1. Threshold User Network Mail SNMP SSL PDU User Manual Ver 1 0 15 Configuration SNMP When event occurs PDU can send out trap message to pre defined IP address Trap Notification Set receiver IP for trap Community Set SNMP community Read Community is public and fixed Default Write Community is public and can be modified by user e a energente w Total load 0 0 A Status Normal Information Trap Notification PDU Poe Fr Receiver IP 192 168 0 1 System Control Apply Outlet Community Configuration Read public PDU Write public Threshold User Apply Network Mail SNMP SSL PDU User Manual Ver 1 0 16 Configuration SSL Enable SSL for web communication User must input the correct ID and password to enable SSL function The ID and password must be the same with the setting in User A gt energente Total load 0 0 A Status Normal Information PDU System Control Outlet Configuration PDU Threshold User Network PDU User Manual Ver 1 0 Enable SSL Confirmation ID Password O 17
2. username and password be sent in an insecure manner basic authentication without a secure connection User name Password F Remember my password o cme PDU User Manual Ver 1 0 Information PDU Display total PDU and each outlet power consumption When plug the option device ENV probe it will display temperature and humidity information Information PDU System Control Outlet Configuration PDU Threshold A energenie Total load 0 0 A Status Normal PDU PDU 0 0 A Normal Threshold Warning 12 0 A Overload 16 0A PDU User Manual Ver 1 0 Information System Indicate PDU system information including Model No Firmware Version MAC Address System Name System Contact Location o 4 energente Total load 0 0 A Status Normal Information Model No EG PDU 001 PDU Firmware Version s4 82 091012 1cb08s System MAC Address 00 16 18 77 1D B9 Control System Name PDU Outlet cin System Contact Admin PDU Location Office Threshold om Network Mail SNMP SSL PDU User Manual Ver 1 0 Control Outlet Indicate PDU outlet on off status and control outlet Select the outlet by checking the box and then click ON or OFF button to control output power for PDU Monitored PDU series does not support this function ON Press the icon to turn on the assigned outlets OFF Press the icon to turn off the assigned outlets OFF ON Pr
3. PDU User Manual Table of Contents 1 AERO OUCTION orinar air Die a natura ea 1 2 PDU Package e 2 3 FUNCION ee A ea en A eee delet eee ae 3 4 Installation A A de 5 5 Web Ntra iia 7 1 Introduction The PDU s an Internet ready device designed and is equipped with an intelligent current meter True RMS that will indicate the total power consumption of a power strip The PDU offers an easy set up and user friendly communication software This software provides the function that assistant manager to remotely monitor the multiple PDU power consumption to realize the total current power consumption and utilization for the enterprises Features Built in web server manager can real time to monitoring the current consumption of the power strip Build in true RMS current meter Setup easily meter can read the IP address directly Homepage support SSL Provide audible alarm when the power consumption over the threshold of warning and overload Send the email and traps when the power consumption exceed the trigger value of warning or overload to the PDU Provide utility it can monitor a large mount of PDU at the same time Support the SNMP and provide MIB for the PDU to be monitored by NMS Provide per outlet power protection by the circuit breaker Real time to control outlets of PDU Indicate outlets status with LED Support power on sequence Option accessory can support temperature and humidity detection
4. PDU User Manual Ver 1 0 2 PDU Package The standard PDU package contains a Power Distribution Unit with supporting hardware and software The components of the package are Power Distribution Unit Rack mount Brackets CD ROM it contains User Manual PDU Software MIB Management Information Base for Network PDUMIB mib Adobe Acrobat Reader PDU User Manual Ver 1 0 Interface Single current bank Functions Description Ethernet RJ 45 port for network communication port Audible Alarm Warning 1 beep in 1 second Overload 3 beeps in 1 second Note The audible alarm will keep beeping until the current gets back to normal and the current is lower than the threshold to 0 5 amps Function Button e Press and release to turn off the warning beeping The overload beeping can not be cancelled e Press and hold the key after 2 beeping it can let the meter to show up the IP address e Press and hold the key after 4 beeping it can change the way to get IP by DHCP or fixed IP e Press and hold the key after 6 beeping it can reset PDU back to default setting Meter 3 digits to display current and IP Address ID The identification of power bank or PDU LED Indicator SSL yellow Light on means web access is protected by SSL DHCP Green Light on means PDU gets IP address by DHCP PDU Green Indicate each output power status Status Red Indicate each circuit status by model PDU User Manual Ver 1 0 ENV RJ11
5. ad 0 0 A Status Normal Information PDU System Control Outlet Configuration PDU Threshold PDU User Manual Ver 1 0 Original ID Password New ID Password i A 13 Configuration Network PDU network information Enable DHCP Change the way to get IP address for PDU A N energenie Total load 0 0 A Status Normal Information 1 Address PDU a Host Name DIGIBOARD System IP Address 192 168 Control Outlet Subnet Mask Configuration Gateway 192 168 PDU Y Enable DHCP Threshold DNS Server IP Primary DNS IP 192 168 0 254 Network Secondary DNS IP 0 0 0 Mail Apply SNMP SSL PDU User Manual Ver 1 0 Configuration Mail When event occurs PDU can send out email message to pre defined account Email Server The Email Server only support to be input domain name not IP address Sender s Email Input the sender email address Email Address Input the recipient email address The message in the email Indicate OutletA H XXXXXXXX status in order X 0 means the power off X 1 means the power on Note Make sure DNS server can resolve the Email Server s domain name in energenie Total load 0 0 A Status Normal Information PDU Email Setting Email Server Imail your com System a Control Sender s Email sender yourcom com Outlet Recipient s Email Address Configuration Email Address PDU
6. ess the icon to reboot the assigned outlets Information PDU System Control Outlet Configuration PDU Threshold PDU User Manual Ver 1 0 PDU OutletA OutletB OutletC OutletD OutletE OutletF OutletG OutletH x energenie Total load 0 0 A Status Normal Status ON ON ON ON ON ON ON ON OFF kh kk kh kh kk hd 10 Configuration PDU Set the outlet name and delay time Name Rename the outlet ON Set delay time for power on sequential OFF Set delay time for power off sequential Note The maximum delay time is 255 seconds gt energente Total load 0 0 A Status Normal Information ON OFF Name Delay Delay sec sec Syst System OutletA 1 1 Control OutletB 2 2 Outlet r Configuration Bat E PDU OutletD 4 4 Threshold OutletE 5 E User OutletF 6 6 Network OutletG 7 7 Mail ds QutletH 8 8 s PDU User Manual Ver 1 0 11 Configuration Threshold Set the warning and overload threshold for each circuit Set lower and upper threshold for temperature and humidity e gt energenie Total load 0 0 A Status Normal Information Threshold Amp Name PDU Warning Overload Control Outlet Configuration PDU Threshold PDU User Manual Ver 1 0 12 Configuration User Change ID and password Default ID is snmp and password is 1234 e gt energente Total lo
7. for ENV probe attached Circuit Breaker Overload power protection PDU User Manual Ver 1 0 4 Installation This section will provide a quick instruction to install the PDU Rack Mount Instructions A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern E Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Diagram PDU Install In the Rac
8. k gt PDU Install In the Rack I PDU Install In the Rack Remote Monitor The multiple PDU power I PDU Install In the Rack gt lt PDU Install In the Rack Local Monitor e PDU Install In the Rack PDU User Manual Ver 1 0 Hardware 1 Install mounting brackets 2 The PDU comes with brackets for mounting in a rack To mount the PDU into a rack performs the following procedure 3 Attach the mounting brackets to the unit using the four retaining screws provided for each of the brackets 4 Choose a location for the brackets 5 Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retaining screws 6 Connect input and output power 7 Connect Ethernet cable to the PDU 8 Switch on the PDU Note 1 The default setting for the way to get IP address is DHCP If PDU can not get the IP from DHCP server the IP address will stay at 192 168 0 216 Note 2 TO SETUP THE NETWORK SYSTEM FOR PDU STRONGLY RECOMMAND TO BUILD UP THE POWER MONITORING NETWORK SYSTEM ISOLATED WITH THE OTHERS IN ORDER TO KEEP THE STABILITY OF GETTING POWER INFORMATION AND SYSTEM OPERATION PDU User Manual Ver 1 0 5 Web Interface Login Input the PDU IP address in web browser Default ID is snmp Password is 1234 Connect to 192 168 0 59 The server 192 168 0 59 at Protected requires a username and password Warning This server is requesting that your