CyberPower PDU15SWV16FNET power distribution unit PDU

image

Contents

1. Power Cord AC Output Outlets Current Level Input Voltage Power Load Indicator Ethernet Port Tx Rx Indicator Serial PDU Status Screen Reset Button Rear panel description A Bracket Screw Hole B Keyhole Mount Peg Screw Hole Link Indicator Outlet Indicator switched series only ENVIROSENSOR Port RJ45 modular port Select Button Technical Specification Product Features OU 30A Series Front panel description NEMA Type IEC Type Power Cord AC Output Outlets Input Circuit Breaker Current Level Input Voltage Load Indicator Ethernet Port Outlet Indicator Serial Select Button PDU Status Screen Reset Button A gt B C D E F G H l J n l K B L Hen MES alo N 9 2420 O ole 10 Ole i 9 f Rear panel description Power A Bracket Screw Hole B Keyhole Mount Peg Screw Hole Tx Rx Indicator Link Indicator switched series only ENVIROSENSOR Port RJ45 modular port Technical Specification
2. Technical Specification Rear panel description Eo A Power Cord B AC Output Outlets C Current Level D Input Voltage E Power F Load Indicator j G Ethernet Port H Tx Rx Indicator 5 l Link Indicator A Bracket Screw Hole J Outlet Indicator B Keyhole Mount Peg switched series only Screw Hole K Serial ENVIROSENSOR Port aL RJ45 modular port i L Select Button 9 M PDU Status Screen ra N Reset Button ES l ni ppp 2 site ot Oore T re na 9 Bre Je jn dit H9 ni sa Switched Series 1U 20A Monitored Series 1U 20A Switched Series 0U 15A Monitored Series 0U 15A Model Name PDU15SWV16FNET PDU15MV16FNET Model Name EDUZOSWEENEL PDU20SWHVIEC8FNET POU OMSENET PDU20MHVIEC8FNET PDU20SWT8FNET PDU20MT8FNET Input Input Nominal Voltage 100 120V Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Frequency 50 60Hz Derated Input 12A Derated Input 16A Current Current Plug Type NEMA 5 15P Plug Type NEMA 5 20P mE NEMA 5 20P Eeoa Power Cord Type SR 14 AWG NEMA L5 20P NEMA L5 20P Power Cord 10 ft 3 05 m Power Cord Type SR 12AWG Socket SR 12 AWG Socket Length i Power Cord Output 12 ft 3 65 m 10 ft 3 05 m 12 ft
3. Switched Series 0U 20A Monitored Series OU 20A Switched Series 0U 30A Monitored Series 0U 30A Model Name PDU20SWVT24FNET PDU20SWVHVT24FNET PDU20MVT24FNET PDU20MVHVT24FNET Model Name PDU30SWVT24FNET PDU30SWVHVT24FNET PDU3OMVT24FNET PDU3OMVHVT24FNET Input Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Frequency 50 60Hz Derated Input Derated Input Current 16A Current dd Plug Type NEMA L5 20P NEMA L6 20P NEMA L5 20P NEMA L6 20P Plug Type NEMA L5 30P NEMA L6 30P NEMA L5 30P NEMA L6 30P Power Cord Type SR 12 AWG Power Cord Type SR 10 AWG Power Cord Power Cord 10 ft 3 05 m Length 10 ft 3 05 m Length i Output Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Derated Output 24A Current 16A Current Derated Output IEC 320 C13 21 IEC 320 C13 20 Outlet Type NEMA 5 20R IEC 320 C19 3 NEMA 5 20R IEC 320 C19 4 m 20A 15A 20A 15A Nemerng 24 2143 24 20 4 Bank Number 2 IEC 320 C13 21 IEC 320 C13 20 Protocol Support TCP IP UDP SNMP HTTP Outlet Type NEMA 5 20R IEC 320 C19 3 NEMA 5 20R IEC 320 C19 4 Connectivity uas Outlet Number 24 2148 24 2044 Physical Circuit Breaker Yes HIE 66 53 x 2 20 x 1 75 1690mm x 56mm x 44mm Networking XWxD Protocol Support TCP IP UDP DHCP SNMP HTTP Environmental Connectivity RJ45 Humidity 0 to 95 Non condensing Physical Altitude
4. eese ux rA Metered Readout eese seen enee entente 17 Basic Operation zi ceia eiii t erede PDU Status Screen a Current Level intrent a a al Input Voltage Power IP Address Outlet Control Switched series only 17 LED Reversal OU series only 17 Environmental Monitoring optional 18 LED Indicators ritieni rnt annm 18 Device Reset ouuuuooeocononenonneneaeeeaneneneaneaeaeneaneneanenaaeaese 18 Remote Management cessent 18 Unattended Automatic Shutdown 19 Firmware Upgrade eee 19 Troubleshooting eee 20 Frequently Ask Questions FAQ 20 Conformance Approvals Customer Service amp Warranty 21 Product Registration eec esie 21 CyberPower International ase Limited Warranty i i c toin ois ek cha tei tra Darei caina tea 21 Appendix A Hyper Terminal 22 Appendix B Power Device Network Utility 23 OVOIVIOW m 23 Installation orte tnr rre eme 28 launch Program css nre nier rtr enne 24 Getting Started m Advanced SENNY Soneira 25 Model List 1U Switched Series PDU15SWSFNET PDU15SWHVIEC8FNET PDU20SWSFNET PDU20SWTSFNET PDU20SWHVIEC8FNET 1U Monitored S
5. CyberPower Reliability Quality Value User Manual Power Distribution Unit e CyberPower Reliability Quality Value www CPSww com K01 0000181 02 Table of Contents Model List seaca oua ai aaa ian aaa 1 Introduc ion nica aaa hens oaia ian inimioara 1 Package Contents nea inecat anale piese ceea ina iai cn 1 FOr IU S l6 5s d l ni ninen ae re ERE EE 1 For 0U Series For 2 Seres x ds dra nn err Safety Precautlons eie cai dee ataca aaa ia Product Features 2 TU 5A SONOS onn errare nie rrt Technical Specification cauri niea 4 1U 20A Series Technical Specification esssssse OU TSA Sor OS xinin n y ciza pine Pere Technical Specification OU 20A Series nicer ees Technical Specification sssessse OU 30A Series Technical Specification esssssss 2U Series eon nre ra rer ct ees 9 Technical Specification sess 9 Installation Guide esses 10 Horizontal Iristallation erre 10 For 1U Model For 2U Model Vertical Installation ss For 1U Model id For OU with Bracket id For OU with Keyhole Mount 2 15 Electrical Installation 15 Network Installation Operation
6. d o A Power Cord B AC Output Outlets C Current Level D Input Voltage E Power F Load Indicator G Ethernet Port H TX Rx Indicator Rear panel description o Link Indicator J Outlet Indicator switched series only K Serial ENVIROSENSOR Port RJ45 modular port Select Button M PDU Status Screen N A External Site Ground Technical Specification Reset Button 4 Switched Series 1U 15A Monitored Series 1U 15A Model Name PDU15SW8FNET PDU1SSWHVIEC8FNET PDU15M8FNET PDU15MHVIEC8FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input Current P 12A 12A UL 10A CE 12A 12A UL 10A CE Plug Type NEMA 5 15P IEC 320 C14 NEMA 5 15P IEC 320 C14 Power Cord Type SR 14 AWG Socket SR 14 AWG Socket Power Cord 12 ft 3 65 m 10 ft 3 05 m 12 ft 3 65 m 10 ft 3 05 m Length Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output 12A 12A UL 10A CE 12A 12A UL 10A CE Current Outlet Type NEMA 5 15R IEC 320 C13 NEMA 5 15R IEC 320 C13 Outlet Number 8 Networking Protocol Support TCP IP UDP DHCP SNMP HTTP Connectivity RJ45 Physical rote 1 75 x 17 05 x 4 41 44mm x 433mm x 112mm Environmental Humidity 0 to 95 Non condensing Altitude 14700 ft 4500 m Temperature 32 F to 104 F 0 C to 40 C Safety Approvals UL 60950 1 UL 60950 1 UL
7. to the PDU Step 2 PDU Mounting Align the Keyhole Mounts to the Keyhole Slots on the rack Insert and slide down to lock firmly into the place Electrical Installation Step 1 Receptacle evaluation Ensure that the plug type of your PDU unit matches the wall receptacle type that you are using The PDU must be plugged into a three wire grounded wall receptacle only The wall A receptacle must also be connected to an appropriate branch circuit main with fuse or CAUTION circuit breaker protection Connection to any other type of wall receptacle may result i in a shock hazard Step 2 Plug the PDU into the wall receptacle 15 For information on CyberPower products visit www CPSww com Installation Guide Step 3 Attach equipment It is extremely important not to exceed the PDUs maximum current load as outlined in the Specifications section In order to determine your total load simply use the Metered Readout on the front of the PDU Network Installation Step 1 Attach the LAN Cable Using a CAT5 RJ45 cable attach one end to the Ethernet port on the front of the PDU and the other end to a network port Step 2 Establish the PDU IP address Assigning an IP address to the CyberPower PDU requires the user to have an available IP address that is valid on the respective network If an available IP address is unknown contact the network administrator to obtain one The default IP is 192 168 2
8. 60950 1 UL 60950 1 Certifications CSA C22 2 CSA C22 2 CSA C22 2 CSA C22 2 FCC Class A CE FCC Class A FCC Class A CE FCC Class A Warranty Product Warranty 3 years For information on CyberPower products visit www CPSww com 4 Product Features 1U 20A Series Front panel description NEMA Type 9 9 e s E EA E E EA E a a O cal lea la es aq ie ia 49 01 02 03 O4 O5 O6 97 os 9 IEC Type e Q Honma 01 02 93 92 95 o6 07 9 8 9 o A Power Cord Link Indicator B AC Output Outlets C Current Level D Input Voltage E Power F Load Indicator G Ethernet Port H Tx Rx Indicator Rear panel description J Outlet Indicator switched series only K Serial ENVIROSENSOR Port RJ45 modular port L Select Button M PDU Status Screen N Reset Button A External Site Ground Technical Specification Product Features OU 15A Series Front panel description
9. Configure System to Default Sure to Configure System to Default 1 Yes 0 NO For information on CyberPower products visit www CPSww com 22 Appendix B Power Device Network Utility Overview The CyberPower Power Device Network Utility is an easy to use interface which is used for establishing IP addresses on CyberPower PDU devices e Installation Step 1 Insert the CD labeled PDU Software Installation CD into the CD DVD drive Step 2 Select Power Device Network Utility from the installation menu Shown in Figure 1 AER The PDU Power Distribution Unit allows administrators an easy way to control AC power for various connected devices via network Installing the below software helps users to strengthen the PDU functions Power Device Network Utility The Power Device Network Utility gives users an easy to use interface to establish SNMP and network settings on the PDU Install Power Device Network Utility PowerPanel Business Edition PowerPanel Business Edition provides the capability of unattended automatic shutdown of connected PCs servers to the PDU Install PowerPanel Business Edition Read Installation Guide Browse this CD Figure 1 Installation Menu Step 3 Select Next in the software wizard Step 4 Choose an installation directory and user settings Select Next Shown in Figure 2 i Power Device Network Utility Select Installation Folder The installer will install Power Device
10. ESTATOORUASODIRIS Dimension 70 x 2 20 x 1 75 66 53 x 2 20 x 1 75 Temperature 32 F to 104 F 0 C to 40 C HxW xD 1778mm x 56mm x 44mm 1690mm x 56mm x 44mm Safety Approvals Environmental Certifications UL 60950 1 CSA C222 FCC Class A Humidity 0 to 95 Non condensing Warranty Altitude 14700 ft 4500 m Product Warranty 3 years Temperature 32 F to 104 F 0 C to 40 C Safety Approvals Certifications UL 60950 1 CSA C22 2 FCC Class A Warranty Product Warranty 3 years e For information on CyberPower products visit www CPSww com For information on CyberPower products visit www CPSww com 8 Product Features 2U Series Installation Guide Front panel description NEMA Type CAUTION Please use only the provided screws through the entire installation process Horizontal Installation For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU A Power Cord J Link Indicator B AC Output Outlets K Outlet Indicator C Input Circuit Breaker switched series only D Current Level L Serial ENVIROSENSOR Port E Input Voltage RJ
11. Network Utility to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder je AProgram Files CyberPower Power Device Network Utility Install Power Device Network Utility for yourself or for anyone who uses this computer O Everyone Just me Cancel Figure 2 Installation folder and settings Step 5 Select Next to comfirm the settings and install Step 6 Select Close to finalize the installation 23 For information on CyberPower products visit www CPSww com Appendix B Power Device Network Utility e Launch Program To launch the Power Device Network Utility and get started select Programs from the Start menu in Windows and locate the new folder and icons for Power Device Network Utility Select Power Device Network Utility from the program folder Shown in Figure 3 Internet set Program Access and Defaults Internet Explorer W Windows Catalog E mail Outlook Express AB Windows Update Accessories E Games Ei Microsoft Platform SDK for Windows Server 2003 R2 8 startup Internet Explorer Windows Media Player 148 Windows Messenger Tour Windows XP Windows Movie Maker Debugging Tools for Windows All Programs fa c P k Utili i Power Device Network Utilty Help Figure 3 Power Device Network Utility e Getting Started The Power Device Network Utility scans the network for d
12. you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a purchase receipt or other proof of the original purchase and provide a description of the defect What Will We Do To Correct Problems CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our liability is limited to the amount if any stated in the Technical Specifications Who pays for shipping We pay when we send ite
13. 0 177 and the default DHCP function is on There are multiple methods for setting up the IP address on the PDU Please follow the instructions below for the method that is appropriate for your application Please make sure the PDU is powered on during this process Option 1 recommended Power Device Network Utility 1 Use the included PDU Software Installation CD to install the Power Device Network Utility program 2 Open the Power Device Network Utility software Start gt Power Device Network Utility 3 Highlight the PDU device from the list and select Edit and Setup device gt Assisted Setup from the menu 4 Configure the IP Address Subnet Mask and Gateway Address to match your network settings 5 Enter the user name and password of the PDU device at the Authentication menu Note The default username is cyber and the default password is cyber For further information and installation instructions see Appendix B Option 2 DHCP Server 1 Ask your administrator if there is DHCP server on the LAN 2 Make sure the DHCP is Enabled 3 Make sure the network connection is ready and power on the PDU 4 The PDU will obtain an IP address from the DHCP server automatically Option 3 Address Resolution Protocol ARP Command 1 Obtain the MAC address from the sticker on the PDU 2 Open a command prompt as an administrator and type the following arp s available IP address MAC address of PDUJ Example arp s
14. 192 168 20 240 00 0c 15 80 00 01 IP Address MAC Address 3 Use the Ping command to assign a size of 123 bytes to the IP Type in ping 192 168 20 240 I 123 then press Enter fthe replies are received your computer can communicate with the IP address Option 4 Hyper Terminal or Terminal Emulator In order for Hyper Terminal to interface with the PDU the PC server must be connected directly to the PDU via the serial port 1 Use the included RJ45 DB9 serial port connection cable attach one end to the serial port on the front of the PDU and the other end to the PC server 2 Open the Hyper Terminal software on your PC and select a name and icon for the connection 3 Setup the COM port settings using the following values Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None For information on CyberPower products visit www CPSww com 16 Installation Guide 4 Type setup and press Enter to enter the Authentication menu 5 Enter the user name and password of the PDU device at the Authentication menu Note The default username is cyber and the default password is cyber For further information and configuration via Hyper Terminal see Appendix A Hyper Terminal Operation Metered Readout The Metered Readout provides instant status updates of the AE PDU s Voltage Current Power conditions as well as the local IP address of the unit to the user In addition it also allows
15. 3 65 m 10 ft 3 05 m Length Nominal Voltage 100 120V Output Derated Output 12A Nominal Voltage 100 120V 200 240V 100 120V 200 240V Current Derated Output 16A Outlet Type NEMA 5 15R Current Outlet Number 16 Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R IEC 320 C13 Networking Outlet Number 8 Protocol Support TCP IP UDP DHCP SNMP HTTP Networking Connectivity RJ45 Protocol Support TCP IP UDP DHCP SNMP HTTP Physical Connectivity RJ45 Dimension Physical HxWxD 49 x 2 20 x 1 75 1245mm x 56mm x 44mm Dimension 1 75 x 17 05 x 4 41 44mm x 433mm x 112mm Environmental Hx W xD Humidity 0 to 95 Non condensing Environmental Altitude 14700 ft 4500 m Humidity 0 to 95 Non condensing Temperature 32 F to 104 F 0 C to 40 C Altitude 14700 ft 4500 m Safety Approvals Temperature 32 F to 104 F 0 C to 40 C Certifications UL 60950 1 CSA C222 FCC Class A Safety Approvals Warranty UL 60950 1 UL 60950 1 UL 60950 1 UL 60950 1 Product Warranty 3 years Certifications CSA C222 CSA C22 2 CSA C22 2 CSA C22 2 FCC Class A CE FCC Class A FCC Class A CE FCC Class A Warranty Product Warranty 3 years 5 For information on CyberPower products visit www CPSww com For information on CyberPower products visit www CPSww com 6 Product Features OU 20A Series Front panel description NEMA Type IEC Type cC IQ0mnmoour er D a a E ppm ia
16. 45 modular port F Power M Select Button G Load Indicator N PDU Status Screen H Ethernet Port O Reset Button Tx Rx Indicator Rear panel description If you plan on attaching the Cord Retention Tray to the PDU you will need to use the LONG Mounting Brackets 2 Q4 x o A External Site Ground Technical Specification Switched Series 2U Monitored Series 2U Model Name PDU30SWT16FNET PDU30SWHVT16FNET PDUSOMT16FNET PDUSOMHVT16FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency 50 60Hz Derated Input 24A Current Step 2 PDU Mounting Plug Type NEMA L5 30P NEMA LG 30F NEMA E SUR NEMA L6 50 Use the supplied Washers 4 and Screws 4 to secure the PDU to Power Cord Type SR 10 AWG inis Power Cord your existing rack system Length Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Derated Output Current Derated Output Current 20A 15A 20A 15A each bank Bank Number 2 10 ft 3 05 m 12 ft 3 65 m 24A IEC 320 C13 12 IEC 320 C19 4 Outlet Number 16 Jj Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R E CR Circuit Breaker Yes Networking LN we Protocol Support TCP IP UDP DHCP SNMP HTTP 9 Connectivity RJ45 S Physical S Dimension 3 5 x 17 05 x 4 41 88mm x 433mm x 112mm 9 HxW xD o Environmental Humidity 0 to 9
17. 5 Non condensing Altitude 14700 ft 4500 m 9 Temperature 32 F to 104 F 0CC to 40 C Safety Approvals Certifications UL 60950 1 CSA C22 2 FCC Class A Warranty Product Warranty 3 years 9 For information on CyberPower products visit www CPSww com For information on CyberPower products visit www CPSww com 10 Installation Guide Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the 4 supplied Cord Retention Tray Mounting Screws Use the provided Cable Ties to fasten each cord to the Cord Retention Tray E 999992 For 2U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the Mounting Brackets 2 to the PDU 11 For information on CyberPower products visit www CPSww com Ce o 9 o o o o o fj Installation Guide Step 2 PDU Mounting Use the supplied Washers 4 and Screws 4 to secure the PDU to your existing rack system jeeoecoco s Q ooooocccooooo00000990 09oocoooooctvvvvvvvo Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the 8 supplied Cord Retention Tray Mounting Screws Use the provided Cable Ties to fasten each cord to the Cord Retention Tray eeooocococ000099090909990 For information on CyberPower products visit www CPSww com 12 Installation
18. Guide Vertical Installation 1U OU Model Only For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU Step 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system 90000000000 99600000000000000000000000000000000000000000000000000000000000 4 9000000000000000000 d UVP For 0U Model with Bracket Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 4 to attach the Mounting Brackets 2 to the PDU 13 For information on CyberPower products visit www CPSww com Installation Guide Step 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system 300000000000000000000000000000000000000000000 WO000000 900000000000000000000000090090000000000000000000000000000000000 Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the supplied Cord Retention Tray Mounting Screws Use the provided Cable Ties to fasten each cord to the Cord Retention Tray For information on CyberPower products visit www CPSww com 14 Installation Guide For 0U Model with Keyhole Mount Step 1 Keyhole Mount Installation Use the provided Screws 2 to attach the Keyhole Mounting Pegs 2
19. e Select button once and the square will move to the lower right After 1 second the outlet will turn off Amps Volts KW e LED Reversal 0U series only The LED status screen can be set to display upside down from standard through the Web Interface as shown in figures below Note the decimal point will not be moved and will instead be on the top if this option is enabled 17 For information on CyberPower products visit www CPSww com Operation Environmental Monitoring optional CyberPower PDUs along with the environment sensor ENVIROSENSOR provide the function of temperature and humidity monitoring in a server closet and or datacenter remotely To connect the PDU with ENVIROSENSOR use the RJ45 Ethernet Cable Plug one end into the Serial ENVIROSENSOR port on the PDU and the other end into the RJ45 port on the ENVIROSENSOR as shown in figures below When the PDU correctly connects to the ENVIROSENSOR users can see the temperature and humidity data on the Web Interface For further information regarding ENVIROSENSOR configuration please refer to the PDU Software Installation CD LED Indicators Indicator Status Description Green The total PDU power load is normal Load Orange Near overload Red Overload Off The PDU power is off On Green The PDU power is on Tx Rx Receiving transmitting data packet Flash Reset fin
20. een unblock R When should unblock a program Figure 5 Windows Security Alert For information on CyberPower products visit www CPSww com 24 Appendix B Power Device Network Utility Step 2 Assign a valid IP Address to the PDU Option 1 Assisted Setup recommended With the appropriate device selected from the Equipment List open the Network Settings menu Shown in Figure 6 Tools gt Device Setup In the Device Network Setting Menu enter a valid IP address subnet mask and gateway address to setup the PDU device Device Network Settings Device MAC Address 00 0C 15 40 08 A9 UsingDHCP Oves GNo IP Address 192 168 24 Subnet Mask 255 265 255 Gateway 192 168 24 Figure 6 Network Setting Menu Device Setup Note The DHCP option is not available for all power devices Step 3 Authentication Enter the user name and password of the PDU device at the Authentication menu Shown in Figure 7 Note The default username is cyber and the default password is cyber Authentication Enterthe user name and password to save changes uS Figure 7 Authentication screen Advanced Settings Timeout Settings The Timeout Setting Shown in Figure 8 Edit gt Timeout Settings is used to specify the wait time when scanning for network PDU devices When there are many devices on the local network it may take extended periods of time to locate all the devices The timeout fu
21. eries PDU15MSFNET PDU15MHVIEC8FNET PDU20M8FNET PDU20MT8FNET PDU20MHVIEC8FNET OU Switched Series PDU15SWV16FNET PDU20SWVT24FNET PDU20SWVHVT24FNET PDU30SWVT24FNET PDU30SWVHVT24FNET Introduction OU Monitored Series PDU15MV16FNET PDU20MVT24FNET PDU20MVHVT24FNET PDU30MVT24FNET PDU30MVHVT24FNET 2U Switched Series PDU30SWT16FNET PDU30SWHVT16FNET 2U Monitored Series PDU30MT16FNET PDU30MHVT16FNET Package Contents For 1U Series PDU D Mounting Bracket 2 short amp 2 long vy ap To e ap 10 Flat Head M4x8 Bracket Mounting Screws Includes two spares Cord Retention Tray M WHE Cable Ties Qty 10 gaa AA PPPLPPP e 6 M3x6 Cord Retention Tray Mounting Screws Includes two spares 99699993 PPPLPPP lt 6 M5x12 Screws 6 Washers Includes two spares for each RJ45 DB9 Serial Port Connection Cable Power Cord 10 feet IEC 320 C13 IEC 320 C14 PDU15SWHVIEC8FNET PDU15MHVIEC8FNET Model Only es Power Cord 10 feet IEC 320 C19 IEC 320 C20 PDU20SWHVIEC8FNET PDU20MHVIEC8FNET Model Only User Manual Registration Card CD Documentation 1 For information on CyberPower products visit www CPSww com Introduction Package Contents For OU Series 16 Outlets 24 Outlets ep 6 Flat Head M4x4 Bracket Mounting Screws Includes two spares Cord Retention Trays Qty 2 16 Outlets Qty 3 24 Outlets M HAZ Cable Ties Qt
22. evices with MAC addresses that match CyberPower network hardware Once found the device s can then be figured with a specific IP address subnet mask and gateway address This allows the device s to function properly on the network and interface with CyberPower Management Console Step 1 Select the appropriate PDU device from the Equipment List Shown in Figure 4 Power Device Network Utility Fie Took Help Power Devices MAC Address IP Address Subnet Mask Gateway DHCP Nam g00 0C 15 40 09 A9 1921682420 2552552550 19216824254 Enable PDU2 Figure 4 Equipment List Note If the PDU does not appear on the list click the Refresh button to rescan the network If it still does not appear ensure that the PDU is turned on and was installed correctly Pressing Stop will cancel the scan refresh process Note If your computer has a software firewall installed you may see a Windows Security Alert message Shown in Figure 5 In Windows XP SP2 the default firewall alert message is shown as Figure 5 You need to allow the Power Device Network Utility access through the firewall Windows Security Alert x 7 To help protect your computer Windows Firewall has blocked NJ some features of this program Do you want to keep blocking this program Name Power Device Network Utility Publisher Unknown Windows Firewall has blocked this program from accepting connections from the RET d SERO i eu esr MO POON Oe Pater s
23. he Power Distribution Units PDU e Use only the supplied hardware to attach the mounting brackets e The PDU must be plugged into a three wire grounded outlet on a circuit that is protected by a fuse or circuit breaker For PDU15xxxxx series please use 15A circuit protector For PDU20xxxxx series please use 20A circuit protector For PDU30xxxxx series please use 30A circuit protector Connection to any other type of power outlet may result in a shock hazard Do not use extension cords or adapters with this PDU e Never install a PDU or associated wiring or equipment during a lightning storm e Ensure that the power cord plug and socket are in good condition To prevent the risk of fire or electric shock this PDU should be installed in a temperature CAUTION and humidity controlled indoor area free of conductive contaminants Do not install this PDU where excessive moisture or heat is present 3 For information on CyberPower products visit www CPSww com Product Features 1U 15A Series Front panel description NEMA Type o J o oO o IEC Type o FIVE 8 5 E25 8 5 625 O1 02 o3 O4 O5 06
24. iance must be specified in the instruction This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice 1 An unshielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception It is essential that only the supplied power cord by used 2 Use only shielded cables to connect I O devices to this equipment Note THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT The Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulation Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada For information on CyberPower products visit www CPSww com 20 Customer Service amp Warranty Product Registration Thank you for purchasing a CyberPower product Prompt product registration entitles coverage under the Limited Warranty and also allows the opportunity to be notified of product enhancements upgrades and other announcements Registration is quick and easy at www cpsww com s
25. ished On Indicates the PDU is connected to the LAN LINK Indicates the PDU is not connected to the Off LAN On The outlet is on and providing power Outlet Off The outlet is off Device Reset Toreset all the settings to default except for the IP address press and hold the Reset Button for 3 seconds To reset all the settings to default press and hold the Reset Button for 6 seconds Remote Management The remote management function of the CyberPower PDU provides for monitoring the PDU vitals controlling outlets and utilizing SNMP functionality Remote management is performed via the web interface To access the web interface please follow the instructions below 1 Enter the IP address of the PDU into a web browser Internet Explorer Firefox 2 Enter the user name and password of the PDU device at the authentication screen Note The default username is cyber and the default password is cyber For additional information about the features and functionality of CyberPower Management Console please refer to the PDU Software Installation CD For information on CyberPower products visit www CPSww com 18 Operation Unattended Automatic Shutdown PowerPanel Business Edition software automatically saves open files and gracefully shuts down the operating system in an intelligent and orderly fashion PowerPanel must be installed on every PC for which the shut down is to take place The PC receives SNMP
26. messages directly from the PDU and these messages can be scheduled for an exact date time or can be performed immediately Follow the directions below for setting up Unattended Automatic Shutdown Step 1 PC Configuration 1 Install PowerPanel Business Edition Client on every PC that will be part of the shut down process Follow the instructions in the PowerPanel Business Edition Client user manual 2 Configure the settings in PowerPanel Business Edition Client See the PowerPanel Business Edition Client User Manual for additional help Step 2 PDU Configuration 1 Verify that the IP address of all PCs that will be part of the shut down process are included in the Client List of web interface For additional information please refer to the user s manual in the PDU Software Installation CD Step 3 Notification Notifying the PCs of potential outlet shutdown can be accomplished using the following methods e Outlets Control Menu Performing the task of turning off or rebooting outlets e Scheduling Menu Setting the scheduler to perform the task of turning off or rebooting outlets The notification will occur prior to the scheduled date time e Outlet Overload In event of a PDU overload notification will be sent prior to the PDU shutting down Firmware Upgrade By upgrading the Firmware you can obtain new features and updates improvements to existing functionality There are two files to update in order to upgrade the firmware ve
27. ms to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that is damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or apply to misuse modification operation or Storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life Support devices etc 21 For information on CyberPower products visit www CPSww com Customer Service amp Warranty What are the Limitations 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge
28. nction is used to limit the search time The default setting is 3 seconds Valid values are 3 to 60 seconds Timeout Setting The time to wait all devices response in s g seconds Figure 8 Timeout Setting 25 For information on CyberPower products visit www CPSww com
29. remains contact 2 Loose power cord tech support Amperage displayed on Metered Readout 1 Overload exceeds the units capability The load indicator shows red when overload Reduce the load on the PDU until the overload is gone If the problem remains contact technical support 1 Sustained overload Reset Breaker Circuit breakers have tripped If the problem remains contact technical 2 Excessive ambient or internal temperatures support 3 Faulty breaker Frequently Ask Questions FAQ Q What do do if I ve lost the Administrator username and or password A Resetting the PDU will set the username and password back to system default Please see the Device Reset section to reset the PDU Conformance Approvals FCC Warning WARNING This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any special accessories needed for compl
30. rsion cpspdubfw XXX bin cpspdubdata_XXX bin Use the following steps to upgrade the firmware Download the latest firmware from cpsww com Extract the file to C Open a command prompt window Login to the PDU with FTP command type ftp ftp open To current IP of the PDU port for example To 192 168 22 126 21 Input USER NAME and PASSWORD same as the administrator account in Web interface default cyber cyber 5 Upgrade the cpspdubfw XXX bin type ftp gt bin ftp gt put cpspdubfw XXX bin 6 Upgrade complete type ftp gt quit 7 The system will reboot after you type quit 8 Login to the FTP again ftp ftp open To current IP of the PDU port for example To 192 168 22 126 21 Input USER NAME and PASSWORD 9 Input USER NAME and PASSWORD Upgrade cpspdubdata XXX bin ftp gt bin ftp gt put cpspdubdata XXX bin 10 Upgrade complete type ftp gt quit 11 The system will reboot after you type quit Bom You can check to see if the firmware upgrade is successful by checking the Firmware version on the System gt About webpage Note Please do not turn the PDU off when processing the Firmware upgrade 19 For information on CyberPower products visit www CPSww com Troubleshooting Problem Possible Cause Solution PDU outlets do not provide power to connected equipment 1 Breaker tripped Reset Breaker check if plug is completely connected If the problem
31. suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Product must have been used at all times within the limitations on the Product s VA capacity 5 The sole and exclusive remedies of the Initial Customer are those provided by this Warranty Appendix A Hyper Terminal Hyper Terminal software can be used for basic PDU configuration It utilizes a text based interface and menu system Navigation through the interface is done by typing the number of the menu option and pressing the Enter key Note The session will timeout and logout after 3 minutes of inactivity Menu options are shown below Main Menu Network Settings System Configuration Account Settings Configure System to Default Logout O SO N Network Setting Physical MAC Address 00 0C 15 40 08 A9 1 System IP 192 168 24 20 Subnet Mask 255 255 255 0 Default Gateway 192 168 24 254 DHCP Enable Http Port 80 Http Access Enable 9 O1 N System Configuration Date mm dd yyyy 11 11 2011 Time hh mm ss 17 17 25 Name PDU20SW8FNET Contact Administrator Location Server Room O SO N Account Setting 1 Administrator 2 Viewer Web Only
32. the user to control each outlet of the PDU Basic Operation Screen Selection To toggle the different status screens press the Select button next to the PDU status screen e Pressing the Select button once will toggle to the next status screen e Pressing and holding the Select button for 3 seconds will display the local IP address of the unit e Pressing and holding the Select button for 6 seconds will enter the outlet control mode PDU Status Screen Current Level s The Current Level screen shows the total current draw of the connected equipment Units are listed in Amps e Input Voltage The Input Voltage screen measures the AC voltage that the Sr system is receiving from the utility wall receptacle This can Kw be used as a diagnostic tool to identify poor quality input power Units are listed in Volts e Power Anis The Power screen shows the total power that the devices Volts connected to the PDU consumes Units are listed in kilowatts KW IP Address Amps The IP Address screen displays the local IP address of the ies PDU unit Note If the PDU is not connected to a LAN the readout will display the default IP address Outlet Control switched series only Amps The Outlet screen shows the condition of each outlet in S 5 sequence When the outlet is on the light below this outlet will be on and a square appears in the upper right area next EA to the number of the outlet To switch the outlet off press th
33. upport warranty registration html e CyberPower International Feel free to contact our Tech Support department with installation troubleshooting or general product questions CyberPower North America Phone 952 403 9500 Toll free 877 297 6937 Email tech cpsww com Web www CPSww com Add 4241 12th Avenue E Suite 400 Shakopee MN 55379 Hours of Operation Monday Friday 8 00 AM 5 00 PM CST CyberPower Europe Email sales cpsww eu Web www cpsww eu Limited Warranty Read the following terms and conditions carefully before using the CyberPower PDU series By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it Who Is Providing This Warranty CyberPower Systems USA Inc CyberPower Europe CyberPower provides this Limited Warranty What Does This Warranty Cover This warranty covers defects in materials and workmanship in the Product under normal use and conditions What is the Period of Coverage CyberPower provides a 3 Year warranty to the original purchaser who owns the Product Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 You can use the contact information mentioned above for instructions 2 When
34. y 20 16 Outlets Qty 30 24 Outlets rrr 9 rrr 9 Cord Retention Tray Mounting Screws M3x6 Qty 10 for 16 Outlets Qty 14 for 24 Outlets Includes two spares rr rr F 6 M5x12 Screws 6 Washers Includes two spares for each rr amp 2 Keyhole Mounting Pegs with 4 M4x5 Screws Includes two spares RJ45 DB9 Serial Port Connection Cable User Manual Registration Card CD Documentation For information on CyberPower products visit www CPSww com Introduction Package Contents For 2U Series PDU di di did 8 09 9 9 Mounting Brackets x 2 10 M3x6 Cord Retention Tray Mounting Screws P gt Includes two spares q t ue ts 000000 Qi Od ae rr rr 9 P 10 Flat Head M4x8 Bracket Mounting Screws Includes two spares 6 M5x12 Screws 6 Washers Includes two spares for each Cord Retention Trays x 2 AA HAZ Cable Ties Qty 20 RJ45 DB9 Serial Port Connection Cable Registration Card Registration Card CD Documentation User Manual Before using please check to ensure the package contains all the items shown above If there are missing parts please contact CyberPower technical support at tech cpsww com or call 1 877 297 6937 when you are US customers For European customers please contact Check CyberPower at support cpsww eu Safety Precautions Read the following before installing or operating t

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi  Conceptronic USB Multi Tip Power Pack 1500mAh  Nicht für Damen!  Electric Dryer S_cheuse _lectrique  Boycott entretien notation - Solidaires Finances publiques  Samsung ML-5510ND Monolaser Drucker Benutzerhandbuch  HP B9100 User's Manual  Inscription : mode d`emploi ANNEXE A LA FICHE D`INSCRIPTION    