Home
Valcom IP FlexHorn One-Way
Contents
1. VALCO IP lutions ISSUE 1 VIP 480L IP Paging Horn INTRODUCTION The VIP 480L IP Paging Horn is a self contained paging system which enables voice paging up to 1200 feet from an Ethernet connection The VIP 480L consist of a high efficiency 3 Watt Class D Horn and a VIP LLE Network Extender allowing stand alone capability when used with a SIP Phone System or can be accessed from a variety of Valcom managed VolP products SPECIFICATIONS Access Methods PBX FXO Port w VIP 811 POTS telephone set w VIP 811 PBX FXS Port w VIP 821 Valcom M Cast Page Group SIP Features e RJ 45 network connection e LED Status Indicator e Network activity LEDs e 802 3af compliant e High Efficiency Class D 3 Watt Amplifier Dimensions Weight HORN e 6 8 H x 8 3 W x 3 3 D 17 3cm H x 21 1cm W x 8 4cm D e 2 1 Ibs 0 95 kg Network Extender VIP LLE e 1 30 H x 6 10 W x 6 00 D 3 51 cm H x 15 72 cm W x 13 51 cm D e Weight 0 85 Ibs 0 39 kg Nominal Specifications HORN Input Impedance 600 Ohms Input Level 10dBm Output Impedance 600 Ohms Output Level 10dBm nominal Nominal Specifications VIP LLE Via 802 3af PoE Ethernet Switch Class 3 12 95W Environment Temperature 0 to 40 C Humidity 0 to 85 non precipitating Packing List Qty Item VIP LLE Network Extender 3 Watt High Efficiency Horn VSP Document Mounting Brackets VIP Quick Start Guide Rubber Feet Wood Screws RJ 45 Terminat
2. TECHNICAL ASSISTANCE Assistance in troubleshooting is available from the factory Call 540 563 2000 and press 1 for Technical Support or via email at support valcom com When requesting assistance you should include all available information Itis strongly suggested that you go to the web site and follow the trouble resolution procedure at http voip valcom com Valcom equipment is not field repairable Valcom Inc maintains service facilities in Roanoke VA Should repairs be necessary attach a tag to the unit clearly stating your company name address phone number contact person and the nature of the problem Send the unit to Valcom Inc Repair amp Return Dept 5614 Hollins Road Roanoke Va 24019 5056 947630 UNIVERSAL BRACKET SURFACE MOUNTED WITH A UNIVERSAL MOUNTING BRACKET NIVER ARBRAR EKET CUP C CLAMP FOR I BEAM MOUNTING ATTACH CLAMP TO HORN ATTACH FLEXHORN TO BEAM FLUSH MOUNT USING MOUNTING SCREWS J FLUSH MOUNTING IN A STUD WALL INSTALLED WITH MOUNTING SCREWS USING THE TEMPLATE MARK LOCATION OF OPENING AND MOUNTING HOLES ON WALL s lt HOLDING FLEXHORN FIRMLY AGAINST A FLAT OR CONSTRUCTION CEMENT DRILL HOLES APPROPRIATE TO MOUNTING SURFACE DRILL THROUGH EACH MOUNTING BOSS HARDWARE AND CUT OUT THE OPENING AS SHOWN PENDANT MOUNTING WITH OPTIONAL CHAIN AND EYE SCREW OTHER MOUNTING OPTIONS C C C OPTIONAL V 9805 VANDAL RESISTANT ENCLOSURE
3. Network Extender are four rubber stick on feet Peel these feet off their carrier backing and place at the four corners of the bottom of the unit Wall Using the brackets and wood screws provided secure the VIP LLE Network Extender to the wall Mounting HORN FLUSH MOUNT Using the template packaged with the speaker draw the speaker outline on the wall to be cut Make appropriate wiring connections and test the speaker for operation Using appropriate mounting screws not furnished drill and mount the flange as shown UNIVERSAL BRACKET Loosen or separate the universal bracket leaves by loosening or removing the handle and hardware Using the back leaf as a template mark the wall through the mounting holes drill and mount to the wall using appropriate screws not furnished or mount directly to a junction box Mount the T bracket to the back of the horn as shown using the 2 1 2 inch screws provided C CLAMP FOR I BEAM MOUNTING A C clamp is provided with the horn to allow mounting to a beam Place the bolt through the hole in the bottom of the base to secure the C clamp to the beam It is suggested that the horn be mounted to the underside of the I beam to provide maximum positioning adjustments Mount 2 1 2 inch screws provided Interconnections The only method of powering a VIP 480L IP Paging Horn is via a power over Ethernet switch or power injector meeting the 802 3af specificati
4. 4 947630 W BR PAIR RJ 45 VALCOM Termination Block Status were e Link A Act BL W x ZONA 9 BR GY 802 3af Compliant PoE Port 300 Max Distance OR BL WBL W O WGN WBR lt lt W BL W GN PAIR Amplified Paging Horn W O PAIR NOT USED 900 MAX DISTANCE CAT 3 5 6 FIGURE 1 VALCOM LIMITED WARRANTY Valcom Inc warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment The obligation under this warranty shall be limited to the replacement repair or refund of any such defective device within the warranty period provided that inspection by Valcom Inc indicates the validity of the claim the defect is not the result of damage misuse or negligence after the original shipment the product has not been altered in any way or repaired by others and that factory sealed units are unopened a service charge plus parts and labor will be applied to units defaced or physically damaged freight charges for the return of products to Valcom are prepaid all units out of warranty are subject to a service charge The service charge will cover minor repairs major repairs will be subject to additional charges for parts and labor This warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Valcom Inc be liable for any anticip
5. ated profits consequential damages loss of time or other losses incurred by the buyer in connection with the purchase operation or use of the product This warranty specifically excludes damage incurred in shipment In the event a product is received in damaged condition the carrier should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the F O B point Headquarters Valcom Inc 5614 Hollins Road Roanoke VA 24019 5056 Phone 540 563 2000 FAX 540 362 9800 5 947630
6. ion Block RJ 45 Patch Cable C Clamp Al D N a a oa 947630 INSTALLATION FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense Precautionary Designations CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION To reduce the risk of electric shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit Mounting VIP LLE The VIP LLE Network Extender is designed for wall or shelf mounting and must be within 300 feet of the network switch Shelf Provided with the VIP LLE
7. on Make all required signal connections before connecting to Ethernet switch or power injector meeting the 802 3af specification Power is supplied to the horn assembly via the VIP LLE Network Extender 947630 Network Connection Fig 1 The VIP LLE Network Extender has one CAT 5 RJ 45 NETWORK connector and one CAT 5 color coded connector on the rear panel Use the supplied CAT 5 patch cable to connect the NETWORK connector of the VIP LLE Network Extender to a 802 3af compliant PoE port 300 feet maximum distance Signal Connections Fig 1 Connect CAT 5 cable from the rear panel color coded connector of the VIP LLE Network Extender to the supplied RJ 45 terminal block 900 feet maximum distance Using the supplied CAT 5 patch cable to connect to RJ 45 connector to horn to RJ 45 termination block Status Indicator Lights The VIP LLE Network Extender has 3 status indication lights STATUS Flashes during normal operation and solid when unit in reset LINK Indicates 100 Mbit Ethernet connection when illuminated No activity indicates 10 Mbit connection ACT Indicator flashes to indicate network activity Operation Provides paging from SIP connection or from another Valcom VIP unit Interface to customer telephone system can be via SIP registration FXO port with VIP 811 or FXS port with VIP 821 VALCOM Status VIP LLE J Link Act Front View WBL WO WGN WBR ENEE Rear View
Download Pdf Manuals
Related Search
Related Contents
DISAG RM Ⅳ 操作手順 INDOOR SIREN Fondations profondes - dimensionnement et conception - BEEP-IRD Copyright © All rights reserved.
Failed to retrieve file