Home

Tripp Lite 120V, 1000W PowerVerter APS Inverter/Charger with Pure Sine Wave Output

image

Contents

1. 12 Volt Main and Auxiliary House Battery Connection Isolated Parallel 12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary House Battery UL Listed Fuse amp Fuse Block mounted within 18 inches of the battery Battery Isolator Large Diameter Cabling Maximum 2 0 Gauge to Fit Terminals 4 Installation and Operation 4 1 Installation 4 1 1 Environment The Inverter Charger must be installed in a protected location that is isolated from sources of high temperature and moisture To promote peak performance battery cables should be kept as short as possible However do not install the Inverter Charger in the same compartment as non sealed batteries Accumulated hydrogen and oxygen generated by the batteries could be ignited by an arc resulting from connection of the battery cables or by switching a relay The Inverter Charger requires unrestricted air flow to operate at high power for sustained periods Do not mount the inverter in an enclosed space This will restrict air flow and cause the inverter s protection circuitry will activate reducing maximum available power 4 1 2 System Grounding Proper grounding is essential to assure safe operation of the Inverter Charger Grounding requirements vary in country and application For specific requirements pertaining to your location and application consult local codes and the NEC 4 2 Installation Diagrams and Charts 4 2 1 Terminal B
2. e Compruebe las conexiones de la bater a en busca de signos de tensi n o corrosi n Si encuentra signos de corrosi n desconecte los cables limpielos con una soluci n suave de bicarbonato y agua NO PERMITA QUE LA SOLUCI N ENTRE EN LA BATER A Cuando haya terminado aclare la parte superior de la bater a con agua limpia e Para reducir la corrosi n de los bornes de la bater a apl queles una capa fina de vaselina o grasa anticorrosi n No aplique ninguna sustancia entre los bornes y las agarraderas de los cables la conexi n debe ser de metal a metal Aplique el material de protecci n una vez que los pernos se hayan apretado 3 3 Instalaci n de la bater a de seguridad importantes que se encuentran al comienzo de este manual y las precauciones del proveedor de la bater a antes de instalar el convertidor y las bater as iPrecauci n Las bater as pueden generar corrientes sumamente altas Revise las instrucciones 3 3 1 Ubicaci n de la bater a Las bater as se deben instalar en una localizaci n accesible en la que resulte facil llegar a las tapas y bornes de la bater a Se recomienda que haya por lo menos 60 cm de distancia por encima Deben estar situadas lo m s cerca posible del convertidor No coloque el convertidor en el mismo compartimiento que las bater as no herm ticas las bater as herm ticas si son aceptables Los gases producidos por estas bater as durante las cargas son muy corrosivos y reducir n la
3. Interruptor 7 ON ON OFF __ oe ee OFF OFF 324 24A 20A Predeterminado 48A 36A 30A Predeterminado APS1012SW APS2012SW Nota 1 el r gimen de carga depende del tama o del m dulo de bater as Consulte las especificaciones del fabricante de la bater a para la tasa de carga m xima permisible normalmente 0 3 veces la especificaci n AH Ampers Hours A N iPrecauci n Un r gimen de carga excesivamente alto puede recalentar la bater a Si se utiliza una bater a de poca capacidad fije el r gimen de carga de la bater a en el nivel m nimo 1 3 Caracter sticas 1 3 1 Puerto de temperatura de la bater a Este puerto permite la conexi n de un cable sensor de temperatura de la bater a se vende por separado La funci n del sensor prolonga la vida de la bater a al ajustar el nivel de voltaje variable de la carga en funci n de la temperatura de la bater a Conecte el cable sensor al puerto RJ11 que tiene la leyenda Battery Temperature temperatura de la bater a Con la cinta aislante el ctrica O para conductos de la que usted disponga fije el sensor en el lateral de la bater a por debajo del nivel del electrolito Aseg rese de que no haya ning n objeto ni siquiera la cinta situado entre el sensor y el lateral de la bater a Con el fin de evitar falsas lecturas debidas a la temperatura ambiente coloque el sensor entre las bater as si fuera posible o alejado de fuentes extremas de calor o
4. depending on the Switch 6 7 and 8 ON OFF settings NOTE For Tripp Lite Inverter Chargers providing 1000 watts or less of continuous AC power a full size battery will normally allow sufficient power for many applications before recharging is necessary For mobile applications if a single battery is continuously fed by an alternator at high idle or faster then recharging from utility or generator power may not be necessary For Tripp Lite Inverter Chargers over 1000 watts used in mobile applications Tripp Lite recommends you use at least two batteries if possible fed by a heavy duty alternator anytime the vehicle is running Tripp Lite Inverter Chargers will provide adequate power for ordinary usage within limited times without the assistance of utility or Senerator power However when operating extremely heavy electrical loads at their peak in the absence of utility power you may wish to assist your batteries by running an auxiliary generator or vehicle engine and doing so at faster than normal idling 7 3 Battery 3 2 Monthly Maintenance e Check the level of the electrolyte of each Wet Cell battery cell monthly after the batteries have been charged It should be about one half inch above the top of the plates but not completely full Note This is not necessary on maintenance free batteries e Check the battery connections for tightness and corrosion If any corrosion is found disconnect the cables and clean them with
5. Note The charging rate depends on the battery bank size Consult the a manufacturer s specs for the maximum allowed charge rate usually 0 3 times the AH rating mn Caution An excessively high charging rate can overheat the battery If a small capacity battery is used set the battery charge rate to the minimum setting 1 3 Features 1 3 1 Battery Temperature Port This port allows connection of a Battery Temperature Sensing Cable sold separately The sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature Connect the sensor cable to the RJ11 port labeled Battery Temperature With user supplied electrical or duct tape secure the sensor to the side of the battery below the electrolyte level Make sure that nothing not even tape comes between the sensor and the side of the battery To guard against false readings due to ambient temperature place the sensor between batteries if possible or away from the sources of extreme heat or cold If the sensor cable is not used the Inverter Charger will charge according to its default 25 C values 1 3 2 Communication Port for APSRMSW Remote Control This port allows connection with the APSRMSW Remote Control Sold separately The remote conrol allows the Inverter Charger to be mounted in a compartment or cabinet out of sight while operated conveniently from a remote location See instructions packed with the remote control modu
6. almacenaje de todos los convertidores cargadores Tripp Lite Advertencias de ubicaci n e Instale su convertidor cargador en una ubicaci n o compartimento que minimice la exposici n al calor polvo luz solar directa y humedad Si la unidad se llena de agua se puede producir un cortocircuito que podr a causar lesiones f sicas debido a una descarga el ctrica e Deje un espacio m nimo de 2 pulgadas 5 cm en la parte delantera y trasera del convertidor cargador para una adecuada ventilaci n Con el fin de evitar el sobrecalentamiento del convertidor cualquier compartimento en el que est alojado el dispositivo debe estar adecuadamente ventilado con una entrada de aire del exterior Cuanto m s pesada sea la carga del equipo conectado m s calor generar la unidad e No instale el convertidor cargador directamente cerca de un medio de almacenaje magn tico ya que esto puede corromper los datos e No realice la instalaci n cerca de materiales inflamables combustibles ni productos qu micos e No monte esta unidad con el panel frontal o con el panel trasero hacia abajo Bajo ning n ngulo o inclinaci n Si lo monta de esta manera inhibir seriamente el sistema de enfriamiento interno de la unidad lo que finalmente causar da os al producto que no est n cubiertos por la garant a Advertencias de conexi n de la bater a e Los sistemas de varias bater as pueden estar compuestos de bater as de id ntico voltaje antigueda
7. fr o Si no se utiliza el cable sensor el convertidor cargador realizar la carga de acuerdo con sus valores por defecto de 25 C 1 3 2 Puerto de comunicaci n para el control remoto APSRMSW Este puerto permite la conexi n con el control remoto APSRMSW se vende por separado El control remoto permite que el convertidor cargador se monte en un compartimento o una cabina a distancia y que se pueda controlar c modamente desde una ubicaci n a distancia Consulte las instrucciones que se adjuntan con el m dulo de control remoto para obtener m s informaci n 2 Cargador de bater a 2 1 Modo de funcionamiento El cargador de bater a interno y el rel de transferencia autom tica permiten que la unidad opere como cargador de bater a o como convertidor Una fuente externa de alimentaci n CA p ej potencia de tierra o generador se debe conectar a la entrada CA del convertidor para permitir que funcione como cargador de bater a Cuando la unidad funciona en modo cargador las cargas CA se suministran desde una fuente externa de suministro CA 2 2 Velocidad de cambio de transferencia El tiempo de transferencia es menos de 16 milisegundos 3 1 Selecci n del tipo de bater a Seleccione las bater as 12V de ciclo profundo para obtener el nivel ptimo de rendimiento de su convertidor cargador No utilice una bater a corriente de coche bater as de arranque ni amperios de arranque en fr o AAF Si las bater as que conecta al con
8. momento Compruebe limpie y apriete regularmente todas las conexiones de los cables en la medida que sea necesario tanto en la unidad como en la bater a e Una bater a de tama o peque o que se cargue a un r gimen de carga superior puede provocar una parada por sobrecarga Para evitar esto reduzca el r gimen de carga o descargue la bater a por completo antes de recargarla e Si el convertidor no se pone en marcha adecuadamente desconecte el sistema de la bater a durante 30 segundos y repita el procedimiento de puesta en marcha Si el sistema sigue sin funcionar adecuadamente visite www tripplite com support Su producto Tripp Lite est cubierto por la garant a descrita en este manual Tripp Lite tambi n pone a su disposici n una variedad de Garant as extendidas y Programas de servicio t cnico en el sitio Si desea m s informaci n sobre el servicio t cnico visite www tripplite com support Antes de devolver su producto para servicio t cnico siga estos pasos 1 Revise la instalaci n y los procedimientos de operaci n que se encuentran en este manual para asegurarse de que el problema de servicio no se debe a una mala lectura de las instrucciones 2 Si el problema persiste no se comunique ni devuelva el producto al mayorista En cambio visite www tripplite com support 3 Si el problema exige servicio t cnico visite www tripplite com support y haga clic en el enlace Devoluciones de productos Desde aqu puede solicit
9. serie El n mero de serie no debe ser confundido con el nombre de identificaci n ni con el n mero de modelo del producto Tripp Lite tiene una pol tica de mejoramiento continuo Las especificaciones est n sujetas a cambio sin previo aviso TRIPP LITE THE POWER PEOPLE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 24 201110125 933053 ES
10. without notice TRIPP LITE THE POWER PEOPLE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 12 201110125 933053 EN Manual del propietario Convertidores cargadores de ondas sinusoidales CC a CA Modelos APS1012SW APS2012SW 12V CC a 120V CA Indice Instrucciones de seguridad importantes 1 Visi n de conjunto y caracter sticas 1 1 Visi n de conjunto 1 2 Indicadores controles y configuraciones 1 3 Caracter sticas opcionales 2 Cargador de bater a 2 1 Modo de funcionamiento 2 2 Velocidad de transferencia de conexi n 3 Instalaci n y mantenimiento de la bater a 3 1 Seleccionar el tipo de bater a 3 2 Mantenimiento mensual 3 3 Instalaci n de la bater a 3 4 Conexi n de la bater a 14 4 Convertidor cargador Instalaci n y funcionamiento 4 1 Instalaci n 4 2 Diagramas y gr ficos de instalaci n 4 3 Instalaci n y puesta en marcha 5 Especificaciones t cnicas 6 Soluci n de problemas 7 Asistencia t cnica y registro de la garant a English TRIPP LITE THE POWER PEOPLE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2011 Tripp Lite Todos los derechos reservados 22 22 23 23 24 24 Instrucciones de seguridad importantes iGUARDE ESTAS INSTRUCCIONES Este manual contiene instrucciones y advertencias importantes que se deben seguir durante la instalaci n el funcionamiento y el
11. D flashes during the charging process and remains illuminated once the battery is full charged 1 2 5 Inverter Condition LED 3 When the inverter temperature exceeds the default setting this LED will flash and the inverter will shut down automatically After the temperature returns to normal depress the Power ON OFF button to restart When the unit is overloaded in DC mode LEDs 1 3 and the audible alarm indicate inverter status as follows Load Capacity DC Mode LED1 LED 3 Alarm INVERTER STATUS 110 129 1 beep O 5sec Shutdown after 60 seconds 130 149 On Constant Shutdown after 10 seconds gt 150 On Constant Shutdown after 1 second 1 2 6 Battery Limits LED 4 Battery High In AC mode LED 4 will flash Battery Low LED 4 will illuminate and the alarm will beep once every five seconds for three minutes If the battery voltage drops below the cutoff voltage LBCO then the inverter will shut down all LEDs except LED4 and will turn off 4 1 Overview and Features 1 2 7 Battery Voltage LED 5 8 LED 5 8 indicate the battery capacity as detailed in the following table Battery Voltage 25 ao Yoo so po a Yoo y o 1 2 8 Voltage Setting Switch 1 3 DC to AC Transfer Delay Switch 1 30 sec Default 5 sec Low Battery Alarm Switch 2 11 24 10 9V Default AC Transfer Voltage Switch 3 85V Default Note 1 Switch 1 is located farthest from the battery temperature port See diagram on
12. On Off Off On 10 2 11 5V 11 5 12 5V 12 5 13 0V gt 13 0V 5 sec for DC Mode 3 min Low Battery 1 beep Battery High _ _ _ 1 beep ae Flashing 10 2 11 5V 11 5 12 5V 12 5 13 0V gt 13 0V 6 0 5500 Overload 1 bee 110 129 On Off On Off 10 2 11 5V 11 5 12 5V 12 5 13 0V gt 13 0V or ah DC Mode Overload On 130 149 On Off On Off 10 2 11 5V 11 5 12 5V 12 5 13 0V gt 13 0V constant DC Mode Overload On gt 150 On Off On Off 10 2 11 5V 11 5 12 5V 12 5 13 0V gt 13 0V constant DC Mode AC Bypass off off off off 10 8 11 5V 11 5 12 5V 12 5 13 5V gt 13 5V off Power Off 1 2 2 Power ON OFF Button The Power ON OFF button is located in the left of the panel Press to power the Inverter Charger ON or OFF When the button is pressed the alarm will beep Note When connected to batteries the Inverter Charger will start up even if not connected to AC power Defaults to 6OHZ Note Unit is in BYPASS mode as soon as power is applied to the input Power On Press the Power ON OFF button for 3 seconds until the alarm beeps and the INVERTER MODE light illuminates Power Off Press the Power ON OFF button for 3 seconds The alarm will beep when the shutdown process is completed 1 2 3 DC Mode Inverter LED 1 This LED illuminates to indicate that the system is working in inverter mode Supplying power from battery 1 2 4 AC Mode Charger LED 2 The LE
13. Owner s Manual Sine Wave DC to AC Inverter Chargers Models APS1012SW APS2012SW 12VDC to 120VAC Table of Contents Important Safety Instructions 2 4 Inverter Charger 1 Overview amp Features 3 Installation and Operation 10 1 1 Overview 2 4 1 Installation 10 1 2 Indicators Controls and Settings 3 4 2 Installation Diagrams and Charts 10 1 3 Optional Features 6 4 3 Installation and Start Up 11 2 Battery Charger 6 5 Technical Specifications 11 2 1 Mode of Operation 6 6 Troubleshooting 12 2 2 Transfer Switching Speed 6 7 Service and 3 Battery Installation Walralty NegIStratON 12 and Maintenance 6 Espa ol 13 3 1 Select Battery Type 6 3 2 Monthly Maintenance 8 3 3 Battery Installation 8 3 4 Battery Connection 8 TRIPP LITE THE POWER PEOPLE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright O 2011 Tripp Lite All rights reserved Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite Inverter Chargers Location Warnings Install your Inverter Charger in a location or compartment that minimizes exposure to heat dust direct sunlight and moisture Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock Leave a minimum of 2 clearance at front and back of the I
14. a energ a de corriente alterna suministrada por la red o por un generador M270 Amperios hora Compense por ineficiencia multiplicando este numero por 1 2 Esto le dara un estimado grueso de cuantos amperios hora de energia de bater a de una o varias bater as debe conectar a su inversor cargador Nota La capacidad de amperios hora de una bater a usualmente se da considerando una descarga de 20 horas Las capacidades reales de amperios hora son menores cuando las bater as est n descargando a mayor velocidad Por ejemplo bater as descargadas en 55 minutos proporcionan s lo 50 de sus amperios hora nominales mientras que las bater as descargadas en 9 minutos proporcionan apenas 30 de sus amperios hora nominales e PASO 4 Estime la recarga de bater a requerida considerando su aplicaci n Debe permitir que sus bater as se recarguen el tiempo suficiente para reemplazar la carga perdida durante la operaci n del inversor por que de 270 amperios horas 55 amperios otro modo sus bater as eventualmente se descargar n Para estimar la Capacidad de inversor cargador cantidad m nima de tiempo que debe recargar sus bater as considerando 5 Horas de Recarga su aplicaci n divida sus amperios hora de bater a requeridos del paso 3 arriba entre los amperios de carga nominales de su inversor cargador dependiendo de la posici n ON OFF de los interruptores 6 7 y 8 Nota Para los inversores cargadores de Tripp Lite que propor
15. a mild solution of baking soda and water DO NOT ALLOW THE SOLUTION TO ENTER THE BATTERY When finished rinse the top of the battery with clean water e To reduce corrosion on the battery terminals coat them with a thin layer of petroleum jelly or anti corrosion grease Do not apply any material between the terminal and the cable lugs the connection should be metal to metal Apply the protective material after the bolts have been tightened 3 3 Battery Installation Caution Batteries can produce extremely high currents Review both the important safety instructions at the beginning of this manual and the battery supplier s precautions before installing the inverter and batteries 3 3 1 Battery Location Batteries should be installed in an accessible location with good access to the battery caps and terminals At least two feet 24 in of overhead clearance is recommended They must be located as close as possible to the inverter Do not locate the inverter in the same compartment with non sealed batteries sealed batteries are acceptable The gasses produced by these batteries during charging are very corrosive and will shorten the life of the inverter 3 3 2 Battery Enclosure Batteries should be installed in a ventilated locked enclosure or room The enclosure should be well ventilated to prevent accumulation of hydrogen gasses that are released in the battery charging process The enclosure should be made of acid resistant mater
16. aberturas de paso de cables en los paneles de la unidad Advertencias de funcionamiento e Su convertidor no requiere mantenimiento rutinario e En el interior del convertidor cargador puede haber voltajes potencialmente peligrosos mientras el suministro de la bater a est conectado Por lo tanto durante cualquier trabajo de mantenimiento la bater a debe estar desconectada e No conecte ni desconecte las bater as mientras el convertidor cargador est funcionando con suministro de la bater a Se puede producir un arco el ctrico peligroso 14 1 Vision de conjunto y caracteristicas 1 1 Vision de conjunto El convertidor cargador de ondas sinusoidales de Tripp Lite es una unidad de carga de gran potencia que genera una onda sinusoidal pura a partir de un modulo de baterias de 12V Puede suministrar energia a gran variedad de equipos conectados desde radiadores aparatos de aire acondicionado refrigeradores y aspiradoras a ordenadores y dispositivos perif ricos Est dise ado para trabajar en condiciones de carga pesada de manera que no es necesaria una disminuci n de potencia El cargador inteligente es compatible con varios tipos y tama os de bater as El m dulo del conmutador desv a autom ticamente la trayectoria de transferencia de energ a entre el convertidor y una entrada de CA Cuando la fuente de CA es menor que el nivel transferido la trayectoria pasa al convertidor De otro modo la carga se alimenta por med
17. and tighten all cable connections as necessary both at the unit and at the battery e A small size battery being charged at a higher charging rate could cause an overvoltage shutdown To prevent this reduce the charge rate or discharge the battery before recharging e f the Inverter does not start up properly disconnect the system from the battery for 30 seconds and then repeat the startup procedure If the system still does not start up properly visit www tripplite com support Your Tripp Lite product is covered by the warranty described in this manual A variety of Extended Warranty and On Site Service Programs are also available from Tripp Lite For more information on service visit www tripplite com support Before returning your product for service follow these steps 1 Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the instructions NO If the problem continues do not contact or return the product to the dealer Instead visit www tripplite com support 3 If the problem requires service visit www tripplite com support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service This simple on line form will ask for your unit s model and serial numbers along with other general purchaser information The RMA number along with shipping instructions will
18. ar un n mero de Autorizaci n de Material Devuelto RMA que se necesita para el servicio t cnico En este sencillo formulario en l nea se le solicitar n los n meros de serie y modelo de la unidad junto con otra informaci n general del comprador El n mero RMA y las instrucciones para el env o se le enviar n por correo electr nico La presente garant a no cubre ning n da o directo indirecto especial o consecuencial del producto que ocurra durante el env o a Tripp Lite o a un centro de servicio t cnico de Tripp Lite autorizado Los productos enviados a Tripp Lite o a un centro de servicio t cnico de Tripp Lite autorizado deben tener prepagos los cargos de transporte Escriba el n mero RMA en el exterior del embalaje Si el producto se encuentra dentro del per odo de garant a adjunte una copia de su recibo de venta Env e el producto para servicio t cnico mediante un transportador asegurado a la direcci n que se le proporcion cuando solicit el n mero RMA Cumplimiento de las normas de los n meros de identificaci n Para fines de identificaci n y certificaci n del cumplimiento de las normas su producto Tripp Lite tiene asignado un n mero de serie nico Puede encontrar el n mero de serie en la etiqueta de la placa de identificaci n del producto junto con los s mbolos de aprobaci n e informaci n requeridos Al solicitar informaci n sobre el cumplimiento de las normas para este producto siempre mencione el n mero de
19. be emailed to you Any damages direct indirect special or consequential to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty Products shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the product is within its warranty period enclose a copy of your sales receipt Return the product for service using an insured carrier to the address given to you when you request the RMA WARRANTY REGISTRATION Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product Tripp Lite follows a policy of continuous improvement Product specifications are subject to change
20. cionan 1000 vatios o menos de energ a de corriente alterna en forma permanente una bater a de tama o completo normalmente permitir suficiente energ a para muchas aplicaciones ante de que la recarga sea necesaria Para aplicaciones m viles si una sola bater a es alimentada continuamente por un alternador en alto vac o o m s r pido la recarga con energ a de la red o de un generador puede no ser necesaria Para inversores cargadores de Tripp Lite mayores que 1000 vatios usados en aplicaciones m viles Tripp Lite recomienda usar al menos dos bater as si es posible alimentadas por un alternador de servicio pesado siempre que el veh culo est funcionando Los inversores cargadores Tripp Lite proporcionar n energ a adecuada para uso ordinario por tiempos limitados sin la ayuda de energ a de la red o de un generador Sin embargo al operar con cargas el ctricas muy pesadas en sus valores m ximos y en ausencia de energ a de la red puede desear ayudar a sus bater as haciendo funcionar un generador auxiliar o el motor de un veh culo y hacerlo m s r pido que en operaci n normal de vac o 19 3 2 Mantenimiento mensual e Compruebe mensualmente el nivel del electrolito de cada bater a de celda h meda despu s que las bater as han sido cargadas Debe estar 13 mm 1 2 media pulgada aproximadamente sobre el borde superior de las placas pero no completamente llena Nota Esto no es necesario para bater as libres de mantenimiento
21. d capacidad amperiohora y tipo e Como se puede acumular hidr geno explosivo cerca de las bater as si no estan bien ventiladas no debe instalar estas en un compartimento con aire viciado Lo ideal es que cualquier compartimento disponga de una entrada de aire exterior para la ventilaci n e Se pueden producir chispas durante la conexi n de la bater a Al conectar las bater as h galo siempre en los polos adecuados e No permita que haya objetos en contacto con los terminales de entrada CC No acople ni conecte estos terminales juntos Se pueden producir da os a la propiedad o lesiones f sicas graves Advertencias de conexi n a tierra e Una operaci n segura requiere conectar la terminal de conexi n a tierra del Inversor Cargador directamente al bastidor del veh culo o una tierra f sica Advertencias de conexi n del equipo e El uso de este equipo en aplicaciones de soporte de vida en donde la falla de este equipo pueda razonablemente hacer suponer que causar fallas en el equipo de soporte de vida o afecte significativamente su seguridad o efectividad no est recomendado No use este equipo en la presencia de una mezcla anest sica inflamable con aire oxigeno u xido nitroso Podra experimentar resultados de rendimiento desigual si conecta un supresor de sobrecarga un acondicionador de linea o un sistema UPS a la toma de salida del convertidor cargador El usuario debe suministrar la protecci n adecuada para las
22. de polaridad en todas las conexiones CC ADVERTENCIA Si no conecta a tierra su convertidor cargador en la carrocer a de un veh culo o a 3 4 2 No Vehicular y Vehicular El voltaje de entrada CC de su convertidor cargador debe coincidir con el voltaje de su bater a o bater as 12 voltios en la mayor a de aplicaciones vehiculares Es posible conectar su convertidor cargador a la bater a principal dentro del sistema el ctrico de su veh culo En la mayor a de veh culos el convertidor cargador estar conectado a una o m s bater as dedicadas auxiliares alojamiento que est n aisladas del sistema de conducci n para evitar el posible agotamiento de la bater a principal TRIPP LITE 12 Volt Inverter Charger 12 Volt Main Battery Connection TRIPP LITE 12 Volt Inverter Charger 12 Volt Main and Auxiliary House Battery Connection Isolated Parallel Alternador de 12 voltios Tierra de la bater a del veh culo Bater a principal de 12 voltios Bater a auxiliar de 12 voltios alojamiento Fusible y bloque de fusibles homologado por UL montado a un m ximo de 45 cm de la bater a Aislador de Bateria Cableado de Di metro Grande Calibre M ximo 2 0 para encajar en Terminales 21 4 Instalacion y funcionamiento 4 1 Instalacion 4 1 1 Entorno El convertidor cargador debe estar instalado en una ubicaci n protegida que est aislada de fuentes de temperatura y humedad el
23. e Su convertidor cargador puede suministrar un voltaje m ximo de hasta un 200 m s que su r gimen de salida de vatiaje continuo durante breves per odos de tiempo Se debe utilizar cableado de mayor calibre cuando haya equipos de carga pesada funcionando constantemente en estas condiciones Ajuste el convertidor cargador y los bornes de la bater a con un par de torsi n aproximado de 3 5 newton metros para crear una conexi n eficiente y para evitar el calentamiento excesivo en esta conexi n Si los bornes no est n lo suficientemente apretados la garant a podr a quedar anulada Longitud m xima recomendada del cable CC Distancia m xima desde la bater a al convertidor cargador Calibre del cable AWG Salida 2 0 029 1000W 2000W EOE o eales 20 e Conectar el fusible el art culo 551 del NEC C digo El ctrico Nacional exige que conecte todos los terminales CC positivos de su convertidor cargador directamente a un fusible o fusibles homologados por UL y un bloque o bloques de fusibles que sean iguales o excedan el r gimen m nimo de fusible CC que se muestra en la placa del convertidor cargador Consulte los diagramas de abajo para conocer la colocaci n adecuada del fusible una toma de tierra puede producirse una descarga el ctrica letal No intente manejar nunca su convertidor cargador conect ndolo directamente a la salida de un alternador en lugar de a una bater a o m dulo de bater as e Siga las normas
24. e carga Modo CC LED1 LED3 Alarma INVERTER STATUS 1410 Oo Oon o 1 pitido O 5 seg Apagado tras 60 segundos 130 O On Constante Apagado tras 10 segundos gt 150 oOo ono ono On Constante Apagado tras 1 segundo 1 2 6 L mites de bater a LED 4 Bater a alta En el modo CA se destellar el LED 4 Bater a baja El LED 4 se iluminar y la alarma emitir un bip cada cinco segundos durante tres minutos Si el voltaje de la bater a desciende por debajo del voltaje de corte LBCO entonces el inversor apagar todos los LEDs excepto el LED4 y se apagar 16 1 Vision de conjunto y caracteristicas 1 2 7 Voltaje de la bateria LED 5 8 Los LED 5 8 indican la capacidad de la bateria como se detalla en la siguiente tabla EA A S S S S EX 1 2 8 Configuraci n del voltaje Interruptores 1 3 Retardo de transferencia CC a CA Interruptor 1 30 seg Predeterminado Alarma de bater a baja Interruptor 2 11 2V 10 9V Predeterminado Voltaje de transferencia CA Interruptor 3 85V Predeterminado Nota 1 El Interuptor 1 se encuentra m s alejado del puerto de temperatura de la bater a Vea el diagrama en la pagina 3 2 Todos los interruptores se deben configurar antes de encender el sistema 3 El interruptor 2 establece el nivel de alarma de bajo voltaje de la bater a a un voltaje m s alto la alarma suena m s frecuentemente 4 Interruptor 3 Punto de Voltaje Bajo CA to CD Si el
25. ed STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or generator supplied AC power Compensate for inefficiency by 45 DC Amps x 5 Hrs Runtime multiplying this number by 1 2 This will give you a rough estimate of x 1 2 Inefficiency Rating how many amp hours of battery power from one or several batteries you should connect to your Inverter Charger NOTE Battery amp hour ratings are usually given for a 20 hour discharge rate Actual amp hour capacities are less when batteries are discharged at faster rates For example batteries discharged in 55 minutes provide only 50 of their listed amp hour ratings while batteries discharged in 9 minutes provide as little as 30 of their amp hour ratings STEP 4 Estimate Battery Recharge Required Given Your Application You must allow your batteries to recharge long enough to replace the charge lost during inverter operation or else you will eventually run 270 Amp Hours 55 Amps down your batteries To estimate the minimum amount of time you Inverter Charger Rating EETA need to recharge your batteries given your application divide your 8 8 5 required battery amp hours from step 3 above by your Inverter Charger s rated charging amps
26. el voltaje nominal de la bater a sea de 12V 4 3 2 Conecte la unidad a la carga CA Despu s conecte a la fuente CA Confirme que todo el cableado y las conexiones sean correctos y la terminal est apretada 4 3 3 Pulse el bot n ON OFF El sistema empezar a funcionar en pocos segundos Si la fuente de energ a CA fallase la unidad funcionar en el modo convertidor De otro modo el sistema pasar al modo CA y suministrar potencia mientras carga la bater a 5 Especificaciones t cnicas Modelo Especificaci n Potencia Continua Eficiencia M xima del Inversor Forma de onda de salida Potencia CC al r gimen de potencia Fusible Recomendado para la bater a Voltaje de entrada nominal R gimen de entrada de voltaje CC Protecci n de bater a baja carga pesada ligera Regulaci n del voltaje de salida en modo CC Factor de potencia autorizado Regulacion de frecuencia Voltaje de salida estandar Sensor de carga ahorro de potencia Tiempo de transferencia Refrigeraci n por aire forzado Rel de transferencia autom tica Corriente de carga ajustable Carga resistiva Carga inductiva Carga motor Carga del rectificador Montaje en la pared APS1012SW APS2012SW 250 amperios 400 amperios 10 9 11 2 V CC 10 23 6 Solucion de problemas e Su convertidor cargador no requiere mantenimiento y no contiene piezas que el usuario deba mantener o sustituir pero se debe mantener seco en todo
27. endido o apagado est situado a la izquierda del panel Pulse el bot n para que la alimentaci n del convertidor cargador se encienda o apague Cuando pulse el bot n la alarma pitar Nota cuando est conectado a las bater as el convertidor cargador se encender incluso si no est conectado a una fuente de alimentaci n CA Predeterminado a 60Hz Nota La unidad est en modo de Rodeo BYPASS en cuanto se aplica energ a en la alimentaci n Alimentaci n encendida Pulse el bot n POWER ON OFF durante 3 segundos hasta que la alarma pite y se ilumine la luz del MODO CONVERTIDOR Alimentaci n apagada Pulse el bot n POWER ON OFF durante 3 segundos La alarma pitar cuando el proceso de apagado se complete 1 2 3 Modo convertidor CC LED 1 Este LED se ilumina para indicar que el sistema est funcionando en modo convertidor suministrando potencia desde la bater a 1 2 4 Modo cargador CA LED 2 El LED parpadea durante el proceso de carga y permanece iluminado una vez que la bater a est completamente cargada 1 2 5 Estado de convertidor LED 3 Cuando la temperatura del convertidor exceda el valor fijado por defecto este LED se destellar y el convertidor se apagar autom ticamente Cuando la temperatura vuelva a l mites normales pulse el bot n POWER ON OFF para reiniciar Cuando la unidad est sobercargada en modo CD los LED 1 y 3 as como la alarma sonora indicar n el estado del convertidor como sigue A d
28. erio hora total de las bater as conectadas y el respaldo del alternador de su veh culo si el motor est encendido El jemplo e PASO 1 Determine la potencia total requerida Herramientas A ada la potencia nominal de todos los equipos que va a conectar a INERTES A a a su inversor cargador La potencia nominal de un equipo normalmente ES NAT Ae est indicada en su manual o en su placa Si su equipo tiene un A valor en amperios multiplique ese numero por el voltaje en corriente z alterna de la red para calcular los vatios Ejemplo a taladro de 1 4 requiere 2 2 amperios 212 amperios x 120 voltios 300 vatios Nota Su inversor cargador operar a mayores eficiencias al 75 80 Aparatos aproximadamente de su valor de placa TV Color Computadora port til e PASO 2 Determine la corriente en amperios de corriente continua de bater a requerida Divida los vatios totales requeridos del paso 1 arriba entre el voltaje 540 vatios 12V CE ue de la bater a 12 24 36 o 48 para determinar los amperios de corriente continua requeridos PASO 3 Estime los amperios hora de bater a requeridos para operaci n no soportada por el alternador Multiplique los amperios de corriente continua requeridos del paso 2 arriba entre el n mero de horas que estima usted operar su equipo exclusivamente 45 amps CC x 5 horas funcionamiento con energia de bateria antes de que tenga que recargar sus baterias con x 12 factor de ineficienci
29. evadas Con el fin de fomentar el m ximo rendimiento los cables de la bater a deben ser lo m s cortos posible No obstante no se debe instalar el convertidor cargador en el mismo compartimento que las bater as no selladas El hidr geno y el ox geno acumulados y generados por las bater as podr an prender al generarse un arco el ctrico resultante de la conexi n de los cables de la bater a o al conectar un rel El convertidor cargador requiere un flujo de aire continuo para que funcione a potencia alta durante per odos mantenidos No monte el convertidor en un espacio cerrado Esto limitar el flujo de aire y provocar que el circuito de protecci n del convertidor se active reduciendo la potencia m xima disponible 4 1 2 Puesta a tierra del sistema Una puesta a tierra adecuada es primordial para garantizar el funcionamiento seguro del convertidor cargador Los requisitos de puesta a tierra var an en los diferentes pa ses y en funci n de la aplicaci n Si desea conocer los requisitos correspondientes a su localizaci n y aplicaci n consulte los c digos locales y el NEC 4 2 Diagramas y gr ficos de instalaci n 4 2 1 Bloque de terminal fase CA 4 2 2 Terminal Fase CC O BATTERY POSITIVE wi Al 2 lt o W z gt Dz uu E lt m i O 22 4 Instalacion y funcionamiento 4 3 Instalacion y puesta en marcha 4 3 1 Conecte la unidad a las bater as conforme a la secci n 3 Aseg rese que
30. ial or coated with an acid resistant finish to resist corrosion from spilled electrolyte and released fumes If the batteries are located outdoors the enclosure should be rainproof and have mesh screens to prevent insects and rodents from entering Before placing the batteries in the enclosure cover the bottom with a layer of baking soda to neutralize any acid spills 3 4 Battery Connection 3 4 1 Connect your Inverter Charger to your batteries using the following procedures e Connect DC Wiring Though your Inverter Charger is a high efficiency converter of electricity its rated output capacity is limited by the length and gauge of the cabling running from the battery to the unit Use the shortest length and largest diameter cabling to provide maximum performance see table below Shorter and heavier gauge cabling reduces DC voltage drop and allows for maximum transfer of current Your Inverter Charger is capable of delivering peak wattage at up to 200 of its rated continuous wattage output for brief periods of time Heavier gauge cabling should be used when continuously operating heavy draw equipment under these conditions Tighten your Inverter Charger and battery terminals to approximately 3 5 Newton meters of torque to create an efficient connection and to prevent excessive heating at this connection Insufficient tightening of the terminals could void your warranty Maximum Recommended DC Cable Length Maximum Distance From Battery to Inverte
31. in series are also acceptable In many cases the vehicle battery may be the only one installed Auxiliary batteries must be identical to the vehicle batteries if they are connected to each other 6 3 Battery 3 1 1 Match Battery Amp Hour Capacity to Your Application Select a battery or system of batteries that will provide your Inverter Charger with proper DC voltage and an adequate amp hour capacity to power your application Even though Tripp Lite Inverter Chargers are highly efficient at DC to AC inversion their rated output capacities are limited by the total amp hour capacity of connected batteries and the support of your vehicle s alternator if the engine is kept running E xample e STEP 1 Determine Total Wattage Required Tools Add the wattage ratings of all equipment you will connect to your A Dun Orbital Sander Cordless Tool Charger Inverter Charger Wattage ratings are usually listed in equipment manuals or on nameplates If your equipment is rated in amps multiply that number times AC utility voltage to determine watts Example a Y4 in drill requires 2 2 amps 27 amps x 120 volts 300 watts Note Your Inverter Charger will operate at higher efficiencies at about 75 80 of Appliances nameplate rating Color TV Laptop Computer STEP 2 Determine DC Battery Amps Required Divide the total wattage required from step 1 above by the battery 540 watts 12V ENTE voltage 12 to determine the DC amps requir
32. io de la entrada de CA 1 2 Indicadores controles y configuraciones 1 2 1 Controles e indicadores LED Abajo se muestra el panel de control y las luces indicadoras del panel frontal del convertidor cargador DCMODE ACNODE INVERTER BATFERY INVERTER CHARGER CONDITION LIMITS O OFF MAX fovT HIGH ee 0090 RESET O ON FLOAT Qut0ovL LOW o gt a lt FEATURES SETTINGS 1 DC AC TRAN DELAY 2 LOW BATT ALARM 11 2 10 9 3 LOW ACV TRANSFER TAA UUUUUUUL 4 SEARCH LOAD MODE CHARGER SETTINGS 5 FLOAT VOLTAGE 6 7 8 AMPERES LED 1 Convertidor en modo CC LED 2 Cargador en modo CA LED 3 Estado del convertidor 15 Bot n POWER ON OFF de E LED 4 L mites de bater a encendido y apagado Fal LED 5 25 de voltaje de bater a BATTERY VOLTAGE 25 54 79 100 BATTERY COMMUNICATION i TEMPERATURE LED 8 100 de voltaje de bater a Puerto de temperatura de la bateria Ed LED 6 50 de voltaje de bater a RJ11 EJ LED 7 75 de voltaje de bater a E Puerto de comunicaci n RJ45 1 Vision de conjunto y caracteristicas LED indicador de alarmas Cd ag e o or AA erm for oe form III perc or AECE Modo CD 11 5V 12 5V 13 0V conn Moos OB For or fo or es ats oe oso Sere poc suo or or on or e 55 By sr e Apagado Encendido Encendido Destellando 1 2 2 Boton POWER ON OFF de encendido apagado El bot n POWER ON OFF de enc
33. le for more information 2 Battery Charger 2 1 Mode of Operation The internal battery charger and automatic transfer relay allow the unit to operate as either a battery charger or an inverter An external source of AC power e g shore power or generator must be supplied to the inverter s AC input in order to allow it to operate as a battery charger When the unit is operating as a charger AC loads are powered by the external AC power source 2 2 Transfer Switching Speed Transfer time is less than 16 milliseconds 3 Battery 3 1 Select Battery Type Select 12V Deep Cycle batteries to receive optimum performance from your Inverter Charger Do not use ordinary car or starting batteries or batteries rated in Cold Cranking Amps CCA If the batteries you connect to the Inverter Charger are not true Deep Cycle batteries their operational lifetimes may be significantly shortened If you are using the same battery bank to power the Inverter Charger as well as DC loads your battery bank will need to be appropriately sized larger loads will require a battery bank with a larger amp hour capacity or the operational lifetimes of the batteries may be significantly shortened Batteries of either Wet Cell vented or Gel Cell Absorbed Glass Mat sealed construction are ideal Set Switch 5 to OFF for Wet Cell batteries and to ON for Absorbed Glass Mat AGM batteries Two 6 volt golf cart Marine Deep Cycle or 8D Deep Cycle batteries
34. lock AC Side 4 2 2 Terminal DC Side O BATTERY POSITIVE Wu Al gt lt o uu z gt Dz uu lt m 10 4 3 Installation and Start Up 5 Technical Specifications 4 Installation and Operation Connect the unit to the batteries per Section 3 Ensure that the nominal DC battery voltage is 12V Connect the unit to the AC load Then connect to the AC source Confirm all wiring is correct and terminal is tight Press the ON OFF button The system will start working after a few seconds If the AC source power fails the unit will work in Inverter mode Otherwise the system will switch to AC Mode and will power the load while charging the battery er APS1012SW APS2012SW Specification Continuous Power Peak Inverter Efficiency Output Waveform DC Current at Rated Power Recommended Battery Fuse Nominal Input Voltage DC Input Voltage Range Low Battery Protection Heavy Light Load DC Mode Output Voltage Regulation Power Factor Allowed Frequency Regulation Standard Output Voltage Load Sensing Power Saving Transfer Time Forced Air Cooling Automatic Transfer Relay Adjustable Charge current Resistive Load Inductive Load Motor Load Rectifier Load Wall Mounting 250 Amps 400 Amps 11 6 Troubleshooting e Your Inverter Charger requires no maintenance and contains no user serviceable or user replaceable parts but should be kept dry at all times Periodically check clean
35. nverter Charger for proper ventilation To avoid overheating the Inverter any compartment that contains the Inverter Charger must be properly ventilated with adequate outside air flow The heavier the load of connected equipment the more heat will be generated by the unit Do not install the Inverter Charger directly near magnetic storage media as this may result in data corruption Do not install near flammable materials fuel or chemicals Do not mount unit with its front or rear panel facing down at any angle Mounting in this manner will seriously inhibit the unit s internal cooling eventually causing product damage not covered under warranty Battery Connection Warnings e Multiple battery systems must be comprised of batteries of identical voltage age amp hour capacity and type e Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated do not install batteries in a dead air compartment Ideally any compartment would have some ventilation to outside air e Sparks may result during final battery connection Always observe proper polarity as batteries are connected e Do not allow objects to contact the DC input terminals Do not short or bridge these terminals together Serious personal injury or property damage could result Ground Connection Warnings e Safe operation requires connecting the Inverter Charger s Main Ground Terminal directly to the frame of the vehicle or earth g
36. page 3 2 All switches must be set before the system is turned on 3 Switch 2 sets the low battery voltage alarm level at higher voltage the alarm sounds sooner 4 Switch 3 Low level AC to DC voltage point If the AC input voltage decreases to below the setpoint the inverter will automatically switch to DC MODE Please see the table for details Nominal Voltage Low Voltage Transfer Point AC to DC Return Voltage Point DC to AC mn AA Ss 1 2 9 Search Mode Setting Switch 4 Search Mode activates when the unit is operating in inverter mode battery power to prevent unnecessary battery discharge when electrical power is not required If the inverter is supporting loads that must constantly be powered turn off switch 4 to disable Search Mode A Search Mode Function Inverter only turns on if load gt 100W N Inverter is always on in the absence of 1 2 10 Battery Type Floating Voltage Switch 5 Switen5 Floating Voltage ae eatery Type ON Default 13 8V 14 5V Absorbed Glass Mat AGM 13 2V 13 8V Wet Cell Note The unit will charge the battery to Acceptance voltage continue for up to 12 hours then drop to Floating voltage 1 Overview and Features 1 2 11 Battery Charging Rate Setting Switch 6 7 amp 8 These switches control the maximum charging rate in amps The charge rate has 8 stages It can be adjusted by setting these switches as shown in the following table stone on ow ow
37. r Charger Wire Gauge AWG Output 1000W 31 ft 2000W E AOAI Do not use 3 Battery e Connect Fuse NEC National Electrical Code article 551 requires that you connect all of your Inverter Charger s positive DC Terminals directly to a UL listed fuse s and fuse block s within 18 inches of the battery The fuse s rating must equal or exceed the minimum DC fuse rating displayed on the Inverter Charger s nameplate See diagrams below for proper fuse placement may result in a lethal electrical shock hazard e Never attempt to operate your Inverter Charger by connecting it directly to output from an alternator rather than a battery or battery bank e Observe proper polarity with all DC connections WARNING Failure to properly ground your Inverter Charger to a vehicle s chassis or earth ground 3 4 2 Non Vehicular or Vehicular Your Inverter Charger s Nominal DC Input Voltage must match the voltage of your battery or batteries 12 Volts in most vehicular applications It is possible to connect your Inverter Charger to the main battery within your vehicle s electrical system In most vehicles the Inverter Charger will be connected to one or more dedicated auxiliary house batteries that are isolated from the drive system to prevent possible draining of the main battery TRIPP LITE 12 Volt Inverter Charger 12 Volt Main Battery Connection TRIPP LITE 12 Volt Inverter Charger
38. round Equipment Connection Warnings e Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide e You may experience uneven performance results if you connect a surge suppressor line conditioner or UPS system to the output of the Inverter Charger e User must supply proper protection for wire openings in unit panels Operation Warnings e Your Inverter does not require routine maintenance e Potentially lethal voltages exist within the Inverter Charger as long as the battery supply is connected During any service work the battery supply should therefore be disconnected e Do not connect or disconnect batteries while the Inverter Charger is operating from the battery supply Dangerous arcing may result 1 Overview and Features 1 1 Overview e Tripp Lite s Sine Wave Inverter Charger is a heavy duty unit generating a pure sine wave from a 12V battery bank It can supply energy to a wide range of connected equipment from heaters air conditioners refrigerators and vacuum cleaners to computers and peripheral devices It is designed to work in heavy load conditions so de rating is unnecessary e The smart charger is compatible with various ba
39. ttery types and sizes The switch module automatically diverts the energy transfer path between the inverter and an AC input When the AC source is lower than the transfer level the path switches to the inverter Otherwise the load is powered by the AC input 1 2 Indicators Controls and Settings 1 2 1 Controls and LED Indicators Shown below are the control panel and indicator lights on the front panel of the Inverter Charger DCMODE ACNODE INVERTER BAT ERY INVERTER CHARGER CONDITION LIMITS BATTERY VOLTAGE O JOFF MAX Q fovT HIGH 25 50 79 100 ee oe oe A ee ee Oe oe RESET O ON FLOAT xoL O LOW mms m 000007 Ge o gt o lt FEATURES SETTINGS 1 DC AC TRAN DELAY 2 LOW BATT ALARM 11 2 10 9 3 LOW ACV TRANSFER TA UUUUUUUL 4 SEARCH LOAD MODE CHARGER SETTINGS 5 FLOAT VOLTAGE 6 7 8 AMPERES i TEMPERATURE BATTERY COMMUNICATION E Power ON OFF Button E LED 4 Battery Limits E LED 8 100 Battery Voltage EJ LED 1 DC Mode Inverter Fl LED 5 25 Battery Voltage El Battery Temperature Port RJ11 EJ LED 2 AC Mode Charger Ed LED 6 50 Battery Voltage EA Communication Port RJ45 El LED 3 Inverter Condition EJ LED 7 75 Battery Voltage 1 Overview and Features LED and Alarm Indicator LED LED2 LED3 LED4 LEDS LED6 LED7 LEDS Alarm AC Normal oes 10 8V 11 5V 11 5 12 5V 12 5 13 5V gt 13 5V DC Mode 10 2 11 5V 11 5 12 5V 12 5 13 0V gt 13 0V Battery Low ey
40. vertidor cargador no son bater as de ciclo profundo su ciclo de vida util se puede ver considerablemente reducido Si utiliza el mismo m dulo de bater as para alimentar el convertidor cargador que las cargas CC su m dulo de bater as necesitar tener el tama o adecuado las cargas mayores requerir n un m dulo de bater as con mayor capacidad amperio hora o los ciclos de vida til de las bater as se ver n considerablemente reducidos El montaje ideal ser a de bater as de pila hidroel ctrica ventiladas o de c lulas de gel malla de fibra de vidrio absorbente selladas Coloque el interruptor 5 en OFF para bater as de Celda H meda y en ON para bater as de Malla de Fibra de Vidrio Absorbente AGM Tambi n son aceptables dos bater as de 6 Volts Carro de Golf Marinas de Ciclo Profundo o 8D de Ciclo Profundo en serie En muchos casos la nica que se puede instalar es la bater a de un veh culo Las bater as auxiliares deben ser id nticas a las bater as del veh culo si se conectan entre s 18 3 1 1 Ajuste de la capacidad amperio hora de la bateria a su aplicacion Seleccione una bater a o un sistema de bater as que proporcionen a su convertidor cargador el voltaje CC y una capacidad amperio hora adecuada para alimentar su aplicaci n Aunque los convertidores cargadores de Tripp Lite disponen de una alta eficiencia de conversi n de CC a CA sus capacidades de r gimen de salida est n limitadas por la capacidad amp
41. vida del convertidor 3 3 2 Cerramiento de la bater a Las bater as se deben instalar en un cerramiento o una habitaci n ventilados y cerrados con llave El cerramiento debe estar bien ventilado para evitar la acumulaci n de los gases de hidr geno que se liberan durante el proceso de carga de la bater a El cerramiento debe ser de un material resistente al cido o estar revestido con un acabado resistente al cido para evitar la corrosi n que pueden causar el electrolito derramado y los gases liberados Si las bater as est n coladas en exteriores el cerramiento debe ser impermeable y tener pantallas de malla para evitar que entren insectos y roedores Antes de colocar las bater as en el cerramiento cubra la parte inferior con una capa de bicarbonato que neutralizar cualquier derrame de cidos 3 4 Conexi n de la bater a 3 4 1 Conecte su convertidor cargador a las bater as por medio del siguiente procedimiento e Conexi n del cableado CC aunque su convertidor cargador es un convertidor de electricidad de alta eficiencia su capacidad de r gimen de salida est limitada por la longitud y calibre del cableado que va desde la bater a a la unidad Utilice la longitud m s corta y el di metro m s ancho posible calibre maximo 2 0 para brindar el m ximo desempe o consulte la tabla de abajo Los cables de calibre m s grueso y m s cortos de longitud reducen la ca da de voltaje CC y permiten la m xima transferencia de corrient
42. voltaje de entrada CA disminuye por debajo del punto de ajuste el inversor autom ticamente cambiar al MODO CD Vea la tabla para los detalles Voltaje Nominal PUNEO AE aca hs ars voltaje de carga Regreso al punto de voltaje CC a CA A ee 1 2 9 Configuraci n del modo de b squeda Interruptor 4 El modo de b squeda se activ cuando la unidad est funcionando en modo convertidor alimentaci n de la bater a para evitar que la bater a se descargue sin necesidad cuando no se requiere alimentaci n el ctrica Si el convertidor est soportando cargas que se deben alimentar continuamente apague el interruptor 4 para deshabilitar el modo de b squeda 1 2 10 Voltaje tipo flotante de la bater a Interruptor 5 Interruptor5 Voltaje Variable Voltage de Aceptacion Tipo de Bateria Malla de Fibra de Vidrio Absorbente ON Predeterminado 13 8V 14 5V AGM Absorbed Glass Mat 13 2V 13 8V Celda H meda Wet Cell Nota La unidad cargar la bater a al voltaje de Aceptaci n continuar hasta por 12 horas y luego caer al voltaje de Flotaci n 17 1 Vision de conjunto y caracteristicas 1 2 11 Configuracion del r gimen de carga de la bateria interruptores 6 7 y 8 Estos interruptores controlan el regimen de carga maximo en amperios El regimen de carga tiene 8 fases y se puede ajustar configurando estos interruptores como se muestra en la siguiente tabla Interruptor 6 ON PON OFF JUE A OFF OFF ON oN

Download Pdf Manuals

image

Related Search

Related Contents

Maytag Range CHG9800B User's Manual  Audiovox RC250BK  Manual de Usuario    Model C-RL - GE Measurement & Control    お使いになる前に(PDF:9.95 MB)  HDC2000 – Hydrant Drive Card  watchout-irpw risco manuel fr (3.22 Mo)  Les éditeurs - Association Lecture et Loisirs  

Copyright © All rights reserved.
Failed to retrieve file