads with the new status changes Or click the Clear button to revert to the stored configuration Status Colors Connections display in colors to indicate their status as follows Gray Connected White Not Connected Note The latest connections will load automatically when the VM0808H is reset Chapter 4 Remote Operation Save Load Connection Profiles The VM0808H allows you to store up to 32 numbered 00 31 differently configured connection profiles that can be saved and recalled later by either connection method locally via the unit s front panel pushbuttons and over IP via the GUI Stored Profiles Save Use the Save button to save the current connection profile Use the drop down list to select a saved connection profile and then click the Load button to switch to that profile Note Profile 00 is the default Viewing Port Information The input ports can be sorted by port name or port number Use the drop down menu to select 00000000 Move your cursor over the Output Port number to see the port name displayed See Port Name page 38 for further information 35 VMO0808H User Manual Setup Click the Setup icon to configure the VM0808H s IP and serial settings and to name all the ports in your installatio
28. eath it From the Main screen you can set the Input to Output connections that route the signals from a selected Input port to the selected Output port To do so you simply change the Input source port associated for each Output display Profiles From the Main screen pressing the PROFILE pushbutton switches between the connection profiles added to the Profile Selection list see Profile Selection page 40 If a connection profile is in use it is shown from the main page on the lower right corner of the LCD display MENU ESC cnm OUTPUT 01 02 03 04 05 06 07 08 n ATEN INPUT 01 02 03 04 05 06 07 08 5 PROFILE ENTER Video In Selection To select which input source displays on each output port from the main screen do the following 1 Turn the OUT dial to select an output port s corresponding input port OUTPUT 01 02 03 04 05 06 07 08 eV iNPUT 02 04105 06 07 08 PROFILE ENTER 2 When the cursor highlights the selected input port you want to change use the IN dial to cycle through the available input sources Options are Ports 1 8 NA none 3 Press the OUT IN or ENTER pushbutton to confirm your selection The signal from the selected input port is now tied to the output port above it 4 Repeat steps 1 3 for all required ports 18 Chapter 3 Local Operation Set IP Port To configure the VM0808H s IP port settings from the Menu page turn the front panel O
29. el Operation page 15 Note The MENU and PROFILE front panel pushbuttons have built in LEDs that light to indicate they have been selected VMO0808H User Manual Rear View No Component Description 1 Power Socket This is a standard 3 pin AC power socket The power cord from an AC source plugs in here 2 Power Switch This is a standard rocker switch that powers the unit on and off 3 Grounding Terminal The grounding wire attaches here See Grounding page 11 for further details 4 Ethernet Port In order to access the VM0808H s Browser Graphical User Interface GUI the VM0808H must be connected to your network The cable that connects the VMO808H to your LAN plugs in here See Cable Connection page 12 for further details 5 HDMI Input Ports The cables from your HDMI source devices plug into these ports 6 HDMI Output Ports The cables from your HDMI display devices plug into these ports 7 External IR Receiver 3 5 mm Mini Stereo Jack which connects the IR Port Receiver unit included with your product 8 RS 232 Serial Port This serial remote port is for input source selection and high end system control Chapter 1 Introduction IR Remote Control 1 OUTPUT 2 3 No Component Description 1 Power ON OFF Use the ON and OFF pushbuttons to turn the Output displays on or off by individual port or all por
30. ers on a single rack or front stabilizers for joined multiple racks before working on the rack Always load the rack from the bottom up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a device from the rack Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent ofthe branch circuit rating Make sure that all equipment used on the rack including power strips and other electrical connectors is properly grounded Ensure that proper airflow is provided to devices in the rack Ensure that the operating ambient temperature of the rack environment does not exceed the maximum ambient temperature specified for the equipment by the manufacturer Do not step on or stand on any device when servicing other devices in a rack 55 VMO808H User Manual Technical Support International For online technical support including troubleshooting documentation and software updates http support aten com For telephone support see Telephone Support page iii North America Email Support support aten usa com Online Technical Support Troubleshooting Documentation Software Updates http www aten usa com support Telephone Support 1 888 999 ATEN ext 4988 When you contact us please have the following information ready beforehand Product model number
31. high quality cables of appropriate length since this will affect the quality of the audio and video display Contact your dealer to purchase the correct cable sets VMO0808H User Manual Source Device Operating Systems Supported operating systems are shown in the table below 05 Version Windows 2000 and higher Linux RedHat 6 0 and higher SuSE 8 2 and higher Mandriva Mandrake 9 0 and higher UNIX AIX 4 3 and higher FreeBSD 3 51 and higher Sun Solaris 8 and higher Novell Netware 5 0 and higher Mac OS 9 and higher DOS 6 2 and higher Chapter 1 Introduction Components Front View MENU ESC OUT IN Q Q Ca 2 PROFILE ENTER No Component Description 1 LCD Display The LCD display shows the various options for configuring and operating the VMO808H For full details see Front Panel Operation page 15 2 Front Panel Tuner Use the tuner dials and pushbuttons to navigate the Dials amp Pushbuttons LCD display to configure and operate the VM0808H MENU Press to invoke the Menu page Main Screen PROFILE Press to switch between the video source Profile Selection list ESC Press to cancel the current selection or exit without saving changes ENTER Press to confirm the current selection Tuner Dials IN amp OUT to navigate up down left and right or scroll selected options within the LCD display For full details see Front Pan
32. ient increases and decreases in electrical power use a surge suppressor line conditioner or un interruptible power supply UPS Position system cables and power cables carefully Be sure that nothing rests on any cables Never push objects of any kind into or through cabinet slots They may touch dangerous voltage points or short out parts resulting in a risk of fire or electrical shock Do not attempt to service the device yourself Refer all servicing to qualified service personnel If the following conditions occur unplug the device from the wall outlet and bring it to qualified service personnel for repair The power cord or plug has become damaged or frayed Liquid has been spilled into the device The device has been exposed to rain or water The device has been dropped or the cabinet has been damaged The device exhibits a distinct change in performance indicating a need for service The device does not operate normally when the operating instructions are followed Only adjust those controls that are covered in the operating instructions Improper adjustment of other controls may result in damage that will require extensive work by a qualified technician to repair 54 Appendix Rack Mounting Before working on the rack make sure that the stabilizers are secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabiliz
33. le 20 Profiles _ Profile 2 _ Brett Profile 22 Profile_7 Profile_23 u Profile 8 Profile 24 Profile 9 Profi le 25 Profile 10 Profil le_26 Profile 11 Profile 27 Profile 12 Profile 13 Profile 29 Profile 14 Profile 30 Profile 15 Profile 31 Profile Name Names can be the same Enter max 16 Characters Using 0 9 a z A Z _ Profile Name Enter name Click save to name the given profile number 41 VMO0808H User Manual User Management Click the User Management icon to add edit or delete user information and to change the passwords for accessing the VM0808H s GUI Note This is an Administrator only function Del aull user Admirastrator uver_i user_profile_i User uter_2 user_profile_2 Super User user 3 user profile 2 Administrator user user profile 4 User Add Edt Delete Operations are as follows Add User Click Add to add another user to the list The VM0808H supports up to 32 users at one time Edit User Use the radio button to select a user and click Edit to change the information This option allows an Administrator to rename the user set reset the selected user s password add a description of the user and to set the user s privileges See below for full details Delete User Select user and click Delete to remove all user information Continues on next page 42 Chapter 4 Remote Operation Add User
34. n IP Setup The Web Setup settings enable you to configure the VM0808H s Web interface connection Changes take a few seconds and automatically redirect you to the IP address specified Enter values and then click Save or Clear Click Default Setting to use the following defaults IP Address 192 168 0 60 Subnet Mask 255 255 255 0 Gateway 192 168 0 1 Website Timeout Smin iv MAC Address 00 10 74 9C 00 00 P Address 192 168 0 60 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 1 Website Timeout 5 minutes This option controls how long an inactive web connection stays logged in to the VM0808H Any changes will take effect immediately 36 Chapter 4 Remote Operation Serial Setup The Serial Setup settings enable you to configure the VM0808H s serial connection Use the drop down menu to select the value and then click Save or Clear Click Default Setting to use the following defaults Baud Rate 19200 v Baud Rate 19200 37 VMO0808H User Manual Port Name The Port Name page enables Administrators and Super Users to change the display name of the input and output ports To change the display name enter a value and click Save Click Clear to revert to the previous stored name Web Serial Port Name Input Num Input Name Output Name Port_In_1 Save Clear E P
35. not responsible for any damage incurred in the operation of this system if the correct operational voltage setting was not selected prior to operation PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE VMO808H User Manual Package Contents The VM0808H package consists of VMO808H 8x8 HDMI Matrix Switch Power Cord IR Remote Control IR Receiver Mounting Kit RM m m User Instructions Check to make sure that all the components are present and that nothing got damaged in shipping If you encounter a problem contact your dealer Read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit and or any of the devices connected to it Features may have been added to the VM0808H since this manual was printed Please visit our website to download the most up to date version Copyright 2010 2012 ATEN International Co Ltd Manual Part No PAPE 0349 AT1G Manual Date 2012 05 21 ATEN and the ATEN logo are registered trademarks of ATEN International Co Ltd All rights reserved All other brand names and trademarks are the registered property of their respective owners VMO808H User Manual Contents FCC Information eee eee eee eee ii fait shaded inet ii Sal a tu Riedie hake sitet eR dn usa ii SJ T 13364 2
36. nt page 42 for further information The same user can not be logged in simultaneously Note The VM0808H username supports lower case letters only 31 808 User Manual Connections Page The VM0808H s GUI main page is the Connections page This displays all active connections for control and configuration 32 Chapter 4 Remote Operation Toolbar Icon Description Connections This page displays the VM0808H s active connections and enables you to control them Setup This page enables you to configure the VM0808H s IP settings serial settings and port names Firmware The page enables you to upgrade the VM0808H s firmware Profile This page allows you to add delete Fri and name connection profiles to the Selection Profile List to use with the Et front pane PROFILE pushbutton User This page enables you to add edit and Management delete user information permissions and passwords Save Load This menu option allows you to save Profiles and load stored profiles Load Exit This icon ends the session and closes the Web interface 33 808 User Manual Configuring Connections To configure a connection from the connections page do the following 1 Select the radio button at the corresponding intersection of the input output ports you want to connect to connect each input source to an output display Note Multipl
37. ommand Port number Output Command Port Number Control Enter For example to switch input port 02 to output port 05 type the following sw i02 005 Enter 2 Switch Command Output Command Port Number Control Enter For example to turn off output on port 03 type the following sw 003 off Enter 3 Switch Command Output Command Port Number Control Enter For example to switch output port 04 to the next port type the following sw 004 Enter 45 VMO808H User Manual Possible Values The following table shows the possible values for switch commands Command Description sw Switch command Input Command Description i Input command Input Port Number Description 01 08 port default is 01 Output Command Description Output Command Output Port Number Description yy 01 08 port default is 01 All output ports Control Description on Turn on off Turn off Next port Previous port Enter Description Enter Enter and send out the command gt Chapter 5 RS 232 Commands Switch Port Command Table Cmd In 1 Out N2 c2 Enter Description sw i Enter Switch Input Port xx Key to Output Port yy 01 08 yy 01 08 sw Enter Turn on Output Port off Key yy Turn off Output Port yy yy 01
38. ort_In_2 Sa Clear Port_In_3 Save Clear Port_In_4 SEE Save Clear Port_In_5 Save Clear Port_In_6 Save Clear Port_In_7 Save Clear Port_In_8 Save Glean Clear ave Clear Clear Clear Clear 5 Clear Clear e Clear Max 16 characters only 0 9 a z A Z _ ePort Name Input Output Port Names can be the same Enter max 16 Characters Using 0 9 a z A Z _ eInput Name Enter name Click save to name the given port Output Name Enter name Click save to name the given port 38 Chapter 4 Remote Operation Firmware Click the Firmware icon to view information about the VM0808H s firmware version and to upgrade This is an Administrator function only 4r ln Ei a Enable to check firmware version V1 1 101 Filename Browse To upgrade the VM0808H s firmware do the following 1 Use the Browse button to locate the firmware upgrade file 2 Click Upgrade Firmware to start the upgrade Note Check the box to enable the utility to compare the VM0808H s current firmware version with that of the upgrade files If it finds that the VM0808H s firmware version is the same or higher than the selected upgrade version it brings up a dialog box informing you of the situation and gives you the option to Continue or Cancel 39 VMO0808H User Manual Profile Selection The profile selection page allows you to set a serie
39. put port status of each display using the IR remote control device included with your VM0808H You can use the remote control to change the Input source of any Output display power on off individual Output displays or power on off all Output displays simultaneously Before using the remote control you must first plug the IR External Receiver into the rear of the 808 and place the receiver where the IR signal can be reached see External IR Receiver Port page 6 Change the Input source of an Output display To change the Input source of an Output display with the remote control do the following 1 Press the OUTPUT port number 1 8 you want to change 2 Within 2 seconds press the INPUT port number 1 8 you want the OUTPUT port to display 3 Repeat steps 1 2 to change additional ports For the change to occur the INPUT must be pressed within 2 seconds of pressing the OUTPUT number Power on off individual Output displays To power on off individual Output displays with the remote control do the following 1 Press the OUTPUT port number 1 8 you want to power on off 2 Within 2 seconds press the ON or OFF pushbutton 3 Repeat steps 1 2 to change the power status back on off If the ON or OFF pushbutton is not pushed within two seconds of pushing the OUTPUT s port number all displays will be brought to a powered on or off status respectively 29 VMO0808H User Manual Power on
40. r 5 RS 232 Protocol Commands provides a complete list of the serial control protocol commands used when utilizing the RS 232 Serial Port so that an extra source device can function further as transmitter and receiver An Appendix provides specifications and other technical information regarding the VM0808H viii VMO808H User Manual Conventions This manual uses the following conventions Monospaced Indicates text that you should key in Indicates keys you should press For example Enter means to press the Enter key If keys need to be chorded they appear together in the same bracket with a plus sign between them Ctrl Alt Numbered lists represent procedures with sequential steps Bullet lists provide information but do not involve sequential steps Indicates selecting the option on a menu or dialog box for example that comes next For example Start Run means to open the Start menu and then select Run Indicates critical information Product Information For information about all ATEN products and how they can help you connect without limits visit ATEN on the Web or contact an ATEN Authorized Reseller Visit ATEN on the Web for a list of locations and telephone numbers International http www aten com North America http www aten usa com VMO808H User Manual This Page Intentionally Left Blank Chapter 1 Introduction Overview The ATEN VanCryst VM0808H
41. s of connections profiles that can be cycled through using the front panel PROFILE pushbutton Once you have added connection profiles to the Profile Selection List you can press the front panel PROFILE pushbutton to switch between the profiles which have been added to the Profile List Click the Profile icon to add delete or name connection profiles to the Profile Selection List Selection Name Add Delete Selection Profile To Add a profile to the Profile List do the following 1 From the Profile drop down menu select the connection profile 00 31 you want to add 2 Click the Add button By default new profiles are added to the bottom of the Profile List To Delete a connection profile from the Profile List do the following 1 Select the radio button of the profile you want to delete 2 Click the Delete button 40 Chapter 4 Remote Operation Profile Selection Name The Name page enables Administrators and Super Users to change the name of the selection profiles in the profile list To change the display name enter a value and click Save Click Clear to revert to the previous stored name Selection I Name Profile Num Profile Name Profile 0 _ Profile 16 Profile i Profle 37 Profile_2 Profile 18 Profile 3 Profile 19 Profile 4 Profi
42. the EDID of each connected display according to its connection when the VMO808H is first powered on or immediately after pressing ENTER to select the Remix option edid default Enter Key The default EDID will be passed to all video sources AR 8 Chapter 5 RS 232 Commands Mute Commands The formulas for Mute commands are as follows 1 Mute Command Output Command Port Number Control Enter For example to mute output port 05 type the following mute 005 on Enter 2 Mute Command Output Command Port Number Control Enter For example turn on audio at output port 05 type the following mute 005 off Enter Possible Values The following table shows the possible values for mute commands Commands Command Description mute Mute selected output port Control Description on Mute on audio from selected output port is disabled off Mute off audio output enabled default Mute Command Table Command Output Num2 Control Enter Description mute Enter Key Mute Output Port yy yy 01 08 Default mute off Enter Key Turn on Audio at Output Port yy yy 01 08 Default Note Each command string can be separated with a space 49 VMO808H User Manual Save Load Profile Commands The formulas for Save Load Profile commands are as follows 1 Command Profile N
43. three available levels are as follows Username user 1 Please enter 5 16 characters only 0 9 a z Password 000000000 Please enter 5 16 characters only 0 9 a z _ Confirm Password Please enter 5 16 characters only 0 9 a z _ Description user_profile_1 Max 16 characters only 0 9 a z A Z _ Status Administrator Add Edit Delete all users full rights Super User Full rights User Basic rights make ties save and recall the Profiles Administrator this level provides full access and control of the VMO808H functions in addition to full User Management privileges Super User this level provides full access and control with no User Management privileges User this level provides basic functions only create connections save and recall presets 44 Chapter 5 RS 232 Commands Serial Control Protocol Commands This chapter provides a complete list of the serial control protocol commands used when utilizing the RS 232 Serial Port so that an extra source device can function further as transmitter and receiver Configuring the Serial Port The controller s serial port should be configured as follows RS 232 Serial Control Protocol Settings Baud Rate 19200 Default Data Bit 8 bits Parity None Stop Bit 1 Bit Flow Control None Switch Port Commands The formulas for Switch Port commands are as follows 1 Switch Command Input C
44. ts see IR Remote Control Operation page 29 2 Output Pushbuttons Output display Pushbutton 1 8 to change an Input 1 8 source of an Output display see R Remote Control Operation page 29 3 Input Pushbuttons Input source Pushbutton 1 8 to change an Input 1 8 source of an Output display see R Remote Control Operation page 29 VMO808H User Manual This Page Intentionally Left Blank Chapter 2 Hardware Setup device is provided on page 53 Please review it before 1 Important safety information regarding the placement of this proceeding 2 Make sure that the power to all devices connected to the installation are turned off You must unplug the power cords of any computers that have the Keyboard Power On function Rack Mounting The VMO808H can be mounted in a 19 1U system rack For the most convenient front panel pushbutton configuration and operation at the local site mount the unit at the front of the rack as follows 1 Use the M3 x 8 Phillips head hex screws supplied with the Rack Mount Kit to screw the rack mounting brackets onto the front of the unit Phillips Head Hex M3 x8 Continues on next page VMO0808H User Manual 2 Position the unit in the front of the rack and align the holes in the mounting brackets with the holes in the rack 3 Screw the mounting brackets to the rack Chapter 2 Hardware Setup Grounding properly grounded 1
45. umber Control Enter For example to save the current connection configuration to profile 12 type the following profile f 12 save Enter 2 Command Profile Number Control Enter For example to load profile 12 type the following profile f 12 load Enter Possible Values The following table shows the possible values for Save load Profile commands Command Description profile Save Load profile Profile Description f Profile Profile Number Description yy 00 31 default is 00 Control Description save Save the current connection configuration load Load a saved profile a Chapter 5 RS 232 Commands Profile Command Table Command Profile Num1 Control Enter Description profile f yy save Enter Key Save current connection configuration to profile yy yy 00 31 Default 00 profile f yy load Enter Key Load saved profile yy yy 00 31 Default 00 Acknowledge Ack Description Command OK Command is correct and function executed Command Incorrect Unavailable command or parameters After commands are sent acknowledge messages are returned Power On Detection Commands The formula for the Power On Detection command is as follows 1 Command Control Enter For example to turn off the Power On Detection feature input the following pod off Enter Possible Values