Home
Premier PRF-100 flat panel wall mount
Contents
1. gt D PREMIER C44 MOUNTS CREATING POSITIVE CUSTOMER EXPERIENCES INSTALLATION INSTRUCTIONS PRF 100 VESA Mount for 15 to 32 Flat panels NORTH AMERICA EUROPE 3130 East Miraloma Avenue Unit 3 The Moorings Business Park Anaheim CA 92806 USA Channel Way Off Blackhorse Road Exhall USA and Canada Coventry England CV6 6RH Phone 800 368 9700 Fax 800 832 4888 Phone 44 0 2476 614700 Fax 44 0 2476 614710 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 Premier Mounts 2011 9531 003 011 00 A 24 PRF 100 Warning Statements n 2 Parts TAS E 3 aao TOO E ENA N AE E E E trancneteiereaeae 3 Wo Stud nstallation EEEn 4 Concrete Surface Installation ainn EE 5 Cover Plate Installation iiinn EEE 6 E a B a a E E E EE ENN TET SE O NEA EAA VESA 6 Tea ee eE a E E A ae enee anon uaeanae 7 NY UTE ANN eae cetacean avec eet ncetec teach ce ee act neces ee aeolian tera inant aaica er raceaemmnarnaiee 8 Warning Statements PRIOR TO THE INSTALLATION OF THIS PRODUCT THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND COMPLETELY UNDERSTOOD THE INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS y PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNA
2. A eee Prior to installation remove the cover plate and two 2 M6 x 75mm Phillips head locking screws from the PRF 100 Visual Centering Diamond The visual centering diamond will allow you to determine the center of the wood stud It will also allow you to determine the exact center for the flat panel placement on the wall The visual centering diamond will work in conjunction with the visual stud guide Visual Stud Guide The visual stud guide will allow you to determine exactly where both edges of the wood stud is within the wall Once both edges of the wood stud have been located the visual centering diamond will be directly over the exact center of the wood stud Once the plate is in this position the two mounting holes may be marked Directional Arrow Mak Visual Centering Diamond Visual Stud Guide Stud S r Electronic 71 Stud finder Center Line SS Step 1 Place the wall plate against the wall with Step 3 Use an electronic stud finder to locate the the directional arrow pointing up stud Step 2 Use a pencil to make a mark in the center Step 4 Align the plate to the stud and visually of the visual centering diamond This will verify the flat panel placement now that be the center position of the flat panel the stud has been located Step 5 Once the center of the stud has been located mark the wall at the two 2 screw hole locations Visual Stud Guide 10 x 2 Screws 1 8 B
3. UTHORIZED ATTACHMENTS OR MODIFICATIONS AND IS NOT RESPONSIBLE FOR ANY DAMAGES CLAIMS DEMANDS SUITS ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE ATTACHMENTS OR MODIFICATIONS THE SURFACE MUST BE CAPABLE OF SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF THE Flat panel IF NOT THE y MOUNTING STRUCTURE MUST BE REINFORCED THE MAXIMUM WEIGHT THAT CAN BE USED WITH THIS PRODUCT IS 50LBS PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN AS OUTLINED IN THE INSTALLATION INSTRUCTIONS MUST BE ADHERED TO FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY OR EVEN DEATH SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT USE PROPER SAFETY y GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY At least two qualified people should perform the assembly procedure Injury and or damage can result from dropping or mishandling the flat panel 1 If mounting to studs make sure that the mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is recommended Be aware of the mounting environment If drilling and or cutting into the mounting surface always make sure that there are no electrical wires in wall Cutting drilling into an electrical line may cause serious injury Make sure there are no water lines inside the wall where the mount is to be located Cutting
4. crews DO NOT OVERTIGHTEN THE MOUNTING SCREWS Step 2 Secure the cover plate to the flat panel using four 4 M4 x 10mm combo head SCrews The slotted opening of the cover plate must be facing up and the flat surface touching the flat panel surface pee If the threading on the flat panel is too A deep use four 4 M4 x 12mm combo head screws instead Mounting Slot Tab The cover plate mounting slot must be facing up A Step 1 Lower the flat panel onto the wall plate so that the mounting tab is inserted into the mounting slot Do not release the display until you are sure the flat panel is resting securely on the wall plate Page 6 Mounting Head Locking Screws Screwdriver Step 2 Secure the two plates by inserting and tightening the two head locking screws located at the bottom of the cover plate Use a Phillips head screwdriver to tighten these screws Installation Instructions PRE 100 tH Technical Specifications All measurements are in inches mm O70 2 70 100 75 ain N 4 Please refer to the hardware pack that is included with the PRF 100 to determine the correct mounting hardware for your application NOTE A 100 X 100 VESA Pattern B 75 X 75 VESA Pattern Installation Instructions Page 7 gt 4 Se PRE 100 Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts war
5. drilling into a water line may cause severe water damage to the mounting surface f This product is intended for indoor use only Use of this product outdoors could lead to product failure and personal injury A Do not install near sources of high heat Do not install on a structure that is prone to vibration movement or chance of impact Contact Premier Mounts with any questions 800 368 9700 techsupport mounts com Page 2 Installation Instructions gt 4 PRE 100 24 Parts List Congratulations on the purchase of your new Premier Mounts PRF 100 flat panel mount This AN NOTE i i mount is shipped with all proper installation hardware and components Make sure that none of these parts are missing and or damaged before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts at 800 368 9700 Wis PRF 100 Qty 1 Ko K M4 x 10mm Combo M4 x 12mm Combo M6 x 12mm Combo 10 x 2 Screws 10 x 1 1 4 Screws 10 Wall Head Screw Qty 4 Head Screw Qty 4 Head Screw Qty 2 Qty 2 Qty 4 Anchors Qty 4 If your unit requires alternative mounting hardware use commercially available hardware or contact Premier Mounts at Installation Tools not supplied ee 9 le Phillips Screwdriver 1 8 Drill Bit 1 4 Drill Bit Electronic Stud finder Drill Level Installation Instructions Page 3 gt Z PRF 100 Wood Stud Installation
6. it Pilot Hole Drill j gt gt Step 7 Insert two 2 10 X 2 screws into the pre drilled pilot holes Tighten the wall plate screws at this time Step 6 Use a 1 8 bit and create pilot holes where the 2 markings were made Step 8 Page 4 Installation Instructions PRF 100 b 4 ee Concrete Surface Installation Step 1 Step 2 Step 3 1 4 Bit Pilot Hole Installation Instructions You will have four 4 mounting A NOTE holes when installing into concrete Use the visual centering diamond to help determine the placement of the back plate Once the mounting placement has been determined use a pencil to mark the mounting points Drill the mounting holes using a 1 4 drill bit where the pencil marks have been made Place the 10 anchor into the hole and tap into place Place the backplate over the inserted 10 anchors Insert four 4 10 x 1 1 4 screws into the 10 anchors and tighten using a Phillips tip screwdriver Pilot Hole 10 Anchor 10 x 1 1 4 Screw Screwdriver Page 5 Cover Plate Installation P A M4 x 10mm combo head screw 5 Slotted Opening Ss UON gt a Cover Plate 5 Flat panel Installation PRF 100 Step 1 Re attach the M6 x 75mm Phillips head locking screws to the cover plate If the flat panel is not long enough to cover the length of the M6x75mmscrews replace them with two 2 M6 x 12mm combo head s
7. ow within thirty 30 days Proof of purchase an original sales receipt from the original con sumer purchaser must accompany all warranty claims Warranty claims must also include a description of the problem the purchaser s name address and telephone number General inquiries can be addressed to Premier Mounts Customer Service at 1 800 368 9700 Warranty claims will not be accepted over the phone or by fax Premier Mounts Attn Warranty Claim 3130 East Miraloma Ave Anaheim CA 92806 How State Law Applies THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Page 8 Installation Instructions
8. rants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product The limited warranty is valid only for the original purchaser of the product What Premier Mounts Will Do At the sole option of Premier Mounts Premier Mounts will repair or replace any product or product part that is defective If Premier Mounts chooses to replace a defective product or part a replacement product or part will be shipped to you at no charge but you must pay any labor costs What is Not Covered Limitations PREMIER MOUNTS DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS ADAPTERS DIS PLAYS PROJECTORS OTHER PROPERTY OR PERSONAL INJURY RESULTING IN WHOLE OR IN PART FROM IMPROPER INSTALLATION MODIFICATION USE OR MISUSE OF ITS PRODUCTS PREMIER MOUNTS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUD ING BUT NOT LIMITED TO INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOV ING AND REPLACING DEFECTIVE PRODUCTS OR PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address bel
Download Pdf Manuals
Related Search
Related Contents
Simulation EIS Energy Sistem Energy Soundbar 300 Network Camera FXC-1302/W MGP32X/MGP24X Owner`s Manual HP NX6110 User's Manual IQ plus® 355 - Rice Lake Weighing Systems Verbatim HD Video SDHC 16GB 6 Hours Brukerveiledning 2 User manual 9 Käyttöohje 15 NO GB FI Rotel RMB-1506 audio amplifier PDF - Municipalnets Copyright © All rights reserved.
Failed to retrieve file